Document ZJdZRR1dMoEkDbZMJqD9m707L

ROCKBESTOS WIRE & CABLE ASBESTOS Insulated Wire & Cable ROCKBESTOS WIRE & CABLE CO. DIVISION OF CERRO CORPORATION NEW HAVEN A - CONNECTICL RBB 00470 SC-ELEC-00052 i. Fir* Na. 31-C -47J a ll* N *. 3 I-C -4 7 . < < ROCKBESTOS WIRE & CABLE CO. Division of Cerro Corporation Main OfficS and Works NICOU AND CANNER STS., NEW HAVEN 4, CONN., U. S. A. O o JM JO-42 > Zo u rt nN 0 oZ u PAINTED >N U.S-A. 00471 ROCKBESTOS is the name -for a wide fine of wires, cables and cords, including more chan 125 different standard constructions, which have been designed and developed to give long and depend able service under severe operating conditions. Eariy in 1918 a small group of Roclcbestos Elec trical Engineers and Chemists perfected a method of applying asbestos to wires and cables as a heat resisting electrical insulation. This first step result ed in the production of wire that industry and elec trical engineers had been looking for. Here was an insulated conductor resistant to high tempera tures, aging, corrosive fumes, grease, oil and flame. Success from the start--and just die beginning for this company which was later to distinguish itself to be the only company in industry devoted ex clusively to the manufacture of permanently insu lated wires and cables. Rockbestos grew along with the then rapidly growing electrical industry, solv ing its electrical insulation problems as they became apparent with this unique mineral, ASBESTOS. Other materials are often combined with asbes tos, i.e. Varnished cambric, Synthetics, DuPont `Teflon" Tetrafiuoroethylene resin, cotton, rayon, nylon and glass, to provide special characteristics. Two broad lines of permanently insulated wires, cables and cords--Rockbestos A.V.C. asbestos-var nished cambric insulated (N.E.C. Types AVA and AVB) and Rockbestos ALL-Asbestos (N_E.C. Types A, AA, AI, A1A and AF)--have been de veloped for innumerable industrial applications. Rockbestos engineering and research are constantly abreast of electrical problems in both science and industry, providing answers through the develop ment of trouble-free, ageless electrical insulations designed for each specific application. May we offer you our research facilities for the development of special wires designed to meet any unusual re quirements. RBB 00472 t 9 This is the Rockbestos Handbook and Catalog No. 10-H, which illustrates and describes wires and cables insulated with Asbestos Varnished Cambric, and All Asbestos insula tions for use where wiring in electrical products or in the power, control and lighting circuits of industry is exposed to heat, corrosive fumes, grease, oil or fire hazard. Also contained in this catalog are Rockbestos special con structions developed for special and specific applications. All data subject to change without notice. ROCKBESTOS WIRE & CABLE CO. DIVISION OF CERRO CORPORATION MAIN OFFICE AND FACTORY: Nieoll and Canner Streets, New Haven, Conn. RBB 00473 Table A A-300 B BH BS Page 600 Voit Rheostat Wire............................................................. 300 Volt Rheostat Wire, High Temperature........................ 600 Volt Switchboard Wire (Solid) ....................................... 600 Volt Switchboard Hinge Cable....................................... 600 Volt Switchboard Wire (Stranded).................................. 20 24 17 18 17 C CL E EL EMA 600 Volt Lighting Wire (Solid) ............................................. 600 Volt Lighting Wite--Lead Sheathed .............................. 600 Volt Power Cable--Single Conductor.............................. 600 Volt Power Cable--Lead Sheath, Single Conductor...... 1000 Volt Lead Wire................................................................... 12 14 9 15 27 FS FSB H HL L 300 Volt Fixture Wire............................................................... 300 Vote Fixture Wire (Braided) ........ 5000 Volt Power Cable, Single Conductor................... 5000 Volt Power Cable, Lead Sheath, Single Conductor 600 Volt Motor Lead and Apparatus Cable .......................... 25 25 9 15 13 LH-LHV LHG-LHT MD ML Industrial Heating Cable........................................ Special Industrial Hearing Cable ........... ......... Heating Cable Kits and Thermostat .. .............29 .... 30 31 600 Volt Control Cable, (AWG No. 12-19/25).................. 600 Volt Mining Cable................................................................ 11 26 MT 600 Volt Control Cable (AWG No. 9-19/22)....................... R 600 Volt Power and Rheostat Cable ....................................... RF 600 Volt Apparatus Cable. Flexible........................................ RF-300 300 Volt Rheostat Wire (Flexible Stranded) ......................... 13 21 22 24 TC-TCC-TCS W XB-XBS-XBH ZM Thermostat Control Wire............................................................ 300 Volt Apparatus Cable, Extra Flexible.............................. 600 Volt Switchboard Wires, Type TA.................................. 1000 Volt Hookup Wire............................................................. 28 23 19 27 RBB 00474 ASBESTOS * OUR BASIC RAW MATERIAL In entering upon a description of Rodcbestos wires and cables, a brief outline of the characteristics of asbestos, the chief material used in theif insulation, is a logical beginning. Asbestos is a mineral, consequently inorganic in its na ture, and in this principal feature different from all other types of material in use for insulating wires and cables. Asbestos fibres are solid, that is to say they have no cap illary opening through their center like cotton, wool or other organic fibres. Because of this fact, there is no ten dency for individual asbestos fibres to act as capillaries if their ends are exposed, and it only becomes necessary to fill the voids of interstices between the fibres to pro duce a relatively impervious layer. Asbestos has demonstrated its ability to withstand time without the deterioration that occurs in other forms of electrical insulating materials such as rubber and the gen eral class of organic fibres. Furthermore, it will not rot or carbonize under any conditions. It may be fairly stated indeed that asbestos is ageless, and time, as every engi neer well knows, is a much more exacting test of a material than almost any laboratory accelerated life test which can be made. During the centuries since the as bestos was formed, it has been exposed to high earth temperatures and, as earth cooled, to moisture and the wide variety of earth acids and alkalis, all with no apparent change in any of its properties. We have investigated the world's sources of asbestos to find and secure the softest, silkiest, purest, long fibred asbestos . . . and we find it in certain deposits of Chrysotile (Serpentine Group)--the aristocrat of the asbestos family. Chrysotile is a hydrated magnesium silicate which occurs in crystalline form in veins or striations in the mother rock and is widely distributed. Each crystal is a "fibre", square in cross section, having a diameter of about 1/500, 000 inch and a length equal to the width of the vein. There are a number of sources of Chrysotile fibre, the principal ones being Rhodesia, Canada, Russia, Arizona and Australia. The largest deposits arc in Rhodesia and Canada. Asbestos retains its strength and fibrous form under all conditions except extremely high temperatures. Chryso tile asbestos in crude (unopened form) begins to lose some of its water crystallization at about 450C and is almost completely dehydrated at 850C. It fuses at about 1500C When applied to wires or cables in felted form, its low heat conductivity enables it to withstand melting the copper conductor by passage of high currents without material loss of its mechanical strength. Tests of fabrics woven of Chrysotile asbestos show that after three hours at 500C they still have their original tensile strength. Asbestos, after it is mined, is broken up, fiberized and cleaned. It is then combed and carded into soft, Huffy roving. In this form it is applied to the conductor, impregnated with neutral insulating compounds, and compressed into the felted wall which is Rockbestos insulation that is not only fireproof but practically impervious to the destruc tion normally caused by heat and moisture, oil, grease, corrosive fumes or age. What a material to use where endurance and resistance to deterioration ate so important! Hard as a rock in the vein, asbestos is soft as silk when fiberized. Each silky fiber is a crystal i/iOO,OOOlh of an inch in diameter. A million-year-old handful! This asbestos has been completely fiberized and prepared and is note ready to be carded into roving. RBB 00475 WHY ROCKBESTOS A.V.C. WAS DEVELOPED Since the early days of electrified industry, there has been a definite need for an electrical conductor insulation which would operate dependably in elevated ambient temperatures. High ambient temperatures were a prob lem then as they are today, and the performance of or dinary wires and cables at that time was restricted by the very nature of the materials used. Rubber, for instance, while known to be high in moisture resistance, was af fected by high temperatures which caused it to become dry and porous limiting its length of effective service. The life of straight varnished cambric insulations too was seriously affected by high ambient temperatures which tended to cause deterioration of the tapes. Early asbestos insulations proved unsatisfactory because they consisted only of a series of asbestos braids filled with paint or other compound. Recognizing that high temperatures and moisture were the major threats to the life of insulations, Rodcbestos Engineers designed and developed their A.V.C. construc tion. This A.V.C. constriction used as a basis dense felt ed walls of thoroughly impregnated asbestos to form a continuous insulation which would permanently resist heat, flame and moisture. High dielectric varnished cam bric tapes wete added as an insert between the felted as bestos to give added dielectric strength and moisture resistance. In this combination the felted asbestos also provided protection for the Varnished Cambric tapes against mechanical damage, deterioration from oxida tion and prevents the formation of a continuous carbon path from conductor to ground. This basic construction was covered overall with either impregnated asbestos or flameproof cotton braids. This new Rodcbestos A.V.C construction was designed primarily to safely and depen dably carry electrical Toads in high ambient locations and to withstand additional operating hazards such as attacks of chemicals, oils, grease and fumes. Here was an insu lation designed to give a long fife of dependable oper* ation under severest conditions. Since the introduction of Rodcbestos A.V.C. wires and cables in 1927, many millions of feet have been installed throughout the world under normal and abnormal oper ating conditions. These installations have covered a wide range of high temperatures and moisture conditions in practically every known industry. Rodcbestos Field Engi neers have constantly checked many of these installations in various industries since 1927 to check field conditions against long time tests run by our Research Laboratory to confirm the ability of Rodcbestos A.V.C. to meet un usual service conditions. Because of their successful oper ation, these asbestos-varnished cambric wires and cables were induded in the National Electrical Code in the 1937 Edition and designated as N.E.C Types AVA, AVL and AVB. The trade name "A.V.C" as registered by Rodcbestos and used commerdaliy is synonymous with National Electrical Code Types AVA, AVL and AVB. That is, A.V.C finished with asbestos braid is Type AVA, with lead sheath is Type AVL and with cotton braid is Type AVB. THE Hi-1 STORY Maximum current carrying capacities of insulated con ductors are determined within practical limits by the murifflinn temperature the insulation will stand without undue deterioration. The Code in rating this original Rodcbestos A.V.C. con struction permitted it a higher temperature limit than ordinary insulations because its impregnated felted as bestos walls safely resisted deterioration under high am bients and the heat from current loads. Chapter 10, Ta bles 1 and II, under "Allowable Current-Carrying Capadries at 30C" list Rodcbestos A.V.C Type AVA con struction with greater current carrying capadty size for size than for cables with ordinary insulations. The prac tical advantages of Rodcbestos A.V.C. begin here. As ambient temperatures increase and correction factors are applied, A.V.C is de-rated far less than ordinary con structions, all because of its insulation. At 70C, for instance, other types of Insulations are de rated as much as 6)% while Rodcbestos A.V.C. is de rated only 29%. At ambient temperatures in excess of 85C * limiting point for other types of insulations, Rodcbestos A.V.C. rated at 110C continues to provide permanent protection for electrical circuits. Plant layouts and expansion programs are given greater flexibility by installing Rodcbestos A.V.C. because not only does it provide greater current carrying capadty for intermittent demands and future load growth in existing dreuits, but the installation of heat generating equipment is not restricted by its nearness to vital electrical circuits. The fact that you can use a smaller sized cable to carry a given load can start a whole series of cumulative sav ings. Smaller cable means smaller conduit and fittings. Easier, quicker installations, plus years of dependable perfor mance, prove Rodcbestos Hi-I A.V.C.... Your Best Buy. ROCKBESTOS A.V.C. CONSTRUCTION I tI (1) First impregnated felted asbestos wall. (2) Varnished cambric tapes. (3) Second impregnated felted asbestos wall. (4 j impregnated asbestos braid for Type AVA cables. (Flameproof cotton braid for Type AVB cables.) (Lead Sheath for Type AVL cables.) RBB 00476 TYPICAL APPLICATIONS FOR POWE WHERE SUBJECTED T< POWER CIRCUITS UP TO 5000 VOLT SBIVICE Standard Rockbestos A.V.C (Code Type AVA) Power Cables ate available in voltage ratings of 600 to 5000 volts. They are designed to protea circuits that must operate without failure un der continuous exposure to high temperatures and other severe operating conditions. Copper shielding can be provided where re quired. They are available in single or multi-conductor construc tions with either lead sheaths or asbestos braids. Interlocking armor can be furnished to special order. Radcbestos A.V.C. (Code Type AVA) Power Cable constructions are approved by the Natiooil Electrical Code, listed by the Underwriters' Laboratories and conform-*to NEMA standards. CONDUIT WIRING AROUND FURNACES, OVENS, SOAKING PITS, BOILERS, ETC. Rodebestos A.V.C Power Cables and Lighting Wires can be tun in conduit as they are built to withstand the normal moisture con ditions resulting from condensation caused by heating and cooling cycles. In cases where power and lighting circuits are exposed to high temperatures in combination with excessive condensation ot complete submersion, use lead sheathed Code Type AVL. LIGHTING AND POWBt CIRCUITS Rockbestos Hi-I A.V.C. (Code Type AVA) Lighting and Power Cables are high temperature cables. This A.V.C construction-- two layers of impregnated felted asbestos encasing the varnished cambric--permits continuous operation at copper temperatures of 250F (110C), thus making Hi-I cables ideal for high ambient "Hot Spot'' locations or, in normal ambient installations, per mitting the use of smaller cables with consequent savings of cop per, conduit, fittings and man-hours of labor as compared with cables having ordinary insulation. 