CTD031552
CertainTeed Storm Sewer Pipe speeds installation, fights corrosion.
A/C Storm Sewer Piping Products
Made to be Tough.
CertainTeed A/C Storm Sewer Pipe is manufactured from a mixture of Portland cement, asbestos and silica. The pipe made from this mixture is dense and tough, non-organic, and immune to electrolytic and galvanic effects. It is highly resistant to chemical attack and corrosion of all types. In the manufacturing process, the pipe is formed under heavy pressure for high density and strength, and is autoclave-cured for chemical stability.
CertainTeed Storm Sewer Pipe meets all requirements of ASTM C663, AASHTO Designation M-217, and Section 64 of the California Division of Highways standards.
CTD031553
CertainTeed
For Storm Drainage Systems Anywhere.
Install CertainTeed Storm Sewer Pipe wherever reliable storm drainage is required. Applications include high ways, roads, urban streets, institu tional grounds, airports, parking lots and other paved areas
Flexible Couplings for Quicker, Better Installation.
CertainTeed A/C Storm Sewer Pipe is joined with flexible plastic couplings. As a result, there's no need to grout the joints Assembly time is reduced and backfilling can proceed immediately. Joints can deflect for curved-line installations. And because the cou plings are designed to seal in water and keep out sand and silt, there's less chance of bedding material being washed out This helps protect the pipe's structural integrity
Extra Capacity with Smaller Pipe.
With its smooth interior surface, CertainTeed Storm Sewer Pipe has a Manning flow coefficient of n=0 010. providing extra capacity with smaller pipe diameters, and reducing the chance of blockage. It can be installed on flatter grades with assurance of efficient drainage. Its relatively light weight in long lengths permits easier handling and reduced installation costs
Full Range of Sizes, Full Line of Fittings.
CertainTeed A/C Storm Sewer Pipe is made in diameters from 6" through 24", in standard 13' lengths, and in strength classifications lbs./ft. of dia /tin. ft. of 2000D, 2500D, 3000D and 3750D Fittings include wyes, tees and 45 and 90 elbows
CTD031554
A/C Storm Sewer Piping Products
Pipe Weights (Lbs./Ft.)
Size
2000 D
2500 D
3000D
6 - -8 - - 12.2 10 17.7 18.6 18.6
12 21.1 25.2 26.1
14
29.9
33.9
35.3
15
33.9
38.6
41.5
16
39.3
43.8
46.5
18
46.8
53.2
59.1
20
58.9
65.3
71.5
21 66.2 71.1 78.6
24
87.7
94.7
101.0
L
Pipe Dimensions
Pipe Size
All Classes CP
6-8
2.40
1.00
10
2.90
1.00
12-14-15-16 18-20-21 24
3.13 4.00 4.88
1.50 1.88 2.25
O.D.
3750D
9.3 12.2 22.0
29.2 40.4 45.5
52.7 66.2 80.0
87.5 116.0
Pipe
Size 6 8
O.D.
-
-
2000D B.O.D.
-
-
10
11.00
11.14
12
13.06
13.24
14
15.14
15.50
15
16.26
16.56
16
17.30
17.60
18
19.34
19.80
20
21 42
22.06
21
22.46
23.18
24
25.88
26.48
All dimensions are in inches
O.D. -
2500D
B.O.D. -
11.00
11.26
13.06 15.14 16.26
13.52 15.70 16.82
ro Si
o
17.30 19.62 21.72
17.94 22.32
22.76 26.32
23.44 26.80
3000D
O.D.
B.O.D.
-
8.90
-
9.06
11.00
11.30
13.34 15.46 16.68
13.52 15.70 16.92
17.74 20.06 22.18
17.98 20.20 22.32
23.22 26.32
23.62 26.86
O.D. 6.85 8.90
3750D
B.O.D. 7.04 9.06
11.20
11 45
13.48 15.84 16.90
13.70 15.97 17.02
17.98 20.06 22.18
23.22 26.32
18.10 20.34 22.66
23.80 27.40
CTD031555
CertainTeed
Pipe Size
6 8 10
12 14 15
16 18 20
21 24
T
Coupling Dimensions
All Classes TL
2000D C.O.D.
2500D C.O.D.
.12 5.00 -
-
.12 5.00 -
-
.12
6.00
11.05
11.05
.15
6.75
13.15
13.15
.15
6.75
15.21
15.21
.15
6.75
16.30
16.30
.15
6.75
17.34
17.34
.18
8.50
19.42
19.69
.18
8.50
21.47
21.77
.18
8.50
22.51
22.81
.21
10.25
25.96
26.39
3000D C.O.D.
-
8.97 11.05
13.42 15.52 16.73
17.77 20.13 22.24
23.27 26.39
3750D C.O D.
