Document aBwDpnyjLYXBOOayOQpn224ZR
Title 20--Labor
emergency rcturv.ciry standard <t*t forth
CHAPTER XVM--OCCUPATIONAL SAFETY
AWO HEALTH Ar: ::.';CTnATlON, DE PARTMENT OF U.zzn
PART 1910--OCCUPATIONAL SAFETY ANO HEALTH STANOAROS
Emergency Temporary Standard on Certain Carcinogens
below Li
tu protect the employ-
t'rrmi such c->:*!-.11ro
PurutiNic to
nrviv'.iin.* -*ii
nt `*.r
?.
.'-fr- :n ac
cordance with suciton (J'b< of cite act.
la which the emergency temporary standard will serve as a proposed rule,
together with other subsidiary rules. As
Pursuant to section 6(c) of the WU-
Uams-Stcttfcr Occupational Safety and
Health Act of 1070 *29 UJ3.C. G> and
Secretary of Labor's Order No. 12-71 (3S
FR 8734). part 1910 of UUc 29. Code ot
Federal Regulations, is hereby amended
la the manner set forth below, in order
to provide an emergency t'um'onvry
standard deniiiv? `U the cpvur& of
employee* t-
lifted xu-^tances
th\t r.- 'T." ...........-
soon os possible, a draft environmental impact statement will be (lied with the Council on Environmental Quality, and copies will be sent to other appropriate Federal agencies for their comments. In addition, a copy of the proposed rules to be noticed under section G<b> will bo sent to the Environmental Protection Axonry for its comments under section 309 of the Clean *lr -Vt.
Purt 1010 is iinondcd by adding a new
Concern :or Uic ur.uucrs jr.nctene In 2 1910.j-!c to rend as follows:
the ocrujaUwnal exposure to ourclco- S I9l0.93e Carviautfeiw.
genie substances was one of the reoaone for enaetment of the oca See Senate Re* port No. 91-1282. 91st Congress. 2d seestoo. 2 (1970) .
Administrative attention was ad dressed. tb the problem about 1 year ago. On May 22. 1972. the Deputy Assistant Secretary of Labor for Occupational Safety and Health- requested informa tion from the Director of the National Institute for Occupational Safety and Health (NTOSHV on nla* subetanees ab
(a) Scope and application.--`This secUou applies to any activity in which a carcinogen Is manufactured, processed, used, repackaged, released, handled, or otherwise present in any manner.
(b> Di/tnittons. -- 11) "Carcinogen" means any of the substances Usted be low, or compositions containing such substances, but doss noe include com positions containing less than l percent by weight of the listed carcinogens:
leged to be carcinogens. As part of hie effort to gala the best available scien tific date, the Director published on July 6L 1972. at 37 FR 13289. a request for
Cem>
pNu*ts
CtieaSMb
CbatBlni
caniMoKTtvraaycu
Information concerning is substances.
Tlie data, arguments, and conclusions re ceived by NTOSH were made available
t--
]__
R. .M. M:W-.WMAM-(ivamUoiriifuiiiwittuBIiMhiwyMl.r..<......M.................
`,r^*r?sl
to the Occupational Safety and Health Administration.
The Office of Standards continued
<
1W.-_.^:--_______.aHLr-I|uUX*niwMm.bNl>d.a.HVirii*MUi rlivluWUliiU<lann*iliii<namH..U.i.n._ili.t^.s....
LMJKIKI77
lt work on carcinogens in preparation for iznUdug recommendations for a standard under section 8 of the set.
On January 4. 1973. as petition for an. emergency temporary standard, sub mitted by the OIL Chemical, and Atomic
v1MUI1--_.1---.:_--m._,._---.T.1... bH.W1v.M4^>*dv<-aitM]tcdiHnf'wimUwtmltiwi|frHet--Unhi-Aw>tthnv-itI--tMpmtP-ptb->CL.-mi.-ir.-m-lm:.--'.crt-.w.ll.-M.w...-...-...rr.-..Q..-.....-.a..1-..j.i-i..073LMIwU4TJISHe74*4Sl
n......... --M..4.M.
