Document Znn7dwapQD15BYQEmq4pz1RMJ
THE MOUNT SINAI MEDICAL CENTER
ONE GUSTAVE L LEVY PUCE NEW YORK. N Y 10029
4>TMCinvmisirr
OtMWIOM
Mount Sinai School of Medicine 'The Mount Sinai Hospital
April 11, 1979
He. Robert S. Hagdelaln, President Nilflsk of America, Znc. 201 King Manor Drive King of Prussia, Pennsylvania 19406
Environmental Sciences Laborolory Cummuigi Basic Science! Building 10 Baal 108 Street New Yor*. New York 10029
1212> 050-0173
Dear Mr. Magdelaln:
This will report the results of air sampling tests conducted, in October 1978, to determine chrysotlle asbestos concentrations dur
ing brake repair work.
Our major objective was to determine the efficiency of the Nilflsk Asbestos System utilizing HEPA filters, particularly with regard to submicro8copic asbestos fibers. Studies conducted in our Laboratory and elsewhere have demonstrated that free asbestos fibers present In brake drum dusts are predominantly shorter than 5pm in length. In particular, It was found that about 75% of the fibers In such dusts were less than 0.3pm In length, as determined by transmission electron microscopy. Thus, the optical microscopic technique used by 0SHA for determining asbestos levels In workplaces
(In which only fibers 5ym or longer are counted) would overlook a large number of asbestos fibers in air samples. That la, the total
asbestos exposure in terms of fiber number, mass and surface area would be significantly greater than the levels determined using the OSHA fiber-counting method.
Therefore, It was of considerable interest to us to have an oppor tunity to test the efficiency of the Nilflsk Asbesto-Clene System. To do this personal air sampling was carried out on the exhaust of a HEPA-ftitered vacuum dust collector and, simultaneously, on a garage mechanic cleaning a brake drum with the Nilflsk brake en capsulation cylinder. Three such tests were made. Background air samples, also using personal air pumps, were taken.
Por each of the teats, a sample of settled dust was taken from the brake drum. The dusts were aftalvzed by x-ray diffraction In the step8can mode to quantitatively determine asbestos contents, using a
technique previously published. Asbestos was found In all three samples, ranging from 2.5% to 4.5% by weight.
The membrane filters were analyzed by both transmission electron microscopy (X25.000) and by the standard OSHA fiber-counting technique, employing phase contrast optical microscopy. The results are as follows:
CAT-1020195