Document a457Mr5ZBYRm5qmxOV6yRyyM
The Finding of Chlorinated Dihenzofurans in n Japanese Polychlorinated lJiphenyl Sample
by John A. G. TIoach and Ik win II. Pomehantz
Division of Chemicul Technology f ood ana Drug Administration Washington, D.C 20204
The presence of tetra- and pentochlorinated dibenzofurans and hexa- and heptachlorinated naphthalenes in two samples of polychlorinated biphenyl mixtures (PCB) of European origin has been reported by VOS et al. (1970a). Their interest in a content analysis of the two PCB samples for impurities was stimulated by previous work in which toxic effects observed in chicks were attributed to these two samples (VOS et al., 1970b).
Kanechlor 400 (KC-400), a commercial PCB preparation of Japanese origin, has been identified as the causative agent of Yusho, a human poisoning incident resulting from the ingestion of rice oil contaminated with KC-400 (KUKATSUNE et al., 1972). We have analyzed a sample of KC-400 made available to us from the Xanegafuchi Chemical Industrial Co., Ltd. through Or. H. Blumenthal of the Food and Drug Administration to determine whether potentially hazardous chemicals, particularly chlorinated dibenzofurans (Cl-OBF). were present as contaminants. It was the objective of this analysis to obtain, where possible, structural information on these contaminants and an estimate of their con centration in the KC-400.
, '
> '
:
Experimental
A hexane solution of the KC-400 was gas chromatographed, using an electron capture detector, on a column of 80-100 mesh Chromosorb WHP coated with 107. DC-200 and on a column of 157. QF-1 and 107. DC-200 each coated separately on 80-100 mesh Cbromosorb VHP and mixed in a 1:1 weight ratio. The KC-400 (chlorine content 487.) showed only minor differences in peak locations and relative peak heights from Aroelor 1248 (chlorine content 487.), a PCB of American manufacture. Therefore, Aroelor 1248 to which a reference mixture of di-, tri- and tetrachlorinated dibenzofurans (prepared by chlorination of dibenzofuran In tetrachloroethylene with Iron powder as catalyst) had been added, was used by Porter to devise a procedure to separate Cl-DBF from PCB (PORTER, 1971b). This procedure, as used In the present study, is outlined in Figure 1.
338
KuilrUr. <*
Coni.nmm (t-n i Tf'iirelecr.
Vol. 17. Nu. 3 V J78 br Sprisfr-V.rls N.w York Jnt.
HONS 081537
KC-AOO in hexane solution
Florisil Column
PCB In eluate A (discard)
Cl-DBF In eluatc B
Alumina Micro Column (POUTER, 1971a)
rCB In eluate 1 (discard)
Cl-DBF In eluate 2
Figure 1. Proccduro for Separation of Chlorinated Dlbenzofurans from Chlorinated Biphenyls in KC-400
The Florisil (8 g of 60-100 mesh PR grade) was activated by heating at 130*C > 12 hr and cooled to room temperature in a desiccator. Before the sample was added to the column, the Flor isil column was prewashed with about 25 ml hexane. The KC-400/ hcxano solution (< 2 ml) was placed on the Florisil, which was contained In a 10 am l.d. x 300 erm glass column fitted with a Teflon stopcock and medium porosity fritted disk. The column was eluted with two eluants in succession at the rate of about 5 ml/ min. Eluant A was 150 ml hexane. Eluant B was 100 ml 5% ethyl ethor In hexene. Elunte B was concentrated to about 1 ml before the sample was placed on the alumina micro column.
The micro column was a disposable pipet of roughly 5 mm bore Into which a small wad of glass wool had been Inserted to retain the aluminum oxide. Merck alumina, which had been heat-activated exactly like the Florisil, was poured into the column to a depth of 2.5 cm. Sample or eluting solvent was then added to the column from a disposable pipet or a large glass syringe. Eluant 1 was 10 ml IV. methylene chloride in hexane; eluant 2 was 6 ml 207. methylene chloride in hexane. Additional PCB was removed by con centrating eluate 2 to about 1 ml and subjecting it to a second
339
"yyy
m
i8
.-.'SK
v i:; :
.
1
1 nab; : Vo v
a* ..
(-
AS.
MGNS 081538
$te^^ii'fielrl V vp *! ..jigj*,TO' Si M
Kjfofl
x>;,a.
alumina micro column cleanup, simply repeating the alumina column procedure.
This procedure was first applied to duplicate 2 mg portions of KC-400, Electron capture gas chromatography of eluate 2 showed a gas chromatographic peak In each sample that had a relative retention time matching that of a tetrachlorodibenzofuran on both a 10% OV-101 and a 1:1 10% DC-200 + 15% QF-L column under the following conditions: glass column, 6 ft. x 4 mn Id., column temperature 200*0, injection temperature 225*C; carrier gas, nitrogen at 120 ml/roin.; detector, tritium source (concentric type), operated in electron capture mode at 210#C. Detector voltage was adjusted so that 1 ng hcptachlor epoxide causes 1/2 full scale recorder deflection at 1 x 10"^ AFS.