6 RBB 00477 LIGHTING and CONTROL CIRCUITS HIGH TEMPERATURES 9 RHEOSTAT AND APPARATUS WIRING Rockbestos All-Asbestos Rheostat Wires and Cables were design ed primarily for open wiring. Operating temperatures of 125C for 600 volt ratings and 200C for J00 volt applications can be safely met as constant elevated temperatures will not cause the compounds to fail away or flake off even through repeated heat ing and cooling cycles. It is especially recommended for grid jumper connections from grids to faceplates, ovens and element leads on well type anneal ing furnaces and open wiring exposed to extremely high temper atures, corrosive fumes, grease, oil or fire hazard. SWITCHBOARDS AND PANEL BOARDS Millions of feet of Rockbestos fireproof A.V.C (N.E.C. Type AVB) Switchboard Wire have been used by switchboard manu facturers, power stations and industrial plants since we originated and patented the A.V.C. type. Fine appearance is assured complet ed boards because it can be bent at tight angles without cracking the braid. Rockbestos A.V.C. Switchboard Wires have a maximum operating temperature of 90C (194F) and are listed by the Underwriters' Laboratories. They comply with the NEMA Small Wiring for Switchboards Standard and are approved by Factory Mutual Lab oratories, switchboard manufacturers and power companies. See Page 42 for Rockbestos synthetic and asbestos insulated switch board wires, N.E.C. Type TA constructions. MOTOR LEADS ^MiJl motors and other heavy duty stationary and traction types use Rockbestos A.V.C. Motor Lead and Apparatus Cable for pro tection against conductor-heating overloads and high ambient temperatures. This cable retains its flexibility indefinitely because it won't dry out with heat or age, won't rot or bloom from contan with oil or grease and won't burn or carry flame. These per formance-protecting characteristics make it ideal for motor wiring in steel trulls, generating stations, al! types of coal mining equip ment, industrial plants--and numerous electrical apparatus app lications. RBB 00478 7 POWER CABLE NEC TYPE AVA--ROCKBESTOS A.V.C. 600 TO 5,000 VOLT RATINGS SINGLE CONDUCTOR--STRANDED APPLICATIONS Rockbestos A.V.C (N.E.C Type AVA) Power Cables are designed to operate at voltages from 600 to 5000 volts. They are especially recommended for circuits ex posed to severe operating conditions in power stations, steel mills, refineries, tanneries, smelters, etc. and for apparatus which operates under high ambient temper atures. On the higher voltage rated cables, suitable copper shielding tapes may be specified to eliminate effects of corona on the primary dielectric--the varnished cam bric. Voltage rating of all Rockbestos Hi-1 A.V.C. Power Cables is maximum phase to phase voltage. This applies to either grounded or ungrounded systems. The cables listed in this section have ample moisture resistance for average conditions, but if there is a pos sibility that circuits may be submerged in water for long periods, use lead sheathed constructions in the AVL section of this catalog. The wires and cables in this section are approved National Electrical Code Types, listed by the Underwriters' and fulfill the re quirements of NEMA for Asbestos-Varnished Cambric wires and cables. SPECIFICATIONS Construction 1. Stranded plain copper conductor 2. Felted asbestos 3- Varnished cambric 4. Felted asbestos 5. Asbestos braid Maximum conductor operating temperatures follows: 600 Volt 1000 Volt 2000 Volt 3000 Volt 4000 Volt 5000 Volt 110C 110oC 109C 106C 103C 100C (230F) (230F) (228F) (222F) (2I7F) (212F) Standard finish colors: Blade and white. Authorized Stock item: (600 volt-Table E only) Black. Flexible standings may be specified on alJ construc tions up to 5000 volts. All constructions listed can be covered with lead sheath, armor, or lead sheath and armor, if desired. Interlock ing armor can be furnished to spedal order. RBB 00479 ROCKBESTOS A.V.C. SINGLE CONDUCTOR POWER CABLE TABLE E, 600 VOLTS MAX. OPERATING TEMP. 110C (230F) TABLE H, 5000 VOLTS MAX. OPERATING TEMP. 100C (2t2FJ Size Stranding TABLE E I8AWG *16 14 12 10 8 6 5 4 3 2 i 0 00 000 0000 260.000 CM 300.000 360.000 400.000 450.000 300.000 350.000 600.000 660.000 700.000 760.000 800.000 850.000 900.000 950.000 1.000.000 1.250.000 1,300.000 1.750.000 2.000.000 7/.0152 7/.0192 7/.0242 7/.0305 7/.0385 77,0486 77.0612 7/.0668 77.0772 7/.0867 7/.0974 19/.0664 19/.0743 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0973 37/.1040 37/.I103 37/.H62 61/.Q950 61/.0992 61/.1032 61/.1071 61/.1109 61/.1145 61/.1180 61/.1215 61/.1248 61/.1280 917.1172 91/.1284 127/.1174 127/.1255 TABLE H Bare Diem. Inches .046 .058 ,073 .092 .116 .146 .184 306 .232 .260 .292 .332 .373 ,419 .470 .328 .375 .630 .681 .728 .772 .313 .855 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 1.289 1.412 1.526 1.632 Nominal Thickness -- Mils 1st Felted Wall VC Insert 2nd Pelted Asbestos Wall Braid "Nominal Finished Diameter 600 VOLTS 10 30 13 40 .235 10 30 15 40 *250 10 30 15 40 .265 10 30 15 40 .283 10 30 13 40 .310 10 30 15 45 .350 15 30 20 45 .405 15 30 20 45 -430 15 30 20 45 .453 15 30 20 43 .480 15 30 20 45 .515 20 30 30 45 .383 20 30 30 45 .625 20 30 30 45 .670 20 30 30 45 .720 20 30 30 45 .780 25 40 40 45 .875 25 40 40 43 .930 25 40 40 43 .983 23 40 40 45 1.030 25 40 40 45 1.073 23 40 40 45 1.113 30 4Q 40 46 1.165 30 40 40 45 1.205 30 40 40 45 1.240 30 40 40 45 1.275 30 40 40 45 1.310 30 40 40 45 1-345 30 40 40 45 1.375 30 40 40 45 1.405 30 40 40 45 1.435 30 40 40 43 1.465 30 50 50 45 1.640 30 50 50 45 1.765 50 50 50 45 1.880 30 30 50 45 1.985 5000 VOLTS Approx. Net Wgt. in Lbs. per 1000' 30 35 45 53 70 95 140 165 200 240 285 370 450 545 663 813 985 1155 1325 1490 1660 1825 2003 2175 2340 2505 2675 2835 3000 3165 3330 3490 4375 5155 6030 6760 tStmdard Shipping Length Feet Approx. Shipping Weight per 1000' TYPE 500'C 500' C 500' C 500' C 500'C 500'C 500'R 500 R 500'R 500' R 500' R 500'R 500'R 500'R 500'R 500'R 500'R 500'R 500'R 500'R 500' R 500'R 500 R 500 R 500'R 500 R 500'R 500'R 500' R 500'R 500' R 500' R 500' R 500'R 500' R 500'R AVA 37 43 56 68 87 118 175 206 250 300 356 462 562 681 831' 1018 1231 1443 1656 1862 2075 2281 2506 2718 2925 3131 3343 3543 3750 3956 4162 4362 5468 6443 7537 8450 TYPE AVA 10 AWG 8 6 5 4 3 2 t 0 00 000 0000 250.000 CM 300.000 330,000 400.000 450.000 500.000 550.000 600.000 650.000 700.000 750.000 800.000 850.000 900.000 950.000 1.000.000 7/.0385 7/.0486 7/.06I2 7/.0688 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/0822 37/.09GO 37/.0973 37/.1040 37/.1J03 37/.1162 61/.0950 61/.0992 61/.1032 61/.1071 61/.! 109 61/,1145 61/.U80 61/.1215 61/.1248 61/.1280 .116 .146 .184 .206 .232 .260 .292 .332 .373 .419 .470 .528 .575 .630 .681 .728 .772 .813 .855 .893 -929 .964 .998 1.031 1.062 1.093 1.123 1.152 35 15 15 15 15 15 15 20 20 20 20 20 25 25 25 25 25 25 30 30 30 30 30 30 30 30 30 30 120 120 120 320 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 Finiihed diameter* given Above ire average. A tolerittce of plus or oiau* 25 25 25 25 25 25 25 30 30 30 30 30 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 . 40 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 .530 .560 .595 .620 .645 .670 .705 .765 .805 .850 .900 .960 1.035 1.090 1.145 1.190 1.235 1.275 1.325 1.365 1.400 1.435 1.470 1.505 1.535 1.565 1.595 1.625 330 190 230 260 295 345 395 490 555 670 795 955 1120 1300 1480 1660 1825 2010 2185 2360 2530 2700 2870 3040 3210 3360 3530 3720 500'R 500'R 500' R 500' R 500' R 500' R 500'R 500'R 500' R 500'R 500' R 500' R ' 500'R 500' R 500' R 500' R 500'R 500' R 500' R 500' R 500'R 500' R 500' R 500' R 500' R 500' R 500' R 500' R it neeeuiry due to variation in proem of manufacture. B---Reel* 187 237 287 325 368 431 493 612 693 837 993 1193 1400 1623 1850 2075 2281 2512 2731 2950 3162 3375 3587 3800 4012 4200 4412 4650 RBB 00480 9 ROCKBESTOS A.V.C. 600 VOLT CONTROL CABLE TYPE AVA--ROCKBESTOS A.V.C. MAXIMUM OPERATING TEMPERATURE: IIO^C (230F) 7 S4 1 I1 APPLICATIONS Modified in design from our Soaking Pit Cable for cover door control wiring which must withstand the intense heat of red-hot ingots when adjacent covers are off, this A. V. C control cable has proven resistance to high temperatures. This cable finds its use in steel mills, power stations, boiler rooms, automotive, ceramic and glass plants or other indus tries in which control and signal circuits or control appara tus ate exposed to heat or fire hazard. It is especially recom mended for use in circuits and apparatus in metal making mills, boiler rooms, and power plants as it is highly resistant to heat, corrosive fumes, oil, grease and flame and has ample moisture resistance for installation either open or in conduit. Under exposure to flame this cable will maintain vital control and alarm system circuits for longer periods than other types of insulated cables. SPECIFICATIONS 1. Tinned copper conductor 5. Color coded cotton braids 2. Felted asbestos 6. Cable tape }. Varnished cambric 7. Asbestos braid 4. Felted asbestos This cable is NEMA TYPE AVA with a maximum operat ing temperature of U0C (230F). Conductors The standard standings furnished on these Rockbestos A.V.C. Control Cables is 19/22 (No. 9 A.W.G.) and 19/25 (No. 12 A.W.G.) but any desired stranding can be furnished to order and cabled into any required number of conductors. Insulation The insulation of the individual conductors is the same type as that on the power cables described on the previous pages with the exception of the outer braid which is a color coded cotton braid to obtain circuit identification. When furnished fot single conductor use asbesros braid replaces cotton braid. Impregnated felted asbestos walls seal the varnished cambric from heat, flame and oxidation. Moistureproof tape is wrapped over the cabled conductors and the outer covering of tough, braided asbestos yarn is finished with heat, flame and moisture resisting compounds. Coding The individual wires are braided in colors according to the NEMA standard color code for multi-conductor cable, which is reproduced below. Special color combinations can be furnished to specification. Lead or Armor Coveting These cables may be made up with either lead sheath, armor, or lead sheath and armor covering. Synthetic sheathing is optional also where temperatures permit. Finish The standard finish of the outer braided asbestos jacket is a black, flame, heat and moisture resisting compound. NEMA STANDARD COLOR CODE FOR MULTI-CONDUCTOR CONTROL CABLE Conductors i 2 4 5 6 Base Color Black White Red Green Orange Blue Conductors 7 8 9 10 11 12 13 Bue Color White Red Green Orange Blue Black Red Tracer Black Black Black Black Black White White Conductors 14 15 16 17 18 19 Base Color Green Blue Black White Orange Blue Tracer White White Red Red Red Red 0 10 RBB 00481 < 600 VOLT CONTROL CABLE TYPE AVA--ROCKBESTOS A.V.C Nominal sizes--9 and 12 AWG 1-19 Conductors (See Opposite Page for General Information} Standard conductor sties are AWG No. 9-19/22 and No. 12-19/25 tinned copper, insulated with a 10 mil wall of felted and impregnated asbestos, 30 mil wail varnished cam bric insert, another 15 mil wall of felted asbestos and a cotton braid colored according to the NEMA Control Cable Color Code for Multi-Conductor Cables, listed on the oppo site page. The individual conductors are then cabled with jute fillets where necessary, a layer of cable tape is applied and finally an asbestos braid finished with black, flame, heat and moisture resisting compound. The standard make-up on two conductor construction is to cable the conductors with fillers to make round, but it can also be furnished in parallel construction. Parallel must be specified if desired. Lead sheath, armor, lead sheath and armor or synthetic sheathing can be substituted instead of asbestos braid. Spec ify preference. These Rockbestos A.V.C. control cables can also be made up with No. 14, 16 and IS A.W.G. conductors. TABLE MD (AWG No. 12.19/25) Number of Conductors Stranding Bare Ditm. Indies 600 VOLTS Braid Thickness Finished Diem. Inches Nominal Approx. NetWgt. in Lbs. per 1000' I 1 TYPE AVA tSundvd Shipping Length Feet Approx. Shipping Weight per 1000' **i ***2 5 4 5 6 .1 8 9 10 n 12 13 14 15 16 17 18 19 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 19/25 .090 .090 .090 .090 .090.090 .090 .090 ,090 .090 .090 .090 .090 .090 .090 .090 .090 .090 .090 40 .280 52 45 -545 145 45 .585 180 45 .643 230 45 .710 260 45 .780 *05 45 .780 330 45 .830 380 45 .920 435 45 1.000 470 45 1,000 495 45 1.055 335 45 1.065 580 45 1.095 620 45 1.135 670 45 1.160 705 45 1.205 753 45 1.230 790 45 1.230 815 500'R 500'R 500'R 500' R 500' R 500'R 500'R 500'R 500'R 500' R 500' R 500'R 500' R 500'R 300'R 500'R 500' R 500' R 500' R 63 181 225 228 525 381 413 475 544 588 619 669 725 775 838 881 944 988 1019 TABLE MT (awg no. 9-19/22) 600 VOLTS TYPE AVA **! *2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 19/22 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 .127 40 .320 80 45 .630 215 45 .670 275 45 .740 340 43 .820 395 45 .900 475 45 .900 535 45 .985 590 45 1-070 45 1.160 45 1.160 45 1.200 670 735 795 845 45 1.235 915 43 1.275 970 45 1.320 1040 45 1.350 1103 45 1.405 1180 45 1.430 1245 45 1.430 1310 500J R 500'R 500'R 500' R 500' R 500' R 500'R 500' R 500' R 300' R 300' R 500'R 500'R 500' R 500' R 500' R 500'R 500' R 500' R 100 269 344 425 494 594 669 738 838 919 994 1056 1144 1213 1300 1381 1475 1556 1638 "Finished diameters liven above are average. A tolerance of plus or minus 5% is necessary due to variation in process of manufacture. +R--Reels "Single conductor fits no cotton braid. Asbestos braid i* applied directly over insulation. ***Can be fumitbed either parallel or cabled with filters to make round. Specify which- RBB 00482 IT ROCKBESTOS A.V.C. LIGHTING WIRE NEC TYPE AVA--ROCKBESTOS A.V.C 600 VOLT SOLID CONDUCTOR MAXIMUM OPERATING TEMP. 110C (230FI Sizes 18-8 JJP2IES Sites 64/0 APPLICATIONS This wire is recommended for lighting and control circuits in boiler rooms, steel mills, steam tunnels, power, chemical and food processing plants. Also around furnaces, ovens, glass lehrs, forging presses, tenter frames, soaking pits--and in locomotives, resistors, cranes, steam tables, etc. for circuits exposed to heat. You can safely use this lighting wire either open wired ot in conduit, ducts or raceways which are exposed to heat and moisture, corrosive fumes, grease, oil or fire hazard. It is also used in electrical apparatus for panel and control wiring to insuie performance under severe operating conditions. This construction permits continuous operation under tempera tures ranging up to a maximum of 230F. It has ample moisture resistance for average conditions, but if there is a possibility that circuits may be submerged for long periods use Table CL, Rockbestos A.V.C (N.E.C. Type AVL) 600 volt lead sheathed lighting wire on page 14. SPECIFICATION Construction--Sizes 6-4/0 1. Solid Plain Copper Conductor 2. Felted Asbestos 3. Varnished Cambric 4. Felted Asbestos 3. Asbestos Braid National Electrical Code Type AVA--listed by Underwrit, ers' Laboratories, maximum conductor operating temperature U0C(230F). 6^ Construction--Sizes 18-8 1. Solid Plain Copper Conductor ) Varnished Cambric 4. Felted Asbestos 3- Asbestos Btaid National Electrical Code Type AVA--listed bv Underwrtf ers' Laboratories, maximum conductor operating temperate^ I10C (230F). 