Document a1pv8Ze97akz567x07aG12n9b
FILE NAME DuPont DUP
DATE 1967 Nov 13
DOC DUP157
DOCUMENT DESCRIPTION Internal Report - Chambers Construction Asbestos Dust Exposure Control
UF
:
CHAMBERS CONSTRUCTION ASBESTOS DUST EXPOSURE CONTROL
Mechanical Aspects
< DEFENDANT'S
EXHIBIT
Kemper Kemper
6 31-84
November 13 1967
The personnel and environmental sampling done at this site reveals we have
reasonable control of the asbestos hazard at this tire The following
conclusions and recommendations if adopted should establish similar
satisfactory environments at any site
1 Maintain an air sampling program This is essential to the overall
safety endeavor anyway . Respirable dust particles from nearly any
source are hazardous and ahuisance
) Isolate machine operations in the shops from other shop facilities
3 All possible dust from cutting and shaping functions must be
collected by an effective exhaust and collector system preferably
.
wet collector System should not vent off to the atmosphere collected
(
dust particles
4 Keep shop equipment ledges etc. vacuumed clean Eand cutting should be done so the scrap and dust fall into a container wherever possible
5 Open cartons with care Dust is shaken loose from shipping abuse and is a source of hazardous asbestos dust quantities The carton can be vacuumed prior to opening if deemed accessary by cutting an opening
in the carton and introducing a vacuum hose
6 Asbestos cepents must be handled with great care A system to evold manhandling and mixing by hand is beneficial This may be accomplished by a dispensing system or procurement of the cement in small plastic bags where water may be introduced and the cement kneaded with no
dust exposure
7 Smoking should be prohibited in shop and when operating tools and equipment performing dust producing work
8 Severe conditions might dictate the need for respiratory protective
devices however every attempt should be made to avoid this slace
it never adequately considers the people in adjacent areas Further-
more respiratory protective devices when required are admission of
a problem
Since the law accepts even a casual exposure ac hazardous ,
the protective devices should be avoided
)
Exhaust and ventilation should maintain atmosphere total dust count below the Threshold Limit Values as established by the Americas
Conference of Governmental Industrial Hygienists
ket
001308
,
ti |
1131189| ee
oe |
1
} fe
4
ma .
**
-
ne
a
j
.an? (/!
)
4
|
ES
ees
2
ie
.
CHAMBERS
4 a
CONSTRUCTION
4
*
eo
-
6
6
11038
h
ine h
- /
i
11038 11038
m
_
we
oe meee
ASBESTOS DUST EXPOSURE CONTROL
November 20 1967
ae
The preliminary personnel monitoring survey carried out during August 1967 on Chambers Works confirmed earlier environmental surveys Ref 1 and ) on Chambers Works and in the Spruance Shops which demonstrated that the total particle count not corrected for asbestos
content does not exceed one per cent of the current Threshold Limit
Value TLV established for asbestos dust by the American Conference of
a
Governmental Industrial Hygienists ACGIH The personnel monitor
samples were collected in filters over four to five hour periods Since
impingers were not employed the respirable fraction cannot be estimated
but can be ignored as the total particle count is many orders of magnitude
less than the established TLV
However these results should not serve as a basis for complacency but rather should provide a base for establishing a permanent monitoring program Federal and State 1.e. New Jersey legislation enacted over the past ten years has placed the burden of proof for continuous
conformance with established TLV's on the employer In view of this major shift in responsibility for ambient air quality control and the trends in compensation claim decisions an effective Industrial Hygiene program becomes imperative This responsibility becomes acute when employment medical examinations are not available for the employees
Standards for equipment performance and ventilation specifications should e+rie
be established as soon as possible to incorporate those current practices
retag
wtea
and design features which by these surveys have demonstrated effective dust
bah
emission control Work procedures and protective equipment requirements also should be formalized to provide not only an internal operating standard for other departments of the Du Pont Company but also for the guidance of outside contractors employed by Du Pont under contract
A permanent quality control program is recommended to provide not only
quantitative data for internal evaluation of dust control efficiency but
also to document air quality analysis needed to demonstrate conformance conformance
