Document a528eegRK580zgJrxaLjzg9B
DOW CHEMICAL U.S.A.
August 26, 1977
LOUISIANA DIVISION PLAOUEMINE. LOUISIANA 707S4
SO* 38S-8000
Don Smith Inland Marine and Terminals
NOISE SURVEY ABOARD TOWBOAT LEVITICUS
The requested noise survey was conducted July 29, 1977 aboard the Towboat Leviticus on the Mississippi River near Plaquemine, Louisiana. The survey was conducted to determine existing noise levels and to establish which areas require hearing protection.
The walk-through survey was conducted with a Bruel and Kjaer Sound Level Meter, Type 2205, which was calibrated prior to beginning the survey. Immediately following the survey a calibration check was performed which proved satisfactory. The readings obtained were on the "A" scale and slow response setting. Both engines were operating and one empty barge was being pushed upstream as the readings were obtained.
The diesel engines proved to be the significant noise source. The high noise level emitted by the engines adversely affected the work deck area near the engines' exhaust, the deck area above the engine room, the engine room itself, the generator room directly in front of the engine room and the stairway leading into the engine room (see attached sheet), The high noise levels recorded during the survey require that anyone working in the engine room, while the engines are running, or in the areas described above must wear hearing protection.
Caution signs must be prominently posted in the designated noise areas. They should measure at least 14 inches by 20 inches (14" x 20") with black letters on a yellow background. The letters should be large enough so that the sign is clearly legible to anyone entering the area. The sign should state that it is a high noise level area and that hear ing protection is required.
If we can be of any further service, please call Charlie Halphen at extension 1659 or myself at extension 1635.
Dannie Kennedy Industrial Hygiene
eg Attachment
AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY
DO 011797 CONFTDFNTIAl
SOUND LEVEL READINGS (dBA) TAKEN ABOARD THE LEVITICUS
Engine Room
110 - 114
Deck Area above Engine Room
110 - 112
Generator Room {directly in front of Engine Room)
102 - 107
Stairway leading into Engine Room
90 - 110
Engine Exhaust on Work Deck
98 - 102
DEK 7/29/77
DO 011708 conftofnttm