Document Znr5QYxzDprQO11BDzXaXjVGd

c TECHNICAL DATA CASTABLES PLASTIC INSULCRETE Description: Service Limit: ASTM Class: Chemical Analysis: c Typical Physical Properties: Fired to (F) 230 1000 2000 2500 Application Methods: PLASTIC INSULCRETE is a Lightweight, High Temperature INSULATING CASTA BLE. PLASTIC INSULCRETE provides Exceptional Strength, Resistance to Thermal Shock and Low Thermal Conductivities. It is primarily used as a single layer insulation for Steam Boilers, Reactor Vessels, Process Heaters and Reheat Furnaces. 2500F P.C.E. Value: Cone 15 (2606F) Class Q Packaging: 50 lb. bags Thermal AIA SiOj CaO Fe203 TiO, MgO Alkalies L.O.I. Typical 38.5% 45.4 10.7 3.3 0.8 0.2 0.6 0.5 Typical Mean Temp 500F 1000F 1500F 2000F CAST `K'* 2.1 2.4 2.7 3.0 *(BTU/FT^/HR/F/IN) (as determined on CAST specimens, ASTM methods where applicable) Density (Lbs./Cu. Ft.) CAST 78-81 73-76 71-73 73-75 Linear Change, (%) CAST 0.0 0.0 to +0.1 -0.1 to -0.3 -1.1 to -1.6 Modulus of Rupture, (psi) CAST 179-208 94-127 65-90 414-451 Cold Crushing Strength, (psi) CAST 617-682 677-787 549-600 1011-1197 Material required to CAST 1 cubic ft. is 77-83 lbs. Water required to CAST 100 lbs. of material is 5.5 gal. Casting procedures are recommended in Brochure No. QS 102 Note: For GUNNED data see Gunning Mixes. Insulations. 13., :crr-5"-J--a *55: i A- oj'a ..( 5A*:&:e ic.os* a~ is. ' *-l TT '**5* 1"'*'' Y\.:' '* .. '**. ' ,,:e>*: . .... . :fce u* . 1' rc - r** :-P rz a* * -a--' -- > 'f. r'l'* v:= Pfizer QUIGLEY COMPANY INC. _ a subsidiary ol Pfizer Inc ,235 EAST 42nd STREET. NEW YORK. N Y 10017 ASARCO ELP 0000015 (NI/do/UH/dd/ma) UOlOVd AllAULDflQNOO THERMAL CONDUCTIVITY PLASTIC INSULCRETE (Gum*,J) 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 MEAN TEMPERATURE (F) i ASARCO ELP 0000016 SECTION V HEALTH HAZARD DATA ThreshOlO LIMIT valu( ------------------------------ NOiSANU UUU! -N 5 m/mi Respirable - 15 mq/m3 Total Dust.---------------------------------------------- AVOID inhaiation cffcctsof overexposure May cause eve and skin Irritation to those with sensitive-skin, and/or irritation In respiratory tract. ___________ EMERGENCY ANO FIRST AIO PROCEDURES Wash dust from skin with scan and wafer. Flush out eves_vdth.generous amounts of water. If Irritation persists, get medical attention._________________ ____________ SECTION VI - REACTIVITY DATA &TAVICITV unstable - CONDITIONS TO AVOiP stable iNCOMMTAilUTY iMltflUh 10 tVOKlJ X NONE NONE hazardous decomposition prooucts hAZAROOUS POLYMERIZATION MAY OCCUR WILL NOT OCCUR NONE CONDITIONS TO AVOID X NONE SECTION VII SPILL OR LEAK PROCEDURES STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPlLLEO Normal clean-up procedures. Care should be taken to avoid causing dust to become airborne. Vacuum cleaning systems are recommended. wa^te disposal methoo Disposal must be made in accordance with Federal. State, and Local regulations. SECTION VIII - SPECIAL PROTECTION INFORMATION respiratory protection (Specify typeJ Use of Dust Respirator is recommended when exposure limits may be exceeded. VENTILATION LOCAL EXHAUST special Local exhaust ventilation to collector dt containment recommended MECHANICAL (Central) ... OTHER to control dust to below exposure limit PROTECTIVE GLOVE* Leather or Rubber Gloves EVE PROTECTION Dust-tight goggles in dusty environment. OTHER PROTECTIVE EQUIPMENT SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO BJ[ TAKEN IN HANOLING AND STORING Good industrial hygiene practice requires that empolvee exposure he maintained below the recommended TLV. This is preferably achieved through the provision OToT a3e?|<La'te0vlntl lation where necessary. Where dust cannot be controlled In this way, personal respiratory protection should be employed. PAGE (2) 6po *xt-sm Legal responsibility Is assumed only for the fact that all studies reported here and all opinions are those of qualified experts. 