with established TLV's and provide effective defense in litigation cases Under current conditions a continuous daily monitoring program does not appear to be necessary or desirable However a formal program for sampling and analyzing the work atmosphere with a frequency which will include all phases of asbestos usage should be established and consistently administered for as long as a TLV for asbestos remains in force In general once a month should suffice for general work areas If circumstances which involve unusual dust generation should arise special monitoring will be required to evaluate the potential exposure severity
Insofar as possible personnel monitory sampling equipment carried by
a selected employee continuously during his work assignment should be
employed Only in this manner can a truly representative sample of the atmosphere inhaled by the employee during his eight work day be obtained Such equipment is available and has been applied successfully
on Chambers Works
A further requirement for an effective monitoring program will include the employment of fully qualified preferably certified Industrial Hygienists to directly conduct collection of the samples and to carry
out the dust counting The documentation of field notes and analytical
results and the preparation of reports also should be the responsibility of the Industrial Hygienist
2
<e
Equipment Specifications
A. Station Sampling - Portable Ref Air Survey Memorandum of October 21 1966
1. The Freon powered Unico Constant Rate Jet Air
Sampler or the Unico Automatic Jet Air Sampler fitted with an improved standard midget impinger Unico 2000 in
series with an 0.8 micron pore size Millipore filter
Cat No. MANG037AO is acceptable for use in all explosion hazard areas and was used in the collection of samples reported in part one of the Chambers Works and Spruance Works surveys Ref 1 and 2 The sample must be collected at a uniform
standard 0.1 cubic feet per minute rate Cfm and at least
one cubic foot of air should be sampled These units will operate unattended for three to four hours A dry sampler the Unico Model 2.8 Respirable Dust Sampler could be used to separate the respirable from the nonrespirable fraction but is
not recognizebdy the Asbestos Textile Institute
As an alternate the rechargeable battery powered Unico Model 440 Mighty Mite Air Sampler may be used This Midget sampler
was used successfully for personnel monitoring on Chambers
Works Part 3 For explosion hazard areas the slightly larger
Telmatic Model 150 sampling unit equipped with an intrinsically
safe Factory Mutual approval battery circuit is recommended Either of these units perform satisfactorily with either the
"
Millinore filter alone or in series with the standard Midget impinger or the newer Microimpinger personnel monitoring Four to five hours of sampling at 0.1 Cfm will be delivered per
single battery charge Longer periods will be obtained at lower
sampling rates with either the filter alone 0.05 Cfm or the
.
microimbinger 0.02 Cfm Larger capacity batteries are available
tana
| Tee
Mb
.
\
pale
11
i.
~
be.
is,
t
Ke
ae
"
}
-4-
Equipment Specifications Specifications
B. Personnel Monitoring
Continued
1. The Unico Model 440 Mighty Air Sampler for explosion
hazard areas or the Model 150 Telmatic for explosion hazard
limitations is the instrument of choice see A
future a third model 440 equipped with total
In the volume
near
read-
out will be available For total dust count only the Millipore
filter is required for sample collection Where respirable as
well as total count is required the microimpinger is used in
series with the filter Whichever system is elected the
collection device should be located as closely as possible to the
man's breathing zone without interfering with his work assignments
2 As an alternate solution to the sampling problem in explosion
hazard locations the Model VIE Uni Air Sampler fitted
with a 6 ml orifice may be substituted for the battery onerated pump However without additional calibration for use with the
microimpinger dust collection would be limited to filter operation A one pound charge of Freon will activate the sampler for
four to five hours and aspirate a five to six cubic foot sample
Ad Ad Ad Ad AdAd Ad A. L. Linch Medical Division
REFERENCES
1 Thatcher L. V. - Interim Report - Asbestos Survey - January 27 1967 addressed to K. E. Keuber Division Safety Superintendent
Construction Division - Louviers Building
2. Thatcher L. V. Asbestos Survey - Interim Report Results of Spruance Construction Survey - April 11 1967 addressed to K. E. Keuper address as in 1
3
WG
VW
TQ wi
,
P
a
P
|
|
|om
,
T
E
16
|
r
)