6* Standard finish colors: Black and white. Authorized stock items: Black, (white also in sizes. Nos. 10 12 and 14.) ' TABLE C Size 18 AWG IS 14 12 10 1 s! 4: 5| 1i 3; 2j 1, 0 00 000 0000 Bare Diim. Inches .040 .051 .064 .081 .102 .128 .162 -182 -204 .229 .258 .289 .325 .365 .410 .460 1st Felted Wall 15 15 15 15 15 20 | 20 i 20 ! 20 J 20 600 VOLTS Nominal Thickness -- Mils VC Insert 30 30 30 30 30 30 30 30 30 50 30 50 30 50 30 30 2nd Felted Wail 20 i 20 20 l 20 ! 20 i 20 r 20 1 20 j1 "20 i; 3200 I 30 ; 30 ' 30 : 30 l ; : : !i Asbestos Braid 40 40 40 40 40 40 43 65 4455 45 45 45 45 45 45 Nominal Finished Diasn. Inches .220 .235 .245 .265 .285 .310 .385 .405 .425 .450 .480 .540 .575 | .615 | .660 ! .710 Approx. Net Wgi. in Lbs. per 1000' 28 53 40 50 65 89 135 160 190 230 275 350 430 525 640 785 TYPE AVA tStandard Shipping Length Feet 500' C 500'C 500'C 500' C 500' C 500' C 500' R 500' R 500'R 500' R 500'R 500'R 500' R 500'R 500'R 500' R Approx. Shipping Weight per tool/ 35 41 50 62 SI 111 168 200 337 287 343 437 537 656 800 981 'Ncrh'?.rtdJrn'N'Jrmn" IImric.Y cid't"''' * ,0,mn" `,lu` flt mi,"" S* " n",7 4 eatittioe process of nsoofinuie. tC-Coils, R-ttssls 12 RBB 00483 ROCKBESTOS A.V.C. 600 VOLT FLEXIBLE CONDUCTOR MOTOR LEAD and APPARATUS CABLE NEC TYPE AVA--ROCKBESTOS A.V.C. MAXIMUM OPERATING TEMP. 110C (230 F) 0 APPLICATION This cable was designed and developed to meet the demand for greater resistance to conductor-heating overloads, high ambient temperatures, other destructive conditions and fire hazard. It is widely used in electrical apparatus for coil con nections and motor leads on either AC or DC. Because of its A.V.C. construction it is ideal for wiring transformers, re sistors, hoists, cranes, traction and mill motors which must function under exposure to heat and moisture, corrosive fumes, grease or oil. SPECIFICATIONS Construction 1. Flexible tinned copper conductor 2. Felted asbestos 3. Varnished cambric 4. Felted asbestos 3. Asbestos braid This cable is National Electrical Code Type AVA, maximum operating temperature 110C (230F) listed by the Under writers' Laboratories. Rockbestos Motor Lead and Apparatus Cable is available in voltage ratings up to 3000 volts and may be furnished with extra-flexible conductors. Standard finish colors: Black and white. Authorized stock items: Black. TABLE L 600 VOLTS TYPE AVA > Size Stranding Bare Diais. Inches N'ominal Thiclcae--Mill 1st Felted Wall VC 2nd Felted Asbestos Insert - Wall Braid ^Nominal I Approx. Finished Net Wgt. Diun. ' in Lbs. Inches f per 1000' tStandard Shipping Length Feet Approx. Shipping Weight per 1000' **18 AWG **16 14 12 16/.010 267.010 417.010 657.010 .045 .059 .075 .095 10 10 10 10 30 30 30 30 15 40 .235 15 15 40 40 .250 .265 15 40 .285 30 500' C 35 500' C 45 500'C 55 500'C 36 41 51 61 10 I04/.010 .120 10 8 1337.0111 .167 10 6 133/.Q140 ,210 15 5 1337.0158 .237 15 30 30 30 30 15 15 20 40 45 45 -310 .3?0 -430 75 500' C 81 100 500' C 106 150 500' R 187 20 45 .460 175 500'R 218 4 133/.0177 .266 15 3 1337.0199 .299 15 2 1337.0223 .335 15 1 2597.0180 -378 20 30 30 30 30 20 20 20 45 45 45 .490 .520 ! .555 | 210 255 305 500' R 500' R 500' R 262 318 381 30 45 .630 i 385 500'R 481 0 00 000 0000 2597.0202 2597.0227 2597.0255 2597.0286 .424 ,477 -336 .601 20 20 20 20 30 30 30 30 30 .675 470 500'R 587 30 .730 570 500' R 712 30 45 .790 700 500' R 875 30 45 .855 850 500'R 1062 250.000 04 300.000 350.000 400.000 427/.0242 4277.0265 4277.0286 4277.0306 .653 .716 .772 .826 25 25 25 25 40 40 40 40 40 40 45 .955 1030 500' R 1287 1.020 1205 500'R 1506 40 1.075 1380 500'R 1725 40 45 1.130 1555 500'R 1943 450.000 500,000 550,000 600.000 4277.0323 4277.0342 4277.0359 4277.0375 .878 .923 .969 1.013 25 25 30 30 40 40 40 40 40 45 1.180 1740 500" R 2175 40 45 1.225 1905 500' R 2381 40 45 1.280 2100 500'R 2625 40 45 1.325 2305 500' R 2881 650.000 700.000 750.000 800.000 4277.0390 4277.0405 427/.0419 4277.0433 1.033 1.094 1.131 1.169 30 30 30 30 40 40 40 40 40 45 1.365 2440 500' R 3050 40 1.405 2570 500'R 3212 40 45 1.445 2780 500'R 3475 40 45 1.480 2855 500'R 3568 900.000 1.000.000 4277.0459 4277.0484 1.239 1-307 30 30 40 40 40 1.550 3223 500' R 4028 40 45 1,620 3590 500' R 4487 KgUM dil.mrrm *t.tn jteor* an iwap. Not luted in National Electrical Code. A tolerance ef piM or mimu S% is necessity due to variation in process of manufacture. tC--Coils, R--Reels RBB 00484 13 LEAD SHEATHED POWER CABLE NEC TYPE AVI--ROCKBESTOS A.V.C. 600 TO 5,000 VOLT RATINGS i SINGLE CONDUCTOR--STRANDED ja * APPLICATIONS These Rockbestos Lead Sheathed Power Cables are used for Power and Lighting Circuits exposed to high temperatures in combination with excessive condensation or complete submersion. Use this cable where a conduit run is exposed to widely vary ing conditions throughout its length, particularly in power stations located on tidewater where certain ducts are some times flooded but where another section of the same circuit is exposed to high temperatures. Also around ash pits where the wetting down of die ashes results in abnormal conden sation. The Cables listed in this section ail conform to NEMA Standards for Asbestos Varnished Cambric wires and cables with lead sheath. The lead sheath has no effect on the ability of these cables to withstand high temperatures but affords protection against abnormal condensation or complete submersion. SPECIFICATIONS Construction 1. Stranded plain copper conductor 2. Felted Asbestos 5- Varnished cambric 4. Felted asbestos 5. Lead sheath This cable is National Electrical Code Type AVL, listed by the Underwriters' Laboratories and is available in sizes up to 2,000,000 CM. Maximum operating temperatures are as follows: 600 Volt no^c (2jofi 1000 Volt 1I0C (2J0F) 2000 Volt 109C (22SF) 3000 Volt 106C (222F) 4000 Volt 103C (217F) 5000 Volt 100C (212F) These cables are our Standard Power Cable constructions with a lead sheath instead of an asbestos braid. LIGHTING WIRE LEAD SHEATHED (SOLID) MAXIMUM OPERATING TEMP: nOC [230oF) 1*9 !. SOLID PLAIN COFR CONDUCTOR 2, FELTED A5S6STOS 49 3 VARNISHED CaM#RJC 4. FELTED ASRESTOS 5. LEAD SKEATH ! Bare Size | Diam. Inches TABLE CL Nominal Thickness - Mils | 1st Felled } VC Wall Insert 2nd Felted : Wall ; Lead Sheath Thickness Inches 600 VOLTS Nomina! 1 Finished Diam. j Inches Approx. Net Wgt. in Lbs. per 1000- ^Standard Shipping Length Feet i ; Approx. Shipping Weight per 1000' TYPE AVL 18 AWC i .040 30 25 ; 3/64 .245 1 170 500' R ! 212 .051 30 25 ! 3/64 .255 ISO 500' R 1 225 4 .064 30 25 i 3/64 .270 200 500' R ' 250 1: .081 10 .102 30 3/64 .285 220 500' R 275 50 25 ! 3/64 -310 ! 250 500' R 312 ?6 .128 ; .162 15 30 30 25 ; 3/64 25 - 3/64 335 : .400 i 2S5 5S0 500' R 300' R 356 4-5 5 j .182 15 30 25 : 3/64 .420 1 420 500' R 525 4 1 .204 15 30 23 ' 3/64 .440 ! 465 500'R 581 .229 15 30 25 : 3/64 .465 : 520 500' R 650 - j .258 l -289 15 20 30 30 25 : 3/64 30 4/64 .495 i .571 i 5S5 830 500' R 500' R 731 1037 o .525 00 ' ,565 20 20 30 50 30 : 4/64 30 4/64 .610 1 ,650 ' 940 1070 500' R 500'R 1175 1337 000 : .410 20 30 50 . 4/64 .695 ; 1225 500' R 1331 0000 j .460 20 30 30 : 4/64 .745 1415 500' R 1768 Finished diameter! give ib** are average. A tolerance of p|uj or mimjJ 5^ ij necettary due to vartatton in proccis of manufacture. + R--Reel* Nor luted in National Electrical Code. 14 RBB 00485 ROCKBESTOS A.V.C. LEAD SHEATHED SINGLE CONDUCTOR POWER CABLE max. operating temp. 103C I217F) max. operating temp. 100C Bare Nominal Thickness -- Mil* Lead 'Nominal Approx, 1 tStandard Approx. Sheath Finished Net Wgt. Shipping Snipping Diem. 1st Felted VC 2nd Felted Thickness Diam. in Lbs. i Length Weight Sue Stranding laches Wall Insert Wall Inches Inches per 1000' 1 Feet per 1000' TABLE EL 600 VOLTS TYPE AVL 18 AWG 7/.0152 .046 10 30 25 3/64 .270 195 1 300' R 243 16 7/.0192 .058 10 30 25 3/64 .285 205 1 500' R 256 14 7/.0242 .073 10 30 23 3/64 .300 225 1 500' R 281 12 7/.0305 .092 10 30 25 3/64 .320 250 500' R 312 10 7/.0383 .116 10 30 25 3/64 .340 275 500' R 343 8 7/.0486 .146 10 30 25 3/64 370 325 500' R 406 6 7/.0612 .184 15 30 25 3/64 .420 395 500'R 493 3 7/.06B8 .206 13 30 25 3/64 .440 445 500'R 556 4 7/.0772 .232 15 30 25 3/64 .470 490 500' R 612 3 7/.0S67 .260 t5 30 25 3/64 .495 550 500'R 687 2 7/.0974 .292 15 30 25 4/64 .560 745 500'R 931 1 I9/.0664 .352 20 30 30 4/64 .620 875 500'R 1093 0 19/.0745 .373 20 30 30 4/64 .660 1000 500'R 1230 00 19/.0837 .419 20 30 30 4/64 *705 1125 500' R 1406 000 19/.0940 .470 20 30 30 4/64 .760 1290 500' R 1612 0000 19/.1055 .528 20 30 30 4/64 .815 1490 500'R 1862 250,000 CM 37/.0822 .575 25 40 40 5/64 .945 1983 500'R 2481 300.000 37/.0900 .630 25 40 40 3/64 1.000 2240 500'R 2800 350,000 37/.0973 .681 25 40 40 5/64 1.030 2445 500'R 3036 400.000 37/.1040 .728 25 40 40 5/64 1.093 2665 500' R 3331 450.000 37/.1103 ,772 25 40 40 3/64 1.140 2925 500'R 3656 500.000 37/.1162 .813 25 40 40 3/64 1.180 . 3095 >00'R 3868 550.000 61/.0950 .855 30 40 40 6/64 1.263 3780 500 R 4723 600,000 61/.0992 .893 30 40 40 6/64 1.300 3870 500'R 4837 650.000 61/. 1032 .929 30 40 40 6/64 1.340 4130 300' R 5162 700.000 61/.1071 .964 30 40 40 6/64 1.375 4250 500'R 5312 750.000 61/.1I09 .998 30 40 40 6/64 1.405 4515 500'R 5643 800.000 61/.U45 1,031 30 40 40 6/64 1.440 4720 300'R >900 850.000 61/.1180 1.062 30 40 40 6/64 1.470 5030 500'R 6287 a 900.000 61/.1215 1.093 30 40 40 6/64 1,500 5140 500'R 6425 950.000 61/.1248 1.123 30 40 40 6/64 1.530 3395 500'R 6743 1,000,000 61/.1280 1.152 30 40 40 6/64 1.560 5540 500' R 6925 1,250.000 91/.1I72 1.289 30 50 50 7/64 1.770 7135 300' R 8918 1. $00,000 91/.1284 1.412 30 50 50 7/64 1.890 8140 500'R . 10173 1.750.000 127/,1174 1.526 30 30 50 7/64 2.005 9210 >00'R 11512 2.000.000 127/.1255 1.632 30 50 50 7/64 2,110 10120 500 R 12650 TABLE HL 5000 VOLTS TYPE AVL 10 AWG 7/.0385 .116 15 120 25 4/64 .565 <515 500' R 768 8 7/.0486 .146 15 120 25 4/64 .595 674 500' R 842 6 7/.06I2 .184 15 120 25 4/64 .630 750 500' R 937 5 7/.0688 .206 15 120 25 4/64 .655 820 500' R 1025 4 3 7/.0772 7/.OS67 .232 .260 15 15 120 25 4/64 .680 860 500' R 1073 120 25 4/64 .705 930 500'R 1162 2 7/.0974 .292 15 120 25 4/64 .740 1010 500' R 1262 1 19/.0664 .332 20 120 30 4/64 .800 1150 500'R 1437 0 00 000 19/.0745 19/.0837 19/.0940 .373 .419 .470 20 20 20 120 120 120 30 3/64 .870 1430 500' R 1850 30 3/64 .915 1645 500' R 2056 30 5/64 .970 1830 300' R 2287 0000 19/.1055 .528 20 120 30 5/64 1.025 2055 500'R 2568 250.000 CM 300.000 350,000 400.000 37/.0822 37/.0900 37/.0973 37/.1040 .575 .630 .681 .728 25 25 25 25 120 40 5/64 1,105 2305 500' R 2881 120 40 3/64 1.160 2544 500'R 3180 120 40 6/64 1.240 3095 500'R 3868 120 40 6/64 1.290 3335 500'R 4168 450.000 500.000 550.000 600,000 37/. 1103 37/.1162 61/.0930 61/.0992 .772 .813 .855 .893 25 25 30 30 120 120 120 120 40 6/64 40 6/64 40 - 6/64 40 6/64 1.330 1.375 1.425 1.465 3365 3800 4040 4280 500' R 500' R 500' R 500'R 4456 4750 5030 5350 650.000 700.000 750.000 800,000 61/.1032 6I/.1071 61/.II09 61/.1145 .929 .964 .998 1.031 30 30 30 30 120 120 120 120 40 6/64 t.500 4495 500' R 5618 40 40 6/64 6/64 1.535 1.570 4715 4930 500' R 500' R 3893 6162 40 6/64 1.600 5145 500'R 6431 850.000 900,000 61/. 1180 61/.1215 1.062 1.093 30 30 120 120 40 40 6/64 6/64 1.630 1.665 5398 5370 500' R 6747 6962 9 950.000 61/.1248 1.123 30 120 40 7/64 1.725 6234 7792 1.000.000 61/. 1280 1.152 30 120 40 7/64 1.753 6430 500' R 8037 * Finished diunnen |ivtft above are average, A tolerance of plus or minus i% it necessary due to variation in process of manufacture. tR--Red* RBB 00486 I SPECIAL CONSTRUCTIONS FOR ROCKBESTOS POWER AND CONTROL CABLES This Rockbestos A.V.C. Control Cable illustrated is one of the many multi conductor cables designed to meet specific requirements in control and power circuits. They are made up as shown or with either lead sheath or armor only as specified and in ratings ranging from 600 to 5000 volts. (Synthetic sheath ings may also be specified for controi cables where temperatures permit.) This type of cable not only protects operation of circuits exposed to heat and moisture and other severe operating conditions, but also increases the flexi bility of wiring systems and makes circuits more easily accessible. The felted asbestos insulation, impregnated with heat, flame and moisture resisting compounds, withstands high temperatures, corrosive fumes, aging and conductor-heating overloads. The lead sheath protects it from excessive condensation resulting from heating and cooling cycles and complete sub mersion. The spiral bronze armor eliminates the need for conduit, an impor tant consideration in capacity expansion programs, as the cable can be run in troughs, up vertical risers or over and around obstructions. Its flame and heat resistant structure will also maintain vital alarm and control system cir1 cuits for Longer periods under exposure to flame than other conventional , (ypesThe cable illustrated on this page is a special construction which is typical of many `'specials'' designed by Rodcbestos to meet severe or unusual operating conditions. Its construction consists of: Conduit saving bron2e armor covering for protection against abrasion. Impregnated jute serve to cushion the armor and to protea the lead sheath from mechanical damage. Lead sheathing for proteaion against immersion or excessive condensation. Friction tape to bind the cabled conductors securely together to maintain the lay. INDIVIDUAL CONDUCTORS Coded individual cotton braided conductors for easy circuit identification. Felted asbestos beneath the cotton braid impregnated with heat, flame and moisture resistant compounds. Varnished cambric for high dielectric strength and added moisture resistance Inner wall of felted asbestos to complete the A.V.C. construction serving as a baffle between the varnished cambric and heated conductors. 16 RBB 00487 ROCKBESTOS A.V.C. 600 VOLT SWITCHBOARD WIRES NEC TYPE AVB--ROCKBESTOS A.V.C. TABLE 8--SOLID TABU BS--STRANDED. MAXIMUM OPERATING TEMP. 90C (194 FI 1( 4 I. SOLID O* ST**N0fD TINNED COFFEE CONDl/CTOE 2. VARNISHED CANIt1C 2. KITED ASIESTOS 4. FUMEFEOOF COTTON UAID FOR SWITCHBOARDS, RADIO AND TELEVISION TRANSMITTERS, MOTOR DRIVEN RHEOSTATS, CONTROL PANELS FOR MOTOR STARTERS, ELEVATORS, FIRE DOORS. CRANES, INDUCTION HEATING APPARATUS, OIL BURNING BOILER UNITS, ETC Standard finish colors; Gray and Black. Authorized stock items: Gray. TABLE B (Solid) Size 18AWG 16 14 12 10 8 6 k5 f4 r3 "2 1 0 00 000 0000 Bare Dias. Inches .046 .051 .064 .081 .102 .128 .162 .182 .204 .229 .258 .289 .325 .365 .410 .460 600 VOLTS Nominal Thickness -- Mils VC ! Felted | Will Cotton Bnid 30 ! 20 30 I 20 30 20 30 1 20 30 ] 20 30 20 40 ! 30 40 | 30 40 ! 30 40 , 30 40 30 40 ! ' 40 40 40 40 ; 40 40 1 40 40 j 40 16 16 16 16 17 17 17 17 17 20 20 20 20 20 20 20 Nominal Finished Dims. Inches .175 .185 .200 .220 .240 .270 .340 .360 .380 .415 .445 .495 .530 -570 .615 .665 Approx. Net Wgt in Lbs. per 1000' 20 25 30 40 55 80 125 150 175 215 260 330 405 495 610 750 TYPE AVB | tStandard j Shipping ; Length ! Feet Approx. Shipping Weight per 1000' | 500'C 500'C ! 500'c ! 500' C 1 500' C i 500'C 1 500' R ! 500'R i 500'R : 500'R 1 500'R I 500' R ' 500'R i 500'R i 500' R ' 500' R 25 31 36 46 61 86 156 187 218 268 325 412 506 618 762 937 TABLE BS (Stranded! 600 VOLTS TYPE AVB i Bare Size j Stranding Diaro. Inches Nominal Thickness --Mils vc Felted Wall Cotton Braid ^Nominal Finished Diem, Inches Approx. Net Wgt, in Lbs. per 1000' tStandard Shipping Length Feet Approx. Shipping Weight per 1000' 16AWG 14 12 10 8 6 5 4 23 I 0 00 000 0000 7/.0192 : 7/.0242 : 7/.0305 7/.0385 7/.0486 ; 7A0612 7/.0688 7/.0772 7A0S67 7/.0974 19A0664 19/.0745 . 