Document ZELRaznrp295oNNV0xj19zBd
926
CHAPTER 41
1954 Guide
found that for 360 rpm the static deflection required for. a ratio of ///,, of 3 to 1 (line EF) is 2.5 in., and for a ratio of 5 to 1 (line GH) it is 7 in. For these values of deflection the only choice of material is the coil spring. This is also true for speeds up to about 700 rpm. In consideration of the transverse spring constant (so as to maintain good ratios among the various degrees of freedom) experience has shown that the spring should be designed with a working height equal to 1.0 to 1.5 times the outside diameter. A long spring of small outside; diameter has very 'low transverse rigidity, and therefore requires some`additional means of preventing side drift of the unit, and on very sensitive applications this may tend to destroy the isola tion efficiency. For speeds of 700 to 1200 rpm the required deflections range from 0.22 in. to 1.75 in.: For these conditions rubber in shear serves as a rather satisfactory material if protected from oil. For speeds higher than 1200 rpm cork specially made for vibration damping can be applied with good results. These limitations are by no means absolute, because certain liberties may be taken without impairing the result if all possible degrees of freedom have been taken into account in the design of the installation.
When a machine unit is properly isolated it will have a definite amount of movement which is determined by the ratio of the unbalanced forces to the total mass of the machine. If this resultant machine movement is too great for the necessary connections or the satisfaction of the customer, it can be reduced only in two ways without destroying the quality of the isolation; first, adding mass or dead weight to the machine (such as concrete) common in the application of low speed, partially balanced machinery; second, accurately balancing (both statically and dynamically) all moving parts so as to eliminate the vibration at the source. This latter method is the best engineering practice and is the modem trend. However, even with well balanced machinery, installed in the vicinity of quiet offices, it is usually necessary to isolate properly the equipment to, prevent the transmission of
vibration likely to cause complaints.
Where limitation of machine movement is desired during the starting and stopping periods, the. application of friction or hydraulic damping will.serve without seriously interfering with the efficiency of the isolation.
REFERENCES
1 American.Standard for Noise Measurement, Z24.2-1942, American Standards Association. * American Standard for Sound Level Meter* for Measurement of Noise and Other Sounds, Z24.3-1944,
Am9eSricoaunndSItnansdualardtisonAsosfoWciaatliloann. d Floor Constructions (U. S. Department of Commerce, NationalBureau of
Standards, Building Materials and Structures Report BMS17 and Supplement). : 4 A.S.H.V.E. Research Report No. 1205--Determining Sound Attenuation in Air Conditioning Sys tems, by D. A. Wilbur and R.,F. Simons (A.S.H.V.E. Transactions, Vol. 48, 1042, p. 267).
* For coefficients of commercial-sound absorbent materials see Bulletin Acoustical Materials Association,
019 No. Michigan Ave., Chicago, 111. * SoundPropagation inDucts Lined with Absorbing Materials, by L. J. Sivian (Journal Acoustical Society
of America, Vol. 9, 1937-38, pp. 135-140). 1 The Absorption of Noise in Ventilating Ducts, by Hale J. Sabine (Journal Acoustical Society of America,
Vol*. S12o,upn.d5A3.b1s9o4r0p)t.ion in Rectangular Ducts, by L. L. Beranek (Journal Acoustical Society of America, Vol.
12, *ppT.h2e2T8-r3a7n,sOmcistosbioenr,o1f9S40o)u. nd Inside Pipes, by Philip M. Morse (Journal Acoustical Society of America,
Vol.181T1h, eppP.r2e0d5i-c2t1io0n, Oocf'tNoobiesre, 1L9e3v9e) ls from Mechanical Equipment, by J. S. Parkinson (Heating and vents.-
lating, March. 1939, pp. 23-26).
' . .t_ _t n.u.. .V. XT-:.
Equipment, by J. S. Parkinson (A.S.H.VJ3.
Stewart'and G. F. Drake (AS.H.V.E. TbaJ-
! ''Vi":A:-KJ
CHAPTER 42
ELECTRIC HEATING
Resistors, Heating Elements,.Elec,tric.Heating Units, Applications of Electric Heat, Types of Electric Heating Systems, Equipment and Installation Methods, Calculating Capacities, Heating Water by Electricity, Induction , and Dielectric Heating, Power Problems
ELECTRICITY as a source of heat represents thermal-energyiin a re^ fined form, easily applied to space heating by a variety'of-methods; and readily distributed and controlled. However, it'usually is more1 expensive on a direct-heat-equivalent basis than heat from conventional fuels, and for economical service requires careful application in the design of system; adaptation of building structure, choice of control devices, and in method of operation by the user. For special, applications and. particularly when used to supplement heating-, systems, of other types,: The compactness, simplicity*: responsiveness, accuracy, of control, safety;.and other charac teristics of electric heating may carry greater weight in ehoice of method; than operating expense or initial investment.
The basis of all electric heating methods and'devices, except so-called heat pumps, is in the power-toTieat'conversion constant: ! kilowatt equals 3413 Btu per hr: Because ratings'of electric heating^equipinent are ex pressed in terms of watts'input and volts at the .terminals, heating capacity calculations'are translated directly to electric power requirements without the necessity of considering ampere currents or ohm resistances.
Definitions of Resistor, Healing Element;'Electric 'Hehting UnitAnd other terms applying to heating practices will -be found in Chapter 1.
It is strongjy recommended that compliance with the National Electrical Code and approval by Underwriters' Laboratories Inc., or other recog nized certifying agency, be required in the specifications for 'all equipment; materials, and construction-used .in electric heating systems.
RESISTORS AND HEATING ELEMENTS :A -
Electric resistors usually are composed of metal'alloys'such as nickelchromium wire or ribbon, or rion-metallic compounds containing carbon formed into rods or other shapes. Heating elements may. have resistors either in the form of exposed coils'mounted on insulators or! of metallic conductors embedded in a refractory insulating material, 'encased in a protective sheath of metal,.. Fins or extended surfaces may be used to add heat-dissipating area. Elements are made iii many forms, such as wires, strips, rings, tubes, plates and panels. Strip elements are used for clamping to surfaces requiring heat transfer by conduction, in some types of con vection air heaters; and in low-temperature radiant heaters; Ring and plate elements are common in electric ranges and' many small air heaters: Metal or oxide conductive films on glass and ceramics have been applied, usually in the form of panels. Tubular elements may be immersed in liq uids, and when cast into metal or formed into coils,1 are used in water heaters, electric ranges and air heaters.
Cloth fabrics, woven from flexible resistor wires and'asbestos or glass
927