Document ZnVLxKv54YxzDxqdaDen1gLOZ

DownloadRandom document
Comment # MS / Commen Organisati t overall on number 32 Extent of the comment Selected Text 51 Chapter No. / Section No. 2 0 EURATEX 498 pter No. / Section No. 0 0 0 Chapter title Page # 724 BAT (if relevant ) BAT 7 BAT techniq ue (if relevant ) Polluta nt / parame ter concer ned (for monitor ing and BATAEL) Major/ Selected information subject to the comment Minor Comment description comment Once every month Major high monitoring frequency has no added value Proposal for modification _x000D_ Add in headline of third column "if relevant"_x000D_ Add that the measuring only takes place at the point of release_x000D_ _x000D_ frequency every 3 months for all parameters_x000D_ _x000D_ copper, nickel, zinc only relevant when dyeing ;_x000D_ PFC not relevant for all processes but for finishing;_x000D_ delete surfactants (not relevant for wastewater, because biodegradability and elimination are regulated by EU "detergents" directive)_x000D_ _x000D_ add footnote 2 (only direct discharges) : for Colour hoi, total p, toxicity, biodegradebility_x000D_ add footnote 1 to metals and HOI_x000D_ _x000D_ Rationale / supporting data _x000D_ he colour of direct discharges is stable_x000D_ Therefor a monthly frequency gives no added value for the company nor the authorities_x000D_ _x000D_ Additional testing costs should be avoided_x000D_ _x000D_ for total P - only applies for direct and not indirect discharges_x000D_ _x000D_