MUM
Workers Union and Health Research
Group, was received: and acknowledged by the Departmentof Labor. The petition contained relevant information on the danger of exposure to 10 of the carcin ogens listed in the standard.
On February 9. 1973. the Assistant Secretary of Labor published in the F*nuu, Rtozsrsa (38 FR 4Q37>. a notice of the receipt, of the petition for of an emergency temporary standard,
(2) "Controlled area" means an area to which access Is restricted and: cantrolled by the employer..
(3) "Decontamination" means the re moval or chemical neutralisation of & carcinogen to a form that is either nontoxic or not capable of easy absorption Into the body.
(4) "Present" includes manufactured,
and a request, for Information from In processed, used, repackaged, released,
terested persons mi the issues involved. handled, or otherwise present.
In response to the notice, more than
SO written comments'were received, pro
viding valuable additional information,
data, and material.* mnmrnJny carcin
controlled
dirty
ogens.
area
changa*
On the basis of all the relevant Infor mation before us. it Is hereby found that: (l) The 14 carcinogens listed In
room
the emergency temporary standard are
toxie and physically harmful: (2) that exposure to any of the 14 substances poses a grave danger to employees: (3) that employees are presently being ex posed to the substances; and (4) that the
(2) A controlled area may also be connected with an uncontrolled area by means of emergency exits which may only be used In cosq of emergency, such as Are.
fc'li Controlled areas.--(l> Any area
in 'vhich any <:^.rcm'^?n is present shall
be cec!T\cti a
sv
c-ii i.i
i- ri*rti,v*xl a
mr.'rnli'' 1
if pr-1* *-- of a cor*
cinogeti rcMiiLS otuy from a transship
ment in reeled packages.
i'2> Open-process vessels and open
containers.--Open-process vessels and
open containers of a carcinogen shah be
permitted only at container Ailing points
and at points whero contents of contain
ers are charged into process vessels, and
only to the excrete necessary to permit
transfer of contents. Such transfers
shall be under continuous Local exhaust
ventilation which shall prevent the dis
persion of the carcinogen into any work
area. The transfer facilities shall have
provision to confine any 3piUs to the area
served by the vcntllatioa system.
(3) Toilet facilitin and drinking /oun-
fains.--No eoilet facilities and no
drinking fountains shall be used inside
a controlled area.
(4) Food and beverage.--No food or
beverage shall be permitted within a con
trolled area.
(5) 5/ao.tfng.--No smoking or smoking
materials shall be allowed within a con
trolled area.
id) (1) Access to controlled areas.--
Except as provided la subparagraph (2>
of this paragraph, any controlled area,
may be connected with an uncontrolled
area only by means of change rooms and
shower rooms so arranged chat an. em
ployee. In order to enter or leave die
controlled- am. must go through the
following procedures:
(l> la order to enter, an employee must
undress completely in a clean change
room outstde the cootroiled area, and
put on clean protective clothing and
equipment: he may eater the controlled
area through an entrance designed to
prevent the escape of carcinogens from
the controlled area- to the change room:
til) In order to leave a. controlled area,
on employee must eater a separate dirty
change room where- he must undress
completely and leave every item of cloth
ing end equipment, then he must shower
in an adjacent room which he-may enter
through an entrance designed to prevent
the escape of carcinogens from the dirty
change room to the shower room. There
after. he must enter the clean change
room where his street clothes are in his
locker.
