Document a1qGrXGkwRLQRJwDvyoqMNn79
EPA Inspection Report Page 1 of 9
Region 6 - Enforcement & Compliance Assurance Division
INSPECTION REPORT
Inspection Date(s): Media Program: Regulatory Program(s)
02/06/2024 Air NESHAP
Company Name: Facility Name: Facility Physical Location:
(city, state, zip code) Mailing address:
(city, state, zip code) County/Parish: Facility Phone Number Facility Contact:
Valero Energy Partners Port Arthur Products Station 5300 Old W. Port Arthur Rd. Port Arthur, TX, 77640 5300 Old W. Port Arthur Rd. Port Arthur, TX, 77640 Jefferson County 409-984-3576 Brad Guidry Brad.guidry@valero.com
Regional HSE Lead
FRS Number: Identification/Permit Number: Media Identifier Number: NAICS: SIC:
110063167442 RN102027174 / 56342 ICIS 3601631501 486910 4613
Personnel participating in inspection:
Benjamin Donaldson
Region 6 ECDAT
Kenneth McPherson
Region 6 ECDAT
Justin Chen
Region 6 ECDAT
Daniel Hoyt
OECA AED
Nathan Hicks
OECA AED
Richard Helmich
NEIC
Philip Myers
NEIC
Jody Lambright
Valero Energy Partners
Aaron Lyons
Valero Energy Partners
Dustin Harris
Valero Energy Partners
Brad Guidry
Valero Energy Partners
Paul Cox
Colonial Pipeline Company
Brian Willford
Colonial Pipeline Company
Ryan Tedford
Colonial Pipeline Company
Gary Revia
Colonial Pipeline Company
Curt Spell
Colonial Pipeline Company
Environmental Engineer Life Scientist Environmental Engineer Environmental Engineer Physical Scientist Chemist Mechanical Engineer Senior Area Manager Area Manager
Operations Manager Regional HSE lead Senior Operator Safety Specialist Environmental Specialist Maintenance Supervisor Operations Supervisor
EPA Lead Inspector Signature/Date
Digitally signed by Benjamin
Benjamin Donaldson Donaldson
Date: 2024.04.12 08:03:24 -05'00'
Benjamin Donaldson
Date
Supervisor Signature/Date
JAMES LEATHERS Date: 2024.04.12 11:32:46 -05'00' Digitally signed by JAMES LEATHERS
James Leathers
Date
6ENFORM-019-R8.2 (02/12/2020)
1
EPA Inspection Report Page 2 of 9
Section I - INTRODUCTION
Valero Energy Partners / Port Arthur Products Station Inspection Date 02/06/2024
PURPOSE OF THE INSPECTION
EPA inspectors Benjamin Donaldson (R6 ECDAT), Justin Chen (R6 ECDAT), Kenneth McPherson (R6 ECDAT), Daniel Hoyt (OECA AED), and Nathan Hicks (OECA AED) accompanied by Philip Myers and Richard Helmich (National Enforcement Investigations Center, "NEIC") arrived at the Valero Energy Partners ("Valero") Port Arthur Products Station at 8:32 AM on February 6, 2024, for an unannounced inspection. We met with Jody Lambright, Valero senior area manager, Aaron Lyons, Valero area manager, Dustin Harris, Valero operations manager, Brad Guidry, Valero regional HSE lead, Paul Cox, Colonial Pipeline Company ("Colonial") senior operator, Brian Willford, Colonial safety specialist, Ryan Tedford, Colonial environmental specialist, and Gary Revia, Colonial maintenance supervisor. Credentials were presented to Ryan Tedford for Colonial and Jody Lambright for Valero and informed them that this was an EPA inspection to evaluate potential sources of excess emissions using EPA's Geospatial Measurement of Air Pollution ("GMAP") vehicle and evaluate compliance with the facility's Federal Operating Air Permit and the Clean Air Act. The scope of the inspection is a partial compliance evaluation ("PCE"). This inspection occurred as part of a multi-scale monitoring project in the BeaumontPort Arthur area. Photographs and video taken during the inspection can be found in Appendix 1 and 2, respectively. The sign-in sheet for the opening conference is attached as Appendix 3.
FACILITY DESCRIPTION
The Port Arthur Products Station is a tank storage terminal operated by Valero that operates under New Source Review Permit Number 56342 issued June 16, 2015. Colonial is also co-located within the Port Arthur Products Station.
