CHAPTER 18
1962 Guide And Data Book
safely be taken as being in the range of 0-32 to 0.38 cu ft per (hr) (lb) of body weight. The heat emission by livestock also varies with the species, and with the rise, activity, and >*, It is in the range of 2.4 to 8 Btuh for mammals and 5 to 14 Btuh for birds per pound of body weight.
The factors discussed here apply to an all-cargo airplane as well, but there, of course, primary consideration can be given to cargo requirements without concern for personnel comfort other than the crew. Cargo airplanes may also be equipped with refrigeration to transport such goods as fresh meat, fruit, or frozen foods. The entire cargo area may be refrigerated, or provisions may be made for transporting individually re frigerated containers.
SUPERSONIC TRANSPORTS
The problems of air conditioning airplanes at high subsonic speeds are compounded by the higher ram air and Vin tem peratures encountered at supersonic speeds. As the tem perature of.the ram air increases in the supersonic range, ft is eventually lost as a heat sink and other suitable sinks must be found. Relatively small supersonic military craft have been successfully air conditioned, but the cooling load of a large passenger capacity transport will be much higher and the comfort requirements more exacting. An extension of the state of the art in many areas will be required.
The cooling load should first be reduced to a practicable minimum by the use of insulation anrl recirculation of all cabin air except that required to maintain pressurization. If the re circulated air is properly filtered, the makeup of.cabin leakage should provide adequate fresh air. Heat intercept methoda, where the cabin air is forced out of the cabin uniformly through a porous inner lining to absorb heat at the Hn, may
have some merit. Plating or coating of the airplane lrin with a material to decrease the amount of heat absorbed should also be considered.
The fuel carried by the airplane is a possible heat rink with the heat rejected by the air-conditioning system bong used to pre-heat the fuel before it. is burned in the engines. Thi3 sink has undesirable limitations in that the quantity of fuel is vari able, tire temperature of the fuel must be limited to a safe value dependent on auto-ignition temperature and pumping considerations, and the fuel will absorb ram air heat which may necessitate pre-chilling before flight, innkt->n of the fuel tanks, or both. An alternate heat rink is the use of an evaporative fluid such as water or ammonia This would prob ably be heavier, at least on take-off, than the fuel heat sink method.
The high ram pressure increase at supersonic speeds offers some advantage in that little or no additional pressure in crease may be required to maintain an adequate cabin pressure, depending upon the operating speeds and altitudes.
The actual cooling equipment may be quite conventional, with vapor-cycle systems appearing to be the most promising at this time. The systems may be cascaded, and the use of an air-cycle system in series may offer some advantage in cooling the pressurization air. The greatest complication and refine ment will probably have to be in the control systems. The ro tating machinery will probably be required to operate in ex tremely high ambient temperatures, which will introduce special bearing and lubrication problems. . Vortex tubes and thermoelectric devices may be used for dissipating small localised heat loads where their unique char acteristics may be used to.advantage. Presently, endothermic reactions do not appear to offer anything, but they may be worthy of further consideration in the future.
CHAPTER 19
MARINE AIR CONDITIONING
Onerof Desian Requirement*. Design Temperature*. Yan&athn Requirements, toad DeSsnainction, ujyipflieiii Selection, Sheer Mefaf Ducts, Typical Systems, Air Distribution Methods, Controls, Regulatory Agencies
IR conditioning of merchant vessels prior to World liners frequently make off-season onuses during which more
At War II was limited to but a few of the better known severe heating and cooling loads may be encountered. The passenger liners. Since.the war, practically every new passen selection of the ambient design should be based upon the
ger vessel and converted passenger vessels, with few excep temperatures prevalent during the voyage. In general, for the
tions here and abroad, provide air conditioning for both cooling cycle, outdoor design conditions for North Atlantic
pa&engers and crew in all living accommodations. The most runs are 95 F dry-bulb and 78 F wet-bulb; for semi-tropical
significant recent trend has been the air conditioning of ^rioting as well as new tankers and cargo vessels of all types.
