Document a1OjOnrrb9J8ZaNn8mnJxzrzY
Boilers, Steel
Fitzgibbons Boiler Co., Inc. Established 1886
General Offices: .570 Seventh Avenue, New York, N.Y.
Works: OSWEGO, N.Y. Branches and Representatives in Principal Cities
The Sm ofthe BEST in PRODUCTS: Fitzgibbons Steel Heating and Power Boilers, as
STEEL boiler HEAT
on tj,ig an<} the following three pages, meet the heating re
quirements of all buildings from the small home to the gigantic
modern skyscraper. The line includes types for burning anthracite, bituminous (soft)
coals or coke, or for oil, gas or stoker firing, in steam, vapor, vacuum or hot water sys
tems, as specified. In other words, there is a Fitzgibbons Steel Boiler for every fuel and
every heating system, in installations of every size from the smallest to the largest.
Distinctive Characteristics: Highest quality construction down to the last detail; quick
"pick-up" of the heating load; high efficiency resulting in large fuel savings, even with below
average attendance; easy installation; compact space requirements; durability that outlasts the
enclosing buildings; complete heating satisfaction from every point of view.
Descriptive Literature: Illustrated Catalogs and Bulletins, giving full details of design and
construction will be mailed on request. Ratings: The ratings given in the following tables can be depended upon. They are the
total radiation loads (taken at the boiler outlet),
which the respective boilers will heat, with 2 lbs. pres
sure at the boiler for Steam and 180 F for Hot Water.
Ratings are expressed in sq. ft. of equivalent cast-iron
radiation, emitting 240 B.t.u. per sq. ft. per hour for
Steam, and 150 B.t.u. per sq. ft. per hour for Hot Water.
FITZGIBBONS
Copper-Steel Residence Heating Boilers
Electric-Welded.
for Small and Medium Size Heating Plants. All Fuels and All Heating Systems.
TABLE I -- for Anthracite, Bituminous Coals or Coke.
TABLE 1 - B -- for burning Soft Coal Smokelessly.
TABLE 1-OH--for Oil, Gas, or Domestic Stoker firing. Bulletins giving ratings of Table 1 -OH boilers sent on request.
Racines and Dimensions TABLES 1 and 1-B Combined--Sizes: 400 to 3200 sq. ft. Steam Radiation Built for 15 lbs. w.s.p.--A.S.M.E. Code
J-8 H-8 J-12 H-16 H-20 H-24 H-28 H-32 H-36 H-44 H-50 H-58 H-64
Number of Smokeless Boiler
None B-8 B-I2 B-16 B-20 B-24 B-28 B-32 B-36 B-44 B-50 B-58 B-64
400 400 600 800 1000 1200 1400 1600 1600 2200 2500 2900 3200 Hot Water Rating............. .. . sq. ft. 700 700 1000 1300 1600 1900 2200 2600 2900 3500 4000 4600 5100
Heating Surface ............... .. .sq. ft. 33 "Comp. Grate Area............ .. .sq. ft. 2.5
35 51 3.36 3.36
67 78 95 108 123 150 192 233 249_ 295 4.35 4.35 5.84 5.84 7.10 7.10 8.50 8.50 10.00 10.00
24 27 27 30 . 30 34 34 38 38 41
3-3 3-9 4-5 4-9 5-3 5-8 6-2 6-9 7-9 7-7
16 18 18 21 21 23 23 27 27 31
4-2 4-3 4-3 4-8 4-8 5-0 5-0 5-5 5-5 5-9
3-5 3-7 3-7 4-0 4-0 4-4 4-4 4-7 4-7 4-11
19 22 22 25 25 29 29 32 32 35
26'/2 30 30 33/, 33/, 37/, 3!'/l 40Vi 40V, 42V.
18 18 22 24 30 V 32 31 43 35
5}xl2| 8
5jxl2j 8
51x12* 8
61x151 10
61x154 10
1\* If* 12
71I7| 12
84x204 14
81x20* 14
94x22 16
....feet 40 40 45 40 45 45 45 50 50 50
29 33 37 52 58 60 66 72 80 86
Approx. Shipping Weight... ........lbs. 920 1150 1225 1525 1625 2000 2100 2400 2460 3000
41 *-7 31 5-9 4-11 35.
42V. 47
9Jx22 16 60 94
3200
44 8-4 33 6-1
5-2 38
45V, 40
10x25 18 60 102
3550
44
9-4
33 6-1 5-2
38 453/.
