Document a4gMNaV25QNw5DBzLON6rjV1b

American Society of Heating and Ventilating Engineers GuiDEigjy Chapter 25--Boilers tube or water tube; second, with regard to arrangement of furnace flues, as (1) horizontal return tubular (HRT) boilers, (2) portable contained) firebox boilers with either water or fire tubes, and (3) w t" tube boilers of the power type. ter Fire tube boilers are constructed so that the water available to produ steam is contained in comparatively large bodies distributed outside of th* boiler tubes, the hot gases passing within the tubes. In water tube boiler the water is circulated within the boiler tubes, heat being applied ternally to them. ex' The HRT boiler is the oldest type and consists of a horizontal cyi;n drical shell with fire tubes, enclosed in brickwork to form the furnace and 14,Table 1. Practical Combustion Rates for Small Coal-Fired Heating Boileb Operating on Natural Draft of from in. to J4 in. Waters ls Kind of Coal No. 1 Buckwheat Anthracite Anthracite Pea Sq Ft Grate Up to 4 5 to 9 10 to 14 15 to 19 20 to 25 Up to 9 10 to 19 20 to 25 L Sqb of Coal pbb Ft Grate per Hour 3 3M 4 4H 5 .5 ' 6 h higher rate of evaporation per square foot of heating surface, with setting, baffling and draft. Water tube boilers used for heating iprP~ses are brick set, supported on structural steel columns and have the >;Pu.rv)ggtting encased in an insulated steel housing to prevent air infiltra- ^and to minimize heat losses. For large heating loads at a high rate of `^ooration, sucf1 boilers should be operated at pressures above 15 lb per . evap0- inch with a pressure-reducing valve on the connection to the ''square heating main. SPECIAL HEATING BOILERS A special type of boiler, known as the magazine feed boiler, has been developed for the burning of small sizes of anthracite. These are built of both cast-iron and steel, and have a large fuel carrying capacity which results in longer firing periods than would be the case with the standard types using buckwheat sizes of coal. Special attention must be given to insure adequate draft and proper chimney sizes and connections. ' Oil-burner boiler units, in which a special boiler has been designed with a furnace shaped to suit the particular burner used, have been developed /by a number of manufacturers. These usually are compact units with the burner and all controls enclosed within an insulated steel jacket. Ample -furnace volume is provided for efficient combustion, and the heating "surfaces are proportioned for effective heat transfer. Consequently, /higher efficiencies are obtainable than with the ordinary coal fired boiler converted to oil firing. Anthracite Nut and Larger Bituminous Up to 4 5 to 9 10 to 14 15 to 19 20 to 25 Up to 4 5 to 14 15 and above '. 8 9 10 11 13 9.5 12 15.5 in this table. ,$ combustion chamber. All heating surfaces and the interior of the boiler are accessible for both cleaning and inspection. Horizontal return tubular boilers, especially the larger sizes, should be suspended from structural columns and beams independent of the brick setting. Small HRT boilers sometimes are supported by brackets resting on the brick setting. Portable firebox boilers are the more generally used type of steel heating boilers, their outstanding characteristic being the water-jacketed firebox which eliminates virtually all brickwork. They are shipped in one piece from the factory and come to the job ready for immediate hook-up to piping. They may be of welded or riveted construction and have either water or fire tubes. Manufacturers' catalogs usually list heating surface as well as grate area. The elimination of brickwork also makes this type the most compact of steel boilers as well as the lowest in first cost. Water tube boilers. For large heating loads water tube boilers are quite frequently used. They usually require more head room than other types of boilers but require considerably less floor space and make possible a ?: GAS-FIRED BOILERS V Gas boilers have assumed a well-defined individuality. The usual boiler ,is sectional in construction with a number of independent burners placed beneath the sections. In most boilers each section has its own burner. In all cases the sections are placed quite closely together, much closer than would be possible when burning a soot-forming fuel. The effort of the designer is always to break the hot gas up into thin streams, so that all iparticles of the heat-carrying gases can come as close as possible to the heat-absorbing surfaces. Because there is no fuel bed resistance and because the gas company supplies the motive power to draw in the air necessary for combustion (in the form of the initial gas pressure), draft losses through gas boilers are low. HOT WATER SUPPLY BOILERS Boilers for hot water supply are classified as direct, if the water heated passes through the boiler, and as indirect, if the water heated does not come in contact with the water or steam in the boiler. Direct heaters are built to operate at the pressures found in city supply mains and are tested at pressures from 200 to 300 lb per square inch. The life of direct heaters depends almost entirely on the scale-making properties of the water supplied. If water temperatures are maintained below 140 F the life of the heater will be much longer than if higher temperatures are used, owing to decreased scale formation and minimized corrosion below 140 F. Direct water heaters in some cases are designed to burn refuse and garbage. 406 407