19/.08 37 19/.0940 : 19/.1055 .058 .073 .092 .126 .146 .184 .206 -232 .260 .292 .332 .573 .419 .470 .528 30 30 30 30 30 40 40 40 40 40 40 40 40 40 40 20 16 .190 20 16 .205 20 16 .225 20 17 .250 25 500'C 31 35 500' C 41 43 500'C 51 60 500'C 66 20 17 .280 80 500'C 86 30 17 .360 130 500'R 162 30 17 .380 130 500' R 187 30 20 .415 185 500'R 231 30 20 .440 225 500' R 2S1 30 20 .475 280 500' R 350 40 20 .535 345 500'R 431 40 20 .575 420 500' R 525 40 20 ,620 515 500'R 643 40 20 .670 630 500' R 787 40 20 .730 780 500' R 975 Finiihtd diimcieri |ivi jbovt >te muj!. A tolerinct of plw Of rainiu S% if ntceuirr due to million ia pineal of minuficcnrc. tC--Coili, R--Reels 17 RBB 00488 ROCKBESTOS A.V.C. 600 VOLT SWITCHBOARD HINGE CABLE NEC TYPE AVB--ROCKBESTOS A.V.C. MAXIMUM OPERATING TEMP. 90C tl94FI ], STRANDED TINNeo COWR CONDUCTOR PELTED ASBESTOS 3, VARNISHED CAMltlC . PELTED a4105 5. FLAMERIOOP COnON 'Uld FOR HINGE AND JUMPER CONNECTIONS ON SWINGING INSTRUMENT t AND SYNCHRONIZING METER PANELS, MOTOR LEADS AND APPLICA TIONS SUCH AS LISTED UNDER TABLES B AND BS. As a companion wire to Rodcbestos Switchboard Wire we offer this heat, flame and moisture resisting flexible Hinge Cable. Designed primarily for hinge or jumper connections on swinging instrument and synchronizing meter panels, etc., it is also used in various applications in electrical appara tus to maintain dependable performance. It may also be used for conduit wiring where conditions are not severe enough to require an asbestos braid. Standard construction employs a flexible stranded, tinned copper conductor, insulated with a felted wall of asbestos, an insert of varnished cambric tape, another wall of felted asbestos, impregnated with flameproof and moisture resisting insulating compounds, and a cotton braid finished with flameproof I compound. Showing application of Rocibeitoi Table The diameters of Rodtbestos Hinge Cable are approximately the same as BH 600 Volt Hinge Cable to ttoinging panel. those of other Rodcbestos Switchboard Wires, and braid finishes are identi cal to assure matching appearance when used on the same board. Rodcbestos A. V. C. Hinge Cable is designated as National Electrical Code Type AVB, has a maximum operating temperature of 90C (194F) and is listed by the Underwriters' Laboratories. It complies with the NEMA Small Wiring for Switchboards Standard and is approved by Factory Mutual Laboratories, switchboard manufacturers and power companies. Standard finish colors: Gray and black. Authorized stock items: Gray. Be sure to specify braid color desired on or der. i TABLE BH 600 VOLTS TYPE AVB Bare Nominal Thickness -- Mils Nominal Approx. 'tStandard Approx. Finished NetWgi. Shipping Shipping Stranding Diam. 1st Felted vc 1 2nd Felted Cotton Diem. in Lbs. Length Weight Size Tinned Inches Wall Insert ! Wail Braid Inches per 1000" Feet per 1000' * 18 AWG *16 14 12 10 S I6/.010 26/.010 41/.010 6 5/.010 104/.010 133/-01II .043 .059 .075 .095 .120 .167 10 10 10 10 10 10 30 1 1} 30 30 i 15 30 ! 13 30 : 15 30 ; i5 16 .190 16 .205 Id .220 17 .240 17 -265 17 .313 25 500' C 31 30 500' C 36 35 500'C 41 45 500' C 51 60 500' C 66 90 500'C 96 *Fmibd diameter* riven above are aveiage. A tolerance of plus or minus S9t is necessary due to variation in procett of manufacture. +C-- **Noc hared in National Electrical Code. eC % 18 RBB 00489 ROCKBESTOS THERMOPLASTIC and ASBESTOS 600 VOLT SWITCHBOARD WIRES AND FLEXIBLE HINGE CABLE National Electrical Code Type TA TABLE XB, SOLID--TABLE XBS, STRANDED TABLE XBH, FLEXIBLE STRANDED HINGE CABLE MAXIMUM OPERATING TEMP. 90C (194 F) < tt > 1. SOLID OR ST1ANDED TINNED COPPER CONDUCTOR 3. THEDMOflASTIC INSULAnOM 3. SILTED ASIESTOS ' FOR SWITCHBOARDS, CONTROL PANELS AND HINGE CONNECTIONS Standard finish colon: Gray and black. Authorized stock items: Gray. TABLE XB (Solid)600 VOLTS'TYPE TA Minimum Nominal Thickness--Mils ^NymiaaJ Approx. Bare Thermoplastic Finished NttWgt Dias. Insulation Fehed Cotton Diun. in Lbs. Size Inches Mils Wall Braid Inches per 1000' * 4. ELAMEFftOOF COTTON IKAIO ^Standard Shipping Length Feet Approx. Shipping Weight per 1000' *18 AWG *16 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 .040 .051 .064 .081 .102 .128 .162 .182 .204 .229 .258 .289 .325 .365 .410 .460 20 20 20 20 20 20 30 30 30 30 30 40 40 40 40 40 20 20 20 20 20 20 25 25 25 25 25 30 30 30 30 30 TABLE XBS (Stranded)600 VOLTS f-------------- Size Stranding Bare Diam. Inches Minimum Thermoplastic Insulation Mils 16 16 16 16 16 17 17 17 17 17 20 20 20 20 20 20 Nam. Thidcnesi -- Mils Felted Wall Cotton Braid .160 .170 .185 .200 .225 .250 .315 .335 .360 .385 .420 .480 .515 .555 .600 .650 `Nominal Finished Diam. Inches 20 25 30 40 55 75 120 145 175 210 260 330 405 495 605 750 Approx. Net Wgt. in Lbs. per 1000' 500'C 500' C 500' C 500'C 500'C 500'C 500' R 500'R 500' R 500'R 500' R 500'R 500'R 500'R 500'R 500' R 26 31 36 46 61 8i 150 181 218 262 325 412 506 618 756 937 TYPE TA fStandard Shipping Length Feet Approx. Shipping Weight per 1000' **18 AWG **16 14 12 10 S 6 5 4 3 2 1 0 00 000 0000 7/.0152 7/.0192 7/.0242 7/.0305 7/.0385 7/.0486 7/.0612 7/.0688 7/.0772 7/.0867 7/-0974 19/.0664 19/.0745 19/.0837 19/.0940 19/. 1055 .046 .058 .07 J .092 .116 .146 .184 .206 .232 .260 .292 .332 -373 .419 .470 .528 20 20 20 20 20 20 30 50 30 30 30 40 40 40 40 40 20 16 .165 20 500' C 26 20 16 .180 25 500' C 31 20 16 .195 32 500'C 38 20 L6 .215 41 500' C 47 20 17 .240 56 500'C 63 20 17 .270 79 500' C 85 25 17 -340 125 500'R 156 25 17 .365 150 500' R 187 25 17 .395 180 500'R 225 25 20 .425 240 500' R 300 25 20 .455 263 500' R 331 30 20 525 345 500' R 431 30 20 .563 420 500'R 525 30 20 .610 515 500'R 643 30 20 .660 635 500' R 793 30 20 .720 780 500' R 975 TABLE XBH (Flexible Stranded) 600 VOLTS TYPE TA **18 AWG *16 14 12 10 8 6 5 4 3 2 1 0 00 000 0000 16/.010 26/.010 41/.010 65/.010 104/.010 I33/.011I 133/0140 133/.0158 133/.0177 133/.0199 133/.0223 259/.0180 259/.0202 259/.0227 259/.0255 259/.0286 .045 .059 .075 .095 .120 .167 .210 .237 .266 .299 .335 -378 .424 .477 .536 .601 20 20 20 20 20 20 30 30 30 30 30 40 40 40 40 40 20 16 .165 20 500' C 25 20 16 ISO 25 500' C 30 20 16 .195 31 500' C }7 20 16 .215 42 500' C 47 20 r .245 5' 500' C 63 20 17 .290 84 500' C 89 25 17 .365 130 500' R 162 25 20 395 160 500' R 200 25 20 .425 190 500' R 237 25 20 .460 230 500'R 287 25 20 .495 280 500' R 350 30 20 .570 360 500' R 450 30 20 .615 435 500' R 543 30 20 .670 535 500' R 668 30 20 .730 660 500' R 825 30 20 .'95 810 500' R 1012 tFiniabcd diameter* grven above are average. A tolerance of pJuj or oian* J% ia neccisanr due to variation in process of manufacture. tC--Coils. R--Reels 'Nor listed in National Electrical Code. RBB 00490 1 ROCKBESTOS ALL-ASBESTOS 600 VOLT RHEOSTAT WIRE National Electrical Cade Typo AIA MAXIMUM OPERATING TEMP. 125C 1257 FI a 1. SOUD PLAIN COfflt CONDUCTOR * 1. KtltD ASMSTOJ 1 nSttSSOS SttMO FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES. INFRA RED DRYERS, OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD. Asbestos rheostat wire was originally produced by putting two or three braids of asbestos yam on the wire and finishing each braid with compound. This had several disadvantagesI For example, its moisture resistance was very low due to the comparatively open covering so that many engineers consid ered that spiced wiring was necessary in order to prevent possible leakage under damp conditions. The labor cost ol doing this type of wiring is high. Another disadvantage--though really more of an annoyance --was that in working with this wire a good deal of the compound flaked o5 and continued to do so after the instil1 iation was completed, spoiling the appearance of an otherI wise nice job. The Rockbestos development of the felted and impregnated wall of asbestos insulation was a distinct improvement. In stead of a relatively open covering on the wire, the asbestos is applied in the form of a homogeneous insulation. The dieiectnc strength is thereby increased. Next, the -impregnat ing compound is an integral parr of the insulating wall, not * painted on after the wall is formed. That means that, through repeated hearing and cooling cycles, the compound can never fall away from the asbestos. The dielectric sttength and mois ture resistance of Rockbestos Rheostat Wire ate, therefore, practically constant. And there is none of the usual Baking when working with Rockbestos Rheostat Wire and Cable, with either white or black braid. Because of its comparatively high moisture resistance Rockbestos Rheostat Wire may be bunch-wired with safety, and it is also recommended for open wiring carrying less than 600 volts which is subject to high temperatures ot totting, corrosive fumes. For a 300 volt construction of the same type refer to page 24. This wire is National Electrical Code Type AIA listed by the Underwriters' Laboratories as Type AIA wire and has a maximum operating temperature 125C (2J7F). Standard finish colors: Black and white. Authorized stock items: Black (white also in sizes nos. 6, 8, 10, 12 and 14. TABLE A Size **18AWC * 16 14 1: 10 $ 6 5 4 3 2 1 0 00 000 0000 ' Bare DUm. Inches .010 .051 .Odd .081 102 .128 .162 .132 .204 .229 .258 .289 .525 .565 .410 .460 600 VOLTS Nominal Thickness--Mils Felted Wail j Asbestos | Braid Noroinal Finished Dtarn. Inches 30 40 30 40 30 40 30 ! 40 30 j 40 30 ! 40 40 40 ! 45 40 ! 41 40 45 40 1 45 60 i 45 60 45 60 45 60 45 60 45 .180 .195 .205 .225 .245 .270 -325 .355 -375 .400 .430 -500 w .575 .620 .670 Appro*. Net Wgt. in Lbs. per 1000' 22 26 ! 32 : 42 ; 56 1 79 115 140 165 205 255 320 395 485 600 745 TYPE AIA tSiandard Shipping Length Feet Approx. Shipping < Weight per 1000' 500' c 500' C 500' C 500' C 500' C 500' C 500' R 500' R 500' R 500' R 500'R 500' R 500'R 500' R 500'R 500'R i j | ' i , 27 32 37 47 61 84 us 175 206 256 318 400 493 606 750 931 Finiihed diameter. given above ate average. A tolerance ot pi01 or minui SSfe i* necestary due 10 variation in proem of manufacture. tC--Corlt. R--Reel. N01 lured in National Elecrrical Code. 20 RBB 00491 ROCKBESTOS ALL-ASBESTOS 600 VOLT POWER and RHEOSTAT CABLE National Electrical Code Type AIA MAXIMUM OPERATING TEMP. 125C (257R 1. ST*AN0ED flAIN COTfK CONBUCtO* 11 rtlttD ASM3TOS 3 3. ASItSTOS MAID FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES, INFRA-RED DRYERS, OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD. This wire is listed by Underwriters' Laboratories as Type AIA wire. Standard finish colors: Black and white. Authorized stock items: Black (white also in sizes nos. 12 and 14). For 300 volt construction refer to page 24, Table RF-300. RockbestoS High Temperature Rheostat Wire, TABLE R Size * * 18 AWG *16 14 12 10 8 6 5 4 3 2 \ 0 00 000 ' 0000 250.000 CM 300.000 350.000 400.000 450.000 500.000 550.000 (500.000 630.000 700.000 750.000 800.000 850.000 900.000 950,000 l.000.000 Stranding 7/.0I52 7/.0192 7/.0242 7/.0305 7/.0585 7/.0486 7/.0612 7/.0688 7/.0772 7/0867 7/.Q974 19/.0664 19/.0745 I9/.0837 19/.0940 19/. 105 5 37/.0822 37/.0900 37/.0973 37/.1040 37/. 1103 37/.1162 61/.0950 61/.0992 61/.1032 61/.1071 61/.1109 6I/.1145 61/.1180 61/.1215 6I/.1248 61/.1280 Bare Diem. Inches .046 .058 .073 .092 .116 .146 .134 .206 .232 .260 .292 .332 .373 .419 .470 .528 .575 .630 .681 .728 .772 .813 .855 .893 .929 .964 .998 1.031 1.062 1.093 1.123 1.152 600 VOLTS Nominal Thickness -- Mils Fehed Wall Asbestos Braid * Nominal Finished Diam. Inches 30 40 30 40 30 40 40 40 40 40 40 40 60 45 60 45 60 45 60 45 60 45 75 45 75 45 75 45 75 45 75 45 90 45 90 45 90 45 90 45 90 45 90 45 105 45 105 45 105 45 105 45 105 45 105 45 105 45 105 45 105 45 105 45 .190 .200 .215 .255 .280 .310 -395 .420 .445 .470 .505 .575 .615 .660 ,710 .770 .845 .900 .955 1.000 1.045 1.085 1.155 1.195 1.230 1.265 1.300 1.335 1.565 1.395 L425 1.455 Approx. NetWgt. in Lbs. per 1000' 22 28 3^ 47 64 90 no 155 185 123 270 345 420 520 635 785 920 1080 1245 1405 1570 1730 1890 2080 2240 2415 2560 2730 2890 3050 3215 3375 TYPE AIA tStandard Shipping Length Feet 500' C 500' C 500' C 500' C 500' C 500' C 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500' R 500'R 500' R 500'R 500'R >00'R 500' R 500'R Approx. Shipping Weight per 1000' |n 33 39 53 69 j 94 1 162 193 1 231 1 281 337 431 525 650 793 981 1150 1330 1556 1756 : 1962 2162 1 2362 2600 2800 3018 3200 3412 3612 3812 4018 4218 Finished diameter* given above are average. A tolerance of plus or minus Not listed in National Electrical Code. is necessary due to variation in process of manufacture. tC-^oils, R--Reels 21 RBB 00492 ROCKBESTOS ALL-ASBESTOS 600 VOLT FLEXIBLE APPARATUS CABLE MAXIMUM OPERATING TEMP. 125C (257F) < I I1 1. FLEXIBLE TINNED COfFIt COWJCTO* 2. FUTCO ASBESTOS ASBESTOS MAiD FOR FLEXIBLE LEADS AND CONNECTIONS OF APPARATUS SUCH AS LISTED UNDER TABLES "A" AND "IT--OVENS. FUR NACES. DRYERS. AUTOMOTIVE BUS IMMERSION HEATER LEADS, BATTERY LEADS AND ENGINE COMPARTMENT WIRING. This cable is recommended wherever flexible leads or con nections must be used in open-wired high temperature installations. Steel mills sometimes use this cable for motor leads exposed to heat where the possibility of a moisture condition is re mote. It will nor deteriorate under constant high ambient temperatures and is highly resistant to corrosive fumes, flame, grease and oil, characteristics which make ft ideal for jumper leads, etc. (For high dielectric strength and moisture resist| ance see Rodcbestos A.V.C. Motor Lead and Apparatus Cable on page 13.) 1 Automotive bus manufacturers and operators use it for en I gine compartment wiring and leads for batteries, crank case and radiator immersion heaters because of its high resistance to heat and flame. (For smaller diameter cable for these applications and diesel locomotive control circuit wiring in quire about special Type ACA engine compartment or con trol cables.) This cable is National Electrical Code Type AIA and is listed by the Underwriters' Laboratories' as Type AIA wire. Maximum operating temperature is 125C (257F). Stand ard finish colors: Black and white. Authorized stock item: Black. This cable can be made up with extra flexible stranded tinned conductor if required. For 300 volt construction refer to page 24, Table RF-300. TABLE RF i 1 t Site i Stranding *18 AWG **16 14 12 10 8 6 5 4 3 1 0 00 000 0000 250.000 CM >00.000 350.000 400.000 450.000 500.000 ' i 1 j : ; i : ! : ! : . , ! . '. j ) | 16/.010 26/.010 41/.010 65/.010 104/.010 133/.01U 133/-0140 133/.0158 133/.0177 133/.OI99 133/.022J 259/.0130 2W.0202 259/.0227 259/.0255 259/.0286 427/.0242 427/.0265 427/.02B6 427/,0306 427/.0325 427/.0342 Bare Diam. laches .045 .059 .07} .095 .120 .167 .210 .237 .266 .299 .335 .378 .424 .477 .536 .601 .653 .716 .772 .826 .878 .923 600 VOLTS Nominal Thickness--Mils Felted Wall Asbestos Braid ^Nominal Finished Diam. Inches 30 40 30 40 30 40 40 40 .185 .200 .215 .255 40 40 40 40 60 45 60 45 .280 .330 .420 .450 60 45 60 45 60 45 75 45 .480 .510 .545 .620 75 45 75 45 7} 45 75 45 .665 .720 .780 .845 90 45 .925 90 45 .990 90 45 1.045 90 45 U0Q 90 45 1.150 90 45 1.195 Approx. Net Wgt. in Lbs. per tOOO' 23 27 34 49 65 94 135 165 195 235 285 560 445 540 665 S10 985 1120 1330 1460 1690 1805 TYPE AIA f Standard Shipping Length Feet Approx. Shipping Weight per 1000' 500' C 500'C 500' C 500'C 500'C 500 C 500'R 500' R 500' R 500'R 500' R 500' R 500'R 500' R 500' R 500' R 500'R 500'R 500' R 500' R 500' R 500'. R ?7 32 39 54 71 99 168 206 243 293 356 450 556 675 831 1012 1231 1400 1662 1825 2112 2256 *Fin ished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variation in process of manufacture. +C--Coils. R--Reels Not fisted in National Electrical Code. 22 RBB 00493 ROCKBESTOS ALL-ASBESTOS 300 VOLT EXTRA FLEXIBLE APPARATUS CABLE t National tfeetr/eaf Code Type AA MAXIMUM OPERATING TEMP. 150C (302F) 1 This cable was originally developed as "Motion Picture Cable'' for specific use in motion picture projector lamp houses and sun-arc lamps, but its use has been extended to product and industrial applications requiting extra-flexible insulated conductors that will resist the baking effects of high temperatures. The felted asbestos insulation and the asbestos braid ate both impregnated with heat and flame resisting compound to assure the highest possible resistance to heat and maximum flexibility. The braid finish is white. This cable is National Electrical Code Type AA, listed by the Underwriters' Laboratories as Type AA wire and has a maximum operating temperature of 150C (302F). Strand ed Copper conductors employing No. 27 AWG or smaller strands limited to 150C (J02F) by Underwriters' Lab oratories. It will remain flexible under continuous operation at rated temperature, doesn't burn or support combustion even when exposed to an arc, and has typical Rockbestos resistance to-fumes, grease or oil. Standard finish colors: White and black. Authorized stock items: White: TABLE W Size **18 AWG **!