Document Zn95VJkN6YJkJa6mKoqrNQGZV

4. 1 Ii INTERNAL CORRESPONDENCE r UNION CARBIDE CORPORATION technical center PO BOX B3B1. SOUTH CHARLESTON, WV 35303 7"N,i. E. Rucker Oiv r,-or- 512/2009 Locot<Gr> Area Copy tC g |_| Avashia, M.D. - 512/33 J. w. Barna - 2009/6 W. L. Browning - 2009 " R. E. Coyner - 2009 T. L. Grittie - 380 C. P. Maxwell - 701/2 B. R. McMakin - 2009 April 3, 1987 EM&TS - HS&EAOr-Kjtr-iiEiny Ocpt Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of the asbestos exposure monitoring performed on construction employees by the site IH personnel at the Sistersville Plant. Employees were monitored over a three day period while repairing and covering asbestos insulation on the stills in the rectification area of the Sistersville Plant. Employees were equipped with coveralls, boots, gloves, and head cover. In addition employees wore supplied air respirator on the first day and HEPA cartridge equipped respirator for rest of the period during the repair work. The monitoring results indicate that the exposure levels were well below the 0.1 fiber/cc Action Level standard established by 0SHA. Please inform the monitored employees of their exposure monitoring results as soon as possible. Also, have all monitored employees to sign and date this report and return to M. A. Patel, Building 701-330, Technical Center. If you have questions, please feel free to call me at extension 3750. Attachment MAP:rab 2214P X - -S-M Manhar A. Patel UCC 024564 ASBESTOS EXPOSURE MONITORING SISTERSVILLE PLANT Date 1-9-87 1-9-87 1-12-87 1-13-87 1-13-87 Sanple Type Employee Nare C. E. Rose Sanpling Tine - Min. Air Cone, fibers/cc 55 <0.02 TWAg fibers/cc - COMMENTS Repairing/covering insulation on the stills in the Rectification area. 0. R. Sanples 53 0.01 - Repairing/covering insulation on the stills in the Rectification area. J. C. Hubbard 201 0.002 - Repairing/covering insulation on the stills in the Rectification area. T. K, Miller 290 0.03 - Repairing/covering insulation on the stills in the Rectification area. J. A, Casto 294 0.04 - Repairing/covering insulation on the stills in the Rectification area. 2214P UCC 024565