Document ZBbaaB2bGY1BJN81oBDMa0OB0

PLAINTIFF'S I EXHIBIT DPP-577 GRACE Conitruction Product* Divmon v% R G'oct S Cc 62 WKit,*--Of* Avtnut Cotienejc, v.;ss C2!*: 1617. 876- UOC January 25, 157? t Mr. Don McCrae E. I. DuPont & Co. P. 0. Box 1378 Louisville, Kentucky 40202 Dear Mr. McCrae: Attached is a copy of our Material Safety Data Sheet on Industrial Vermiculite #1 size. As stated in the M.S.D.S., in dustrial end-users of this material should determine for themselves, whether they are in compliance with OSHA Regulation 1910.1001 with regard to in-plant exposure to airborne asbestos fibers. It has generally been our experience that where appropriate industrial hygiene practices are followed, exposures are well within the OSHA limits. Should you elect to make such an in-plant survey, we would be interested in knowing what your results were. This kind of enduse input permits us to assemble a picture of end-use exposures with the product as we are presently controlling. Very truly yours RCE:M Attachment Quality Assurance Manager Construction Products Division /ms*. 51 / DUP 1121655 SB Bl | Z\~Z: "-~e --,7 L.i. - -' ;. Crcupation.i S=-=r/ crc Lh Al 'ir.,itrr:.cn MATERIAL SAFE!'/ DATA SHEET Required under USOL S<>e*v end Htjirh Regulation! for Snip Repairing Shipbuilding. and $hipDrkir.g (23 CFR 1015. 1916, 1917) MANUFACTURER'S NAME SECTION 1 grace &-_Conoanv_______________ I________ AOORESS {.Sumher, Street. City, State, ant ZIP C&zej * EMSRCENCV TE.E*-ONE no. fil 7-R7A-1 inn CHEMICAL NAME ANO SYNONYMS Expanded Lihhv. Montana V#rmTculit# Chemical family Magnesium Aluaisosilieate Mineral TRAOC NAkiE ANO SVkONVMI Industrial Vermieulite-Size *1. *2. f6rmula (Kq,Ca,K)-(Xl,Fe,Mq)-(Si.JUl' (0) (OH) H ** A * 4. 4. SECTION II - HAZARDOUS INGREDIENTS "Contains less than 0.1% by weight o a naturally occurring contaminant treaolite. OSKA Regulation 1910.1001 defines tramolite as asbestos. Some forms of txamolite are platy. Other forms can be fibrillated by physical handling to release airborne "asbestos fibers". Regulation 1910.1001 places a limit of 2 "asbestos fibers"/cc; 8 hour time weighted average and a maxi mum of 10 "asbestos fibers"/cc at any one time for airborne fiber exposure. The physical handling given to expanded Versniculite can release both air borne fibers and nuisance dust. Refer to OSHA Regulation 1910.1001 for ap proved control procedures. SECTION III - PHYSICAL DATA BOILING POINT (*F.) VAROR PRESSURE (mm Hg.) VAROR DENSITY (AlR2) solubility IN WATER NA NA HA slight, SPECIFIC GRAVITY (I^O'l) PERCENT. VOLATILE tv VOLUME (*> EVAPORATION RATE ( !) Bulk Density lbs/c.f. A.T**,>ANeEANO* Tree flowing dark brown to tan colored particles. NS HA HA ___ _____ __ ____ ________, FLASH POINT SECTION IV FIRE AND EXPLOSION HAZARD DATA hot APPLICABLE USM) FLAMMABLE LIMITS EXTINGUISHING MEDIA SFECIAL FIFE FIGHTING FROCEOURES UNUSUAL FIRE ANO EXPLOSION HAZARDS |( PAGE (1) (Continupd on nvirn side) Form OSHA-20 Rn. Mr 7: The information contained herein is based on knowledge believed to be reliable but W.R. GRACE CO. MAKES HO VIARP.AH7IES, EXPRESS OR IMPLIED, AS TO THE ACCURACY OR ADEQUACY THEREOF. Nothing herein excuses the recipient hereof from such duties as shall be imposed by the Occupational Safety and Health Act of 1970 and regula tions issued pursuant thereto. DUP 1121656 tsa-i ^ SEC7IC.'': . HEALTH HAZARD DATA "--s.:-: ` w-.v'i Dust rusirs^p fraction 5 iser..':*, . Total dust 15 m-- 'y. Airborne asbestos fiber 2f/ec 7.W.A.-Ceiling lOf/cc at or.e time. EVtSCCNCV AND PIAST AiO PROCEOUBES NA SECTION VI - REACTIVITY DATA STaiu`TV UNSTABLE J STABLE CONDITIONS TO AVOtO incomatasiuTv (.Uattnsls to avoid; NOT APPLICABLE HAZARDOUS DECOMPOSITION SAOOUCTS HAZARDOUS POLYMI AlZATION MAY OCCUR WILL. NOT OCCUR CONDITIONS TO AVOtO SECTION VII - SPILL OR LEAK PROCEDURES S7E?S TO SE TAKEN IN CASE MATCMIAl. IS .SLEAS0 OM SailLSO Dampen slightly or me ether techniques which control airborne fibers and dust within the limits of Section V above. waste disposal, method -----------------------------------------------Use ..disoasaY which control airborne fibers ar.d dust within the TLV limits of Section V