Document ZBBRaNRMqyOaNnZqz5gGL90wJ

Smith Marine Service, Inc. 3502 BRDADWAY-P. . BOX 12106 HOUSTON, TEXAS 77017 713/ 649-SOB3 October 14, 1974 Mr. J oe Same Exxon Company, U.S.A. P. 0. Box" 1512 Houston, Texas 77001 SUBJECT: Service Report VESSEL: S.SXRxxon Bostonf'`-Newport News, Va. ; 10-3-74 thru 10-6-74 1. Replaced selector switch, #2 burner, fire room console, starboard boiler. 2. Repaired selector switch, #1 burner, engine room console, port boiler. 3. Repaired alarm switch on de-superheater alarm, engineers panel. Assisted Copes-Vaulcan engineer on de-superheater controller. Replaced tube in controller (alarm unit). 4. Replaced #3 burner selector switch, starboard boiler, engine room console. 5. Replaced #1 burner ready relay, starboard boiler. - 6. Replaced #2 burner ready relay, starboard boiler. 7. Adjusted, main fuel oil valve limit switch, port boiler. 8. Adjusted #3 and #4 burner oil valve limit switches, port boiler. 9. Replaced LTB.-7 relay, port boiler 10. Checked fire and ballast pump, Foxboro controller. 11. Operated boilers for setting and testing of safety valve, port boiler. Report by: Frank Smith cc: Accounting Mr. E. Thompson EXX-MOR-010855