Document ZBpZ8g0Vz3308a3VGpOXx3nEO

r K DIRECTIONS FOR TEST HO. 14-89-41 SUBJECT: Water Content of Liquid Aroclors ' METHOD:'" Titration 'irtWshrl'TlWher Reagent' "item,. .......... I i^Sp^Lred l|^4;^ture antf^tT^aol ilbletftS*'' beehti^ratedwithJ^ tiachaTactorlatic end poi&t. Fischer reagent is a solution of iodine, sulfur dioxide, and pyridine* Iodine is oonsuasd as long as any water is present, v The solution is again titrated to obtain the water content intro- : duced by the Aroclor. r ' : Solutions and Apparatus Earl Fischer Reagent: Heigh into a flash 64 grams of pyridine* Barrett 2-A-or Eastman 21and add 61 grams of'li2uid sulfurv di-- oxide. Add the sulfur dioxide direct!^from the inverted cylinder * by attaching to the outlet valve a glass tube extending into the pyrldine. Store in a glass stoppered bottle. Transfer 65.6 grams of the pyridine-602 mixture and 134 ee of absolute methanol to a 1 liter Florence flask. Cool thoroughly in an ice water bath. Add 15.9 grams of iodine, stopper, cool again before shaking. Alternately cool and swirl until the iodine is in solution* Hakes 200 ec* of reagent* Store in glass stoppered bottle* Let stand 24 hours before using* When fresh, one cc* of reagent is equivalent to about 0.0033 gms. of water. '. VAr'o"clo"*r Solve\nt:% lE/Lx 2 p'aS rts dry benzol with 1 part absolute ,f methanol* The dry benzol is prepared by shaking the commercial grade . with anhydrous calcium chloride, decanting into a flask and distilling, rejecting the first 1Q$ to come over. Keep in glass stoppered bottles with minimum exposure to air* . ::: /- -v Micro Buret: 10 ee. x 0.05 cc* Ebch automatic'with glass stop-- pored reservoir. Xck and Krebs #2460. Equip reservoir with a moisture guard tube. .. : ^ _ . ,,j^l-^'Peat a.clean 500 _ f- Procedure co^narrow mouth erlerimeyer inanbvan open ,fWi;ff biot plate until thoroughly dry. Cool in desiccator* . Sweep out for 10 minutes with air which has been thoroughly dried by passing thru; ; tubes containing .8 mesh drierite. Disengage the flask from the as pirating train and immediately close with a paper cap held by a rub ber band. Without delay, transfer 90 cc. of the benzene-methanol solvent to the flask thru a small hole punctured into the paper cap. Titrate at once with Earl Fischer reagent to a distinct red--'brown end point DSW 330723 STLCOPCB4077367 Page Ho* Z Test Ho* 14-69--41 -- Hater content of liquid Aroclors js which does not fade after swirling several times* - The Pisoher rear gent is diepensed fro the microburet the tip of which projects into, the flash thru the puncture in the paper cap* At the end point sBjr [Hater bo5jsitaentof the',solvent has'^eltjrj^acted^^fupetiapose. Afresh" ' ' "' Obtain Weight of the solvent and well-^covered flash on a Torsion .' balance or equivalent" Quickly introduce about 100 grams of the siightly wanted Aroclor to be tested. Cover at onee and weigh again to ob-- tain the Weight of Aroclor to nearest gram* Shake until the Aroclor is dissolved* If the mixture is cloudy, warm slightly* If cloudiness persists another mixture should be prepared* . r . .v Puncture a small hole %::rl in the'paper bap for the Insertion of the buret tip and titrate with Pischer reagent to the first definite brown color, agitating with a gentle swirling motion* The end point should persist through several swirls* The end point may slowly fade through slow access of atmospheric moisture in which case it is restored by a drop or two of reagent* If not so restored, the end point may have been a false one or the closure is faulty* A definite end point is Impossible if humid air is not well excluded* - Prom the amount of reagent required jand the weight of Aroclor used, calculate the water content in p*p*m* :'5j * ' 5v I : f?Wll \ Example* jIf 1*05 cc* of reagent, 1 ec. of which is equivalent .. to 3360 micrograms of water, is required in the titration of 100 grams of Aroclor, the water content is (1*05 x 3360)/l00 - 35 pop*m* Calibration of Pischer Reagent ' Standard wqter solution in methanol: Transfer exactly 0.40 cc* of water from a micro buret or a 1 ce. measuring plpet to a 100 ce* volumetric flask* Pill to the mark at once with anhydrous methanol and six* 0ns ec* of solution then contains 4000 mlcrograms of water . It* addition to aay water which may he present in the ,methanol* >,'/ ;WM tK'-& , 00- ^>^1^ansfer*.WxactIy *5 cc* of the abpv4 standard water solution' - (equivalent to 0,0S grams water) to a S5^ cc* erlenmeyer which has f been dried end swept with dry air* ' Close with paper cap and titrate with Pischer reagent In the same manner as the sample. The end point is sharp* A methanol blank, found by titrating 5 cc* of the methanol used in making up the standard water solution to a like end point, must always be subtracted from this titration* Divide the amount of water taken by the net Pischer reagent re quired to obtain the titer of the Pischer reagent in terms of water0 DSW 330724 STLCOPCB4077368 r ) I Page No* 3 Test No* 14-89-41 -- Water Content of Liquid Aroclor .... ^Example* ,.rA 5 vqc* ..aliquot .Of standard solution, equivalent to 20,000 nicrograms Of...water, required .6*61 ee# of Fischer reagent while 5 oo* 6t, themethanol required 0*55* of, Fischer reagent* ,, ' * '....... '* '* ' ^J^OO aisp^itte wate# ;n " Recaltbrations: _B_ec. a..us*e***t*h*:e* Flseherreagen t,s deterioratesra- pidly, its titer must be determined for each days use* If the same standard water solution is used inrecalibration as in the initial calibration, the titer Of the Fischer reagent must be calculated from its total water content (including that introduced by the methanol)* The total water is the product of the initial gross titration and its titer* Thus in the example above the total water content of a 5 ce* aliquot is 6*61 z 3300 21813 miorograms* If on recalibration 7*37 cc* of. Fischerr reagent is required per 5 ce* aliquot , the new titer of the'reagent is 21813/7*37 2960 micrograis of Water per cc*; ... 'V .. a. Two or more calibrations should be nade with agreement within 0*025 cc* ................. Water Content vs* Dielectric Strength The General Electric Company has supplied the following correla-- tion* Water Content K Dielectric Strength PP*m* b^ weight %) ET at 25*C* ----------55----------- ' * 34 t, : .; 60 15 The water contents were doubtless obtained by their cloud point test* Because of the minute amounts of water involved, saiqpling methods and containers are Important* Sampling methods for the water deter mination must meet essentially the same requirements as for dielectric strength which are given under AS*T*K* D117-86* . S 11 For sampling^ =bnl^;thoroughly; dfied These} must 4>e quickly .tightly eTosedvand containers the^jfcffisr should opened be used* only when I^K ^.ne.cessary ^ ~ /y . 'Fischer, Earl^Angew* Cham* 48, 394--6 Mitchell, John, I*E.C., Anal* Ed* 12, 390-1 (1940)* Almy, Griffin and Wilcox, I.E.C., Anal. Ed* 12, 392-6 (1940). Reagents, preparation of samples, applicability, interferences, accuracy, stability of reagent, stoichiometry, potenticmetric means, etc* Wiegand, M* J* Letter 6-4-41 giving St* Louis method* ABS-p DSW 330725 STLCOPCB4077369