above. See OSHA Standard 1910.1001. _______ Paragraph (h) ( 2 ) Waste Disposal. SECTION VIII -^SPECIAL PROTECTION INFORMATION See OSHA 1910.1001-Controls such as isolation, enclosure, exhaust ventilation and dust collection shall be used if necessary to meet exposure limits. Also see OSHA Standard 1910.1001 Personal Protective Equipment for dealing with work environments in excess of exposure limits. SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING AMD STORING OTHER PRECAUTIONS PAG: 12) 6> s ts 50 Forrn OSHA`20 *. Mjy 7J DUP 1121657 fM(M K*r CC: H. D. Boyce E. I. ou Pont dcNcmouw S Compact J. C. Lang (Info.only) R. K. Mason Wilmington, Delaware W. C. Weaver H. C. Harden C. J. Adolph _ R J. Ham KMOlMCSmMA eCHRTMCNT cc: Bowen Rtce Route: Wesley fi Britto: k' Day Spj SJS68* c- Jones, Purchasing -///September 12, 1966 FIELD PROJECT MANAGERS: F. C. BAILIS W. S. BRIGGS w! s! FREE H. S. STANTON, JR. W. C. KANNEAR R. H. DAVIS R. G. STERNBERGER J. K. ADDISON ASHTABULA BEAUMONT CAPE FEAR CHATTANOOGA CIRCLEVILLE FLORENCE KINSTON LOUISVILLE MARTINSVILLE W. A. SAMANS A. S. TRUMPORE,JR. H. F. REDMILE W. S. LEWIN A. W. ROGERS, ASST. R. L. SPITZ S. KREWATCH W. G. HARRIS MAY PLANT MEMPHIS WORKS OLD HICKORY PARLIN SPRUANCE WASHINGTON WKS. WAYNESBORO YERKES ARMSTRONG CONTRACTING k SUPPLY CORP. Reference - Letter of May 2, 1968 to Armstrong Contracting k Supply Corp. Letter of July 19, 1968 to FPM's on those sites where Armstrong Contracting k Supply Corp. is working. It is noted that in accordance with established procedures, inspections are being made by Armstrong's insurance carrier, Aetna Life k Casualty Company, and in at least one instance a copy of their inspection report has been furnished to Du Pont. Without commenting on the ade quacy of the report, we believe it is important to keep the following points in mind: 1. We should take ncr action on the basis of a copy of the Aetna report to Armstrong. If the report is forwarded by Armstrong with their recommendation for action, then we should proceed so long as the recommendations "fall within the general intent of the contract." 2. If the recommendations involve radical changes in facilities or are in any way controversial, they should be referred to this office. We will review the proposals with H. C. Marden and Division Manage ment and attempt to assure uniformity in dealing with the subject at all sites. If inspection has not been made of your facilities you should contact the Armstrong Branc,. or District Office servicing your Job and remind them of their obligation. Similarly, follow-up inspections at six ecrrcN tmimos re* et .Tt,, uvino ... turnout* cmcmirrmr DUP 1120482 X -2- September 12, 1968 month intervals should be expected. Even though you do not receive any communication from Armstrong relative to the inspection, your site records should be adequately documented as to date, participants and extent of inspection and any pertinent comments by Aetna. CJLJr./jrr DUP 1120483 -\ N cc: W.S.Briggs-FPM-Beaumont Constr. !2 A.D.Day-FPM-Cape Fear Constr.(2) W.S.Free-FPM-Chattanooga Constr.( H.F.Redmile-FPM-Old Hickory Const G.E.Barlow,Jr.-FPM-Wilm.Area Cons D.E.Sours-Spruanee Constr.(2) E.C.Jones-Purchasing-Louviers R.J.Ham-Construction-Louviers J.R.Allen-ESD M.L.Jones C.L.Westendorf J.M.Allerdice C.G.Dahlstrom C.O.Utley W.L.Johns F.L.Hunt W.H.Zane A.0.McAlister April 30, 1968 TO: K. E. KEUPER - SAFETT SUPERINTENDENT CONSTRUCTION DIVISION FROM: F. L. HUNT - W. H SAFETY - DUST CONTROL In reference to' my letter of April 24, 1968, the information received that Armaspray contained crocidolite asbestos fiber has been reputed. Mr. W. B. King of Armstrong Cork Company, manu facturers of Armaspray, said that it contains 9.CX Amosite asbestos fiber and no other asbestos fiber is used. DU? 0913312 ptl E. I. ou Pont oe Nemours 5 Company WILMINGTON. DELAWARE tttM 0 CC: K. E. Keuper R. J. Ham (For information; E. C. Jones - Purch. eCPftWTMCKT FIELD PROJECT MANAGERS: " W. s. BRIGGS BEAUMONT A. D. DAY CAPE FEA*1 --" W. S. FREE CHATTANOOGA H. S. STANTON, JR. CIRCLEVILLE W. C. MANNEAR FLORENCE R. H. DAVIS KINSTON R. G. STERNBERGER LOUISVILLE J. K. ADDISON MARTINSVILLE W. A. SAMANS MAY PLANT A. S. TRUMPORE, JR. MEMPHIS H. F. REDMILE OLD HICKORY W. S. LEV/IN PARLIN A. W. ROGERS, AFPM SPP.UANCE R. L. SPITZ WASH. WORKS S. KREWATCH WAYNESBORO W. G. HARRIS YERKES July 19, 1968,^ !O /4 * ; Wis . * \ ***' V-W, LLi J j i_ \ t wC .