The reference material for this retention time comparison was the tetrachlorodibenzofuran component in the mixture of chlorin ated dlbenzofurane.
To obtain sufficient materiel from the KC-400 for combined gas chromatography/mass spectrometry (CC/KS) analysis, the pro cedure was scaled up to permit cleanup of 8 mg portions of KC-400. Cleaned up eluatea (eluate 2) were then combined to give two composite samples, each equivalent to approximately 100 mg KC-400. These two composites were analyzed by GC/MS (Finnigan 1015 quadrupole mass spectrometer) and the resulting data were examined for evidence of the presence of compounds that were not chlorobiphenyla. A reagent blank of equivalent site was also analyzed by GC/MS. Hie reagent blank contained none of the compounds found In Che samples. The qualitative results of the KC-400 analyses are sunmarized in Table 1. The Identification of the compounds listed in Table 1 was based on a comparison of the mass spectra of the sample compounds with the mftss spectra of the di-, tri-, and tetrachlorinated dibenzofuran components in the reference mixture and on comparison with mass spectral data on chlorinated dlbsnzofurans in the published literature (VOS et al., 1970a; FIRESTONE et al., 1972; PLIMKER et al., 1973).
The amount of tetrachlorodibenzofuran contained in the reference mixture was approximated by comparing Its mlcrocoulometric GC response with the response given by a known quantity of a tetrachlorodibeneodioxln of known structure. The tetrachlorodlbenzodloxln was considered an appropriate microcoulometric reference compound because of its structural similarity to tetrachlorodibenzofuran. The electron capture GC responses of the tetrachloro component in tha synthetic mixture and in the KC-400 extracts were then compared to quantitate the tetrachlorodibenzo furan in the KC-4(. - The KC-400 was estimated to contain approximately 1 pp.n tetrachlorodibenzofuran.
MQNS 061539
-i- > *'^ -\ A, '\' ,..* ',
mmMSMsmmsmmmHiV'-V#I':'?'*'.' ov , ", j> '
TABUS 1
Compounds Present in Kanechlor 400 After Cleanups
Mass (No. of Cl) end yraumcnlaUon Date
Compound Present
Molecular Weight of Compound
256(3Cl);H-2C1
trlchlorobiphenyl
256
- Viti1" ' ' V. * ,0 . .
m Kill
%-xfv
270(3C1);M-(C0+C1) trlchlorodlbenzofuran
270
290(401) ;M-2Cl
tetrachloroblpheny1
290
298(5C1);M-2C1
pen tael) loronaplithalene
298
304 (4CI) ;M- (C(HC1),
M- (COf3Cl)
tctrachlorodibenzofuran
304
312(501);M-C1
unidentified; perhaps mcthylpentechloro-
nophthalene or pentachlorophenyl cyclopentadiene
338(4 or 5C1); M-(CO+3Cl) indi cated
possible pentachlorodlbenzofuran
338
^Listed In order of elution from 3% 0V-101, 6 ft. x 2 n l.d. glass column at 220*C, carrier flow 20 ml He/mln.; the taste MS evidence was found in both samples examined for all entriea but the last (possible pentaehlorodlbentofuran) for which a second determination was not attempted.
x - .* * -J
Summary
Chlorinated dibensofurans,. including 1 ppm of tetrachlorlnated dlbenzofuran(s), and pentachloronaphthalene have been identified by combined gas chromotograpliy/oass spectrometry In a polychlOTlneted biphenyl of Japanese manufacture (KC-400). The question of whether chlorinated dlbenzofurans In KC-400 may have contributed to the reported Yusho incident la thus raised.
Acknowledgement
fv* <:v*
Hie authors wish to thank Sandra Mercier for assistance in the preparation of the samples for CC/MS analysis. The reference mixture of di-, tri-, and tetrachlorlnated dlbenzofurans was kindly provided by Dr. Albert Poll land, Food and Drug Administration.
References
FIRESTONE, D., J. RUSS, N. L, BROWN, R. P, BARRON, and J. N. DAMICO: J. Ass. Offfc. Anal. Chem. 55, 85 (1972).
OBIS'*0 HONS
'; ; ^>C;J-`S' v
n ** v v5r'-.,> vivA^W' .-:*.
-.-
-.,,_..
.r....
$',! >
, ,.,...^
... .. , .v
KURATSUNE, M., T. YOSHIMURA, J. MATSUZAKA, and A. YAMAGUCH1: Environ. Health Perspect. Issue No. 1, 119 (1972).
PlIMMER, J. R., J. M. RUTH, am' E. A. WOOLSON: J. Agr. Food Chem. 21, 90 (1973).
PORTER, M. and J. A. BURKE: J. Ass. Offic. Anal. Chen. 54, 1426 (1971a).
PORTER, M.: Private Communication (Feb., 1971b).
VOS, J. C., J. H. KOEMAN, H. L. VAN DER MAAS, M. C. TEN NOEVER DE BRAUW, and R. H. DE VOS: Fd. Cosmet. Toxicol. 8, 625 (1970a).
VOS, J. C. and J. H. KOEMAN: Toxicol. Appl. Pharmacol. _17. 656 (1970b).
m vli\'3.
r-'.VV'i
942