(lii) a physical layout which would
conform, to this subparagraph is illus
trated below:
elann
change
room
*
(3> Appropriate Instructions and signs shall be posted to inform employees of the procedures that must be followed in entering and leaving a controlled area,
i4> The clean change room shall have
noUAL ISOICTfR. VflL 3S, NO. SS--THURSDAY, MAT 3. 1973
_
2076(5055
BFG05583
RULES AMO REGULATIONS
mzi"
Definitions of the terms "number or
employees" acid
rr-.cc; -cs" h"-vo
been Added in order to facilitate (he ao-
plication of the paragraphs where the
terms are used.
2. Paragraph (a)(4) or the proposal
purported to regulate expectorating in.
workplaces. On the basis or several corn-
menu received In opposition to this pro
posed subparagraph, any reference to
expectorating has been removed from the
final standard. The general requirement
under paragraph (a) i3> U). Housekeep
ing. requiring clean places of employ
ment. Is sufficient to cover any problems
arising from expectoration.
3. The proposed waste disposal stand
ard would have required tight-fitting
covers on waste receptacles. Several com
ments pointed out that the provision
would restrict unnecessarily the design
of waste receptacles, and that there are
many operations where sanitary condi
tions can be maintained. but where tight-
fitting cover* would moke operations im-
pracuble. The adopted standard takes
these comments into consideration, and
does nob require a tight-fitting cover if
sanitary
can. be maintained
without-bna; The proposal-otto required,
such receptacles to be leakproof. The
adopted standard recognises that other
receptacles can be used where a process
so requires, sa tong as sanitary condi
tions can be maintained.
4. ft'omsed paragraph (aMfi). Ver
min Control. would have required work
places and personal service rooms to be
constructed, equipped, and maintained so
aa to prevent entrance or harborage of
rodents. Insects, and other vermin. The
proposal would also require, institution
and documentation of an extermination
program where vermin were detected.
Many comments asserted that it is im
possible to. make a workpiece completely
vermlnpraof. The comments favored the
text of the wetter i isiouilfau*)
which, requires venainproofing **so far
as reasonably practicable." This text
seems to be more realistic than the pro
posal and Is accordingly incorporated la Awni standard.
Comments ware, also received object
ing to the recordkeeping requirements of
paragraph (ai <> aa being, too burden
some to employers*, and unnecessary for the maintenance of adMtiaii vmmii-m-
control program. It Is decided that docu
mentation of vermin control programs la
not necessary to assure that a particular
program Is effective, and reference to
such documentation is therefore deleted
irom the adopted suuuhuu.
5. Several comments were received on
the proposals time drinking water be
made available wtthln 300 feet of any
place where employees regularly work,
and that toilet facilities be within 300
feet from where employees regularly
work. Some comments stated that the
distance an employee had to walk to a
toilet or drinking facility was not related
to occupational safety and health, and
that the location of such facilities was
merely a matter af convenience. Other
comments sucrresced that the cost of com
pliance with this proposal would result in
severe economic hanUhu). in many cases r.-ttli lilt's er no :*.& w r*m>ioye*.-s. Other comments sucrscctcd Ucures otucr chan 300 feet, ranging aa high as 500 feet. Others suggested that the existing standard, which used the 200 fees as a guide rather than a requirement, should be retained. Other criticisms of the pro posal were also offered, but the basic criticism running through ail the rele vant comments on the 300-foot require ment was to the effect that this distance was arbitrary. As a result of the com ments. no fixed distance Is prescribed concerning the proximity of toilet and drinking facilities located in the estab lishment to the locus of the workplace.
9. The uses of potable and nonpotable water were a source of many comments. Use questions of whether nonpotable water could be used for washing any part of the person, as stated in the proposed revision, was the subject of much argu ment. There; the issue ts whether some treated water which is. not fit for drink ing may be suitable, for washing* Medical testimony was presented to the effect that water used In showering is inevi tably ingested into the body; and that showering la. nonpotable water had led to a great many dermatological and other mwdti-aj problems. Other testimony was to the effect that property treated' non potable water was safe for baching and washing, so long' os precautions were ineffect to insure that the bather did not drink the water, dome testimony was presented concerning different grades of water, aatf that some States had strict standards concerning the chemical and bacteriological regulating of water which was deemed suitable for washing, but not for drinking. There was also evidence in dicating that a substantial number of employees are supplied with water sub ject only to minimal treatment, even when the water comes from heavily polluted- sources.
