Document ZqvQ87xw2RekrVRe49Ep5Zp
PYORAUL
FIRE-RESISTANT HYDRAULIC FLUID
SELECTOR
TOWOLDMONOQ27692
PYDRAUL KLiigir
TOWOLDMONOQ27693
THE PYDBAUL SELECTOR
... is designed to put literally at your finger tips all the facts about Pydraul fire-resistant hydraulic fluids--to guide you quickly to the Pydraul fluid that will serve your operation best. Protection from fire for hydraulic operations began with Pydraul. That was in 1951. Pydraul fluids have since served industry with over one billion machine hours of firefree operation. Never during these billion hours of machine operations has a Pydraul fluid contributed to a fire--not even when sprayed from the broken ends of high pres sure hydraulic lines onto white-hot surfaces. New ways are continuously being explored to improve the excellent performance records of Pydraul fluids. The first Pydraul fluid, general-purpose Pydraul F-9, has grown to a family of six, specially tailored, fire-resistant hydraulic fluids and lubricants. Each answers a major but specific hydraulic fluid need for industrial use. In addition to guarding against fire, each Pydraul fluid lubricates as well as premium grade oil. Pydraul fluids have answered the need of virtually every indus trial hydraulic operation, indoors and out-- from the sub-zero, outdoor hydraulic lift operations for refineries and blast furnaces to the low-viscosity fluid demands of high speed, precision machine tools.
0237<,eq
TOWOLDMONOQ27694
PYDRAUL PERFORMANCE
The six fire-resistant, premium-lubricating Pydraul fluids offer a wide range of viscosities from which you can select the proper level specified by your hydraulic equipment man ufacturer. Whichever Pydraul fluid you select, each provides the same protection against fire, premium lubricity, ease of main tenance, and freedom from corrosive action and foam. Pydraul hydraulic fluids also offer several additional benefits-- REDUCED FIRE INSURANCE RATES Because Pydraul eliminates fire hazards from hydraulic equipment operations, Pydraul re duces the threat of fire to surrounding struc ture and equipment. Insurance premiums for plants using Pydraul, therefore, are often lower than premiums for operations using petroleum oil. LONGER pump ufe Machines that operate on water-based fluids frequently require pump repair or replace ment as often as every two or three months. Machines that use Pydraul hydraulic fluids can operate on the same pump for several years. Pydraul hydraulic fluids give the same long pump life as the finest grade petroleum oil.
0237490
TOWOLDMONOQ27695
NO CORROSION PROBLEMS Any metal hydraulic system component in contact with Pydraul will not rust. And Pydraul hydraulic fluids do not lose anti rust properties with use. MAXIMUM EQUIPMENT RESPONSE Pydraul never produces excessive froth or foam during normal operations to interfere with hydraulic equipment response. Because Pydraul hydraulic fluids lubricate as well as premium petroleum oils, Pydraul permits equipment to operate at optimum response capability. INSPECTION AND REPLACEMENT DOWN-TIME ARE VIRTUALLY ELIMINATED Pydraul hydraulic fluids are designed to be permanent. Pydraul fluids do not wear out. Except for normal "make-up" requirements, you never have to add new Pydraul to hydraulic systems. Pydraul eliminates "drain and change" periods; it does not have to be inspected in your system from month to month--or even replaced from year to year.
'3H91
TOWOLDMONOQ27696
TOWOLDMONOQ27697
PYDRAUL
60
Low viscosity Pydraut 60 flows freely at --20 F. It retains its properties and thermal stability at tem peratures up to 200 F. In hydraulic operations that require precision flow instantly, Pydraul 60 sup plies smooth operation from machine start to stop; it offers flow-on-demand operation without hydrau lic lag. Pydraul 60 offers excellent, fire-resistant, hydraulic operation with vane, gear and piston pumps in high-speed ma chine tools.
