Document ZqZ5EzekvOaGOdBLjz7qj8p7
DATE: SUBJECT: FROM: THRU: TO:
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS
77 WEST JACKSON BOULEVARD CIDCAGO, ILLINOIS 60604
JUN O5 2019
CLEAN AIR ACT INSPECTION REPORT Ascent Resources - Grywalski Well Pad, Dillonvale, Ohio
Natalie Topinka, Environmental Scientist AECAB (IL/IN)
Nathan Frank, Section Chief AECAB (IL/IN)
FHe
BASIC INFORMATION
Facility Name: Ascent Resources - Grywalski Well Pad
Facility Location: 40.198638, -80.829331, Dillonvale, Ohio
Date of Inspection: April 17, 2019
EPA Inspectors: 1. Natalie Topinka, Environmental Scientist 2. Victoria Nelson, Environmental Engineer 3. Constantinos Loukeris, Environmental Engineer
Other Attendees 1. Jon Hickman, EH&S Supervisor - Environmental, Ascent 2. Rob Messier, contractor to Ascent 3. Randy Moore, Ascent
Contact Email Address: jon.hickman@ascentresources.com
Purpose of Inspection: to assess compliance with requirements of NSPS Subpart 0000 and facility PTIO
Facility Type: oil and natural gas well pad
Regulations Central to Inspection: New Source Performance Standards (NSPS) Subpart 0000
Arrival Time: 3:10 pm Departure Time: 4:25 pm
Inspection Type: D Unannounced Inspection lg] Announced Inspection
OPENING CONFERENCE
lg] Credentials Presented lg] CBI warning to facility provided
The following information was obtained verbally from Ascent representatives unless otherwise noted.
Process Description: At the well pad, an oil/gas/water emulsion is extracted from the formation through wells on-site. The emulsion from each well goes to a separator, from which the gas is sent to the sales line and the liquids are piped to separate 400-barrel, atmospheric pressure, fixed-roof tanks on-site. The vapors from the tank headspaces are piped together and to a combustor for destruction. Each tank has a "thief' hatch on top for gaining access to the liquid when necessary. The thief hatches are set to relieve pressure should the pressure due to flashing, working, or breathing emissions from the liquids contained within the tanks get too high for the piping of the vapor capture system and combustor to accommodate.
Staff Interview: The Grywalski well pad was a brand-new well pad constructed by Ascent, and was in flowback stage at the time of our inspection. Our inspection occurred on the 8th day of the second round of flowback for this well pad. The wells are considered "dry" and so no condensate tanks will be present onsite when production begins. Prior to the flowback stage is "unloading." During unloading, water is extracted from the well at a consistent rate until gas becomes present in the wellstream. At that point, the well is shut in and the flow is switched to separation equipment to divert gas to the sales line. During flowback, the flow is split between temporary and permanent equipment in order to lessen the wear and tear on the permanent equipment. Water from the separator goes to temporary tanks which do not have emissions controls. At the time of our inspection, a portion of the produced water was also going to the permanent water storage tanks.
Page 2 ofS
TOUR INFORMATION
EPA toured the facility: Yes
Data Collected and Observations: We observed near-continuous emissions from the pressure relief devices atop the permanent water tanks.
Photos and/or Videos: were taken during the inspection.
Field Measurements: were not taken during this inspection.
CLOSING CONFERENCE
Requested documents: We requested the following documents, and summarized via e-mail on April 23, 2019:
Ascent's flow chart for its LDAR program (i.e. chain of responsibility and
procedures/tasks).
Records ofLDAR/FLIR surveys, repairs, and follow-up verifications conducted at
Ascent's Foxtrot well pad since its acquisition from Hess.
A repair log (date/FUR verification) for the items (i.e. weighted hatches, conservation
vents, vacuum breakers, and threaded connections) EPA noted to be emitting during our inspections on April 16-17, 2019.
A copy of the spec sheet for the combustor installed at the Grywalski well pad.
We also requested feedback on the following additional topics we discussed for consideration:
Explore using existing pressure gauges on tank vapor space to inform operators of what
sort of conditions the tanks undergo throughout dump cycles and in a variety of temperature conditions. The pressure data could be used to inform operators of what kinds of stress the pressure/vacuum relief devices experience, and potential options for alleviating that stress to prevent emissions/leaks. Would Ascent consider installing pressure gauges on existing tank batteries, or include them in the design of new well pads pending construction?
Assess the gasket material on every tank hatch that was acquired from Hess, and switch
out to known higher-performing material if not done so yet.
How are VOC emissions that occur from BTEX condenser vents on dehy equipment (e.g.
what was observed on the Ace pad) tracked and accounted for9
Ascent responded via e-mail on May 9, 2019.
Compliance Assistance: We discussed the items listed above as ways to inform continuous improvement of Ascent's operations and LDAR program. We discussed the importance of ensuring that combustors were properly sized for all stages of production at a well pad.
Page 3 ofS
Concerns: Where we detected emissions with the FLIR camera, we shared our observations with Ascent personnel.
-S---I-G----N---A-- T- - -U---R- --E---S---
Report Author:':;1J;:iA ~
Section Chief: ~~7~
/
'
(
Date: Date:
Page 4 of5
Facility Name: Ascent Resources~ Grywalski Well Pad Facility Location: 40.198638, -80.829331, Dillonvale, Ohio Date ofinspection: April 17, 2019
APPENDICES AND ATTACHMENTS
1.
Digital image/video log
2.
Digital images and videos on CD
Page 5 of 5
Facility Name: Ascent Resources - Grywalski Well Pad Facility Location: 40.198638, -80.829331, Dillonvale, Ohio Date of Inspection: April 17, 2019
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Natalie Topinka
" Ascent Resources - Grywalski Well Company/Faciiity Name:
Pad 5. Number of Images:
2
Image Number 1
2
File Name IMG 010._ipg
MOV 2317.mp4
2. Date(s) of Inspection: April 17, 2019
4. Street Address, City, State:
40.198638, -80.829331, Dillonvale, Ohio
6. Archival Record Location: CD-R labeled "Ascent Resources - Grywalski Well . Pad- Inspection photos/video 4/17/19"
Date 4/17/19
4/17/19
Description of Image
Wide-angle view of site Near-continuous emissions from
PRV on permanent produced water tanks
Appendices Page 1 of 1