Document ZJ5kB9p5ke3QM0YdmQepV6YKV
jMI
WORLD HEALTH ORGANIZATION
INTERNATIONAL AGENCY FOR RESEARCH ON CANCER
OF ASBESTOS ^
Proceedings of a Working Conference held at me international Agency for Research on Cancer,
Lyon, France, 2-6 October 1972
P. BOGOVSICI V. TIMBRELL
EDITORS
J. C. GILSON J. C. .WAGNER
TECHNICAL EDITOR FOR IARC
W. DAVIS
IARC Scientific Publications No. 8
INTERNATIONAL AGENCY FOR RESEARCH ON CANCER LYON 1973
ASARCO ALV 0007302
no BIOLOGICAL ErrKCTS Or ASBESTOS
able instrument, all the dust samplers available at the time have been tried and discarded for one reason or another (Holmes, 1965). Instruments based on impingement tended to break up the fibre bundles; and those based of thermal precipitation (except the long-running precipitator) appeared to be very inefficient collectors of the longer fibres. Eventually, the membrane filter method was chosen as the most likely system of sampling for asbestos fibres, and de velopment of this method proceeded both in the UK and the USA.
The principle of the method is that the dust sample is collected on a cellulose membrane filter of fine pore size. The filter is subsequently mounted on a microscope slide and cleared (i.c., rendered trans parent) with a liquid whose refractive index is such that the contrast between the fibres and the back ground is not impaired. The sample is then counted at a magnification of about 500 x , and to further en hance the visibility of the fibres a phase contrast microscope is used.
For the purpose of analysis, a particle is defined as a fibre if its length is at least three times its diameter andjf it is at least 5 micrometres in lengtn. In audi tion, in the UK it is customary to set 3 pm as an upper limit on the diameter, on the grounds that fibres of larger diameter than this would not be re spirable. The method has the great advantage that asbestos fibres arc easily recognised and this is essen tial where mixed dust is involved. The lower length limit of 5 pm was chosen somewhat arbitrarily in the early days of the development of the method; how ever it is significant that fibres which are retained for long periods, either free or as the cores of asbestos bodies, in the lungs of occupationally exposed per sons arc generally longer than this.
The Dust Measurement Working Group of the Asbestosis Sub-Committee of the Permanent Com mission has recommended the membrane filter method for acceptance as the standard method for assessing occupational exposure to asbestos, and measurements based on the method were used by the British Occupational Hygiene Society (196S) for the formulation of its hygiene standard for chrysotile asbestos dust. Government controls on asbestos dust emission in both the UK and USA are also ex pressed in terms of fibre counts, to be measured in the same way.
The membrane filter method possesses one im portant disadvantage in that the mounting and count ing of the sample is a somewhat tedious operation.
Means of speeding-up the work have been sought, and over the last few years the UK industry has made good use of an American instrument, the Royco Automatic Particle Counter, for routine measure ments in situations such as textile factories where the dust is almost entirely asbestos. This has been made possible because, while the Royco instrument de pends for its functioning on light-scattering and therefore "sees" all dust particles which pass through it, its size-discrimination facility can be adjusted to give the same numerical reading as would be obtained from a membrane filter sample taken in the same place and at the same time. It is also fitted with an automatic print-out device, thus the necessary in formation is provided simply and quickly without the tedium of mounting the sample and counting fibres under the microscope.
While the Royco continues to be used for routine factorv monitoring and engineering controls, it is not suitable for biological studies, in which personal sampling is preferable; for this the membrane filter method is ideal, being extiemely portable. Epide miological studies already planned will involve the ccllccticr. ?."'1 'naivete of force numbers of mem brane samples, and this has led to a search for an instrument which will automatically count and sizeselect fibres directly from the microscope slide. Among a number of instruments already examined, the Quantimet 720 (1MANCO Ltd) is showing par ticular promise. Using a phase contrast microscope system with automatic focusing, the Quantimet should be able to deal with an automatically fed magazine load of microscope slides. As might be expected, the cost of such a system is likely to be considerable and could only be justified where large numbers of samples are involved.
The membrane filter method can be criticised on the grounds that very fine asbestos fibres may not be seen in the light microscope, even under the best viewing conditions. The investigation of alternative methods of analysis, usually based on mass estima tion, is not being neglected, in spite of the difficulties associated with asbestos referred to above. Methods so far tried include atomic absorption spectroscopy (by which the magnesium in chrysotile can be esti mated) and infra-red analysis. The most promising method explored so far, however, is based on X-ray diffraction, where even in a mixed dust sample the asbestos can be specifically identified by its crystal structure. Using an X-ray diffractometer it is pos sible to measure as Iitltc as 10 nticrograms of chryso-
ASARCO ALV 0007304
i sought, nas made e Royco mcasurevhcrc the een made ment dering and s through ljusted to obtained the same d with an :ssary in' without counting
it routine s, it is not personal -ane filter . Epidevolve *he ol > ch loi an and sizc>pc slide, examined, wing particroseopc ^uanlimet tically fed might be rely to bo here large
iticiscd on tay not be r the best alternative iss cstimadifficulties
Methods ectroscopy an be cstipromising 1 on X-ray sample the its crystal r it is posofr' -.<>
SAMPU.S'G METHODS
111
tile asbestos in a sample where the asbestos repre method has been used; but in many of the samples
sents perhaps only 10% of the total mass.