20 Prepared by: H. C. Larson, Manager, Safety 5 Environmental Health May 6, 1982 I ASARCO ELP 0000017 SECTION V HEALTH HAZARD OATA THRESHOLD LIMIT VALUC 5 ma/m> Respirable - 15 mg/m3 Total Pust_. effects of ovcrcxfqsurc Hay cause eve and skin Irritation to those with sensitive skin, 7TU rSTWl'E "D'LTS I AVOID INHfll ATInw and/nr irritation In respiratory tract. EMERGENCY ANO FIRST AIO FROCCOURCS Wash dust from skin with soap and wafar. Finch out eves with generous amounts of water. If Irritation persists, get medical attention. STAHUlTV unstasl* - SECTION VI REACTIVITY DATA CONDITIONS TO AVOlO stablC incompatability iMtttnils to avoW; X HAZARDOUS decomposition products HAZARDOUS PQLVMCRlZATtON WAV OCCUR WILL NOT OCCUR NONE NONE NONE CONDITIONS TO AVOlO X NONE SECTION VII * SPILL OR LEAK PROCEDURES STEPS TO SC TAKEN IN CASE MATERIAL IS RELEASCO OR SRtLLEO Normal clean-up procedures. Care should be taken to avoid causing dust to become airborne. Vacuum cleaning systems are recommended. WA$T DISPOSAL method Disposal must be made in accordance with Federal, State, and Local regulations. SECTION VIII - SPECIAL PROTECTION INFORMATION ESPiflATo*v PROTECTION fSpecify^ typtj Use of Dust Respirator is recommended when exposure limits may be exceeded* ventilation LOCAL EXHAUST SPECIAL Local exhaust ventilation to collector dt containment recommended MECHANICAL (Cenerolj OTHER to control dust to below exposure limit > PROTECTIVE GLOVES Leather or Rubber Gloves EVE PROTECTION Dust-tiqht qoqqles in dusty environment. OThCA PROTECTIVE EQUIPMENT SECTION IX SPECIAL PRECAUTIONS PRECAyTjONS TO aj[ TAKEN IN HANOLINO ANO STORING Good industrial hygiene practice requires that emoolvee exposure be maintained below the recommended TLV. This is preferably achieved through the provision OTof afleVLa^E^vIntliation where necessary. Where dust cannot be controlled in this way, personal respiratory protection should be employed. *f*GV.s!s Legal responsibility Is assumed only for the fact that all Form OSHA-20 Rtv. My 72 studies reported here and all opinions are those of qualified experts. Prepared by: M. C. Larson, Manager, Safety S Environmental Health - May 6f 1982 IV ASARCO ELP 0000018 c TECHNICAL DATA GUNNING MIXES PLASTIC INSULCRETE" Description: Service systems. ASTM Class: Chemical Analysis: c Typical Physical Properties: Fired to CF) 230 1000 2000 2500 PLASTIC INSULCRETE is a Lightweight, High Temperature Insulating GUNNING MIX. PLASTIC INSULCRETE provides Exceptional Strength. Resistance to Thermal Shock, and Low Thermal Conductivities. It is primarily used as a single layer insulation for Steam Boilers, Reactor Vessels, Process Heaters and Reheat Furnaces. 2500T P.C.E. Value: Cone 15 (2606F) No Designation Packaging: SO lb. bags AIA SiO, CaO Fe,Oa TiO, MgO Alkalies L.O.I. Typical Thermal Conductivity: 38.5% 45.4 10.7 3.3 0.8 0.2 0.6 0.5 Typical Mean Temp 500F 1500F 2000F GUNNED K' 2.4 2.7 2.9 '(BTU/FT'/HR/F/IN) (as determined on GUNNED specimens, ASTM methods where applicable) Density (Lbs^Cu. Ft.) GUNNED 87-95 85-89 76-84 84-90 Linear Change, (%) GUNNED 0.0 -0.2 to -0.3 -0.1 to -0.5 -1.6 to -2.3 Modulus of Rupture, (psl) GUNNED 276-600 261-355 121-299 725-1197 Cold Crushing Strength, (pal) GUNNED 940-1698 1521-1720 513-1025 2069-2863 Application Methods: Material required to GUN 1 cubic ft. is 89-96 lbs. Recommended water required for pre-wet is 4-6%. Gunning procedures are recommended in Brochure No. QS 102 io'T'sa-a '-c -cor';*1 Note For CAST data an Caatablaa. Insulations. '96C a*- wpiWihj*ca*,sta-ao"*te*se'3^'wt`Wcs:"s'a'?..>t*.: s-*?\:c f- j- "'-e;?:== ' earach-e=c-aa;*. *C A C`C C*T0 c*,*"T'",`A5 Jv C-'O'C* 2hC 3*8 .ASq^^tS *- AAsqis'si .uca.-MAS'TisJlT' AND NO : =C- C.ce. ;,rcr> 3*c"ocjfce,e.,<i',3ih9ri3,f' ra'e^r^De'c sev' ,o,3,,*c-'OOte .'e'i C--? e. C\c *erj*ec a**. I'-e* -sa l QUIGLEY COMPANY INC. a subsidiary ol Pfizer Inc ?35 EAST 42nd STREET. NEW YORK. N Y 10017 ASARCO ELP 0000019 CONDUCTIVITY FACTOR - (8TU/FP/HR/F/IN) THERMAL CONDUCTIVITY PLASTIC INSULCRETE (C.t) i ASARCO ELP 0000020