It Is not clear whether nonpotable water is safe for washing the body. The problem is made even more difficult be cause of the highly varied quality of nonpotable water systems. This uncertaincy-suggests that the basic protection-,
afforded by the existing standard, re quiring the use of potable water for washing, must be retained*-
% Comment* were received with re spect to the poetine provisions proposed In paragraphs (b><2> (l) and (lv>. Sev eral comments pointed out an apparent conflict between the two provisions in that the former required the posting to Indicate for what purposes r.sr.pctable water could not be used, while the latter required the posting to clearly indicate the specific uses of the nonpotable water. Other comments indicated that the posting requirements were exces sively burdensome and expensive. Still other comments argued that other methods besides posting, such os color coding. should be allowed as a means of advising employees that the water Is not suitable for certain purposes.
It Is Important that there be some means of warning employees iliac certain water outlets, have restricted use. The
adopted standard thus retains the re
quirement for
Ui.; ;h..o allows -
automotive means u uv.ruwr .he out- : lets. The conflict which was pointed out os existing in the proposed standard!(
has been resolved by requiring the post-'
jing to indicate clearly the purposes for f |
which such water-is not lo be used. 3. The proposed paragraph <b) (2) (11) 1
would forbid the existence of any crossconnection, open or potential, between
any system carrying potable water and any system carrytng nonpotable water. Proposed paragraph (b> (3) (ill) ap
peared to allow cross-connections, pro viding that backflow of nonpotable water into a potable water system was pre vented. Several comments were* ad
dressed to this possible conflict, some of which advocated the deletion of the par agraph forbidding cross-connections. At the hearing, substantial testimony was
presented on the subject of cross-con nections. to the effect that where effec tive backflow preventive devices ore in
use. the danger paragraph (b> (2) (U) addressed itself to would become obvi ated. Evidence was also Introduced Indi
cating a need for cross-coonecetons- in certain instances throughout Industry. These comments have merit, and accord ingly it is decided that the proposed pro-1
hlbitlon of oil cross-connections should nob be a part of the adopted standard. . The final rule simply states that potable
and nonpotable systems must be con
structed so that backflow and backsiphonage will be prevented.
9. Proposed 11910.141(e). Toilet facili ties. dealt with the construction, loca tion. and number of toilet faculties ' within, a workplace. Many comments were addressed to proposed table J-L which related the number of employe^ at a workplace with TMi**TM*" number^, of toilet facilities. Several comments
suggested that no specific numbers should be Used with reference ro number of toilet facilities required, and that the standard should require only "adequate" or "sufficient" toilet facilities. Others
suggested different number} than those in the proposed table, and. submitted Into evidence and testified on the efficacy of
several State and organisational plumb ing code*. Upon consideration of all these
comments and submissions, table J-i Is made less restrictive- with respect to water closets.
Similar commentary was received con cerning the requirement in the proposal that there be at least one lavatory in the toilet room or immediately adjacent thereto for averv required toilet facilitv.
Tire evidence has been convincing that
this requirement exceeds realistic
bounds, and it is decided chat one lava- '
cory aeed be provided for every three `
required toilet facilities.
1'
10. The proposal would eliminate any reference to separate facilities based on sex. Many comnieucs were received on this Issue. The gist is that the standard..
should require separate toilet facilities for each sex. with specified exceptions.
The comments pointed out that where
men and women .u:.*rcd toilet rooms wv.ii multiple faciliu.es. there coma je serious
207feOGSfi
peoeiAi KSCISTER. VOL 34. NO. SJ--rWUfJOAr, MAT r. 1973
BFG05584
RULES AND REGULATIONS
io&'
:tcL -crvtced so that .aiac;u7 conditions
>i'j nw.iutauwd. shod bu capable of bc-15
' dosed. iml 4!*.All he
-.vtih a
<lv> lea in contact with drtniang
water shall be made of potable water and
maintained in a sanitary condltioo.
