Document a4j6KKgE6k6NzoEJ7DrnyEx2N
ELEMENTS OF INDUSTRIAL TOXICOLOGY
on which TLVs are based, are discussed in the preface to and Appendix C of Table 40-B
The TLVs in some cases have the nota tion "skin" following the name of the sub stance If skin absorption, mainly from liquid contamination, cannot be made neg ligible, a reduction in the TLV should be made to maintain the total body absorption of the harmful material at a safe level
Maximal acceptable concentrations
The American Standards Association (ASA) publishes the Z37 senes of maximal acceptable concentrations (MAC) for a number of substances MACs are expressed in ppm and in mg/cu m or milligrams per liter (mg/L) Up until about 1965, the definition of MAC was essentially identical to the TLV of the American Conference of Governmental Industrial Hygienists Since that time the Z37 Committee of the Amer ican Standards Association has reviewed and revised earlier standards and their defi nition of MAC (Table 40-C)
The maximal acceptable concentrations are peak concentrations, not averages, and should not be exceeded during a normal workday Any variation in concentration should be below the recommended level
The meaning of MAC is discussed in the preface to Table 40-C
Application of the values
Many individuals refer to published TLVs and MAC'S for a black-and-white value to he used in a specific situation and overlook the important qualifications of these values set forth by the organizations establishing them
The preface to the annual list of TLVs (Table 40-B) and the introduction to each of the American Standard Z37 Senes of MAC'S (Table 40-C) provide the'complete explanation of the concepts on which these values are based To intelligently |udge which of the two concepts should be applied in a specific situation requires knowledge of the type of injury that would result from dangerous exposure
Adverse toxic effects may he broken down into four major classifications (1) acute toxicity, (2) chrome toxicity, (3) narcosis, and (4) discomfort
The time-weighted average concentration
(TLV) would be the appropriate guide where acute systemic or chronic toxic ef fects would result from overexposure When protection against narcosis is required, the concentrations should never exceed some peak value as given by the MAC To mini mize discomfort, the instantaneous or peak concentrations are of interest
Both the ASA and the ACCIH, in defin ing their respective values, point out that an understanding of the criteria on which the values are established is necessary m decid ing how to use the value
The ASA, for instance, lists a MAC of 25 ppm for carbon tetrachloride, but notes that fluctuation should be around 10 ppm, which notation introduces the time-weighted concepts on which TLVs are based
On the other hand, the ACCIH has desig nated certain "ceiling" values not to be ex ceeded even for short periods of time and thus have to Some extent adopted the maxi mum limit concept on which MAC'S are based
It should be remembered that TLVs and MACs are, even though applied as intended, relative values The concentration that just approaches the threshold limit value is just as hazardous as the one that slightly ex ceeds it There is no magic line that can be drawn to provide complete safety
In general, it is desirable to maintain air contamination at the lowest possible level Probably the greatest misuse of both TLV's and MAC'S is the practice of comparing toxic substances by a ratio of their respec tive MAC or TLV These values cannot be used as relative indexes of toxicity
It should also be remembered that Deither the TLV nor MAC should be considered the sole criteria of suspected occupational disease The ASA specifically states that its MAC values are intended to serve as stand ards of good practice and as engineering guides, and are not intended as legal re quirements The same thought is implied in the preface to ACCIH values
It is highly advisable that the documented justification for the threshold limit value be consulted for detailed information concern ing mode of action and effect of exposure to a particular material Such information is given m the references listed at the end of this chapter, particularly the ACGIH's
(Text continues on page 40-13 )
40-3