Document ZnK8Y1q2VaZRk3b1b7KGaGpvd

ANALYTICA CHIMICA ACTA 391 GAS CHROMATOGRAPHIC ANALYSIS OF CHLORINATED BIPHENYLS HAROLD WEINGARTEN, WILLIAM D. ROSS, JAMES M, SCHLATER and GUTHRIE WHEELER, JR. Research and Engineering Division, Monsanto Chemical Co,, Dayton, Ohio (U.S.A.) (Received July 19th, ig6i) In the course of research it became necessary to establish a rapid and reliable analy tical method for biphenyl, and the mono- and dichlorobiphenyls. Although infra-red methods were adequate for two or three component mixtures1 we frequently had to deal with mixtures containing from 4 to xo components. Gas chromatography provided not only a qualitative but also a quantitative method. EXPERIMENTAL Apparaltis A Barber-Colman Model 20 gas chromatograph equipped with a stiontium-90 diode argon ionization detector was used. Capillary columns The xoo-ft. stainless steel polypropylene glycol 750 (Dow Chemical Co.) column (PPG No. 1) was originally purchased from Barber-Colman. However, through ex Component A Biphenyl B 2-Chlorobiphenyl C 3-Chioro biphenyl D 4-Chlorobiphenyl E 2,6-Dichlorobiphenyl F 2,2'-Dichlorobiphenyl G 2,3-Dlchlorobiphenyl H 2,4-DicWorobiphenyl I 2,3'-Dichlorobiphenyl J 2,3-Dichlorobiphenyl K 2,4'-Dichloroblphenyi L 3,5-Dlctdorobiphenyl M 3,3'-Dichlorobiphenyl N 3,4-Dichlorobiphenyl O 3,4'-Dichlorobiphenyl P 4,4'~Dicti!orobiphenyl TABLE 1 Petalive retention lime (biphenyl *= i) PPG No. t* PPG ,Yo. 2* A pieton L 1.00 r.38 1.82 1.91 2.05 2.13 2.29 2.29 2.71 2.92 3.90 4.20 1.00 1.56 2.20 2.31 2.50 2.64 3,00 3.00 3-44 3^5 3-74 3.8S 5.06 3.20 5.45 3.86 1.00 I-3I 1.83 1.91 1.83 1.80 2.41 2.48 2.52 2.62 2.69 3-44 3.82 3.99 4'3 4-3 * 9 p.s.i.g., 165 >> 36 p.s.i.g., 175" c 30 p.s.i.g., 185 Anal, Cltim, Ada, 26 (1962) 391-394 STLCOPCB0003572 WATER PCB-SD0000054542 1 392 H. WEINGARTEN, W. D. ROSS, J, M. SCHLATER, G. WHEELER tended use the coating was depleted. It was recoated in our laboratories by flushing through the capillary a 10% solution of Dow poly-piopylene glycol 750 in 11-pentane under 200 p.s.i.g. This recoated column is referred to as PPG No. 2 and is seen to differ significantly from PPG No, 1 (see Table I). The 200-ft. stainless steel Apiezon L column was purchased from Barber-Colman. Instrument parameters Injection port temperature, 270; detector temperature, 240; column tempera tures between 165 and 185; eluant pressure between 5 and 40 p.s.i.g.; scavenger flow, 150 ml/min; split flow, 300 ml/min measuied as 10 p.s.i.g.; sample size 1.0 fi\. Quantitative analysis An Ott compensating planimeter was used to measure peak areas, which were generally proportional to mole percent. However, to avoid errors due to deviations in linearity, standard mixtures were run concurrently to provide correction factors when necessary. Chlorinated biphenyls All of the mono and most of the dichlorobiphenyls have been adequately character ized and reported in the literature. Samples of 2,2'-; 2,4'- and 4,4'-dichlorobiphenyls were kindly supplied by Dr. A. M. Ellenburg, Monsanto Chemical Co., St. Louis. All others were prepared by Gomberg techniques2. The 2,6-isomer was not isolated but was obtained in a Gomberg mixture and identified as described by Weingarten1. The 2,3'- and 3,4'-isomers also were not isolated but were prepared in a Gomberg mixture and identified by relative abundance1 and by analogy' with relative retention times for other o-p pairs (ortho always preceded para). RESULTS AND DISCUSSION ' Biphenyl, the 3 monochlorobiphenyls and the 