Document aBvQRbmMz686DarKGNgMva9bX
H. Wulff Geismar - October G, 1976
Page 5
D. Asbestos - Six month sample at cell renewal, G-l, and G-3 cell rooms. (TLV = 5 fibers/ml >5u)
The following table illustrates the concentrations found at each location.
Area & Personal
#1 Slurry tank (personal) #1 Slurry tank (area) Mixing Slurry #1 Slurry tank (15 min. sample) Cell washing area (personal) Asbestos storage area (area) G-l Cell room slurry mixing (personal) G-3 Cell room slurry mixing (personal)
IV. Utilities
Concentration
0.13 fibers/ml 0.014 fibers/ml 0.72 fibers/ml
0.52 fibers/ml 0.018 fibers/ml 0.24 fibers/ml 0.73 fibers/ml
September 16, 1976, an octave band analysis was made'on the pap air compressors in utilities. A separate report, will . . follow giving.the results of this test.
BROOK WAREHOUSE. NEW JERSEY
September 9, 1976, Wayne Skocypec collected five samples at-the ;.. . warehouse for vinyl chloride. The samples, were sent here, and',
analyzed. The .results were.as follows: . (TLV - 1.0 ppm)..
.11 ** .'015 ppm " #2 *' .007 ppm
,, #3 = .015 ppm
.#4.= .007 ppm #11 = .015 ppm
'
All samples were less than the TLV.
PAR TANK GULF COAST INC. WAREHOUSE/DISTRIBUTING OPERAION, GALENA-
PffRK, TEXftsT
.--------- -- :--
September 20, 1976, an industrial hygiene visit was made.to'.
Par Tank in order to determine the vinyl .chloride in the,work.:-^;.v': atmosphere. Samples were taken and the results- were' asfollows; 0.03 and 0.21 ppm. (TLV =1.0 ppm). Both samples were less than the.TLV.