52 10x25
18
60 110
3800
*It has been established that the Circular Grate in the Fitzgibbons Cylindrical Furnace is more effective than a rectangular grate the size of the circumscribed square. Hence, for comparative purposes, the Comparative Grate Area shown in the Tables is the area of the square circumscribed upon a circle the size of the Fitzgibbons Grate.
592
Fitzgibbons Boiler Co., Inc.
Boilers, Steel
UP-Drafl Type
FITZGIBBONS Z-U Steel Firebox Boilers
for All Fuels and All Heating Systems
Smokeless; Up-Draft; Oil, Gas, Stoker Types.
Sizes: 2300 to 38000 sq. ft. Steam Ratings--Built for 15 lbs. w.s.p.--A.S.M.E. Code.
Boiler
No.
Up. Draft
Type
Boiler Rating No. Steam. Smoke Sq. Ft less D&V
Type Types
Boiler
No. Oil
Gas, Stoker
Type
Rating Steam.
Type
Heat ing Grate Sur Area. face. Sq.Ft.
Sq. Ft.
Diam. Boiler, Inches
Length Boiler,
Ft-In.
Height Over
all Inches
Water
Line; Inches
Smoke
&
Inches by
Inches
Diam. Stack. Inches D&V Types
Height Stack,
Feet
D&V Types
.Size
Out let, Inches
Size Re
turn,; Inches
Apprx. Cover
ing Sur face. Sq.Ft.
Apprx. Ship ping
If-
V&D Types
D23 V23 2324 M28 2822 166 9,1 36 5-8 68
60 8x23 20 50
D29 *V29 2902 *M35 3536 208 10.4 36 6-5 68
60 8x23 20 50
*D35 *V35 3500 *M42 4250 250 117 36 7-5 68
60 8x23 20 55
D40 *V40 4004 M48 4862 286 12.9 36 8-5 68
60 8x23 22 55
*D45 *V45 4508 M54 5474 322 14.0 42 7-9 Tl'h 63 10x24 22 55
*D50 V50 5012 *M60 6086 358 15 5 42 8-9 72# 63 10x24 22 60
D55 V55 5502 M66 6681 393 15.5 42 9-6
63 10x24 24 60
D59 *V59 D69 V69
5960 M72 7242 426 16.3 48 6944 M84 8432 496 18 1 48
7-9 9-1
sBOo'#/z
69 69
10x32 24 10x32 24
60 65
D80 V80 8022 M97 9741 573 19.8 48 10-1 80# 69 10x32 24 65
D90 *V90 9002 M109 10931 643 22.7 54 9-4 86V, 74 11x34 26 60
DIOO VIOO 10010 MI21 12155 715 22.7 54 10-1 86/2 74 ttx34 26. 65
DUO VII0 11088 M134 13464 792 24.7 54 11-1
74 11x34 28 65
DI23 VI23 12366 M149 14943 879 25 5 60 10-2 h'/z . 82 (4x40 30 65
DI36 VI36 13608 M165 16524 972 27 8 DI51 VI5I 15106 M183 18343 1079 30.0
60 60
11-2 12-2
95/z 82- 14x40 30 95# 82 14x40 30
70 75
DUO . V170 17010 M206 20655 1215 30.8 66 11-9 103# 89 15x40 32 80
DI89 V189 18900 M229 22950 1350 33.3 D2I0 V210 21000 M255 25500 1500 36 7
66 72
13-0 103/2 89 12-2 III# 96
15x40 32 16x46 32
85 85
D230 V230 23002 M279 27931 1643 36 7 D250 V250 25004 M303 30362 1786 40.0
72 78
13-2 12-4
HI# 96 117# 100
16x46 32 16x52 34
90 90
D270 V270 27006 M327 32793 1929 40.0 D302 V302 30212 M366 36686 2158 43 3
78 84
13-2 12-6
117Vi 100 123# 105
16x52 34 18x58 36
95 95
D347 V347 34720 M421 42160 2480 46.6 84 13-10 123# 105 18x58 40 100
D378 V378 37828 M459 45934 2702 46.6 84 15-0 123/2 105- 16x58 40 110
5 3 60 3600 6 4 70 3900 6 4 75 4200 6 4 80 4500
6 4 105 5400 6 - 4 113 6100 6 4 119 6400 6 4 126 6800 6 4 142 8000 6 4 155 8800
8 6 166 9800
8 6 177 10600
8 6 192 11900 8 6 198 12700 8- 6 212 13400 8 6 228 14600
8 6 250 (6800 8 6 272 18500
8 6 280 20000 8 j> 300 21000 10 6 318 22000
10 6 335 23000 10 6 336 25000 10 6 368 27000 10 6 398 29000
*No rear stand required or furnished on these sizes of boiler.
593