FIRE-RESISTANCE TESTS
Pydraul fluids protect hydraulic equipment and personnel with permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their more than one billion machine hours of use, Pydraul fluids have been accidentally sprayed over molten metal, through electrical arcs, into flames and sparks--without caus ing fire. Pydraul fluids have never caused or contrib uted to an hydraulic fire in any type of equipment. They pass all of the im portant ignition tests for fire-resistance, as shown by these test results:
Physical Properties
Appearance
Spec. Gravity 25/25C
Neutralization No. (acidity)(mg KOH/gm) max
Moisture(max)
Viaeeelty At measured: 100 F.
210 F. "Absolute Saybolts" 100 F. (SSU X Density) 210 F.
Pour Point
Compressibility X10-* sq. in./lb.
Bulk Temperature Max.
Boiling Point F at 760mm Hg.
Coefficient of Thermal Expansion per F.
Specific Heat <BTU/lb./ F.)(C. 77 F.)
Thermal Conductivity BTU/hr./ft./0 F.
Vapor Pressure Hg (d, 200 F.
Bulk Modulus /doom Temp t 1 1000-6000 ]
Solubility in Water
Test
High Pressure Spray Teat AMB-SIHC and MIL-F71M. Test fluid sprayed at 100 psi through orifice, passing through flame of oxyacelylene torch, 6000 F.
Lea Pressure Spray Teat (AMS-S1MB). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase m flame intensity.
Hot ManHeld Test (MIL-F-7100). Test fluid dripped on tube at 1300 F.
[
Melten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy
at 1200 F., to test for spontaneous ignition.
[
TOWOLDMONOQ27698
TOWOLDMONOQ27699
Physical Prepsrtlei Appearance
Spec Gravity 25'72bC Neutralization No. (acidity)(mg KOH/gm) max. Moisture (max.)
As measured: I00: F 210 F
"Absolute Saybolts" 100 F. (SSU X Density) ?10 F. Pour Point Compressibility X10* sq. in./lb. Bulk Temperature Max. Boiling Point F at 760mm Hg. Coefficient of Thermal Expansion per F. Specific Heat (BTU/lb./ F.)((n. 77 F.) Thermal Conductivity BTU/hr./ft./ F. Vapor Pressure Hg (a 200 F. BulkModulus /Room Temp.l
I 1000-6000 \ psi I Solubility in Water Teet
High Pressure Spray Test AMS-S160B and MIL-FTIM. Test fluid sprayed al 100 psi through onlice. passing through flame of oxyacetylene torch, 6000 F. Lew Pressure Spray Test (AMS-HWB). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity. Het Manifold Test (MIL-F-T1M). Test fluid dripped on tube al 1300" F.
Melten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200 F , to lest lor spontaneous ignition.
TOWOLDMON00277QO
PYDRAU
A-2(K
Pydraul A-200 is one of the most widely used, generalpurpose, fire-resistant hy draulic fluids in industry. Introduced in 1959, it was the first fire-resistant, straight synthetic hydrau lic fluid to break the "price/ performance barrier." Where protection from fire is the maximum consider ation, Pydraul A-200 offers the lowest cost per gallon of straight synthetic, fireresistant hydraulic fluids.
i
TOWOLDMONOQ27701
'I
I
I
O' s
(oNl
?v
Physical Prafarllai
Appearance
Spec. Gravity 25/25C Neutralization No. (acidity) (mg KOH/gm) max.
Moislure(max.) VUawIty As measured: 100 F.
210 F "Absolute Saybolts'' 100 F. (SSU X Density) 210 F
Pour Point
Compressibility X104 sq. in./lb.
Bulk Temperature Max
Belting Point F at 760mm Hg.
Coefficient of Thermal Expansion per0 F.
Specific Heat (BTU/lb./ F.Kfe 770 F.)
Thermal Conductivity BTll/hr./ft./ F.
Vapor Pressure Hg <?, 200 F.
Bulk Modulus/Room Temp,x ^ 1000-6000 j
Solubility in Water
Test
High Pressure Bpray Teel AMMftM and MIL-FTIM. Test fluid sprayed at 100 psi through entice, passing through flame of oxyacetylene torch, 6000 F.