Section II - OBSERVATIONS
The NEIC GMAP was driven by Mr. Helmich, the instruments were operated by Mr. Myers, and observed in the vehicle by Mr. Donaldson. Facility representatives Ryan Tedford, Jody Lambright, Brian Wilford, and Dustin Harris escorted the GMAP. Conditions were sunny and windy with winds from the northnortheast. Inspectors Justin Chen, Kenneth McPherson, Daniel Hoyt, and Nathan Hicks followed the GMAP in secondary vehicles. Daniel Hoyt and Nathan Hicks operated a Data Acquisition in Real Time (DART) unit on their vehicle, equipped with a photoionization detector (PID) that measures volatile organic compounds ("VOC") in the air, and a wind monitor that monitors wind speed, wind direction and geolocation. The DART unit had a 10.6ev PID installed. The GMAP drove on all available facility roads measuring air pollutant concentrations downwind of each of the process areas, if possible. A full report from the GMAP will be issued by NEIC at a later date.
The GMAP detected elevated readings while downwind of Tank 2060. According to Mr. Lambright, Tank 2060 is a fixed roof tank, owned by Valero, and contains diesel fuel. Mr. McPherson operated an Optical
2
EPA Inspection Report Page 3 of 9
Valero Energy Partners / Port Arthur Products Station Inspection Date 02/06/2024
Gas Imaging Camera ("OGIC") and observed emissions from the level gauge of Tank 2060 (R0010088.jpg, FLIR0002.mp4, FLIR0003.mp4). [AOC1] The GMAP detected elevated readings while downwind of Tank 1372. According to Mr. Lambright, Tank 1372 is a fixed roof tank, owned by Valero, and contains diesel fuel. Mr. McPherson operated the OGIC and observed emissions from the dome of the fixed roof tank (FLIR0004.mp4, FLIR0006.mp4). [AOC 2] The site GMAP survey ended at 11:15 AM and we returned to the conference room. Section III - AREAS OF CONCERN Benjamin Donaldson conducted a closing conference at the Valero Energy Partners Port Arthur Products station at 11:15 AM on February 6, 2024, for the inspection. Mr. Meyers and Mr. Donaldson summarized the facility tour and presented their emissions observations, including the following Areas of Concern. The facility made no claims of confidential business information regarding the photographs or videos. The facility was informed that copies of the videos would be made available to the facility following the inspection. We departed the facility at 11:38 AM. 1) Emissions observed from the level gauge of Tank 2060. 2) Emissions observed from the dome of the fixed roof for Tank 1372. Section IV - FOLLOW UP The following information was received by EPA on March 1, 2024, after exiting the Facility on February 6, 2024: The TCEQ RN for the facility is RN102027174 as well as an attached copy of the New Source Review Permit. Section V - LIST OF APPENDICES
Appendix 1 - Photo Log - 1 photo taken 02/06/2024 Appendix 2 - Video Log - 4 FLIR videos taken 02/06/2024 Appendix 3 - Opening and closing conference sign-in sheets
3
EPA Inspection Report Page 4 of 9
Valero Energy Partners / Port Arthur Products Station Inspection Date 02/06/2024
Appendix 1 Photograph Log
EPA Inspection Report Page 5 of 9
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Photograph Log
Photo No. 1
Location: Valero Energy Partners Port Arthur Product Station
City: Port Arthur
County/Parish: Jefferson
State: TX
Photo File Name: R0010088.JPG Date of Photo: 02/06/2023 Time of Photo: 10:10 am Photographer: Kenneth McPherson Description: Tank 2060
EPA Inspection Report Page 6 of 9
Valero Energy Partners / Port Arthur Products Station Inspection Date 02/06/2024
Appendix 2 Video Log
EPA Inspection Report Page 7 of 9
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Video Log
Appendix 2
Location: Valero Energy Partners / Port Arthur Products Station
City: Port Arthur
Jefferson County
State: Texas
Video File Name: Date of Video: Time of Video: Videographer: Description:
FLIR0002.mp4 02/06/2024 10:00 am Ken McPherson Emissions observed from Tank 2060 level gauge
Video File Name: Date of Video: Time of Video: Videographer: Description:
FLIR0003.mp4 02/06/2024 10:05 am Ken McPherson Emissions observed from Tank 2060 level gauge
Video File Name: Date of Video: Time of Video: Videographer: Description:
FLIR0004.mp4 02/06/2024 10:30 am Ken McPherson Emissions observed from the fixed roof dome of Tank 1372
Video File Name: Date of Video: Time of Video: Videographer: Description:
FLIR0006.mp4 02/06/2024 10:30 am Ken McPherson Emissions observed from the fixed roof dome of Tank 1372
Page 1 of 1
EPA Inspection Report Page 8 of 9
Valero Energy Partners / Port Arthur Products Station Inspection Date 02/06/2024
Appendix 3 Opening and Closing Conference Sign-in Sheets
EPA Inspection Report Page 9 of 9
Valero Energy Partners / Port Arthur Products Station Inspection Date 02/06/2024