Thank you for calling to inquire about the 3M Brand Hydrogen Fluoride Respirator #8706. As we discussed, the 8706 was tested in our laboratory at a concentration of HF gas of 10 ppm and an airflow rate of 16 1pm. Under these conditions, breakthrough of 3 ppm (the current TLV) did not occur for four hours. Also, from published reports, the threshold detection level for HF gas is significantly less than 3 ppm.
Use of air purifying respirators against HF gas is controlled by OSHA Program Directive #300-9 since there are no NIOSH/MESA approved respirators. I've enclosed copies of the cover sheet and page 18 from #300-9 as further explanation. HF gas does have nuisance properties below 1 TLV of course, and use of any respirator including the 8706 is not controlled for such exposures. For use above 1 TLV, #300-9 spells out that the employer is to justify the use of unapproved respirators where no approval schedule exists. In the case of HF gas, this justification could take the form of both respiratory and eye protection depending on exposure levels. Use of the 8706 with or without chemical goggles may play a part in your protection plans.
I hope the above information is of assistance in your determina tion of 8706 acceptability.
Sincerely,
Technical Service Occupational Health &
Safety Products Div. 3idg. 230-B
LFS/hv Enclosures
miNNESDTA HI ! HI H G AND tP. A N U F A-C 7 cl. H IMG II U IT! r1 A N Y
ARD 004279
U.3. i o:'
Occupational Safety and Health Administration
WASHINGTON. D.C 20210
:rf j'+wi St 3
//
\
OSHA Program-Directive #300-9
,To: Field and National Qfflces/QSH t Subject: Addition to the Industrial Hygiene Field
Operations Manual {IHFOM)
1. Purpose. The purpose of the directive is to forward an add?tlon to the IHFOM - Chapter XII.
2. Documentation Affected. None.
3. Background. This addition describes the method for Investigation of respiratory .protective equipment programs in workplaces where employees are exposed to air contaminant hazards. To provide supplemental knowledge, every CSHO should attend a respirator training course recognized by OSHA and should read the NIOSH publication 76-189, entitled "A Guide to Industrial Respiratory Protection" (a copy is being supplied to all Area Offices by the Technical Data Center).
4. Action. Place this chapter XII into tne IHFOM directly after Chpater XI.
5. Effective Date. This directive is effective immediately and shall be retained until further notice.
Eula Bingham
Assistant Se fetary Occupational Sa fety and Health
DISTRIBUTION:
A-l . B-2 C-3 D-4&5 Training Institute
Originator: OT
E-l HEW-1 NIOSH Regional
Direc tors-1 NACOSH-1
Program
ARD 004280
SUBSTANTIAL PROTECTION: The 3M Brand Hydro gen Fluoride Respirator gives excellent relief. for cocut four hours, from discomfort of nonhazardous concentrations of hydrogen fluoride gas.
CONSTRUCTION: This respirator is lightweight, sand wich construction with chemical additives. The whole respirator is the filter.
COMFORT:' Comfortable to wear and easy to breathe through. Weighs less than one ounce.
COST: Reusable but low cost allows respirator to be discarded after one wearing. No maintenance, sanitary.
VISION: Respirators were fitted to test subjects, reads were held straight, and subjects were asked to point out all areas of a numbered grid on the floor wnich were not obscured from view.
Respirator
Angle from center line
0* (straightahead) 30* 60* 90*
3M 8706
3.0
2.5 3.0 3.5
Competitor A 5.5
3.5 3.5 4.0
Competitor B 6.0
4.5 4.0 4.0
Competitor C 3.5
5.0 4.0 3.5
Competitor D 4.0
3.5 3.5 3.5
Competitor E 8.0
4.5 4.0 4.0
Competitor F 4.0
4.0 3.5 3.5
For use against nonhazardous levels of Hydrogen Fluoride. Effective against 10 ppm HF at an air flow rate of 16 Ipm for four hou* Filters out 98% of particulates having a mean diameter of 0.4-0.6 Lightweight, less than 7 grams.
IOHSM70W5ISSI )R2
ARD 004281
-18-
c. For asbestos, either Bureau of Mines or NIOSH/MESA approved respirators for asbestos dust are adequate, 29 CFR 1910.1001(d)(2). For vinyl chloride, only NIOSH/MESA approved respirators can be used, 29 CFR 1910.1017(g)(2).
e. For pesticides, NIOSH/MESA approved respirators. f. For health standards of specific air contami
nants promulgated after the vinyl chloride standard, the standard itself contains the appropriate approval .authority. Unapproved respirators can be used only if MESA/ NI0SH does not have a test schedule for the specific air contaminant, such as mercury vapor and the combination of acid vapor and high efficiency particulate filter. The employer has to justify the intended purpose of such devices and demonstrate that the respirator can provide the protection required. If OSHA concurs, then the respirator is considered as "accepted" as in 29 CFR 1910.134(b)(11). The CSH0 shall contact the National Office of Technical Support for assistance.