6.93 8.97 11.24
13.56 15.89 16.95
18.02 20.13 22.24
23.27 26.39
90 Reducing Tee
Size 8x 6
lOx 8 12x10
L 39.0 39.0 39.0
La 11.0 12.5 13.5
F 10.25 11.50 12.75
14x12 15x14
39.0 39.0
14.5 16.5
14.00 16.50
16x15 18x16 20x18
39.0 52.0 52.0
16.5 15.00 18.5 16.50 19.5 18.25
21x20 24x21
52.0 52.0
19.5 20.50 19.5 20.25
All dimensions are in inches Other size reduction combination available
45 Reducing Wyes
Size 8x 6 lOx 8 12x10
14x12 15x14
16x15 18x16 20x18
21x20 24x21
L 39.0 39.0 39.0
39.0 39.0
39.0 52.0 52.0
52.0 52.0
La 16.5 20.0 22.5
25.5 29.6
28.5 32.0 35.0
38.2 39.0
F 16.25 19.50 22.75
25.75 29.75
29.50 31.25 35.25
37.80 39.00
CTD031556
A/C Storm Sewer Piping Products
Pipe Size
6 8 10
12 14 15
16 18 20
21 24
l_2
9.75 9.75 9.75
9.75 9.75 9.75
9.75 19.50 19 50
19.50 19.50
Lc
9.50 9.50 9.50
9.50 9.25 9.25
9.25 18.50 18.25
18.25 18.00
All dimensions are in inches
Ls
16.47 16.47 16.47
16.47 16.47 16.29
16.29 32.58 32.40
32.40 32.23
Pipe Size
8x 8 10x10 12x12
14x14 15x15 16x16
18x18 20x20 21x21
24x24
L
39.0 39.0 39.0
39.0 39.0 39.0
52.0 52.0 52.0
78.0
La
11.0 12.5 13.5
14.5 16.5 16.5
18.5 19.5 20.5
21.5
F 10.25 11.75 12.75
14.25 16.50 15.25
17.25 18.25 20.50 20.25
CTD031557
CertainTeed
SHORT FORM SPECIFICATION A/C STORM DRAIN PIPE
1. General
1 1 Scope This specification covers CertainTeed A/C Storm Drain Pipe intended for use in storm water drainage of highways, airports, farms, foundations and other drain age systems.
1.2 Conformance CertainTeed A/C Storm Drain Pipe, as manufactured to meet these specifications, meets the requirements of the latest issues of the fol lowing specifications: ASTM C 663 ASTM C 500
AASHTO Designation M-217, Division of High ways, State of California, Section 64
2. General Requirements
2 1 Sizes & Classes
Pipe shall be manufactured
in the following sizes and
classes:
D-Load Nominal Sizes
Class
Inside Dia. (in.)
2000D
10, 12, 14, 15, 16 18, 20, 21, 24
2500D
10, 12, 14. 15, 16 18, 20, 21, 24
3000 D 3750D
8, 10, 12, 14, 15 16, 18, 20, 21, 24
6, 8, 10, 12, 14, 15, 16, 18, 21, 24
2.2 Lengths
3. Testing
2.2.1 Standard Lengths The standard nominal length of storm drain pipe shall be 13 feet in all sizes and classes. At least 85% of the total number of pipes in any one class and size ex cluding short lengths shall be standard lengths. The remaining 15% or less may be in random lengths of not less than 7 feet.
2.2.2 Short Lengths Short lengths shall not exceed 6'6". Short lengths may be ordered as 1/4 lengths (3'3") or half lengths <6'6") in machined ends only MEO)
2.3 Couplings A durable plastic coupling shall be provided with each length of pipe for the pur pose of maintaining align ment and to ensure close joints.
2 4 Fittings
3.1 Chemical Requirements When tested in accordance with ASTM C 500, the amount of uncombined calcium hydroxide shall not exceed 1.0 percent.
3.2 Crushing Strength Crushing tests in accordance with Division of Highways, State of California Specifi cations or ASTM C 500 shall be performed on a pipe sam ple taken from each lot of each size and class of pipe : This sample shall not fail until the total applied load exceeds the D load class crushing strength of pipe. If any sample fails to meet the crushing strengths require ment, one sample from each of two additional pipe lengths of the same lot shall be sub jected to the crush test. Fail ure of one of these additional samples to meet the crush ing strength requirement shall be cause for rejection of the entire lot of pipe.
Storm drain fittings shall be
made of the same material as
the pipe or of material having
equivalent crushing strength
and design for the pipe with
which they will be used.
The equivalent concrete pipe
classes based on the ultimate
strength of the concrete pipe are
as follows: A/C
Concrete
D-Load 2000D 2500 D 3000 D 3750D
Pipe Class III
None IV V
CTD031558
CertainTeed Ef
District Offices
Atlanta Pipe District
2295 Parklake Dr., N.E. Suite 510 Atlanta, GA 30345 404/938-4616 TWX: 810-766-4926
Columbus Pipe District
1855 Fountain Square Court Suite 106 Columbus, OH 43224 614/267-9435 TWX: 810-482-1732
Denver Pipe District
5115 South Valley Highway Suite 156 Englewood, CO 80111 303/773-2760 TWX: 910-935-0888
Houston Pipe District
Suite 670 P.O. Box 25185 Houston, TX 77005 713/960-1470 TWX 910-881-1652
Los Angeles Pipe District
1801 East Parkcourt Piace Suite 103 Santa Ana, CA 92705 714/972-2644 From Los Angeles: 213/625-1915 TWX: 910-591-1661
Phoenix Branch Office
Suite B-3 532 East Maryland Phoenix, AZ 85012 602/274-3641 TWX: 910-951-1462
Code No. 403502
New Orleans Pipe District
P.O. Box 66318 Audubon Station Baton Rouge, LA 70896 504/383-8094 TWX: 510-993-3454
Philadelphia Pipe District
987 Old Eagle School Road Suite 703 Wayne, PA 19087 215/687-9250 TWX: 510-668-0641
St. Louis Pipe District
301 Sovereign Court Suite 111, Regency Park Manchester, MO 63011 314/394-7330 TWX: 910-760-1850
San Francisco Pipe District
3000 Citrus Circle Suite 210 Walnut Creek, CA 94598 415/938-6800 TWX: 910-385-6815
Export
P.O. Box 860 Valley Forge, PA 19482 215/687-5000 TWX: 510-668-1912 TELEX: 845-263
Pipe & Plastics Group
CertainTeed Corporation P.O. Box 860 Valley Forge, Pa 19482
Printed in U.S.A. 0810
CTD031559