($ 14 12 10 8 6 4 2 1 0 00 000 0000 Stranding 41/34 65/34 104/34 259/36 413/36 665/36 1030/36 1666/36 2646/36. 3332/36 4214/36 5292/36 6213/36 8512/36 Bare Diam. Inches .047 .061 .077 .102 .130 .165 .205 .275 .350 .400 .440 .500 .570 .640 300 VOLTS Nominal Thickness-- Mils \ Felted Wall Asbestos Braid ' Nominal Finished Diam. Inches 30 40 j .190 30 40 .205 30 40 .220 30 40 .245 30 40 .270 30 40 .305 40 45 J .5-5 40 45 5 .445 40 43 | .520 60 45 .610 60 45 .650 60 45 | .710 60 45 .780 60 45 .850 Approx. Net Wgt. in Lbs. per 1000' 41 58 75 115 170 255 330 410 300 630 78 0 TYPE AA fStandard. Shipping Length Feet Approx. Shipping Weight per 1000' 500' C 500' C 500' C 500' C 500' C 500' C 500' C 250' C 200' C 200'C 200'C 200' NR 200' NR 200' NR 23 28 36 47 63 80 121 176 262 337 417 507 637 7R7 * Finished diameter* given Above are average. A tolerance of plus or minus returnable Reel*. Not listed tA National Electrical Code. is necmiry due to variation in process of manufacture. tC--Coils. NR--Non* RBB 00494 23 0 II1 ROCKBE5TOS ALL-ASBESTOS 300 VOLT HIGH TEMPERATURE RHEOSTAT WIRE MAXIMUM OPERATING TEMP.: 200C (392FJ -- TABLES A-300, R-300 1S0C (302F) TABLE RF-300 Alt i. sous o* stramoeo fum com* cohouctois i. felted asiestos 1 T 3. ASSESTOS ItAIO FOR GRID JUMPER CONNECTIONS AND CONNECTIONS FROM GRIDS TO FACEPLATES. INFRARED DRVERS. OVENS, ELECTRIC STOVE BUS CIRCUITS, ELEMENT LEADS ON WELL TYPE ANNEALING FURNACES AND OPEN WIRING EXPOSED TO EXTREMELY HIGH TEMPERATURES, CORROSIVE FUMES, GREASE, OIL OR FIRE HAZARD. CONDUCTORS: TABLE A-300 (SOLID) TABLE R-300 (STRANDED) TABLE RF-300 (FLEXIBLE STRANDED) Thee wires are listed by the Underwriters1 Laboratories as Type AA wire. Standard braid finishes ate white and black--colors on special order. TABLE A-300 'Solid) 300 VOLTS TYPE AA ; Nominal Thickness- Mils Nominal | Appro*. tSundard | Appro*. Bice Finished | Net Wgi. Shipping Shipping Diam. Felted i Asbestos Diaffi- j In Lbs. Length j Weight Size Inches Wall | Braid Inches 1 per 1000' Feet : per 1000' *4 18 AWG **l6 24 12 1 `0 8 .040 !. io i 40 .051 ! 30 ! 40 .064 30 I 40 .081 ! JO 1 40 .102 50 40 .228 i 30 ! 40 .180 1 IS .195 1 22 .205 j 28 .225 .245 11 3528 ,270 j 69 500'C 500'C 500'C 500'C 300'C 500'C : ! . . 22 28 33 43 57 79 "Finished diurficter* fiver; above are average. A tolerance of plus or minus S% is necessary due to variation in process of manufacture. tC--CoitJ t TABLE R-300 'Stranded) Size * *18 AWG **16 IT 12 10 8 ! Bite Dim. Standing Inches 77//..001I5922 i! ..004568 ` 7/.0242 ! .073 1 7/.0105 i .092 77//..00438865 j 1 .116 .146 300 VOLTS Nominal Thickness -- Mils i Felted Wall j Asbestos Braid 30 3300 ;i i 4400 40 : 30 1 40 50 ! 40 ! 10 ` 40 Nominal Finished Diam. Inches .190 .200 ..221355 .260 .290 Appro*. Net Wgt. in Lbs, per 1000' IS 25 2494 5742 TYPE AA tStandjrd Shipping Length Feet 500'C 500'C 500' C 500'C 500' C 500' C Approx. Shipping Weight per 1000' 24 2358 45 60 81 TABLE RF-300 (Flexible Stranded) -"18 AWG 30 16 14 i: 10 3 16AO 1(1 26/.OIO 4I/.010 6*'.010 104/.010 133/.0111 ' - .045 .059 .075 .09* .120 .167 30 30 30 30 50 50 300 VOLTS (Maximum Operating Temp. 150C) TYPE AA 40 40 40 ! -10 40 = 40 .185 .200 .215 . .235 .260 .307 i IS 2330 40 56 75 500' C 500' C ' 300' C 500' C 500' C 5(10' C 24 1% 4365 61 88 "Finished diartvettti stven above are average- A tolerance of plus or minus 5% u necessary due to variation in process of manufacture. +C--Coils Not listed in National Electrical Code. 24 RBB 00495 ROCKBESTOS ALL-ASBESTOS 300 VOLT FIXTURE WIRES National Electrical Code Type AF MAXIMUM OPERATING TEMP. 150C (302F) WHITE ASBESTOS INSULATION BLACK ASBESTOS INSULATION SOLID COLOB STAID SOLID COLOB BBAIO WITH MABKEI FOR LIGHTING FIXTURES, SUN LAMPS, OFFICE EQUIPMENT, RADIO APPARATUS, LEADS FOR SMALL MOTORS AND TRANS FORMERS, MINIATURE SWITCHBOARDS, ETC. These heat resisting fixture wires are used for lighting fix tures, sun lamps, office equipment, radio apparatus, leads for small motors and transformers, miniature switchboards, etc. They are approved by the Underwriters' Laboratories for lighting fixture wiring and bear their labels. For fixtures where the wiring is concealed in stems or brack ets, the PLAIN type wire is recommended. It has no braid. Made in black and white to indicate polarity. When wiring is exposed, such as on a chain pendant fixture, ie BRAIDED wire is recommended. Made in solid color raids and solid color with marker thread to indicate polarity. ORDERING INFORMATION Standard Packing: Both plain and braided fixture wires are put up on metal spools and in coils, and where quantity warrants (5000 to 10,000 feet depending on sire) on fac tory reels. Rockbestos plain fixture wire is furnished in standard colors, black, white and ted. Green, yellow, gray, orange and brown can be furnished to order. Authorized stock items r Black and white. Rockbestos braided fixture wire is finished in standard colors, mahogany brown and black in glazed cotton. Other colors and polarity marker threads can be furnished to order. In ordering specify: A.W.G. size and stranding. Whether plain type or braided type. If plain whether half the order black, other half white finish, or all one color. If braided type, whether half order solid color braid, other half with marker or all one way. Color of braid. TABLE FS (plain) f Size | 16AWG ' 16 -l 14 : 12 , 10 Stranding 16/30 26/30 41/30 65/30 104/30 Bare Diatn. Inches .045 .059 .075 .095 .120 300 VOLTS Win. Felted Wall Mils ; ^Nominal ; Finished ' Diameter Inches 31 | .110 31 ! .123 31 i .140 47 : .190 47 [ .210 Approx. Net Wgc. in Lbs. per 1000' 10 14 20 34 48 ^Standard Shipping Length Feet 500' S 500' S 500'S 500' S 500' C TYPE AF Approx. Shipping Weight pet 1000' 12 17 23 37 51 TABLE FSB (BRAIDED) 300 VOLT TYPE AF IS AWG i 16 14 12 ` 10 16/30 26/30 41/30 65/30 104/50 .045 : .059 .075 : .095 ; .120 i 31 51 31 47 47 Finished diameters given ahnve are avenge. A tolerance of plus or minu* 1 .1-10 : .135 ! .170 ; .220 1 .240 12 500'S 14 16 500'S 19 22 500' S 25 37 500'S 30 52 500'C 55 i* necessary due to variation in process of manufacture. tC^^oils, ^--Spools RBB 00496 25 27 RBB 00498 ROCKBESTOS A.V.C. 600 VOLT MINING CABLE MAXIMUM OPERATING TEMP. 110C (230F) 4 I. FLEXIIIE TINNED COffEE CONDUCTOt it EEITCD ASliSTOS 1 1. VARNISHED CAMSIIC 4. FEITEO ASSESTOS J. ASIESTOS MAID FOR ALL INTERNAL CIRCUITS Of ELECTRIFIED MINING EQUIPMENT This original Rockbestos A.V.C Mining Cable was designed to meet requirements for a cable that would operate depend ably under the unusual conditions prevailing in the mining industry and is not a National Electrical Code Standard. Similar in construction to Rockbestos A.V.C. Motor Lead Cable, but made to diameters that fit equipment bushings properly, its impregnated felted asbestos insulation and heavy asbestos braid withstands conductor-heating overloads and the heat of resistor grids in the tightly sealed compart ments of permissible equipment. It won't burn or carry flame, won't bloom, rot or flow under exposure to grease or oil, and has ample resistance to moisture and the destructive action of alkaline water. Standard of leading mining machine manufacturers for de pendability and safety since 1928, it is widely used by mine electricians to keep equipment in full-time operation and reduce maintenance. NOTE: This cable is not designed or intended for use as drag oc reel cable. To avoid error specify Table ML, Rock bestos A.V.C. for use in cutters, loaders and locomotives. Standard finish colors: Black and white. Authorized stock item: Black. TABLE ML 600 VOLTS Bare Nominal Thickness -- Mils Maximum Finished Diam. 1st Felted VC 2nd Felted Asbestos Diam. Size Stranding Inches Wall Insert Wall Braid Inches 14 AWG 12 41/.010 65/.010 .075 .095 10 10 40 40 10 27 1/2 .273 10 27 1/2 .294 10 1O4/.0I0 .120 10 40 10 27 1/2 .313 S 133/.0111 .167 10 40 10 27 1/2 359 6 133/.0140 .210 10 40 10 27 1/2 .405 5 4 I33/.OI58 133/.0177 .237 .266 10 10 40 40 10 27 1/2 .428 10 35 .473 3 133/0199 .299 10 40 10 35 .506 2 133/0223 .335 10 40 10 35 1 259/.0180 .378 15 40 15 45 0 259/.0202 .424 15 40 15 45 00 259/-0227 .477 15 40 15 45 .546 .620 .669 .716 000 0000 250.000 CM 300.000 259/0255 259/0286 427/.0242 427/.0265 .536 .601 .653 .716 15 15 20 20 40 40 40 40 15 45 15 45 40 45 40 45 .779 .849 .988 1.056 350.000 400.000 427/0286 427/0306 .772 .826 20 20 40 40 40 45 40 45 1.115 1.172 450.000 500.000 427/.0325 427/0342 .878 .923 20 20 40 40 40 45 40 45 1.226 1.274 "Minimum diameter 92i/j<7c of maximum diameter. +C--Coils. R--.Reels Approx. Net Wgt. in Lbs. per 1000' 40 51 6~> 95 135 160 195 235 285 370 450 550 675 825 1020 1195 1370 1545 1730 1895 tSiandard Shipping Length Feet 500" C 500'C 500' C 500' C 500' R 500' R 500' R 500'R 500' R 500' R 500'R 500'R 500'R 500' R 500' R 500'R 500'R 500'R 500' R 500' R Approx. Shipping Weight per 1000' 45 56 72 100 168 200 243 293 356 462 562 687 843 1031 1275 1493 1712 1931 2162 2368 26 RBB 00497 ROCKBESTOS TYPE ACA 1000 VOLT LEAD and HOOKUP WIRES TABLE EMA 1000 VOLT LEAD WIRE MAXIMUM OPERATING TEMP. 90C (194F) TABLE ZM 1000 VOLT HOOKUP WIRE MAXIMUM OPERATING TEMP. 125C (257R STEANDEO TINNED COPPEK SYNTHETIC TAPES FELTED ASIESTOS GLAZED COTTON IFAIO-LACOUEF FINISH This 1000 Volt ACA Lead Wire had its inception in appli cation wiring with the advent of cold cathode--slim line-- and mercury vapor fixtures where the initial starting voltages exceed 300 volts, thereby eliminating the use of 300 Volt AF Wire. It had a distinct advantage in its small diameter. Because of this feature, it has also found usage in some in dustrial instrumentation and control circuits in conduit when its use does not conflict with the requirements of the National Electrical Code. Additional uses for this wire are for automotive bus engine compartment wiring and diesel locomotive circuit wiring. Rockbestos 1000 Volt Lead Wire is constructed with non flowing, thin-walled, helically applied synthetic tape and felted asbestos insulation. This construction covered with a glazed cotton braid lacquer finish results in a small diameter wire with high dielectric strength. This wire strips easily and is resistant to heat, cold, flame, moisture, grease and oil. 5TIANDE0 TINNED COPPEI SYNTHETIC TAPES FELTED ASIESTOS LACQUEYED CLASS IIAID Here is a Hookup Wire which has developed many product and electrical maintenance applications. It is similar in con struction to the 1000 Volt Lead Wire shown on this page with the exception that it is covered with a lacquered glass braid overall and is recommended for applications in which abrasion resistance requirements are less severe than for Table EMA. This hookup wire was otiginally developed along govern ment specifications for a glass braided wire suitable for use within electronic devices and instruments which would have high dielectric strength, small diameter and stability in a broad range of operating temperatures. Like Table EMA on this page, Rockbestos 1000 Volt ACA Hookup Wire is resistant to heat, cold, flame, moisture, grease and oil. It can be terminated easily because it strips cleanly and withstands the heat of soldering. This wire can be color coded as illustrated by the use of colored tracers inserted in the white glass braid. TABLE EMA (cotton braid) 1000 VOLTS | Stranding Size 14 AWG ! 19/0142 12 i1 9/.0179 Bare Diam. Inches 071 .090 Nom. Thickness--Inches Synthetic Tape Felted Wall Braid Thickness .010 .020 .0125 .010 .020 .0125 'Nominal Finished Diam. Inches .156 .175 Approx. Net Wgt. in lbs. per 1000' 23 31 TYPE ACA tStandard Shipping Length Feet Approx. Shipping Weight per 1000' 500' C 500' C 28 36 TABLE ZM (GLASS BRAID) 1000 VOLTS TYPE ACA 18 AWG 16 14 12 10 j 16/.010 26/.010 41/.010 65/.010 104/.010 .045 .059 .075 .095 .120 .0065 .0065 .010 .010 .010 .0085 .0085 .0085 .010 .010 .0075 .010 .010 .010 .010 .090 .109 .132 .155 .180 8 * * 1000' 12 **1000' 19 **1000' 28 **1000' 42 *1000' 'Finished diameters given above are average. A tolerance of plus or minus 5% is necessary due to variation* in process of manufacture. +C--Coils. Non-Rerurnsbie reels or metal spools 12 16 23 32 48 27 RBB 00498 ROCKBE5TOS A.V.C. Aflrt unit UlWIWft ROCKBESTOS THERMOSTAT CONTROL WIRE . * 1. INAMlltD CC*H CONDUCTOR ! EOLA*l2ED FELTED AJM5705 3. COATED STEEL AEmO> FOR LOW VOLTAGE SIGNAL, INTERCOMMUNICATIONS AND ALARM SYSTEMS, FUEL BURNER CONTROLS, GAS BURNER SAFETY PILOTS, OVENS, HEATERS, FURNACES, INDUSTRIAL DRYERS, AIR CONDITIONERS, APPARATUS, ETC. The wiring of the control system* of early automatic coai and oil burning installations formerly gave frequent trouble. To get shcit tuns it was often installed dos-1 to, or actually resting on, hot water or steam pipes and the heat naturally deteriorated ordinary insulated wire to the point where trou ble frequently occurred. Cases are on record where serious damage has resulted ftom faulty control wiring. Abrasion, too, has always been a source of trouble when fish ing ordinary control wire, particularly in buildings already up. Sharp corners, brickwork, plaster, protruding nails and rough beams all tend to damage the insulation. With these conditions in mind, and with the wide adoption of automatic fuel burning systems, a large manufacturer of heat control apparatus asked us to design a wire which would be heatproof and abrasion resisting--and Rockbestos Ther mostat Control Wire was the result. Rockbestos Thermostat Control Wife is very strong mechan ically because of its firm felted asbestos insulation and its rugged, abrasion resisting spiral steel armor or metal braid. It i* heatproof and will not dry out under heat or with age. It eliminates fire hazard because it cannot burn. Neither can rats damage it as has been known to happen occasionally with unprotected wires. Where resistance to abrasion ot protection against rodents is not essential, a cotton braid may be speci fied instead of metallic sheath. With these advantages it is of value for control and intercommunicating systems or for any similar application where a low voltage, multi-conduaor cable is required. Rockbestos Thetmostat Control Wire is designed to be useJ at low voltages, usually fed by a step-down transformer. For this application the 12 '-/i mil wall insulation is generally used. However, some users prefer the 25 mil insulation thick ness fot its added mechanical and dielectric strength. Where this cable is to be used direct on 115 volt circuits a minimum insulation thickness of }l Etuis is tecommended. Data fot cables with all three insulations is listed in the table below. Noti: The metal braid covering mentioned in the fourth paragraph is an optional suggestion. TABLE TC I2Va mil. TABLE TCC 25 mi). TABLE TCS 31 mil. Size A.VC'.G. Nominal Wail Thickness Finished Diameters* (Inches) .Number of For Low Voltage Service Conductors 115 Volt Service 121/j Mil O. D. 25 Mil O. D, 31 Mil O. D. 16 16 16 16 18 IS is i ts I 5 4 5 v 3 4 5 .175 .223 .265 .185 .240 .285 .210 .270 .315 .235 .305 .355 .155 .205 .245 .165 .215 .260 .180 .240 .290 .205 .275 .325 Approximate Weights per M Feet (Pounds) For Low Voltage Service 125/2 Mil 25 Mil IIS Volt Service 31 Mil Ntt Ship. Net Ship. Net Ship. 35 41 43 49 47 53 46 52 56 62 62 68 58 64 69 75 79 85 69 75 34 90 97 106 26 30 34 40 37 43 34 39 43 49 49 55 43 49 53 59 61 67 50 56 64 70 75 81 Standard Shipping Lengths (Feet) Coils 500 500 500 500 500 500 500 500 Finished diameter* $iven above ate average. A tolerance of plus or minui i* necessary due ro variation in proctif of manufacture. 