12'dichlorobiphenyls are nearly com pletely resolved by gas chromatography on a Barber-Colman Model 20 capillary column instrument. The results are summarized in Table I and Fig. 1. On the whole we found the chlorobiphenyls to behave much like the methylbiphenyls as reported by Beaven el at.3. The components tend to form clusters accord ing to the degree of ortho substitution. Dichlorobiphenyls with two ortho substituents have the lowest retention times, those with mixed ortho and para (niela) have inter mediate retention times and those with only para and meta substituents have the longest retention times. This phenomenon has been correlated with conjugative effects3. We also found that vicinal substitution causes a higher retention time for the 2,3-isomer relative to the z^'-isomer1 but not for the 3,4-isomer relative to the 3,4'isomer. The most valuable feature of the two columns used, PPG No. 2 and Apiezon L, is the manner in which they complement each other. On the Apiezon column the last of the monochlorobiphenyls overlaps the first of the dichlorobiphenyls and the 2,6isomer has the same retention time as the 3-isomer. This region is completely resolved on the PPG column. The Apiezon column barely separates the 3,4- and 3,4'-isomers while the PPG completely resolves the two. On the other hand, the PPG column does not distinguish between the 2,5- and 2,4-isomers which the Apiezon resolves. The Anal, Chim. Ada, 26 (1962) 391-391 STLCOPCB0003573 WATER PCB-SD0000054543 GAS CHROMATOGRAPHY FOR CHLORINATED BIPHENYLS 393 Apiezon also provides a more satisfactory separation of the 2,3- and 2,4'-isomers. The most striking contrast between the columns is the reversal in position of the 2,6-and 2,2'-dichlorobiphenyls. On the Apiezon column the 2,2'-isomer has a lower retention time than the 2,6-isomer as well as the 3- and q-monochlorobipbenyls, This sequence is completely reversed on the PPG column; both the 2,6- and 2,2'-isomers follow the monochlorobiphenyls and the 2,6-isomer preceeds the 2,2'-isomer. Another contrast involves the shift of the 3,5-isomer from the m-p cluster on the Apiezon column to the o-p cluster on the PPG. ACKNOWLEDGEMENT The authors wish to thank Donald R. Beasecker and William T. Cave for many stimulating and useful discussions and Gary A. Clixehens for his valuable assistance. Anal. Chitn. Acta, 26 (1962) 3Qr--39*1 STLCOPCB0003574 WATER PCB-SD0000054544 394 H. WEINGARTEN, W. D. ROSS, j. M. SCHLATER, G. WHEELER SUMMARY Capillary column gas chromatography is reported as an analytical method (or biphenyl, the 3 monochlorobiphenyls and the 12 dichlorobiphenyls. Two complementary columns were used permitting, in effect, total resolution. RESUME La chromatographie en phase gazeuse, avec colonne capillaire, est proposee pour l'analyse de hiphenyles chlor4s (biphenvle, monochlorobiphenyles, dichlorohiphenyles). Deux colonnes complAmentaires sont utilisees pour avoir une separation totale. ZUS AMMEN FASSUN G Beschreibung einer gaschromatographischen Methode mit Kapillarlcolonne zur Analyse von chlorierten Biphenylen (Biphenyl, Monochlorbiphenyle, Dichlorbiphenyle). Durch Anwendung von 1 Zusatz-Kolonnen geling-t eine vollsthndige Trennung. REFERENCES 1 H. Weingarten, J. Org. Client., 26 (1961) 730. 2 R. Huisgen and R. Grashey, Ann., 607 (1957) 50. 3 G. H. Beaven, A. T. James and E. A. Johnson, Nature, 179 (1957) 494 A. T. James, Anal. Client., 28 (1956) 1564. Anal. Chilli. Ada, 26 (1962) 391 -394 STLCOPCB0003575 WATER PCB-SD0000054545