Document a1rXar5z8Gopy446YM0vmnyMX

ENVIRONMENTAL PROTECTION AGENCY REGION IV SURVEILLANCE AND ANALYSIS OIVI5ION' ATHENS, GEORGIA 30601 *Urj Mr. Sam L. Spencer Chief, fisheries Section Dept. of Conservation and Natural Resources 64 N. Union Street . Montgomery, AL 36130 ' Doer Mr. Spencer: . At long last I have received from Che EPA laboratory in Duluth, ful the results of the PC3 analyses on fish collected in your State in the Spring of 1976. I an enclosing these results along with the method used in preparation and analyses. We do appreciate your cooperation in this study and hope the infor mation can be of use to your staff. If you have any questions, please don't hesitate to call me. Sincerely, W. H. Peltier Ecology Branch Enclosures CCS James W. Warr AL Water Improvement Com. HONS 002602 Sample A r"a Choccolocco Creek, 1 nllc above tlwy 71 bridge In Talladega County near Anniston, AL Dennison Slough Wilson Reservoir, AL Sample Composition 2 Goldfish 4 Cluirmel Catfish 4 Gizzard Shad 1 lic.dcar Sunflsh 4 Larearnouth Cass 3 Gar 6 Gizzard Shad 3 Larci'jnouth ftur.s 3 Kedcar Sunflsh Co din fry. '<' Lnn 'l, 6IL(nA \ bA l./'O A C t J 't. Cl tv * J PCn1:: (ug/gm) 10J5/1ZA1254 10.5 . 78,8 ' 0.26 7.00 CO'O HONS 002603 Methods Preparation of Smrples The fish vere collected by state and federal field crews and siiippcd iiozcn to Duluth. The fish in each sample were homogenized as a composite and given laboratory numbers consecutively from 1 to 58. Sub-samples weighing 30 gm3 and 20 gms were exhaustively ex- . tractcd with a Soxhlct extractor using a 1:1 mixture of hexane and methylene chloride. The 20 ge sample extract was concentrated and placed on a 20 gm Florisll column. The PCBs and related chemicals were eluted, with 250 ul hexane, and the extract was concentrated to 100 ml for initial EC screening. ' The 30 ga sample was concentrated to 100 mg/ral lipids in methy lene chloride for cleanup by gel permeation chromatography. The extract was cleaned up by sequential elution of 5 ml aliquots an a bed of SX-2 Bio Reads (Bio Rad Laboratories) using methylene chloride as a solvent. The combined fractions containing the PCBs were passed through a column containing 15 gtn Cellte 545 Impregnated with 9 mis of 1:1 l^SQ^ and fuming I^SQ^ (30% SO3). The extract was concentrated to 1-3 ml for screening with FID gas chromatography and then CC/HS .* * * analysis. . Electron Capture CLC Analysis The extracts of the 20 gm tissue samples were analyzed for PCBs using n Hewlett Packard 5700A gas chromatograph equipped with s Model 3352B Laboratory Data System, an automatic sampler, and linearized HONS 002604 2 argon-methane detector. The column was a 6 ft. x 1/8 inch (O.D.) gla;3 column packed with 80/.L00 mash Cats Gluon Q coated with 4 percent/ 6 percent SE-3O/OV-210. The column temperature was programmed from 1G0G to 220C at 2C/nin. followed by an 8 min. hold at 220C. The chromatograms were interpreted by a program prepared by Mr. Frank Pugliai of the Environmental Research Laboratory - Duluth in which. 1G reference PCB peaks were monitored. Eight reference peaks corresponded to PCBs found in Aroclor 101G and Aroclor 1242, and eight peaks corresponded to PCBs found in Aroclor 1254. The program estimated the quantity of either Aroclor 101G or 1254 based on the individual peek areas and then determined the mean and standard deviation of the respective mixtures based on all reference peaks found. Peaks with areas more than twice the standard deviation were considered contami nated by an interfering chemical and were eliminated from the PCB estimate of the mixture. At least 4 of the 8 reference peaks were required to be present before an estimate of the PCB mixture was reported as an recognizable PCB mixture. GC/HS Analysis the extract of the 30 gm tissue samples were first screened using a flame ionization detector (FID) and then by CC/KS using identical * GLC conditions. The column was a 6 ft. X 1/8 in. (O.D.) glass column packed with 80/100 mesh Gas Chron Q coated with 3 percent 0V-101, The temperature was programmed from 100C after a 5 min. hold to 225C at 4C/min. HONS 002605 The CC/.MS analysis was performed on a Varian Mat CIC-5 mass spectrometer interfaced with a Varian 6011 data system. Spectra were acquired repetitively every 7 seconds during the gas chromato graph elution and, alter mass 'conversion on the 620i computer, were transmitted to a Vaxian 62QL computer for data formating and analysis. t The screening of the GC/MS data was accomplished by selecting ions In the mass spectra of chemicals of interest and seaiching all of the spectra for the GC peaks where these Lons occur most intensely. The most rapid screening of this data Is the mass chromatogram which is simply a plot.of the intensity (heigh) of the characteristic ion, or mass, as a function of GC retention time which is stored In the computer as the spectrum number (i.e. one spectrum every seven seconds). This produces a new "gas chromatogram'* In which peaks are observed only if a chemical is present that has the selected charac teristic ions. HONS 002606