* ' -- --, < s''' / <--^ ARMSTRONG CONTRACTING AND SUPPLT CORP. We are attaching a copy of the material which Armstrong Contracting and Supply Corporation has issued to its District and Branch Managers. This is in conformance with the provisions of Article 7 of Appendix A of the current Master Contract with Du Pont. You will note that the inspections are scheduled to be made now and to continue on approximately a six-month interval. If you find that this schedule is not being followed, we suggest you contact the Arm strong office which services your job and inquire as to when the inspection will be made. Any comments or suggestions should be followed so long as they fall within the general Intent of the con tract provisions. Any controversial questions should be referred promptly to this office. CONSTRUCTION DIVISION C.pJ. Lawrence, Jr. Contract Superintends CJLJr./pb Attach. errrce tmimss roe ecrrce kiwiae ... rmmovm c*c*ibtbt DUP 1200005 All District. &. 3rsnch Managers - Du Pont Sites A. H. Svabs, Wilmington Du Pont Fabrication Shops - Safety Inspection To comply with our obligations as set forth in Article 7 of Appendix A of the present Du Pont Contract, the following arrangements were worked out in Lancaster between our compar.y and our insurance carrier. The required safety inspection of the temporary construction facilities will be conducted by the Safety Engineer of the ~ \ OAetna Casualty & Surety Company's local office serving your " . jA^Du Pont site. The Safety Engineer shall be accompanied by you as the branch manager and a representative off Do Pont . appointed bv...the construction prolect manager or tne site, -l4 involved. Aetna will instruct their local Safety Engineer tb '"dofflUct the inspection within the next two to three weeks and each six months thereafter. You will be contacted within the next days by an Aetna representative to arrange for a safety inspection as required under the terms of our contract with Du Pont. Aatna's Safety Engineer will be instructed to comply with the recommended Health Safaty Practices for Handling ana Applying Insulation Products Containing Asbestos ss published by the National Insulation Manufacturers Association, as it pertains to dust and ita control in tha shop. In addition, proper use of safety equipment! such as goggles, respirators, etc., good housekeeping practices, machine guards, ventilation, exhaust systems, will also form a part of this inspection. Following the inspection, the Safety Engineer will issue a report with copies to you and to tha General Office in Lancaster with recommendations. It wae felt by Lancaster as well as by this offics that k stsp by* step inspection procedure should not be established since this could prove unworkable. We have ordered a sufficient supply of the above-mentioned National Insulation Manufacturers Association's publication for your use and reference. Tha booklet will be forwarded to you Immediately from this office upon receipt. CC: J. E. Zeller end F. L. Gardner, Lancaster SLR DUP 0913288 ktP*At w stc^hCnSON, WAD SICPHCNJON marlin Thomason -.W U. STEPHENSON axd THOMPSON STEPHENSON BUILDING / 712 DIVISION STREET ORANGE,TEXAS 77B30 / S23-9396 1 Dtetsbtr 16, 1970 AIRMAIL Dr. John A. Zapp, Jr. E.Z. DuPont deNemours Company Haskell Laboratories Wilmington, Delaware 19898 Dear Dr. Zapp: Your name was given to us over the telephone this morning by Dr. Shield with the American Conference of Industrial Hygienists in Cincinnati. Dr. Shield stated that you were a member of a committee referred to as Z-34 Industrial Hygiene Committee and that you may be able to assist us. We desire to obtain as soon as possible any information or literature concerning the standard or threshold limit values on the inhalation of asbestos dust set by your committee at any time from the years 1940 (or prior thereto) up to about the year 1950. We