2$ RBB 00499 ROCKBESTOS INDUSTRIAL HEATING CABLES TABLE LH MAXIMUM LEAD SHEATH TEMP. 350F. TABLE LHV MAXIMUM LEAD SHEATH TEMP. 165F. L\L. Approved, by report for pipe heating applications SFECfAL AUOT WIRE PEITEO ASBESTOS LEAP SHEATH SPECIAL FELTED ALLOT WIRE ASBESTOS VANISHED CA*BtlC LEAD SHEATH FOR THE CONTROLLED DISTRIBUTION OF MILD HEAT TO PREVENT FREEZING OF WATER, WASTE PIPES, EAVES TROUGHS, DOWN SPOUTS AND VALVES--TO INSURE FLOW OF VISCOUS FLUIDS, OILS, PAINT, CHOCOLATE. ETC. This Rockbestos heating cable was originally developed to force the growth of early spring plants in hothouses. After its introduction to florists, market gardeners and amateur horticulturists, it found its way into industry as a useful heat source for the distribution of even mild heat. It performed to better advantage and more economically than spot or strip heaters. Pliable, easily bent and formed, it can be threaded through apertures or made to conform to irregular shaped objects. It is best used wrapped around pipes and cov. ered with a good standard pipe insulation for greatest economy. We can only touch on a few typical applications to which our customers have put this heating cable, but they will give you a good idea of the varied uses to which it has been put. In many plants the cable is used as a safeguard against frozen water pipes making unnecessary the rearrangement of piping or costly replacement. Waste pipes, eaves troughs and down spouts can also be kept free and clear of ice. Paint, soap, varnish, ink, chocolate, molasses and sulphur, to name a few, can be kept at fluid temperatures insuring against irregular flow and clogged conveyor pipes. Wet pipe sprinkler systems located in unheated areas are easily heated and kept at non-freezing temperatures that assure positive operation. Steel nulls use it around roll-necks to prevent the lubricant from congealing and a utilities ^engineer wound the cable around the pipes connecting the conservator tank to the main tank of a conservator type transformer, covered ir with lagging, and eliminated congealing of oil and freezing of condensate. The resistance of Rockbestos Industrial Heating Cable is approximately 0.5 ohms per foot. In order to keep the temperature low enough so that the insulation will not be injured, the generally recommended length across 115 volts, is 60 feet. The recommended wattage limit is 7 watts per foot. At 110 volts a 60 ft. length is rated at 400 watts, 6.66 watts per ft. Across 220 volts use a 120 ft. length for the same current value and double the total wattage. Caution: Do not use Table LH where maximum voltage exceeds 120 volts to ground. Table LHV is suitable for 440 volt service in 240 foot lengths and is U.L. approved by report for pipe heating applications. When installed permanently, Rockbestos Industrial Heating Cable should be cov ered by some form of heat insulating material for operating economy. Precise temperature control is established by means of a low priced thermostat available from a number of manufacturers. We will be glad to refer you to several. The characteristics of this particular heating cable are given simply because it is a standard product and usually available from stock. We are equipped, however, to make up heating cable characteristics to your specification. Furnish complete details concerning temperature desired, heat dissipation, etc. with inquiry. In applications where this cable is used close to physi cal contact with personnel, the lead sheath should be grounded. Other industrial heating cables are shown on the follow- Typical installation of industrial beating cable to pipes using insulation and thermostat for precise temper ature control. TABLE LH and LHV : Approx. A.W.G, Table Sire Conductor Bare Dtam. Inches ; Approx. j Resistance ; Ohms per Ft. Nom. Thickness Insulation Mils Lead Sheath Inches `Nominal ! Finished : Diam. Inches Approx. Net Wgt. in Lbs. per 1000' Standard Shipping Length Feet Shipping Weight in Lbs. per 1000' LH LHV 19 Nickel .0M Chrome Iron 19 Nickel Chrome Iron CM .5052 .5052 | 40--Asbestos j ! 51--Asbestos i 21--Varnished ' Cambric -,/M .215 .240 143 60, 120 and 240 ft. lengths end in bulk 160 on Reels Finished diameter! given above are average, A tolerance of ptus or minus J% is necessary due to variation in process of manufacture. 178 on Reels 200 on Reels 29 ABB 00500 ROCKBESTOS SPECIAL INDUSTRIAL HEATING CABLE TABLE LHT I TABLE LHG n THESE ROCKBESTOS HEATING CABLES ARE TYPICAL OF THE SPECIAL CONSTRUCTIONS DEVELOPED TO MEET THE SPECIFIC REQUIREMENTS OF OUR CUSTOMERS. THEY ARE SHOWN ONLY TO ILLUSTRATE VARIED CONSTRUCTIONS SUCCESSFULLY DEVELOPED FOR INDUSTRIAL AND PRODUCT USES WHERE THE APPLICATION OF A CONTROLLED HEAT SOURCE WAS NECESSARY. CONSTRUCTION CONSTRUCTION 1. Special Alloy Wire 2. Felted Asbestos 5, Teflon Tapes 4, Felted Asbestos 5. Lead Sheath 1. Special Alloy Wires 2. Felted Asbestos j. Teflon Tapes 4. Felted Asbestos--Silicone Treated 5. Glass Braid--Silicone Treated I Here is a special lead sheathed heating cable designed to Along with the trend toward outdoor power plants came solve a problem in the manufacture of refrigeration units. the need for protecting high tempeuture steam and gage The problem was to speed the time required in the deicing iines from freezing during shutdown periods. Rockbestos cycle without appreciable temperature rise in the cold cham Field Engineers called in to study this problem designed ber. The answer here was to design a heating cable suitable this special construction to be applied between the layers of for higher voltage operation than our Table LH industrial pipe insulation. This provided an ideal solution as the sili heating cable shown on page 29. This heating cable con cone treated insulation and silicone treated glass braid con struction has successfully solved this problem. It is suitable struction withstood the high temperatures developed during for 440 volt service and has a maximum Sheath tempera the normal operation of steam lines and when steam lines ture of 350F. were not operating provided a heat source of sufficient temperature to keep the condensate from freezing. This heating cable is rated at 440 volts and has maxi mum operating temperature of 500F. Rockbestos Heating Cable Designs can be developed to solve yout electrical heating problems--furnish complete data cov ering temperature desired, heat dissipation, etc, with jour inquiry. 30 RBB 00501 ROCKBESTOS HEATING CABLE KITS and THERMOSTATS 9 ROCKBESTOS HEATING CABLE KITS for Roof De-icing--Ripe Heating and Soil Heating Application* FOR THE HOME-ON THE FARM- IN MOBILE HOME PARKS Available in 3 Handy Sizes: 60 ft. kit (30 ft. loop)--460 watts 40 ft. kit (20 ft. loop)--260 watts 20 ft. kit (10 ft. loop)--130 watts Complete instructions with each kit. AH operate on 110-120 volts AC or DC THESE LEAD SHEATHED HEATING CABLES WITH FLEXIBLE NON-HEATING CONNECTOR PERMIT: Repeated "plug-ins" withour damage to the cable Unlimited uses thru weatherproof construction Better heat conductivity than non-metal sheaths Easy application ro irregular shaped objects A COMPLETE UNIT ready to plug inro any standard 110-120 volt AC or DC outlet ROOF DE-ICING: This cable serves as a source of mild heat to prevent the formation of ice dams which cause destructive leaks on building or house roofs, including gabled roofs. The current is turned on only when rain or snow is expected and the temperature drops below freezing. The kits come in 20, 40 and 60 ft. lengths (the latter com plete with 8 shingle damps), depending upon the overhang of the eaves. With average house construction one 60 ft. kit will protect 20 running feet of roof. PIPE HEATING: Electric heating cable can easily be applied ro water pipes, whether buried in the ground or exposed, to give positive protection against the damage caused by freeze-ups or broken pipes. For maximum coverage of pipe length, the cable should be applied parallel: bur where greater protection is needed in low temperatures, the spiral method can be used. When applied this way, rhe cable will increase the heat applied because of the greater concentration of heat. SOIL HEATING--HOT BEDS and COLD FRAMES: The heating kit serves as a dependable heat source in hotbeds, cold frames and propagating benches ro stimulate faster growth for plants and cutrings. Cuttings will root and plants will grow 20 to 30 times faster this clean scientific way. Once the cable is installed, it may be left in place indefinite ly. To insure proper seed germinarion a thermostat is necessary to accurately control the heat. For this purpose we recommend using Rockbestos Weatherproof Thermostat LT-56 adjustable for Temperatures of 30-100F. ROCKBESTOS WEATHERPROOF THERMOSTAT LT-S6--with Pilot Light Indicator Automatically Controls Temperatures in Electric Heating Cable Kits for Maximum Economy in Power Consumption Quickly ' installed Automatic protection Multiple control PIPE HEATING APPLICATIONS: The thermostat should be mounted directly on the pipe itself, selecting the coldest spot along its length. Five feet of cord leading from the thermostat is provided for connection to a 110-115 volt AC power source. Secure the thermostat to the surface of the pipe with a suitable wire or cord, passing it through the small "ears" on either side of the thermostat. Simpiy plug the thermostat cord into your power source and plug the heating cable into the back of the thermostat plug When pipe covering is used, extend pipe covering to cover thermostat, leaving only dial exposed for setting. Set the thermostat for the temperature at which heating is to start (approximately 37F. for pipe heating) and thermostat is ready to operate. HOT BEDS, COLD FRAMES or PROPAGATING BENCH APPLICATIONS: The thermostat may be mounted within the frame itself when air temperature control is all that is required. When used to control soil Temperatures, the thermostat itself may be buried, allowing the dial and setting knob to be exposed for final dial setring. The weather-proof consrrucrion provides protection against moisture encountered in wetting the soil at required in tervals. . SPECIFICATIONS Rating 15 amps on 115 volts AC Temperature Range 30 F to 100 ^ F maximum Cord lensrh 5 feet from outlet to thermostat Thermostat Construction Weather proof moulded plastic enclosure Pilot Light Built inro thermostat plug--light .clows when heating cable l$ calling for heat. CAUTION: Do not install with (able touching itself in any application RBB 00502 31 STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES Many companies have requested suggestions for a standard specification to aid them in the ordering of Rockbestos wires and cables. The following specification has been formulated for that purpose and covers Rockbestos A. V. C. and All-Asbestos constructions described in this catalog. NOTE: This specification is in accordance with the requirements of the National Electrical Code and the National Electrical Manufacturers Association Standards for Asbestos and Asbestos-Varnished Cambric Insulated Wires and Cables with which all Rockbestos wires and cables of standard construction comply. I General (a) Purpose: The purpose of this specification is to insure the furnishing of wire and cable of the proper quality, manufactured in accordance with accepted practice, (b) Scope: This specification covers the construction and test requirements for asbestos-varnished cam bric and all-asbestos insulated wires and cables. (c) Materials and Workmanship: All materials and workmanship employed in manufacturing wires and cables to this specification shall be of high quality so as to provide a finished product best suited for the purpose intended. (d) Applications A.V.C. Insulations. These wires and cables are suitable for operation at the specified voltages in either open or con duit installations in locations where they must operate under both heat and casual moisture con ditions. If wire or cable is to be installed where it may operate under excessive condensation conditions or be submerged, lead sheathed type should be specified. All-Asbestos Insulations. These wires and cables are suitable for operation at the specified voltages as exposed wiring in high temperature locations where little or no moisture is encountered. II Conductors (a) Solid: Solid conductors shall be either plain, tinned or lead alloy coated copper in accordance with current ASA or ASTM specifications. (b) Stranded: Stranded conductors shall be bunched, concentric or rope lay as required. The make-up of stranded conductors shall conform to current ASTM specifications. The individual strands shall be as specified for solid conductors in 11(a). (c) Conductors other than copper shall be specified to meet individual requirements. III Insulation (a) Asbestos 1. Material: The asbestos insulation shall consist of selected quality, long fibre, chrysotile asbestos commercially free from foreign particles of dirt, cotton seed and metallic oxides. It shall be well carded to prevent lumps and irregularities in the finished wire or cable. The asbestos insulation shall be applied to form a smooth, felted wall of uniform thickness as specified in the tables. The asbestos insulation after extraction of the impregnating compound shall contain not less than 80% by weight of asbestos. The total iron content shall not exceed 4% by weight of the asbestos. 2. Impregnation: The asbestos insulation shall be dried and saturated with a flame and heat resisting compound or a flame, heat and moisture resisting compound as specified. The compound shall consist of suitable high grade ingredients and shall retain its initial qualities during the normal life VSr' 32 RBB 00503 STANDARD SPECIFICATION FOR R0CKBE5T05 A.V.C. AND ALL-ASBESTOS WIRES AND CABLES 9 - of the wire or cable, The compound shall develop no injurious chemical action within itself or with any component parts of the wire or cable. (b) Varnished Cambric 1. Material: The varnished cambric insulation, when used, shall consist of a high grade varnished cloth substantially free from blisters or other imperfections. 2. Application: The varnished cambric shall be applied with lubricating compound between layecs and to the wall thickness specified. IV SEPARATORS Unless otherwise specified, suitable separators may be used over the conductor or between component layers of insulation, V Braids (a) Asbestos 1. Material: The asbestos yarn shall be of selected quality, long-fibre, chrysotile asbestos contain ing not less than 80% by weight of asbestos. The total iron content shall not exceed 6% by weight of the asbestos. 