Document aB8eBeby9ea6XYd0qOw8Z3q1Y

Instruments Leeds & Northrup Company General office and Works: 4941 Stenton Avenue, Philadelphia, Pa. Branch Offices: Boston Buffalo Chicago Cincinnati Cleveland Detroit Hartford Houston Los Angeles New York Pittsburgh St. Louis San Francisco Tulsa RUGGED, NULL-TYPE INSTRUMENTS THAT ARE RELIABLE Model S Micromax Recorder Recorda Jrom t to 16 point* on a angle itripchart. Extremely open record. Can operate tignal*. (About I/15th size) Model R Micromax Recorder Record* l or t voint* on a round-chart. Ha* extremely readable dial. Can operate tignal*. (About l/15th tie*) Switchboard Indicator ' Hand-operated. Can & connected through ftfrlor twitches to any number of point*. (About l/10th tize) Electrical Thermometers for Air Conditioning Electrical Instruments for the Heating Plant No method for measuring temperatures fits the specific needs of air conditioning as does the three-lead null-type resistance thermometer method. It is independent of distance and disregards all tempera tures except those right at detector loca tions. The detectors (resistance thermo meter bulbs called Thermohms), can be placed anywhere--in rooms, air ducts or water lines. They are connected by simple electrical wiring to instruments at a central location. Instruments may be: Micromax Recorders, Model S for up to sixteen Thermohms; Micromax'Model R, for related pairs such as wet and dry bulb; indicators with switches for any number of Thermohms; or indicating and recording combinations. This equipment is fundamentally re liable. Instruments and Thermohms are highly responsive, yet rugged in construc tion. A complete system is easy and economical to install, regardless of dis tances. It is easy to operate and demands minimum maintenance. Thermohms and instruments are interchangeable, and can be replaced without disturbing wiring or returning anything to the factory. L&N Resistance Thermometers make it possible to operate efficiently; to main tain comfort or correct process atmosphere constantly ... so that maximum return is realized on the conditioning investment. The facts needed to operate a modem heating plant so as to save fuel, to protect equipment, and to operate efficiently at varying loads are provided reliably by rugged L&N instruments. Readings can be indicated or recorded or both. Re corders can be equipped to operate signals or alarms that warn the operator of extreme conditions. In some cases the instruments control automatically. Micromax Model S provides a per manent record of conditions at from 1 to 16 points on one wide-scale chart. Micro max Model R concentrates on conditions at one point, provides a permanent record, ancKhas a giant indicating dial that can be read at a glance. The switchboard in dicator provides intermittent checks on conditions at one or several points. In the heating plant, L&N measuring, signalling or controlling equipment is used for: * Metermax Combustion Control. Furnace Pressure Control. Smoke Density Analysis. Flue Gas Analysis (Percent COi). Flue Gas Temperatures. Steam and Water Temperatures. Boiler-Furnace Temperatures. Electrolytic Conductivity of Water. J-N-225C2) 1004 Instruments The Liquidometer Corporation 38-16 Skillman Ave. Long Island City, N. Y. Tank Gauges, Liquid Level Controls Remote Reading.Thermometers ADVANTAGES Ob L1QUIDOMEIEK AIND LEVELOMETER TANK GAUGES (1) Accurate check on liquid deliveries and consumption provided. Correct inventory constantly available. (2) Inaccurate and dangerous "gauge sticking" or "taping" methods elimi nated. (3) Tanks can be gauged without loss of pressure or vacuum. (4) Overflowing of tanks--and consequent losses eliminated. (5) Extra handling of liquids in many instances saved. (6) Costly shut-downs due to lack of fuel prevented. (7) Approved by Underwriters Labora tories^ for gauging hazardous liquids-- fire^hd' labor hazards cut down. LIQUIDOMETER--THE 100% AUTOMATIC READING TANK GAUGE Liquidometers are self-contained. Large clock-faced dials provide completely automatic readings without the use of pumps, valves, elec trical-energy, or other outside source of power, and they are not affected by specific gravity -.differences. They will gauge practically any liquid that will flow, light or heavy. Used on fuel oil tanks in residences, apartments, public buildings, indus trial plants, U. S. Army and Navy air and water craft, on freight and passenger vessels, and for other liquid gauging requirements. Direct Reading Models are used where remote reading is not Liquidometer Recorder required. On this type, the dial indicator is located on the tank itself, and a metallic bellows is used to seal the indicator from the tank, thus preventing escape of liquid, gas or pressure. Models are available to automatically control pumps, motors, signals or other devices for maintaining desired minimum or1 maximum liquid levels. LEVELOMETER TANK GAUGES (HYDROSTATIC) Levelometers utilize the principle of hydrostatic balance between the head of liquid to be measured and a dial indicator--there is no liquid in the indi cator to expand or contract and create error. Dial indicators have large graduations and figures and, if desired, one dial indicator can be arranged to gauge a group of tanks. In this instrument the tank liquid traps and com presses air in an "air chamber"--the pressure de pends upon the height of liquid in the tank, and this Master Model pressure is transmitted through tubing to a metal Levtlometer bellows in the indicator unit; the slightest movement of the bellows operates the dial indicator. As air is required to insure correct readings, a manually operated pump is generally supplied, but, where compressed air is available, a valve may be substituted lor the pump, thus providing a continuous reading gauge. Levelometers are made in a number of different models to suit various tank capacities and desired dial calibrations. Models for tanks under pressure also are available. i: W welcome the opportunity to make recommendations for perplexing liquid level gauge problems. 1005