(v> Open containers sued as barrels,
pails, or tanks for drinking water from
which the water must be dipped or
poured, whether or not they are fitted
with a cover, are prohibited.
(vt) A common drinking cup and
other- common utensils are prohibited.
(Til) Where single service cups (to be
used but once) are supplied. both a
sanitary container f.r "juiced cuna
and a rcceptario lor dL>'_uur of Uic used
c:.-:a diAli 'zi ... J"
i2) .Voisora:;u
1> OutlcLi for
r.onpotabis ,T.aa.*.r. sucjft as r-ra:ar for in
dustrial or firefighting purposes. shaU be
posted or otherwise marked in a man
ner that will Indicate clearly that the
water is unsafe end is not to be used for
drinking, washing of the person. cooking,
washtng of food, washing of cooking-or
eating utensils, weeding of food prepara
tion or processing premises, or personal
service rooms, or for weeding clothes.
Ul> Construction of nonpotable water
systems or systems carrying any other
nonpotable substance shall be such as
to prevent backflow or backsiphoaage
into a potable water system.
(Ill) Nonpotable water shell not be
used for washing any portion of the
Mwmi wiring ne eating
or
clothing. Nonpotable water may be used for cleaning work premises, other than food processing and preparation prem ises and personal service rooms: Pro vided. That this nonpotable water does not contain concentrations of chemicals, fecal collfonn. or other substances which could create insanitary conditions or be harmful to employees.
(of Toilet facilities.--(1) General.-- U> Except os otherwise indicated in this subdivision (1), toilet facilities, m toilet room*separate for eaehsex shall be-pro vided in all places of employment la accordance with table J-l of this section.
Tfco number of facilities to be provided for each sex shad be based oa the num
ber of employees of that sex for whom
the facilities are furnished. Where toilet
rooms wfll be occupied by-no uxors than
one person at a time, can be locked from
the Inside, and contain at least one wato
closet, separate toast rooms tor each sex need not be provided. Where such single-
occupancy rooms have more than one
toilet facility, only ane such facility is
each toilet room shall be counted for ths
purpose of t ' J-L
Mataa J-l
JffaSnin* number of Humber of employees: teaser eiauu *
n* aa St to UQ
s.
If!rv.m:cm nttniliro/
Humher of vnolereen: -ct7*r dnztUK
111 zo isn
.
fd) Waiting tec '\ > G'-t-
erol.--'.V;. h:r.j
___`.c math-
Over tan.--,,,,., i icioittoaal litore for
mcS ACOttieael 40
employ--*.
1 `Where tol* feeuittee win ao* be uud by wccxdO. unuu may oe pntr.CeC losteod of water eloccia. except :bivt vhe auniMr of water eloeete :a sues caeo* j&ail aoe be re duces to lose uiea V. of me miatoxunx jpeclfieo.
(2) fiaraiortes.--u Lavncor.es shall be made available ia ail places of em ployment m accordance with che require ments for lavatories as set forth in table J-2 of this section. In a muiUple-use lavatory, 24 lineal Inches of wash <nk or 20 inches of a circular basin, *uaa pro vided with water au'iet.i for each space,
(ID--The requirements of subdivision (1) of this subparagraph do not Apply to mobile crews or to normally unattended work locations so long as employees wnrfcm.~ at there u-:u:nns have transportatioa istmedir.t-'y available, toc.'.vt'uj- uulcc lowuhiai winv-h meet Che other requiremuuts of this subparo-
shall be considered equivalent to one lavatory. The requirements of this sub division do cot apply to mobile crews or to normally unattended work locations if employees working at these locations have transportation readily available to nearby waslung faculties which meet the other requirements of this paragraph.
grapii. (ill) The sewage disposal method shall
Tams M
not endanger the health of employees. Tyw<aplemai SaMr.( MUwm nrnnhw
(iv> When persons other than em
imninr^
ployees are permitted the use of toilet
facilities oa the premise, the number of such facilities shall be appropriately in creased in accordance with table J-L of this section in determining the minimum number of toilet facilities required.