2. Application: Asbestos braids shall be applied to conform to current NEMA standards. 3. Finish: Asbestos braid shall be finished with a suitable flame and heat resisting compound or sat urated and finished with a flame, heat and moisture resisting compound as specified. (b) Cotton Marker Braids for Multi-Conductor Control Cable Marker braids shall comply with the current requirements of ASA specification for Cotton Braid 9 for Insulated Wire and Cable for General Purposes--Code Braids (commonly known as NEMA Class A braid). (c) Finished Cotton Braid for Outer Covering 1. Finished braid shall comply with the current requirements of ASA specification for Cotton Braid for Insulated Wire and Cable for General Purposes--Standard Braids (commonly known as NE MA Class B braid). 2 This cotton braid shall be finished with a flame and heat resisting compound or saturated and finished with a flame, heat and moisture resisting compound as specified. VI Metallic Coverings Coverings such as lead sheath, spiral, basket weave and interlocking armor, when required, shall com ply with current NEMA specifications for metallic coverings. VII Cabling (a) For cables consisting of more than one conductor (except flat twin cables) the individually insu lated conductors shall be concentrically cabled together. The lay of the conductors in each layer shall not exceed 16 times the pitch diameter of that particular layer. The direction of lay of the conductors in each successive layer shall be reversed. (b) Where circuit identification is required it shall be accomplished by coloring the insulation or by the use of marker braids. (c) When required, fillers shall be used and shall be of jure or asbestos, dry or impregnated with a moisture resisting compound. (d) In cables with coded conductors or when required for manufacturing reasons, a tape shall be ap plied over the cabled conductors. VIII Tests A. Physical I. Dimensions: Inspection for dimensional requirements shall consist of four determinations, two to RBB 00504 STANDARD SPECIFICATION FOR ROCKBESTOS A.V.C. AND ALL-ASBESTOS WIRES AND CABLES be made near each end of the sample of which the average shall comply with the requirements giv en in the tables. The measurements of cable % inch diameter and smaller shall be made with a ratchet micrometer having 14 inch diameter faces. For cable larger than % inch diameter the meas urement shall be made with a circumference tape. Each determination, when made with a micro meter, shall be the average of two measurements made at right angles to each other. 2. Resistance to Flame: All wires and cables made to this specification shall have fite resisting prop erties so that the test specimens will meet all of the requirements of the Underwriters' Laboratories standard vertical flame test. E. Electrical 1. Initial Dielectric Strength (a) Single Conductor, Initial dielectric strength tests shall be made on 5-foot lengths of finished wire or cable with the center 3-foot section wrapped with metal foil. Voltages as indicated in the tables shall be applied for 5 minutes on wire or cable rated 600 volts or over, and for 1 minute on wire or cable rated 300 volts. (b) Multi-Conductor. Initial dielectric strength tests shall be made on full reel lengths of finish ed cable by applying iy2 times rated voltage between each conductor and all others for 5 minutes. Also an initial dielectric strength test shall be made on 5-foot lengths of finished cable, with the center 3-foot section wrapped with metal foil. Voltages as indicated in the tables shall be applied between each conductor and all others and metal foil, and between all conductors and metal foil, for 5 minutes on cable rated 600 volts and over, and for 1 minute On cable rated 300 volts. (c) Metallic Covered Cable-. Initial dielectric strength tests shall be made on full reel lengths of metallic covered cable by applying 2I/2 times rated voltage between conductor and covering on single conductor cable, and between each conductor and other conductors and the metallic covering on multi-conductor cable for a period of 5 minutes. 2. Dielectric Strength After Flame (a) A sample of wire or cable having been previously subjected to the flame test shall be prepar ed with the charred area of sizes No. 6 and larger wrapped in metal foil, and sizes smaller than No. 6 buried in iron filings or fine shot. Test voltages applied for 1 minute shall be as follows: (1) Asbestos-varnished cambric insulated wires and cables rated at 600 volts or more, 11/2 times rated voltage. (2) All-Asbestos insulated wires and cables rated at 600 volts, 21/2 times rated voltage. (3) 300 volt rated wires and cables, L000 volts. 3. Dielectric Strength While Immersed A 5-foot sample of finished wire or cable having flame, heat and moisture resisting finish shall have the center 3-foot section immersed for 1 hour in tap water at room temperature, and while still im mersed shall withstand a dielectric test of 2 times rated voltage applied between conductor and water for 1 minute. IX Sampling (a) Each of the required tests shah be made on one sample of each size and type of wire or cable from each lor of 10,000 feet or fraction thereof. (b) If a sample fails to meet a prescribed test requirement, two additional samples shall be taken from the same length. If the two additional samples meet the test requirement then the lot shall be accepted. If either of these samples fail the length may be rejected. (c) If any length is rejected for failure to meet a requirement, then a sample shall be taken from each length of the balance of the lot and subjected to the particular test requirement to determine acceptance or rejection of that length. ^ _ ' 34 Rbb ooaos SWITCHBOARD WIRES and FULL REEL TESTS 9 Type Page SPECIAL TESTS FOR SWITCHBOARD WIRES (IPCEA Standard S-28-357) (NEMA Standard WC-1-551 Des crip tion Rated Voltage Initial Dielectric Ttsa Period of Test Voltage Appli cation Minutes Test potentials <KV) to be applied to sizes 18*8 6-2 1-4/0 AWG AWG AWG Standard Flame Resistance Test NEMA AVC &78B Dielectric Failure Test NEMA AVC 6-gODl Leakage Resistance Bend--Dielectric Test Test NEMA AVC 6-S0D2 NEMA AVC 6-80D^ AVB 17 Switch- 600 5 3-0 4.0 4.0 board Wire AVB 18 Hinge - . . Cable ta 19 Switch- 600 5 3-0 4.0 5.0 Wire TA 19 Hinge 600 Cable 5 3.0 4.0 3.0 X Shall withstand not SampJe with ends Two 90 bends on a less than 15.000 volts sealed and foil bands 15" sample in the conductor to metal 2" apart exposed 16 same plane 2" apart foil on an unbent hours at temperature around mandrel hav- sample. Voltage rais- not less than 25C ing same diameter as ed at uniform rate of in dosed chamber sample. No rupture from 500 to 1000 containing open ves- of covering and shall X volts per second. sel of water. Remov- not break down it ed and 200 volts D.C. less than 5000 volts immediately applied conductor ro metal between bands. Leak- foil, filings or shot. X age resistance shall Voltage raised nr uni- be not less than 1 form rare of from megohm per inch 500 to 1000 volts length per inch of per second. circumference. Test required onlv of sizes 8 AWG and smaller. Type AVL AVA AVL TESTS TO BE MADE ON EACH FULL REEL LENGTH (IPCEA Standard S-28-357) (NEMA Standard WC-1-55) Page Description Conductors Single Mulri-Conducror Lead Sheath Rated Voltage Full Red Dielectric Test NEMA AVC 6-SO A 2 and A4 eTest Voltage (KV) 14 Lighting Wire X X 600 1.5 10-11 Control Cable X 600 1.5 15 Power Cable X X 600 1.5 On Type AVL Single Conductor Cables voids* shall be applied for J tninurei between conductor ind lead sheath. On Type AVL Multi-Conductor Cables voltage shall be applied for 5 minutes between conductors and between the outer layer of conductors and lead sheath. On Type AVA Mulri-Condurtor Cables voltage shall be applied for $ minutes between conductors. RBB 00506 35 TESTS ON SAMPLES OF FINISHED CABLE i i tIPCEA STANDARD S-28-357) (NEMA Standard WC-1-55) Type AVA AVL AA aia AF Pages Description 12 Lighting Wire 9 1/C Power Cible 9 Motor Lead fit 13 Apparatus Cable 11 Control Cable 14 Lighting Wire 15 i/C Power Cable 15 25 Apparatus Cable 22 Rheostat Wire 23 Power & Rheostat Cable 24 Apparatus Cable 27 Fixture Wires Rated Voltage Initial Dielectric Tests--(Kilovolts) NEMA AVC 6-80A Standard 1 Minute Flame Dielectric Tests (kv) Test Period Minutes All Sues H3-16 AWG 1+4/0 AWG 230 1000 Mat Resistance After 1 After Above Test Flame 1 Immersion tooo NEMA NEMA 1 NEMA MCM AVC6-78B AVC 6-SOB ! A VC 6-80C 600 600 5000 600 600 600 600 5000 . 300 600 600 600 300 5 -- 30 3-0 -- -- X 5 -- 30 3.0 4.0 5.0 X 5-- 12.5 12.5 -- X 5 -- 30 3.0 4h0 -- . X 5 3.0 -- -- -- -- X 0.9 | 1.2 0-9 l'2 7.5 i 10.0 i 0.9 : 1.2 0.9 ( 1 1.2 Not Reqnirea--See Test on full Reel Lengths 1 s 5 1.0 -- -- _ __ _1.5 -- -- 1.5 -- _ _ _ X X X 5 1.5 -- -- -- -- X 1 1.0 -- 0.9 0.9 1.7 0.9 1.2 Tests as required by Underwriters' Laboratories Standard for Flexible Cord and Fixture Wir *Oa single conductor cable* voltaic shall be applied between conductor and metal foil wrap. On multi-conductor cables voltage shall be applied between conductors and between the outer layer of conductors and metal foil. **VolTige shall be applied between conductor and metal foil, iron filings or fine shot as required. Voltage shall be applied between conductor and water. ! 36 RBB 00507 ALLOWABLE CURRENT-CARRYING CAPACITIES OF INSULATED COPPER CONDUCTORS IN AMPERES (Bated on Room Temperature of 30C. 86F) NATIONAL ELECTRICAL CODE--TABLE 310-12 Not more Hum thro* (onductori In Rat-way a. Cab!* or Dine* Ivrial Size AWG MCM Rubber Rubber Paper Type R Type RW TiBr Thermo* plastic Type RU RUH TypeRUtP (14-21 Asbestos TTaTA (14-2) Vtr-Cam r5?w See note 9 Type V See note 9 Thermo* plittie Sr? Thermo* Asbestos Vir-Cam Type AVB Type T plastic Ml Cable Type W Type THW RHH* Asbestos Vaf-Com WX IK Impreg nated Asbtttos Tir fH-8> Set Asbestos Type A (M-8> Type AA 14 15 15 25 30 30 30 12 20 20 30 35 40 40 10 30 30 40 45 50 55 3 -40 45 50 60 65 70 6 55 65 70 80 85 95 4 70 85 90 105 115 120 3 80 100 105 120 130 145 2 95 115 120 135 145 165 1 no 130 140 160 170 190 0 125 150 155 190 200 225 00 145 175 185 215 230 250 000 165 200 210 245 265 285 0000 195 230 235 275 310 340 250 215 255 270 315 335 500 240 285 300 345 380 350 260 310 325 390 420 400 280 335 360 420 450 500 320 380 405 470 500 600 355 420 455 525 545 700 385 460 490 560 600 750 400 475 500 580 620 800 -410 490 515 600 640 900 435 520 555 1.000 455 545 585 680 730 1.250 495 590 645 1.500 520 625 700 785 1.750 545 650 735 2.000 560 665 775 840 CORRECTION FACTOR FOR ROOM TEMFERAUIRES OVER 30C. AF. NATIONAL ELECTRICAL CODE--TABLE 310-13 Sin?]* conductor in frg* Atr Size AWG MCM Rubber Type R Type RW Rubber TiBr Thermo plastic Asbestos Type RU RUH Type RUW <14-21 <U-2) Sr* JtioftW See store 9 See note 9 Tbermn- t&fv Type TA $A Ver-Cim Type V Asbestos Vir Cim A$A Asbestos Vtr-Cam Iw Type AVB Impreg nated Asbestos Asbestos Tjtr Type A <14*8) (14-t) Type AA Type AIA Pltttit Thermo MI Cable Type T plastic Type TV IType THW RHH* SlowBurning T/f 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 300 600 700 750 800 900 1000 1250 1500 1750 2000 20 25 40 55 80 105 120 140 165 195 225 260 300 340 373 420 455 515 573 630 655 680 730 780 890 980 1070 1155 20 25 40 65 95 125 145 170 195 230 265 310 360 405 445 505 545 620 690 755 785 815 870 935 1065 1175 1280 1 $85 30 40 40 45 40 50 50 55 55 65 70 75 70 85 90 100 30 40 55 70 100 120 125 135 135 160 170 180 155 180 195 210 180 210 225 240 210 245 265 280 100 130 150 175 205 245 285 305 325 235 285 330 355 370 275 330 385 410 430 320 385 445 475 510 370 425 493 530 430 533 590 530 610 655 575 665 710 660 765 815 410 460 510 555 630 740 855 910 815 940 1005 845 960 1045 880 1020 1085 940 710 780 810 845 905 1000 1130 1260 1370 1470 1165 1450 -- 1711 1240 ., 965 .... 1215 1405 CORRECTION FACTOR FOR ROOM TEMPERATURES OVER 30C. S6F. CF CF 40 104 .82 .88 .90 .94 .95 40 104 .82 .88 .90 .94 .95 45 113 .71 .82 .85 -90 .92 45 113 .71 .82 .85 .90 .92 50 122 .38 .75 .80 .87 .89 50 122 .58 .75 -80 .87 .89 55 131 .4! .67 .74 .83 .86 , . 55 131 .41 .67 .74 .83 .86 60 140 70 158 75 167 80 176 .58 .67 .79 .83 .91 60 140 .35 .52 .71 .76 -87 70 158 .43 .66 -72 .86 75 167 .30 .61 .69 .84 80 176 .58 .67 .79 -83 .91 .35 .52 .71 .76 .87 .43 .66 .72 .86 .30 .61 .69 .84 90 194 100 212 120 248 140 284 .50 .61 .80 90 194 .51 .77 100 212 .69 120 248 .59 t40 284 .50 .61 .51 .80 .77 .69 .59 -The aurem-ciriyinr cipiaiia for Type RHH conductor* for sizes AWG 14, 12 end 10 shall be the same as designated for Type RH conductors in this Table. a NATIONAL ELECTRICAL CODE (NOTES TO TABLES 1. Explanation f Tahiti, Ear 4-atp-ion-ori-on of Typo lottort, end for racapniied sij* af conductars for the various conductor insulations, ih 5*ctiani 3tOT and 310-3, For iniiolldl*ft raQuiremartls. ia Section 310-1 through 310-7, and tho various Articles of Ihit Cod*. for ft+xibl* card* tH Tablac 400-9 and 400-11. 2- Application of Tobl*. far apon wiring on insulators and far concaoled knob-and-lub* work, rh# allowable curr#flt.<orrying cooociMoi of Tablet 310-13 and 310-15 shall Pa W(Od- far Oil 0th*r r#<gnil*d wiring mofhadt, (ha allow able current-carrying copocili** of Tablet 310-12 and 310-14 shall bo vtod, unless otherwise provided in Ihit Cad*. 3. Aluminum Conductors. For aluminum conductors, eh* allowable current carrying caoocitio* shall bo in OCcardafico with Tcbloi 3)0-14 and 310-15. 4. Bar* Conductors. Wh*r* bar* conductors or* vt*d with insuloi*d conductart. rb*rr gllawabl* eurr*nf-<erryFg capacity shH b* limited la that per mitted far iho insulated conductors of tb* tom* t>z*. 5. Typo Ml Cable. Th* temporatur* limilglion on which lh* current-carrying capacities of Typo Ml coble are based, it determined by th* insulating materials vied in Ih* *"d t*al. Termination fitting* incorporating n<mpr*gnet*d erganie insulating materials ar* limited 10 85*C. OPOrotian. 6. Ultimate |nalaflart Tomperetvr*. In no cat* shall conductor* be associ ated together in such g woy with respect to Iho kind *f circuit, th* wiring method emoloyed. et the number of conductors, thgt th* limiting tomperotwr* of the conductors will be exceeded. 7. Use ef CwFudsn With Higher Operating Temperaturn. Whet* the room temperature it wiihin 10 degrees C .of tho maximum allowable operating tem perature of the insulation, it is detirablo to wto an insulation walh a higher maximum allowable operating temperature; althowph iniuloiioo cert bo used in a room temperature approaching in masimvm allowable operating romper#, lure limit if the current it reduced in occordonc* with th* Correction Factors for different room temperatures. I. Mere Than Three Conductor* in a Raceway or- Cable. Tablet 31(3-12 and 310-14 give the allowable Current-carrying capacities for not more than three conductors in a raceway os cable. Where the number of conductor* in a 310-12 and 310-13) raceway or cable exceeds thro*, the allowable current-carrying capacity each conductor shall be reduced as shown in th* following Table: Number af Fr Cant of Volwci in Cenduciort * Tables 310-12 and 31Q-H O' 4 to d 7 to 34 80 ... 70 25 to 42 60 4) and above SO Eictslion---When conductors of different systems, as provided in Section 300-3. at* installed m a common rocewov rh* derating facrars shown abov* apply to the number af Fewer and Lighting (Articles 210. 