Document a4ODO9m27oG3G7MQJRkKBOdwY

r%._v u i ^.L.r.iJX i ' FEB 13 '91 1507 IRI CGO 454 a ; ndustrial ^isk LOSS PREVENTION SURVEY CONFIDENTIAL usurers This report should he made available only lo authorized parsons. 4 1 CDOQfc<l04 ; h x X P. 11 ^vexview B. F. GOODRICH COMPANY B. F. GOODRICH CHEMICAL GROUP GEON VINYL DIVISION 2104 EAST 223R0 STREET CARSON, LOS ANGELES CO., CA 90745 BY: $< 0. Humphrey DATE: Sept. 24, 1990 L0C.I0: 800083/902746 HRS: 4 CONFERRED With: iHr. Wayne Smith, $af. Coord. RECOMMENDATION UPDATE NEW*: None COMPLETED: 85-1 (PCB Transformer) 89-2 (Automatic sprinklers) (90-0) RECOMMENDATIONS 87-4 NEW TOWER/OLD WAREHOUSE B: (Revised 10/16/89) Arrange and protect tbe new four (4) story tower structure and the revisions to the south 9300 ft2 (865 m2) of the Old Warehouse B for the manufacturing of both flexible and _ rigid PVC resin as follows: (No plans at the local level; if decisions were to be made, they would be done at the corporate level) a. AUTOMATIC SPRINKLERS: Reinforce the existing system in the south 9300 ft2 (865 m2) of Warehouse B to provide 0.25 gpm/ft2 (10.2 L/min2) over any, including the hydraulically most remote 3000 ft2 (279 m2) of floor area using 17/32 in. (20 mm) nominal orifice, 286F (141C) sprinklers. RSVP* PLANS** b. AUTOMATIC SPRINKLERS: Extend existing sprinkler protection in the new tower structure to cover the 10 ft x 10 ft (3.1 m x 3.1 m) elevator equipment room. RSVP* ^ c. SPRINKLER RISER: Provide a separate sprinkler riser for the four-story tower structure. (When system was originally installed the Los Angeles County Fire Department did not see the need for a separate riser) o O h4 89-1 FIRE EQUIPMENT MAINTENANCE: Improve overall protection by excercising all fire protection valves by fully closing and re-opening. Lubricate as necessary. Conduct on a bi-annual basis and record any descrepancies. File for review by this Association. The 2 in. (51 mm) drain test.should be conducted after excercising the valve. (Will implement on a bi-annual basis) 89-3 WATERFL0W ALARM SWITCHES: Relocate the local waterflow alarm switches on the north compounding and dryer sprinkler risers to above the alarm check valves. (Will attempt to comply) RSVP* LMD/2653D AS PFtC/T RM PEP ws 1 SUPR ru HPS PCB \kS \ASN CNSTi CNSTS CNST3 CWST4 7 6 7 9 2G !G 6G 00 0000 90 10 0 82 0 18 BpGS0847 occ j FSO CPC 1 91 74 TV* u madeJar piopfiy luwwf purpose* only and is bosed upon condition! and practices observed and information made atollable al ike lime ofoiii review. It dors not purport to list at! baiords no> to utdicatr that other hatardi do not exits. No responsibility n astumnl/at Ihr control o' eotrecnon vfvenditions or prattlers exiuimg or ike insured premises. IRI SpttlftcaKy disclaims any tmeranty a* -qt -- - failure--1 mrtik oJmt* WvnX Wiii m*I A* + O* sof* C*r htallhjuL, Of k* lAr Of you ho** aii*r**w pUoi* u$ with few* /vir. <M Ifth*r* Art Of\? C&*c*rmr\ "FEB 13 '91 15:0? iri CGO P. 12 i. F. GOOORICH COMPANY 2 800083/90Z746 SIGNIFICANT CHANGES The alarm system is to be upgraded. A master fireboard will be installed in the Lab Office, No other information is available at this time. A new 80 ft x 158 ft (24. 4m x 48.2 m) warehouse will be constructed alongside Warehouse A and Warehouse C (Building No. 815). It is to be of light noncombustible construction. Storage is to be PVC pellets In Gaylord containers. Current storage height of this product in the facility is to 10 ft (3.1 m). Plans are to be submitted to IRI. The tanks currently in this area are to be moved south of the Lab Building. COMMENTS RSVP*: The completion of this recommendation will involve an impairment of your fir,,e protection. Please notify the IRI's Los Angeles Office, 505 South Main Street, Suite 750, Orange, CA 92668, (714) 835-7778 at least 48 hours before starting this work. PLANS**: Completion of this recommendation requires the review and acceptance of detailed working drawings and necessary supporting calculations. All fire protection equipment should be listed by a recognized testing laboratory. All installations should be designed in accordance with applicable NFPA Standards unless modified by an IRI interpretation guide. Duplicate sets of drawings and specifications should be sent to IRI's Los Angeles Office, 505 South Main Street, Suite 750, Orange, CA 92668 for review. IRI's acceptance should be secured before construction or installation begins. Recommendation No. 84-4 was removed as non-applicable. The rooms have been sprinklered. Pre-emergency planning (overview) and the RSVP impairment notification program were discussed with Mr. Smith and are considered acceptable. ^00 LMD/2653D BFG50848 RC0 BYXEROX TELECOPIER 7010 ; 2-13-fx 'FEB 13 '91 15:08 IRI CGO P. 13 RISK: B. F. Goodrich Co,_____________________________ LOC ID: 800083/902746 WATER SUPPLIES & TEST RESULTS SUPPLY DESCRIPTIONSGPM 1-8" conn, to 10" DE main FLOW IOC _ STAT RSD RE$Q LOC DATE 1-8" conn, to Arco Refinerynormal ly closed 1-8" conn, to Monsanto Chem.- 1210 normally closed Hydt. No. 4 88 58 Hydt. No. 3 9/24/90 SJH 2G41i.-003 N20C Rev. 8/82 LMD/2653D BFG50849