understand that in about the year 1950, the responsibility for the setting of these threshold limits was shifted to the ACIH. We will be pleased to pay you for any research or to pay anyone you might request to do this for us, as wall as for copies of any publications or threshold limit values*' recommended by this Committee during the years mentioned. If you will be so kind, we will appreciate it if you will let us hear from you as soon as possible. Yours truly. WS : jb Ward Stephenson J i rt: t/ HASKELL l iT' DUP 1120986 |> *M * ! inwi C. I. eu Pont ecNCMOum S Comuhy wilminotom. oclawamc 9ltlTU(nf Britton - Riee e-rs---- * nxeun (Routt} rngfiia lixir iftnosey Vfs_ "vS 3*.: Field Project ana;era (All Armstrong Sitea) H. D. Scyee ? C. Lang (For infonaation) ijjvtr - ... Dortch K. Ktuptr C. J. Adolph H. J. Ham R. C. Rtbtr E. C. Jontt Pureh. Cast. May 2, 1968 Arsatrong Contracting tad Supply Corp. 2608 Kirkwood Highway/ Wilaington, Delawarp/19805 TXERXA1 UISUUTIJJI - BUUIT CONTRACT GantlaMS: Appendix "A" dated January 1. 1968, to the Blanket Contract or the ease date between Armstrong Contracting and Supply Corpora tion and Du Pont, provide* in part ae follow*: Article 7. Du Pont will furaiah all temporary eonatruetion feeilitlae, including hop, officaa, eeol room* and aioilar facilities required by the Contractor at the Plant site. Contreetor will consult with Du Pont and provide its sdviee on eliaineting hatarda to health and safety which are peculiarly prevalent In the in sulation industry and are encountered in handling, fabricating and applying insulation materials, only so far sa such hatarda pertain to con struction of and operations in temporary i construction shop*. Contractor shall, fro* * tins to tlae, hut not leas frequently then every six souths, review the condition of shop facilities end sake recommendation* to Du Pont for the saintenaace therein of currant practices in ths insulation industry pertalnlnc to the elimination of such hatarda. --- -J 2065TDUP 0900984 1 E. I. ou Pont m Ncmouhs & Company Wilminoton. OCUAWAMC 1NM ) In order to be assured that optisus ccnditioas art being a*iatainad with respect to the quality of air la the various teaporary construction shops, tha attaehad proeadura covering "Safety and Oust Control" will ba plaead in effect June 1, 1563. Tha ultimate suecass of this progras will ba cost dapanaaat sa tha wholahaartad eooparation of your easloyeea fro* tha appro priate aaaagar down to tha eraftaaaa selected fot air onttoring. It is vary nacasssry that tha son ba convinead that tha purpose of ch saspling is to aasura that thay art being provided vita a safe place in which to word and that it ia in tneir bast in* taraat to ba cooperative. Va recognise that this progra* Bust ba conveyed to tna son through your aunervirion and, to that and,, w* ash your cooperation ia tha following steps: 1. Advise your various Cistriet Offices, under which Su Pont work is being perfomed, of the inaugera* . tioa of this progra*. Extra copies of tha procedure are atttached should you care to furnish the* to your Managers. 2. Instruct your Managers that they will be requested to visit each Ou Pont site under their supervision for a full discussion of tha progra* with Armstrong's job supervision as* Su Pont representatives. 3. Arrange for whatever discussion ia necessary with tr.a eraft scan on the job and say. appropriate edviee to union representatives. 1. Assist ia selection of tha eaployea at each sits to be used to aooitor the air in the fabrication shop and la proper orientation of tne nan salactad. 5. Keep abreast of tbe operation of the progra* for the first few aonths to be assured that it la functioning arsothly and that tnere are no alsunderstsndlnga es to ita purpose. err*ce f*ll 0 lt"t kv>e DUF 0900985 120652 E. I. eu Po*rr oc Ncmouns & Company WlUMINOTON. OCbAWAKC 1HM CM41MCSMIN* DC^AMTMCMt 3 la y1 of tbo naturo of tbla probloa, wo fool that tbo propoaod proeoauro will oporatt to tbo odYiattfo of all eeaeoratd aad truat that wo may baro your uaual eooporatloa la tbla aattor. Tory truly your*, CJLJr Attae TT*A YoiaOO # OCYYta k>'MO . . WOWO tfP 0900986 128633