(v) Toilet paper with holder shall be
H*auv|aei*i-oiHa i-is
--L
suibtmo, (MMi* f^*
Battuta *04
X
- -X
JHaitar wueiJtfc*
a
uno.
X
OwlS,. I wlSlUant asm*
(acMlitddOaaB*i.i*n- -
provided for every water closet. (rD Covered receptacles shall be kept
In all toilet rooms used by women. (vtl) For each three required toilet as lease one lavatory shall be
fnrtiirtrtnl ftrlncl**
nntiM**, MS
tuikUna. *aa
Mntof show.
t-id*---------^ i SjSSZfiar Met
UX tmoiiiy--
Qw im.^. l itnn a* wok
ii loaiiim
located either in the toilet room or adlucent thereto. Where only one or two toilet faculties are provided at least one lavatory so located shag be provided.
(2) Consfraction of toilet room*.--<U Each water closet shall occupy a separata compartment with a door and wails or partitions between fixtures sufficiently high to-assure privacy.
(ID Xn all toilet rooms installed on or after August 3X. 1971. the floorand side walls; including the angle formed by the floor and sidewalls, and excluding door ways and eaccshees. shall be watertight. The sidewalls shall be watertight to a
of %t least 9 tnnhea
CUD The floors, wells, cefUngs, parti tions. and doom of all todot rooms shaU be of a finish that can be easily cleaned In made, on or after Au gust 31.19TL cove hrww shall be provided to facilitate
(3) Construction end Installation of
(ID Each lavatory snail be provided
with hot and cold running water, or
tepid running wader.
UU) Band soap or
cleansing
agents shall be provided.
(lvi Individual hand towelsor sections
thereof, of cloth or paper, warm air
blowers or clean individual sections of
continuous cloth toweling, convenient to
the lavatories, shall be provided.
(v> Receptacles shall be provided for
disposal of used towels.
(vt) Warm sir blowers shall provide
air at not less than 90* ?. and shall have
means to automatically prevent the dis
charge of air exceeding 140* 9.
(vtl) Electrical components of warm
air blowers shall meet the requirements
of subpartS of this pare.
(3> Sfiotcen^ili Whenever showers
are required by a particular standard,
the showers shail.be provided in accord
ance with subdivisions (ID through (v)
toilet /actfitfcs. (O Every water carnage of this subparagraph.
toilet faculty shall be set entirely free (ID One shower shaU be provided for and open from afl enclosing structures each io employees of each sex or nu
and shall be so Installed that the space merical fracoon thereof, who are re
around the facility can be easily cleaned. quired to shower during the some shift.
This provision does no* proulLiit the u*w (UD Body sop or other appropriate
of wall-hung-type water closets or url- deansuig agents convenient to rfte show
n.i ers shall be provided as specified in para
OD Every water closet shall have a hinged seat made oC substantial mate rial having a aonabsorbent finish. Seats installed or replaced after June 4. 1973. shall be at the open-front type.
am Nomrater carriage collet facilities
graph (d> (2) (UD of this section. Uv> Showers shall be provided with
hot and cold water feeding a common discharge line.
() Employees who use showers shall be provided with individual clean towels.
and disposal systems shall be In accord (e> Change rooms.--Whenever em
ance with J 1910.143.
ployees are required by a particular
ho. K-?t r-
KOClAl XSOtSTER. VOL. 2S. NO. S3--TMUftSOAT. MAY 3, 19V3
'20760057
BFG05585