Document ZnL10pE2vp9RN1X1GN16MwzxY

See 0is t ribu 11 on P. M. Zakriski f lELO POINT on oapr. R BL.C* NO. Brecksville R & D Center . PifiCO PO'Nt OR DEPT. ti GUC3. NO. ! Brecksville R & D Center, 0/8506 Personal Protection from Vinyl Chloride During Source Testing Ifl L6TT6R OAT6 THIS LfiTTER Oec. 13, 1976 To the best of my knowledge, no one has measured the vinyl chloride concentrations on the nof tops where source measurement are to be made. It is probable that if a source is in compliance its vinyl chloride concentration will be no greater than 10 ppm. Then, with d lution by the outside air the roof top concentration can not be greater than 10 ppm. Hdwever, in lieu of measurements to prove that roof top concentrations are below 1 ppm we w 11 foljow the following procedure. We will amend this procedure as our roof top measure ments indicate we can safely do so. PROCEDURE The source testing team will ajways take to the roof the following equipment: a) Organic vapor analyzer or H-NU organic vapor analyzer. b) NIOSH approved carbon cannisters for vinyl chloride and face masks. Bendix PMCC tubes for vinyl chloride and micron air pumps. Th i following procedure will be followed: a) Personnel sampling tubes and pumps will be worn and the tubes' analyzed upon return" to the lab. ' b) Measurements with the OVA or H-NU will be made often. When these measurements indicate average levels in excess of 1 ppm the masks with carbon cannisters will be worn. Work will be permitted with face mask and cannister as long as the apparent average pollution level is below 25 ppm. When the.OVA or H-NU measurements show the pollutant level (vinyl chloride and/or all others) to be greater than 25 ppm (on the average), then work will be carried on only with either a Scot air pack or an air line respirator from the building. In the event that neither of these protections can be used, then no further work will be carried on until the average pollutant level falls below 25 ppm. When the levels retreat below 25 ppm, then testing may be resumed. We see the very strong possibility that our OVA or H-NU and PMCC tube measurements will shc.v that roof top levels of vinyl chloride are below 1 ppm. When this situation has been documented, we will dispense with the requirement to take masks and cannisters. B. F. G00CM c DEC 2 1 1976 DFcrfinnii 1 fi> (*.. Paul M. Zakrhski 1-000 54 2- - PtSTRlBUT{QN C. E. TiCus R. K. Zimmer R. D. Hardesty M. A. Paschal .cc: .. C. H. Lufter M. Lukity J. W. Born-O. S. Kurtz-R. E. Harris E. B- Katzenmeyer, Jr. - Akron K. J. Kaminski - Cleveland J. 0., Fannin - Louisville J. W. Bloodworth - Calvert City R & D Files 1-000 55 r SEE DISTRIBUTION A P. M. Zakriski on pgo.Fiet-O POINT OEPT. & QLOQ. ondub POINT OGPT. G* OLOG. fsjo. Dec. 14, 1976 Passive Personnel Monitor Badges for Vinyl Chloride and Other Organic Vapors Culf South Research Institute (GSRl) has developed a technology base which leads them to believe that they can demonstrate the feasibility of a vinyl chloride detector badge, lhat is a passive dosimeter that does not need a battery operated pump and will replace the Bendix tube for measurement of personnel exposure to vinyl chloride. They would like \ery much to present a proposal to B.F.Goodrich for the purpose of demonstrating the leasibility of this badge. I expect the cost of this proposal would be in the neighborlood of $25*000. : .r have discussed this subject with them. They have not completely revealed their technology I ase to me but they have given me the following insight. Their work directs them to i pproach the badge from the point of specific adsorbants, that is different adsorbants or different organic vapors. They do not use or intend to use carbon as a adsorbant. hey intend to prepare badges with as many as a dozen separate compartments. Some of hese compartments will hold the same adsorbant and therefore be used for replication of analyses. Other compartments will hold other adsorbants which will enable the same badge 0 measure other pol1utants. iey have already proposed a feasibility study to a pharmaceutical house, for a prototype >adge to be used by operating room personnel. In this case the badge will be used for :he f1uoro-chloro-carbons used as anesthetic gases. I mention this to indicate that they ire serious in their work and they do have active efforts to invent specific dosimeter >adges. _et me talk briefly about the agreement that GSRl would like to enter into when they jndertake a contract. For the limited amount of approximately $25,000 they would be >reparing a badge feasibility study- ! have presumed our interests would be in vinyl :hloride at first, but it could be in something else, for instance, benzene. This work ^ould take 1-2 months. At that time, BFG would own the patent and be in a position to field test and then produce privately or commercially, the dosimeter badge. GSRl would -lot plan to go into any sort of commercial production of the indented dosimeter. In the *vent BFG does not like or wish to pursue the findings of GSRl relative to the badge, then GSRl would, by contract, retain all rights and privileges to the findings and inventions Df the work. Then, they could sell it to someone else. They indicated to me that they simply want to guarantee that their research work doesn't become permanently locked up in unexploited contracts. 1 firmly believe that B.F.Goodrich should ask GSRl to submit this vinyl chloride badge proposal for careful review. If that review indicates that the cost for this feasibility study is reasonable and the business aspects are sound we should seriously consider acting on this proposal. My reasoning is that I believe the cost of personnel testing for vinyl chloride can be signlficantly reduced by employing a badge and the quality of the measure- ents can be significantly improved by eliminating the pump. When it appears that B.F.Goodrich does wish to review this pr its presentation. ' l will arrange for Paul M- Zakriski I-OOQ 55 r ;i DISTRIBUTION C. H. Lufter R. J. Fawcett R. Vf. Strassburg E. B. Katzenmeyer, A. W. Clements R, D. Scott J. A. Klupar B. M. G. Zwicker D. E- Ley R & D' Files Jr. -2- 1-000 57 ri