Document ZJZ9VenXQO0ZqGE72GoEpr4Md
DOW CHEMICAL U.S.A.
June 23, 1978
LOUISIANA DIVISION PLAQUIMIN1. LOUISIANA 707S4
04 SSS-S000
All CPE Plant Employees and Laborers
cc: Betfy Doughty \P<"E. Halphen A. J. Seidule R. G. Vaughn
CARBON MONOXIDE STUDY AT CPE
On May 19, 1978, a study of the carbon monoxide levels which CPE personnel may be exposed to was completed using the Model 31 Draeger pump with tubes. The only reading that exceeded the OSHA threshold of 50 ppm was obtained when a fork lift went up toward the front of the trailer, and the Draeger pump was about 6 feet away from the exhaust
Carbon monoxide will build up in an enclosed area such as a van or trailer, therefore, we must not leave the fork lift running under these conditions.
We do not appear to have a problem with over-exposure to carbon monoxide in the CPE Plant.
Attached is a copy of the study.
R. S. Fileccia CPE Environmental Health
shw
attachment
AfHAQ//
AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY
CARBON MONOXIDE STUDY May 19, 1978
Instrument: Model 31 Draeger Pump
Location Warehouse Warehouse In trailer (front)
In trailer (middle) In trailer (middle
to back) In trailer (near
back end)
Details
No fork lift running
Fork lift running
After fork lift had made four trips into trailer with pump approx. 6' from exhaust
Large fork lift
Large fork lift
Results (ppm)
2 10
10 - 70
AO 20 - 30
Large fork lift
10 - 15
R. S. Fileccia 6-23-78
shw
00 A 117.18 CONFIDCNTTA