Lew Prteiuf# Bpray Tail (AMI-I1MB). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree o( increase in flame intensity.
Hit MeptfeW Test (MIL-P-TIM). Test fluid dripped on tube at 1300 F.
Molten Metal lynitlen Teat. Test fluid exposed to the surtace of aluminum alloy at 1200 F., to test for spontaneous ignition.
TOWOLDMON0027702
TOWOLDMONOQ27703
Physical Properties Appearance
Spec. Gravily 25/25C Neutralization No. (acidlty)(mg KOH/gm) max. Moiiture(max.) Vtweelty At measured: 100 F.
210 F. "Absolute Saybolts" 100 F. (SSU X Density) 210 F. Pour Point Compressibility XlO* sq.in./lb. Bulk Temperature Max. Boiling Point F at 260mm Hg. Coefficient of Thermal Expansion per0 F. Specific Heat (BTU/lb./ F.)(& 77 F.) Thermal Conductivity BTU/hr./ft./ F. Vapor Pressure Hg <8, 200 F. Bulk Modulus / Room Temp A
| 1000-6000 j
Solubility in Water Teat
High Pressure Spray Test AMI-S1MB and MIL-PTIM. Test fluid sprayed at 100 psi through orifice, passing through flame of oxyacetylene torch, 6000 F. Lew Pressure tpray Tjm (AMt-lIMB). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase inflame intensity. Net Manifold Test (MIL'MtM). Test fluid dripped on tube at 1300 F.
Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200 F., to test lor spontaneous ignition.
I
TOWOLDMONOQ27704
625
It
f.:/<
I
fl7 't f.
f7
PYDRAUL
625
High viscosity Pydraul 625 is tailored for ultra-heavyduty hydraulic operations, such as for large industrial presses and pumps. Py draul 625 is also used as a fire-and -explosion- resist ant air compressor lubri cant. Pydraul 625 can be used in any equipment re quiring an 800 to 1000 SUS oil.
0237500
TOWOLDMON0027705
Physical Prapertlai Appearance
Spec. Gravity 2b/2bC Neutralization No. (acidity)<mg KOH/gm) max. Moisture<max.) Viscosity As measured: 100 F.
210 F. "Absolute Saybolts" 100 F. (SSU X Density) 210 F. Pour Point Compressibility X104 sq. in./lb. Bulk Temperature Max Boiling Point F at 760mm Hg. Coefficient of Thermal Expansion per0 F. Specific Heat (BTU/lb./ F.)s 77 F.) Thermal Conductivity BTU/hr./ft./0 F. Vapor Pressure Hg (3, 200 F. Bulk Modulus / Room TempA
I 1000-6000 ]
Solubility in Water Test
High Pressure tpray Teel AMS-I1MB and MIL-T7100. Test fluid sprayed at 100 psi through orifice, passing through flame of oxyacetylene torch. 6000 F. Lew Pressure Spray Teat (AMS-SttOB). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity. Hat Manifold Teat (MIL-F-7100). Test fluid dripped on tube at 1300 F.
02 3 7 *>01
Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200 F., to test for spontaneous ignition.
TOWOLDMONOQ27706
TOWOLDMONOQ27707
Bfl Hi
w
Physical Properties
Appearance
Clear Blue Liquid
Cloudy Blue Liquid
Cloudy Blue Liquid
Cloudy Blue Liquid
Cloudy Blue Liquid
Cloudy Blue Liquid
Spec. Gravity 25/25C
1.340-1.360 1.340-1.370 1.270 1.300 1.415-1.430 1.119-1 135 1.0081 091
Neutralization No. (acidity)(mg KOH/gm) max.
Moisture(max.)
0.15 0.15%
0.30 0.15%
0.30 0.20%
0.80-1.10 0.05%
0.17 0.15%
0.25 0.10%
Vlseaalty As measured: 100 F.