runs 95 F dry-bulb and 80 F wet-bulb, and for tropical runs 95 F dry-bulb and 82 F wet-bulb. For the heating cycle, 0 F
The principal reasons for this increased interest in marine
air conditioning are:
1. To safeguard against early obsolescence of the vessel. 2. To increase crew efficiency, particularly during operation in the tropics. 3. To attract and hold better qualified crews. 4. In new construction, to avoid long lay-up for adding air fOTtwtitinning at a later date.
is usually used as the design conditions unless it is definitely known that the vessel will always operate in higher tempera
ture climates. Effective temperatures from 71 to 74 ET generally are se
lected as inside design conditions for the cooling cycle for passenger and cargo ships. Tankers and non-passenger ships have been designed for 76 ET to 78 ET for crews' quarters, although the trend now is toward greater comfort with lower
This chapter will cover the air conditioning applicable for effective temperatures.
aQ ocean going vessels whether they be the super luxury liners
Public spaces and passenger staterooms are designed for
or the tramp steamer. The broad general principles of air con 76-80 F dry bulb and from 45-50 percent relative humidity
ditioning which apply to land installations are applicable to for summer and 70-75 dry bulb for winter. Crews' quarters
marine, provided ail of the factors affecting the construction aboard tankers and cargo vessels can be designed for 80-85 F
and operation of a ship are afforded proper consideration.
with 40-50 percent relative humidity. Consideration in the
design of the air-conditioning system should'be given to main
GENERAL DESIGN REQUIREMENTS
taining more comfortable room conditions during inter
Factors to be considered in the design of an air-conditioning system for shipboard are as follows:
mediate outside ambient conditions. Quality systems are de
signed to provide optimum comfort when outdoor ambient
conditions of 65-75 F dry bulb
90-100 percent relative
l. The system should be designed to function properly under
conditions of roll and pitch to which a ship is normally subjected. 2. The materials of construction should be suitable to with
stand thecorrosive effects of sea air and water. 3. The system hnntH be designed for uninterrupted operation
humidity exist, and to insure that proper humidity and tem perature levels are maintained during periods when sensible loads are light. The latter is very important because of large variations in sensible loads (solar, lights and people) in spaces
during the voyage and continuously all year round. Sint* ships
en route cannotbe eerily serviced, some standby capacity, spare
parts of all
items, and extra refrigerant charges should
be carried. The system whradri be designed so that there will be no ob
jectionable noise or vibration. Although the ship's engines and
* auxiliaries may mask the noise and vibration of the air condi
tioning systems while in voyage, it must be realized that the main
engines many, auxiliaries are shut down while the ship is in
port *nd that the noise level under port conditions must be within
the acceptable limits established for land practice.
5. In view of the high premium for space on shipboard, the
equipment-should be deigned to occupy a minimum of space
commensurate with cost and reliability. Weight should be held
to a mimrmjTn
6. Since a ship may pp" through one or more complete cycles
. of seasons on a single voyage, and experience a change from
winter operation to summer operation in a period of Bays or
oren hours, the system should be designed to provide the neces
sary flexibility to compensate for these climatic changes with a
minimum of necessary attention by the ship's operating
personnel.
throughout a vessel.
Ventilation Requirements
In staterooms and cabins a minimum of 12^ to 15 cfm outdoor air per person for recirculation systems is supplied and where all primary air is employed, higher cur quantities (25 cfm per person or more) are recommended for adequate purging. Specifications often require a minimum of 40 cfm total air to be supplied regardless of the size of the space. In no event should the outside cur be less than a 30-min air change. In public spaces, mess rooms, lounges and other spaces of relatively high occupancy the outdoor air require ments should provide a minimum of 10 cfm per person. Toilet spaces within air-conditioned areas are provided with an exhaust which will change the air at least 10 times per hour or a minimum of 35 cfm, whichever is the greater, fifteen-air changes are used where it can be achieved without penalizing the refrigeration load. Some shipowners prefer higher quan
Ambient and Indoor Temperature
tities of outside air which of course result in higher air-con ditioning loads. Automatic damper controls frequently are
In determining the proper outdoor design temperatures, provided to increase the amount of outdoor air when outside
consideration should be given to the-intended service and conditions are such that it can be done without overloading
type of the vessel. In addition to their regular itinerary, many the plant. Of course, under favorable conditions the cooling