collected, no asbestos has been detected by this method. In these cases, it has been necessary to
treat the sample by ultra-sound to disperse any as
ENVIRONMCs
&SBESTOS
bestos present into its basic fibril form and to
estimate the mass using transmission electron micros
In .n?ccnt years there has been considcrat copy. This method, which is shortly to be pub
SDetfulalion concerning asbestos as a public health lished, can measure asbestos concentrations as low as
nazard in view of its widespread usage in a variety of 10V grams per cubic metre in a 1000 cubic metre
forms, including brake linings, in spite of the fact samme, even in the presence of excessive amounts of that for the latter application it has been shown that othcJ airborne solids.
due to heat degradation the wear products which are THS sum up, the combination of membrane filter
generated contain little fibrous asbestos. The emis sampling and optical microscope analysis is still con
sion of dust from plants manufacturing asbestos, sidered to be the best system for monitoring asbestos
iducts has also been mentioned as a poteplitflfy dust in occupational situations. Mass estimation
danpcm?Trsr>wcn.nf pollution
methods have the great advantage of rapidity, but
The asbestos industry in the UK has therefore felt they cannot be adopted with confidence, particularly
obliged to investigate the position, and it has in for chrysotilc, until a reliable clutriation system is
stituted a programme of mcasurcmei ' in the vicinity available. Furthermore, because of the belief that
of its factories, and in selected v' :-.n and rural the longer fibres may be of special significance as re
situations. It was quickly demons!: -.ed that asbes gards a health hazard, a technique for sizing and
tos, if it was present at all, existed in such small counting of fibres must be considered important.
quantities that the standard sampling instruments On the other hand, for assessing the asbestos con-
<1I1U illCUlUU^ WCIC lUililsivlvijr
TO CbtllT. ten4 Cr
atmAsnhprr?
-any measurable quantity of asbestos, it was ob estimation is the only available method. In this type
viously going to be necessary to sample very large of study the question of elutriation docs not arise,
volumes of air, and if this was to be collected in a since it can be confidently assumed that all the fibres
reasonable time, a high speed sampling instrument which remain airborne in these circumstances will be
would be necessary. Such an instrument is the respirable. The concentrations of asbestos seen un
Litton Sampler (Rickards & Badami, 1971) which der these conditions arc so small that large volumes
works on the principle of electrostatic precipitation of air have to be sampled; however, here high-speed
and is capable of sampling speeds of up to 10,000 samplers can be used, which is not the case for occu
litres of air per minute. This means that sample pational situations. The fibres collected arc gener
volumes of a million litres (1000 cubic metres) can be ally too fine to be seen under the light microscope,
collected in a reasonable lime.
particularly in the presence of a high concentration
Even in these large volume samples, estimation of of other atmospheric pollutants. Estimation of the
the asbestos load has proved difficult. Where the asbestos content has therefore to be made on a mass
total mass is above about 100 mierograms (i.c., basis using X-ray diffraction or electron microscopy,
10"' grams per cubic metre) the X-ray diffraction depending upon the quantity collected in the sample.
SUMMARY
The special ptoblems associated with the sampling and analysis of fibrous dusts are discussed. The merits and dis advantages of sampling methods based on fibre counting and mass determination are reviewed in relation to sampling in both occupational and general environmental situations.
REFERENCES
British Occupational Hygiene Society (1968) Hygiene Holmes, S. (1965) Development in dust sampling and
standards for chrysotilc asbestos dust. Annals ofOccn- counting techniques in the asbestos industry. Annuls of
palional Hygiene, II, 47-69
the Hew Ymk Academy ofSciences, 132, 28S-297
ASARCO ALV 0007305
112 BIOLOGICAL EI'IECTS OF ASBESTOS
Rickards A. L. & Hadami, D. V. (1971) Chrysotile asbestos in urban air. Suture {London), 234,93-94
Timbre!!, V. (1970) Inhalation of fibres. In: Shapiro, II. A., cd., Pneumoconiosis. Proceedings of the Inter national Conference, Johannesburg, 1969, Cape Town, Oxford University Press, pp. 3-9
Timbrel!, V. (1972) An aerosol spectrometer and its applications. In: Mercer, T. T., Morrow, I*. E. & Stober, W,, cds., Assessment of Ah borne Particles. Proceedings of the Third Rochester International Con
ference on Environmental Toxicity, Rochester, 1970, Springfield, Charles C. Thomas, pp. 290-330
Timbrcll, V. & Holmes, S. (1970) Suggestions on criteria for sampling asbestos dust. In: Shapiro, H. A., cd., Pneumoconiosis. Proceedings of the International Con ference, Johannesburg, 1969, Cape Town, Oxford Uni versity Press, pp. 610-612
Vorwald, A. J., Durban, T. M. & Pratt, P. C. (1951) Ex perimental studies of asbeslosis. Archives ofIndustrial Hygiene, 3, 1-43
iy 4.
*- V
ASARCO ALV
nr-ft:
0007306