474 CHAPTER 32 1960 Guide for a heat loss of 78.5 Btu = 49 deg, which corresponds to-the surface temperature of 129 F last assumed. The heat loss is therefore 785 X 8532 -s- 3512 = 202 Btu per sq ft of pipe surface. Since the surface area per linear foot of 6-in. pipe is 1.734 sq ft (Table 2), the heat loss per linear foot of pipe will be 202 X 1.734 = 351 Btu per hr. The rate of heat loss from a surface maintained at constant temperature is greatly increased by air circulation over the surface. In the case of well-insulated surfaces, the increases in losses due to air velocity are very small as compared with increases from bare surfaces, because of the fact that air flowing over the surface of the insulation can increase only the conductance of heat from surface to air, and cannot change the internal conductance of the insulation itself. The maTimnm increase in heat loss due to air velocity ranges from about 15 percent in the case of 1-in. thick insulation, to about 5 percent in the <=*-* of 3-in. thick insulation, provided that the insulation is thoroughly sealed so that air can flow only over the surface. If the conditions are such that the air may circulate through cracks and crevices in the insulation, the increases may be far greater than those given. Therefore, it is essential that insulation be applied in such & manner that air circulation within it, or between it and the pipe, is avoided. Piping which is covered with a water-mixed product or insulation which will absorb moisture, particularly in damp locations, should be coated with a corrosion-resistant paint. This precaution may prevent early failure due to external pipe corrosion. The frequent practice of omitting insulation on that por tion of a pipe which passes through a masonry wall, or which may be in contact with other metals, should be avoided. Physical contact between the pipe surface and other struc tural materials of high thermal conductivity will result in heat transfer much greater than that shown in Tables 2 and 3 for transfer from bare pipe to air. The saving due to use of insulation on piping is illustrated in Example 4- Example 4: If the steam pipe given in Examples 1 and * is covered with nominal 1 in. thick 85 percent magnesia, determine the resulting total annual loss through the insulation. Also com pute the monetary value of the annual saving and the percentage of saving over the heat loss from the bare pipe. Solution: By referring to Fig. 1, the coefficient for 1-in. insula tion on a 2-in. pipe is found to be 0276 Btu per (hr) (linear ft of pipe) (deg temperature difference) at a temperature-difference of 159 4 F. The heat insulation factor for 85 percent magnesia insulation, interpolated from Table 6, for a temperature differ ence of 159.4 F, is 10S5. The total hourly loss per linear foot of pipe will then be 0276 X 159.4 X 1085 = 47.7 Btu. The total onnml loss through the insulation -- 47.7 X 165 (linear ft) X (4000 hr) -- 31,480 Mb. The annual bare-pipe loss as determined in the solution of Example 1 was found to be 171,100 Mb. The saving due to insulation is then 171,100 -- 31,480 -- 139,620 Mb per year. From the solution of Example t, it was found that the heat supplied to the system cost 80804 per 1000 Mb. Therefore, the monetary value of the saving = 0804 (dollars) X 1396 (thousand Mb) -- $11223 or 8J6 percent of the cost when using uninsulated pipe. THICKNESS OF INSULATIONS TO BE APPLIED principal object of the insulation is to limit the heat gain or loss to a specified value to control the temperature of a manu facturing or chemical process. Minor refrigeration and air-conditioning equipment and cold-water lines usually utilise only sufficient insulation thick ness to prevent condensation on the warm surface so as to prevent dripping. Occasionally the criterion for heated equip ment and pipes is the reduction of the outer surface to a tem perature (usually a maximum of 175 F to 200 F) low enough to prevent injury to personnel. ECONOMICAL THICKNESS OF INDUSTRIAL INSULATION Where a thorough analysis of economic thickness is desired, the of insulation that will give the lowest sum of annual cost of heat loss and insulation may be found by means of Fig. 6.* As the thickness of insulation increases the annual cost of heat loss decreases, but the annual cost of insulation (first cost multiplied by percent fixed charges) increases. The mm of the two costs will first decrease with increasing thickness of insulation, and then, depending on operating condi tions, will increase beyond a certain thickness. Therefore, the at which the sum of the costs is a minimum, is the most economical. The method of "ring the chart Fig. 6 is as follows: From the number of hours of operation per year at the bottom of the chart proceed upward to the line showing value of heat in dollars per million Btu using the appropriate scale A or B. Proceed right to temperature difference line using either scale A or B. Move upward to the line representing conductivity of the insulation being considered, then left to discount line, upward to the percent fixed charge line, right to the pipe rise or flat surface line and read the economic thickness at top on the scale corresponding to the scales se lected for value'of heat and temperature difference. For ex ample; with Scale B heat value and Scale A temperature difference or vice versa, use Scale A-B economic thickness. If the intersection with the flat surface is on the fiat surface continued curve, the economical thickness is read on the prime scales A'-A', A'~B', or B'-B'. Cost of insulation refers to incremental cost in place; i-e., average m<rpjTT*nt.gl cost per unit thickness after the first unit. The first inch of insulation will usually cost more than each additional inch. This is due to cost of finish, contractor's setup, and operating costs, which do not increase in pro portion to thickness. The first inch of insulation, except in very unusual cases, provides enough saving in heat cost out of bare surface cost to more than cover these extra first costs. To obtain discount from insulation list price, first obtain applied prices for the desired type of insulation in one-inch, two-inch, etc., thickness. Then determine the average incre mental cost per inch above one-inch thickness. Incremental cost in percent discount from list is 100 (*-?) Thermal insulation is used in a variety of thicknesses for many varied reasons. Refrigerating equipment is nonnally designed for minimum heat gain, and heating equipment for minimum heat loss, within economical limits. This assures minimum-sized refrigeration or heating equipment, both from the standpoint of original as well as operational cost. Present refrigeration design practice limits the heat gain to 4 to 8 Btu per (hr) (sq ft) of exposed surface. Sometimes the where X - average incremental cost in place per inch above one inch. Y * list price for one inch. In figuring pipe insulation, use the list price for one-inch thickness for a pipe rise consistent with the average incre- Industiial Insulation 475 mental cost per inch. For example, if the average incre mental cost per inch is based on applied prices for one, two, and three inches, the incremental cost of the second and third inches would be averaged and the pipe size for list price would be that nearest the average pipe size of the second and third inch. A rapid method for determining the economical thickness of insulation by use of tables has been published* LOW TEMPERATURE PIPE INSULATION Surfaces maintained at temperatures lower than the sur rounding air are insulated to reduce the flow of heat and to prevent condensation. The insulating material should absorb a minTmtim amount of moisture, because the absorption of moisture substantially increases the conductivity of the ma terial. This property is particularly important in the insula tion of surfaces that are below the dew point of the surround- ing air. In such cases, due to vapor-pressure difference, it is necessary to seal the surface of the insulating material against the penetration of water vapor which would condense within the material, causing a serious increase in heat flow, possible breakdown of the material, and corrosion of metal surfaces. An insulating material with a high degree of moisture absorp tion might pick up moisture before application and then, when the vapor seal is in place and the temperature of the insulated surface reduced, release that moisture to the cold surface. There are a number of methods of producing vapor seals, some of which have been worked out by insulation manufacturers to suit their products, and others by appliers and users. Unless time-proven methods are known, specifica tions of insulation manufacturers should be obtained and followed carefully. Equipment must be carefully protected against corrosion caused by condensation of water vapor. All metallic surfaces ZO Solve problems o* indicated by doffed Roe, entering chart at lower left-hand tcde. Fig. 7 .... Thickness of Pipe Insulation to Prevent Condensation on Outer Surface1