215, 220 and 230) con ductors only. 9. Where Type tH-RW rubber insulated wire it used in wet locotiant th* allowable curranl-catrying capacities shad be tAdl of Column 2 m Tobies 3)0-12 through 310-15- Where used in dry locations the allowable Current carrying copac'tias shall be that ef Column 3 in Tobies 310-12 through 310-15. 10- Over<wrr*#it Protection. Where th# standard ratings and soilings af e*rcurrent devices do net correspond w*th th* ratings and settings allowed for conductors, rh* noit higher standard rating end setting may be uiad. 11. Neutral Conductor. A neutral conductor which carries only the unbal anced current from other conductors, os in the rase of normally balanced circuits ef three ar more conductors, tholl net bo counted in determining curienl-carrying capacities at provided far in Note 8. In a 3-wire circuit consisting ol two phase wires and th* neutral of a 4-wire, 3-phase system, a common conductor corriei approximately th* same current os in* other conductors and is not tharefora considered as a n*viral conductor. 12. Voltage Drop. The oliewobl* current-carrying capacities in Tobies 31&-12 through 310-15 are based an temperature alone and da net lake voltage drop into consideration, 13. 0*f*ri*ceiien ef Insulation, Is should be noted that even th* b*t' grades af rubber insulation will deteriorate in lime, so eventually win n*d i* be replaced. RBB 00508 CONDUIT SIZE TABLES Percent Occupancy Allowed by NEC. (For Rewiring tee page 39) 4 TABLE C 600 VOLT A.V.C LIGHTING WIRE -i Cable Size Cable Diem. Inches ---------------1-----------12 Number of Cables in Conduit 3| 4| 5f 6j 8j9 i 18 .220 16 .233 14 .245 12 .263 10 .285 8 .310 6 .385 5 .405 4 .425 3 .450 2 .480 1 .540 i/o .575 2/0 6t5 3/0 .660 4/0 .710 1/2 1/2 1/2 1/2 1/2 t/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 l 1/2 1/2 5/4 3/4 3/4 3/4 1 1 1 1/4 J 1/4 1 1/4 1 1/4 t !/2 l 1/2 > 2 i/2 3/4 3/4 3/4 3/4 3/4 i 1 1/4 i 1/4 t 1/4 1 1/4 1 1/2 1 1/2 -> 2 2 Minimum Size of Conduit 3/4 3/4 3/4 1 1 1 l 1/4 V 1/4 1 1/4 1 1/2 1 1/2 2 2 1/2 2 t/2 3/4 i i > 1 1 1/4 1 1/4 i 1/2 1 1/2 l 1/2 2 ! > 2 1/2 2 1/2 3 i i !i !1 I 1 1/4 1 1/4 ! 1 1/2 i 1 1/2 !2 2 2 t/2 ' ?!.'> 2 1/2 3 3 1 I !t : i 1/4 i 1/4 i K4 i 1/2 2 *i 2 ' 2 1/2 1 - 1/2 '* Ii i i 4 l i 4 i:4 i i /4 , i '2 11 2 > ' "I !2 : . 2 /; !5 i5 I! 33 : !i : 1 '4 1 .'4 ' 1 '4 114 1; 2 2 -< 2 ; 4 3 3 3 .3 ; TABLE E 600 VOLT A.V.C. POWER CABLE Cable Size Cable Inches tl2 Number of Qbles in Conduir 3 4 i 5 1 6 -> 89 Minimum Size of Conduit i IS .235 1/2 J/2 3/4 3/4 ; 1 j1 16 .250 1/2 3/4 3/4 V4 ; 1 i 14 .265 1/2 3/4 3/4 1 l ; 1 1 i 1/4 1 14 1 14 1 I-4 I1 1 14 1 I4 12 .285 1/2 3/4 3/4 1 ii ; I 1/4 i 1/4 I 1.-4 ! 14 iO s .310 .*50 1/2 1/2 3/4 1 3/4 l 1 1 i/4 1 l-*4 ` I 1,4 : i.-4 1 !4 i 1 '4 i I- 2 I 1/2 i i: I 1T ( .405 1/2 1 1 1/4 1 1 '4 1 1/2 : i i : ! .430 1/2 1 1/4 1 1/4 1 11 i i 1/2 2 :2 4 455 3/4 ! 1/4 l 1/4 1 1/2 i 1/2 - * 2 4SO 3/4. 1 1/4 1 1/4 1 t.'2 2 > -* 4 J - -i -515 3/4 l 1/4 I 1/4 y .5S5 3/4 1 t/2 t 1/2 2 ^ 1 '2 : 1/2 > 4 2 : 1/2 2 1/2 i > 10 .625 l 2/0 6~0 1 1 1/2 2 2 2 > 1/2 . 2 : : l/: 2 1/2 l 3 3 `> i 3 U "20 1 40 "SO 1 1/4 y 2 2 2 1/2 1/2 3 3 3 3 ; 3 1/2 3 i : 3 1.'-' 3 < 4 250 *00 3 50 4UU ; 4 50 500 350 ODD 3^5 9*0 .985 1.0*0 1 -0"5 1 115 1 165 1 205 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 t 1/2 1 1/2 2 2 1/2 > 1/2 3 3 3 3 2 1/2 2 1/2 3 3 3 3 3 1/2 3 i/: | 3 3 1/2 3 1'2 3 i-': 1 '2 4 1 j : 1 3 I/; 3 '2 3 1/2 4 4 4 4 la 2 4 '2 ' ' * 1 '2 4 4 4 4 i *: 4 1-2 5 5 4 4 4 1/2 4 1 '2 4 1/2 5 5 4. 4 4 1/2 4 1 `2 5 5 6 * 4 44 5 5 6 6 6 6 650 700 "50 Sill.) S50 OIK) 050 1000 1250 1 SOO i`50 2000 . 1 240 l 2"5 1 *10 1 *-15 i t-i E 105 14*5 1 165 1 0 10 I "65 i sso 1 *>S5 i . J j ! I ; ; 2 2 2 2 : 2 2 * v 1 '2 * 3 1/2 > t/2 3 1/2 3 1/2 3 1/2 4 4 1 -t t'2 4 1/2 5 5 3 i/: 3 1/2 3 t/2 3 1/2 4 4 4 4 4 1/2 5 5 6 = ' 4 4 1 '2 4 1-2 41 4 l `2 4 l '2 5 6 6 6 -- J : ; ; i i I 4 : 4 ' 5 5 5 5 6 6 6 _ _ ! ' : i ' 5 5 6 6 6 6 6 6 __ 6 6 .6 6 6 :6 16 . 66 6 6 6. 6 _--- , _ -- va- 38 RBB00509 CONDUIT SIZE TABLES TABLE EL LEAD SHEATHED A.V.C. POWER CABLE TABLE CL LEAD SHEATHED A.V.C. LIGHTING WIRE Cable Size 18 16 14 12 10 8 6 5 4 3 2 1 1/0 2/0 3/0 4/0 250 300 550 400 450 500 550 600 650 700 750 800 S50 900 950 1000 1250 1500 1750 2000 Cable Diam, Inches .270 .285 .300 .320 .340 .370 .420 .440 .470 .495 .560 .620 .660 .705 .760 .815 .945 1.000 1.050 1.095 1.140 1.180 1.265 1.300 1.340 1.375 1.405 1.440 1.470 1.500 1.530 1.560 1.770 1.890 2.005 2.110 No. Cables in Conduit i 234 Minimum Size of Conduit 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 l 1 1/4 1 1/4 ! 1/4 I 1/2 1 1/2 1 1/2 1 1/2 2 2 2 2 2 2 'i 2 2 1/2 2 1/2 5 3/4 3/4 3/4 1 1 1 1 1/4 1 1/4 l 1/4 1 1/4 1 1/2 1 1/2 2 2 2 2 1/2 2 1/2 3 3 3 3 3 3 1/2 3 !/2 3 1/2 3 1/2 4 4 4 4 4 4 1/2 5 5 6 6 3/4 3/4 3/4 1 l 1 l 1/4 1 1/4 1 1/4 1 1/4 l 1/2 2 * 2 2 1/2 2 1/2 3 3 3 3 3 1/2 3 1/2 3 1/2 4 4 4 4 4 4' 4 1/2 4 1/2 4 1/2 5 6 6 6 1 2 t i 1 1/4 1 1/4 l 1/4 1 1/2 1 1/2 1 1/2 2 2 2 1/2 2 1/2 2 1/2 3 3 3 1/2 3 1/2 4 4 4 4 1/2 4 \n 4 1/2 4 1/2 5 5 5 5 5 6 6 *_ -- Cable Size 18 16 U 12 10 8 6 5 4 3 2 1 1/0 2/0 3/0 4/0 Cable Duin. Inches .245 .255 .270 .285 .310 .335 .400 .420 .440 .465 .495 .575 .6tQ .650 .695 .745 No. Cables in Conduit `23 Minimum Size of Conduit 4 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 l t 1 1 3/4 3/4 3/4 3/4 3/4 1 i 1 1/4 1 1/4 1 1/4 I 1/4 1 1/2 1 1/2 2 2 2 3/4 3/4 3/4 3/4 1 1 1 1/4 1 1/4 l 1/4 1 1/4 1 1/4 I 1/2 2 2 2 2 3/4 1 1 1 l 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 l 1/2 2 2 2 1/2 2 1/2 2 1/2 COMBINATIONS OF CONDUCTORS TABLE NO. 3 NEC fir Cent Am of Conduit or Tubing Conductors (not lead covered).... Lead*Covered conductors ......... For rewiring existing raceways for increased load where it is im practicable to increase the size of the raceway due to structural conditions .................................... Number of Conductors Over i 2 344 53 31 43 40 40 55 30 40 38 35 60 40 50 50 50 MAXIMUM CABLE DIAMETERS FOR PERMISSIBLE CONDUIT FILL Size Inches 1/2 3/4 1 1 1/4 1 1/2 -> 2 1/2 3 3 1/2 4 4 1/2 5 6 NOT LEAD COVERED No. Cables per Conduit l .450 .598 1..706020 1 i I i -7 .243 .323 .412 .543 ! j ! : 5| .234 .Ml .396 .523 j i l ' i 1.170 I .634 ; .610 i 1.505 1 .814 .783 ( 1.795 1 .9-2 .935 2.232 t 1.206 | 1.161 | 2.585 i 1398 . i 345 : 2.930 i 1.585 [ 1.52-1 ! 3.281 j 1.776 j 1 *06 3.675 4.415 ! 1.9S* t 1910 ; j 2.390 J :.296 i 4 .195 .260 .331 .457 .510 .654 .781 .969 I 123 1.273 1.425 1.596 1.920 lead covered No. Cables per Conduit 1 23 4 .458 .609 .776 1.025 1.195 1.535 1.832 2.275 2.635 2.985 3 345 3.745 4.500 .239 .318 .405 .535 .624 .SOI .956 1.187 1.375 1.559 1.745 1.955 2.350 .225 .300 .382 .505 .588 .755 902 1.120 1.295 1.470 1.646 1.843 2.215 .190 .253 .322 .426 .496 .637 .761 .945 1.094 1.240 1.389 1.555 1.870 REWIRING No. Cables per Conduit * J< .479 .636 .811 1.070 1.248 1.602 1.913 2.375 2.750 3.118' 3.490 3.910 4.700 .276 .367 .468 .618 .721 .925 1.105 1.371 1.588 1.800 2-015 2.257 2.715 .252 335 .427 .564 .658 .844 1.008 1.251 1.450 1.643 1.840 2.060 2.480 .218 .290 .370 .489 .570 .731 .873 1.084 1.255 1.423 1.593 1.784 2.145 RBB 00510 39 CURRENT RATING CORRECTION FACTORS FOR VARIOUS GROUPINGS OF CABLES OR CONDUITS (I. P. C. E. A. PUBLICATION No. P-29-224) These tables list correction factors for the I specific groupings of conduits and cables and are applied to current ratings determined by the NEC Tables on page 37. Simply multiply the current rating by the correction factors for the specific groupings of conduits or cables. Number of Conduits Horizontally Vertically 1 2 5 4 5 6 For Cables In Conduit--Values of K I2 34 1.00 0.94 0 91 0.88 0.92 0.87 0.84 0.81 0.85 0 81 0-78 0.76 0.82 0.78 0.74 0.73 0.80 0 76 0.72 0.71 0.79 0'5 0'1 0.70 5 0.87 0.80 0.75 0.72 0.70 0.69 6 0.86 0.79 0.74 0.72 0.70 0.68 For Cables in Air--Values of K Number of Cables Horizontally 1 2 3 4 5 6 Vertically 1 1.00 0.93 0.87 0.84 0.83 0.82 2 0.89 0.83 0.79 0.76 0.75 0.74 3 0.80 0.76 0.72 0.70 0.69 0.68 4 0.77 0.72 0.68 0.67 0.66 0.65 5 0.75 0.70 0.66 0.65 0.64 0.63 6 0.74 0.69 0.64 0.63 0.62 0.61 Note--Thtif correction terrors apply only when the spool ns brr.s ren caMc oc conduit surfoecs it not em'er thin cable 01 conduit diameter, or !tss than onc-quoncr of COMc nr ronduii dijmetet. Minimum Bending Radii for Roclcbestos Wire* and Cables This catalog shows many standard and "special" Rockbestos wires and cables and be cause both construction and diamercr determine the Bending Radius, information on any specific wire or cable will be furnished on request. 40 RBB 00511 I TERMINAL and JOINT INSULATION FOR A.V.C. CABLE n in general, no special precautions are necessary in the insulating and waterproofing of terminals or joints in A.V.C. cable runs. This is because of the additional ther mal capacity of thermal ends and joints, plus the fact that in general such terminal ends or joints are in cooler ambient locations than the main run of the cable. In this type of location it is common practice to use rubber tape and friction tape as a means of insulation. For large sizes of A.V.C cable where a splice is neces sary, it is advisable to build up the joint with layers of varnished cambric tapes prior to the application of the rubber and friction tapes. In wet locations where lead covered A.V.C. cable is used, the same practice is used except that the friction tape is treated with a glyptal varnish or Irvington oil stop. The illustration below shows a recommendation for such a cable splice. In all high voltage, i.e. over 600 volts, all terminal ends and joints should be insulated with varnished cambric tape before applying the rubber or friction tapes. The friction tape should be treated with either glyptal varnish or Irvington oil stop. Where it is necessary either to terminate or make a joint in a high ambient temperature zone, we recommend that the joint or terminal end be insulated with layers of var nished cambric tapes wrapped with asbestos listing. List ing can be coated with wax or covered overall with friction tape. SUGGESTED METHOD OF SPLICING AVA OR AVL CABLE 1. Prepare cable ends and joint with standard soldered or mechanical connector. 2. Paint connection and adjacent insulation with compound such as glyptal varnish or Irvington Oil Stop. 3. Apply layers of varnished cambric tape with glyptal varnish or Irvington Oil Stop between layers to fill up space even with braid or lead sheath. 4. Apply two layers of rubber tape, and then two more layers of friction tape with glyptal varnish or Irvington Oil Stop between all layers and over surface. Extend rubber and friction tape over at least two inches of the cable sheath or braid which previously had been painted. 3. In case of lead sheathed cable where joint will be in wet location, a lead sheath and wiped joint may be used. RBB 00512 BARE COPPER WIRE DATA ALL DATA TO ASTM B-25B RESISTANCE (BUREAU OF STANDARDS) fl I Size AWG Diiin. faches Circular Mils LBS/1000' FT/LB OHMS/1000' 20C (68F) : : Size AWG 4/0 .460 211.600 640.5 3/0 .410 167.800 507.9 2/0 .365 133.100 402.8 I/O .325 105.600 319.5 1.561 1.968 2.482 3.130 .04901 .06180 .07793 .09827 : VO 5/ 0 ' I/O 1 .289 83.690 253.3 2 .258 66.360 200.9 3 .229 52.620 . 159.3 4 .204 41.740 126.4 3.947 4.977 6.276 7.914 .1239 .1563 .1970 .2485 l -i 3 4 5 .182 33.090 100.2 6 .162 26.240 79.46 7 .144 20.820 63 02 S 128 1^510 49.98 9 .114 13.090 39.6} 10 .102 10.580 31.43 ii .091 8.230 24.92 12 .081 6.530 19.7" 9.980 12.38 15.87 20.01 25.23 3192 40.12 50.59 3133 3951 .4982 .6282 .792! 9989 1.260 1.588 5 6 8 9 10 n 12 13 .072 5.180 15.68 63.80 2.003 13 14 .064 4.110 12.43 80.44 2.525 14 15 .052 3.260 9.858 101.4 3-184 15 jT3 16 .051 2.580 7.818 127.9 4.016 16 17 *045 2.050 6.200 161.3 5 064 r * 18 .040 1.620 4.917 205.4 6 585 18 19 .0}6 1.290 3.899 236.5 8.051 19 20 .032 1,020 3-092 323.4 10.15 :o 21 .028 S12 2.452 407.8 12.80 : 21 22 .025 640 1.945 514.2 16.14 ? 23 .0216 511 1.342 648.4 20 36 1 23 24 .020 404 1.223 817.7 25 67 24 25 .0179 26 .0159 11 .0142 28 .0126 29 .0113 50 .010 31 .0089 32 .0080 33 .oon 34 .0065 33 .0056 36 .00^0 320 253 202 159 I2S 100 79.2 64.0 50.4 59.7 51.4 25 0 .9699 .7692 .6100 .4837 .3836 .3042 .2413 .1913 .1317 .1203 .09542 .07568 1031. 1300. 1639. 2067 2607. 3287. 4145. 5227. 6591. 8310. 10480. 13210. 32.37 4081 51.47 64 90 Si.S3 103.2 130.1 164.1 206.9 260.9 329.0 414.8 ` ` ; 1 25 26 :s 29 30 31 32 33 34 35 36 33 .004 4 20.2 .06001 16660. 525.1 37 38 .0040 1 16.0 .04759 21010. 659.6 38 39 .0035 12.2 .03774 26500. 831.8 39 40 .0031 9.61 .02993 33410. 1049. 40 ! 42 RBB 00513 REL DIMENSIONS -- INCHES Flange (A) .......................................................................................... Traverse (T) ........................................................................................ Drum (B) ............................................................................................ Max. Width <W) ............................................................................... Vol. Cu. Ft............................................................................................. Approx.,, 1-- All Wood ............................................................. Weight f-- Wood-Steel Drum ............................................. 42 12 24 18% 19*1 130 183 48 15 24 21% 29.0 184 48 24 24 joy2 40.6 250 275 60 32 32 4oy2 84.4 500 500 66 32 32 401/j 102 550 j ! i j | i 66 i 36 ! 40 j 45 ! 114 j 650 650 i 72 ; 36 ; 40 < 45 135 790 790 "T 36 4S 45 135 820 820 Cable DiamM Inches .300 .320 MO .360 380 .400 .420 .440 .460 .480 .300 .350 .600 . .630 .700 . o .750 .800 .850 .900 .950 1.00 .. 1.05 .. 1.10 .. 1.15 .. 1.20 .. 1.25 .. 1.30 - MAXIMUM CAPACITY FOR SOLID COVDt.'CTOR OR LEADED CABLE 1.35 1.40 1.45 1.30 1.55 1.60 1-65 1.70 1.75 . . . . . . . . NOTES: 1. Clearance (X) meets IPCEA Standards on .300" diameter and over. 2. Use max. dia. of cable to determine reel site. 3. All capacities shown in this table meet a recommended drum diameter (B) equal to 14 times the cable diameter. For all leaded and solid conductor AVA cables, the recommended drum diameters (B) are IS times the cable diameter--see above solid line. 4. All reels with leaded cables (30" flange and larger) to be wood lagged. Lagging adds the following to reel weight: Size Reel Wgt. of Lagging Lbs. Size Reel Wgt of Lagging Lbs. 42x12 48x15 48x24 80 90 101 60x32 66x32 66x36 72x36 210 240 270 300 8080 7190 6300 5670 4990 Recommended Maximum Capacity--Feet Per Reel 10714 9938 4530 4100 3710 3460 3170 2890 2410 1980 1680 1450 1120 976 891 777 716 629 582 543 8883 8129 7447 6682 6133 5670 4691 3910 3360 2840 2490 2170 1910 1760 1560 1380 1260 1140 1060 9070 7500 6260 5380 4540 3980 3470 3060 2810 2490 2210 2050 1820 1700 9630 8490 7250 6440 5730 5090 4730 4224 3770 3540 9810 8300 7460 6700 6000 5360 5190 4630 X -- Clearance between top layer of cable and flange edge. 9590 7800 6940 6130 ! [ 5680 5100 4560 4250 8370 7540 6790 6310 5710 8980 7950 7220 6420 5740 5270 4750 4580 477 946 1510 445 888 1420 418 841 1350 394 747 1190 345 706 1130 326 672 1070 308 594 949 292 565 905 278 541 864 262 516 825 231 456 728 Cable Diam., Inches 1.80 1.85 1.90 2.00 2.10 2.20 i.JU 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3180 2990 2690 2540 2400 2160 2050 1950 1760 1670 1600 1530 1370 1320 1270 1090 1010 938 4110 3990 3530 3440 3020 2950 2570 2510 2460 2120 2080 2040 1740 1710 1680 1390 1350 noo 3810 3550 3200 3020 2340 2570 2420 2300 2190 1970 1880 1800 5170 4850 4400 4150 3770 3580 3400 3070 2930 2650 2540 2430 1710 1550 1480 1360 1260 1090 1010 941 880 762 714 671 2360 2110 2030 1870 1630 1520 1420 1230 1160 1090 1030 894 3950 3670 3440 3120 2920 2750 2490 2360 2230 2120 1920 1830 1740 1660 1590 1380 1260 1170 1080 941 874 818 764 718 625 588 ! RBB 00514 43