July 5, 1974
RECEIVED
JUL 11 1974
M. E. EISENHOUR
VCl Chromatograph (CMVII VFA - Model 1200) Computer Data
The Dispersion Vinyl Resins Unit staff has found the twenty-point chromatograph to be a key instrument in its campaign of VCl exposure control.
The chromatograph analyses can be organized and manipulated to give the VCl concentration for different parameters on a daily basis, a month-todate basis and a year-to-date basis.
The chromatograph takes 720 samples daily. The long manual and manpower-consuming calculations required to compute the chromatograph results limit our ability of using this instrument efficiently. In order to take full advantage of the chromatograph and in order to obtain the various data needed by the 08500 Department, a computer system is absolutely necessary.
On the next page is a list of the data needed by the 08500 Department.
For further information or clarification, please contact me at Extension 2821.
Sincerely,
CB/ra
Claude Bayard Safety Coordinator
UCC 094428
/z * '+ i DISPERSION VINYL RESINS CHROMATOGRAPH COMPUTER DATA BANK REQUIRED
* 1. Daily average of each of the 19 points points (Point #20 is a test point).
* 2. Month-to-date average of each of the 19 points.
3. Year-to-date average of each of the 19 points.
* 4. Daily number of peaks above 50 ppm for each of the 19 points.
-Hr
* 5. Month-to-date daily average of peaks above 50 ppm for each of the 19 points
6. Year-to-date daily average of peaks above 50 ppm for each of the 19 points.
* 7. All the above (l->6) for all 19 points combined.
8. All the above (1--^7) per shift (A, B, C, D).
9. All the above (1-->8) per job, except Item 7.
10. Graphs on all above data (1--W); (bar graph),
11. Number of samples involved in computing the above averages (1--9).
12. Standard deviation analysis of the above (1--S).
13. Alarm system to identify points above 50 ppm (Tape System).
14. Computer to be able to hold memory in case of power loss.
*Data presently calculated manually.
__ J_
C. Bayard/ra July 5, 1974
UCC 094429