210 F. "Absolute Saybolts" 100 F. (SSU X Density) 210 F.
408.8 SSU 42.1 SSU ' 550 SSU 50 SSU
625.7 SSU 45.9 SSU 645 SSU 59 SSU
225 SSU 43.3 SSU 327 SSU
52 SSU
144 SSU 35.7 SSU 204 SSU
48 SSU
145 9 SSU 52 5 SSU 163 SSU
56 SSU
60 SSU 35 SSU 60.5 SSU
35 SSU
Pour Point
+20 F. +20 F. -5 F.
+15 F. -55 F. -70 F.
Compressibility X10-* sq.in./lb.
Bulk Temperature Max.
2.66 300 F.
2.66 300 F.
2.58 300 F.
2.28 300 F.
3.13 200 F
3.05 200 f
Boiling Point F at 760mm Hg.
668 F.
724 F.
644 F.
620 F.
617 F.
707 F.
Coefficient ot Thermal Expansion per0 F.
0.00040
0.00040 0.00041
0.00040
0.00042
0.00044
Specific Heat (BTU/lb./ F.)( 77 F.) 0.32 028 0.32 0.28 0.40 0.4?
Thermal Conductivity BTU/hr./ft./0 F.
0.066
0.065
0.067
0.068
0.072
0.047
Vapor Pressure Hg 200 F.
0.02mm
0.09mm 0.1mm
0.2mm
0.1mm
0.01mm
Bulk Modulus /Room Temp.v ^ 1000-6000 j
375,000
375,000 387,000
438,000
319,000
328,000
Solubility in Water
Teat
High Pressure Spray Teat AMS-I16M and MIL-F7100. Test fluid sprayed at 100 psi through orifice, passing through flame of oxyscetylene torch, 6000 F.
Lew Pressure Spray Teat (AMS4160S). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity.
Met Manifold Teat (MIL-F-7100). Test fluid dripped on tube at 1300 F.
Molten Metal Ignition Teat. Test fluid exposed to the surface of aluminum alloy at 1200 F, to test tor spontaneous ignition.
Negligible Negligible
PYORAUL PYORAUL AC 126
Does not flash or Ignite up
to 3Vi feet from orifice.
Does not flash or ignite up
to 315 feet from orifice.
Very slight increase in flame intensity.
Very slight
increase in flame intensity.
Negligible
PYORAUL F-l
Does not flash or ignite up to 3V5 feet from orifice
No increase in flame intensity.
Negligible Negligible Negligible
PYORAUL PYORAUL PYORAUL
A-WO
160
60
Does not flash or ignite up
to 3H feet from orifice.
Self-ex tinguish ing
Sell-ex-
tinguishmg
Slight increase in flame intensity.
Slight increase in flame intensity.
Slight increase in flame intensity.
Does not flash or bum.
Does not ignite.
Does not flash or
bum.
Does not flash or bum.
0237 503
Does not ignite.
Does not ignite: flashes by spark.
Does not flash or burn.
Ooes not ignite.
Inter mittent flashing and burning. Little burning in pan below.
Dots not ignite.
Inter mittent flashing and burning. Does not burn aflei leav ing tube.
Does not ignite
TOWOLDMONOQ27708
PYDRAUL VISCOSITIES
Laboratory viscosity measurements of SSU (Saybolt Seconds Universal) are affected by fluid density. Because all petroleum oils used for hydraulic operations have similar densi ties, their measured viscosities can be com pared; however, the densities of synthetic fluids differ from one another and from petroleum oils. To compare viscosities, meas ured viscosities of synthetic fluids must be q corrected for density, in r*. On the chart below, each curve for a Pydraul ^ fluid shows the viscosity-temperature relaO tionship modified for the difference in density of the indicated Pydraul fluid. By comparing these curves with viscosity curves of light, medium, and heavy grades of petroleum oils, it can be seen that Pydraul fluids virtually duplicate viscosities of petroleum oils at normal operating temperatures.
E
TOWOLDMONOQ27709
CONVERTING TO PYDRAUL IS EASY
How to convert existing equipment. No matter what type of hydraulic fluid you now use in your equipment, you can easily convert to Pydraul. Virtually every type of hydraulic machinery requiring a fire-resistant hydraulic fluid has been converted to Pydraul. Equipment manufacturers are experienced in converting machinery to Pydraul and should be consulted for their specific recommendations. Some manufacturers will tell you exactly what seals to change. Most can supply the correct seals.
Machines operating on a straight synthetic, fireresistant fluid can be converted to Pydraul without interrupting your production. When converting to Pydraul A-200, Pydraul 625, or Pydraul AC, simply add Pydraul as make-up. To convert to other Pydraul fluids, drain the old fluid and refill with the Pydraul fluid. No flush is necessary.
Machines operating on oil or water-based hy draulic fluids require the few simple steps out lined below. These steps are necessary to clean the system of the old fluid and to change to dynamic seals compatible with Pydraul.
Check for leaks. Check the entire system before the equipment is shut down for conversion. Mark these leaks for later correction.
Drain fluid from the system. Drain the reservoir, lines, and cylinders as completely as possible to remove all of the old fluid. This can sometimes be done by opening unions at low spots in the system and blowing with clean air.
0230`>
VISCOSITIES CONVERTING
[
TOWOLDMONOQ27710
Clean reservoir and filters. Remove interior paint from the reservoir (if painted) by scraping or with a commercial paint remover. Wipe clean with lint-free rags. Clean or change the cartridge in the filter. Check pumps for wear. Replace any part of the pump assembly that shows serious wear. Install seals and packings compatible with Pydraul. Dynamic seals should be changed. Reinforcedtype hoses are normally satisfactory with Pydraul and need not be replaced if they are in good condition. In operations where severe hose flexing and bending take place, butyl-lined hoses are recommended. Accumulator dia phragms should be made of butyl, Viton, or other materials resistant to Pydraul. Reconnect lines. When reconnecting lines, tighten carefully -- particularly those joints that leaked previously. Then fill with Pydraul to the proper level. Start and stop pump. With the hydraulic controls in neutral, start and stop the pump several times, but do not allow the system to reach working pressure. This will help assure that fluid reaches the pump and lubricates it. The pump can then be left on, and the system can be brought to working pressure. Run through the cycle. Run through the cycle several times to use all parts ofthe hydraulic system. Bleed any trapped air through the petcocks or valves. Check the fluid level and add Pydraul if necessary. How to equip new machinery with Pydraul When ordering new hydraulic equipment, sim ply specify, "For use with Pydraul hydraulic fluid."
0237506
II
TOWOLDMONOQ27711
HANDLING AND STORAGE
As with all specialized industrial fluids, certain precautions are advisable when handling Pydraul fluids. No problems will arise when Pydraul fluids are used as recommended. Avoid repeated or continuous skin contact. Repeated or prolonged contact can lead to drying and skin "chapping." Where prolonged skin contact cannot be avoided, gloves should be worn. At room temperatures, there is no vapor inhala tion hazard from Pydraul; however, inhalation of vapors at high temperatures should be pre vented. In extensive animal experimentation, exposures to vapors for one hour showed local respiratory irritation, although no systemic effects were produced. Although eye irritation studies using Pydraul at full strength indicate Pydraul is a mild irri tant, there is no evidence to show Pydraul causes permanent damage to eye tissues. If Pydraul fluid is splashed or sprayed into the eyes, eyes should be thoroughly flushed with water and the workman referred to a physician. To relieve irritation, physicians have used 1% pontoeaine solution, as well as the ophthalmic cortisone acetate solution. Pydraul hydraulic fluids can be stored at sub zero temperatures without fluid damage. Be fore using, simply allow the fluid to warm to room temperature. Drums stored outside should be sealed tightly and placed in a horizontal position to keep out moisture.
0?37W7
HANIj.
TOWOLDMONOQ27712
TOWOLDMONOQ27713