Document ZB5oOENzkRM6m8rdxdBXn799Y
Attached is a summary of the results of the fiber sampling done by me on 25, 26, and 27 April 1972 at Dallas, Oklahoma City, and San Antonio respectively. If you have specific questions concerning this data or wish to review the slides, please contact Frank Serafin at 113 or me.
Present TLV for fibers of our variety is 5 fibers longer than
5 microns
per ml.
/
H.A. Eschenbach HAE:mh Enclosures
DALLAS
, /017039
Sample #
1 DAL
2 DAL
Operation Monokote Bagging Monokote Mixer
Fibers Per ml (Greater than
5 microns in length)
5.1
1.1
3 DAL 4 DAL 5 DAL 6 DAL 7 DAL 8 DAL
Monokote Truck Loader
3.5
Vermiculite Furnace Operator
0.0
Perlite Bagging
1.5
Redi-Earth Blending
1.1
Terra Lite Bagging (#2 Furnace) 2.6
Blank
0.0
Remarks
All hair-like chrysotile.
Worker did no mixing duri: sample. This is more of general area sample. Chr>
Chrysotile.
Other dust but no fibers.
Needle type.
Chrysotile and needle type Needle type.
COMMENTS:
All samples were near or below present emergency TLV of 5 fibers. Apparently, 1.1 is a good general room value for the Monokote - Redi-Earth area.
In the furnace area, it appears that general area ventilation (large roof fan) keeps fibers at a low level even though there is moderate visible dust. This type of ventilation is practical only in warmer localities and may be restricted by air pollution control agencies in the future.
There are no recommendations at this time.
Sample #
1 SA
2 SA
Operation
Concrete Aggregate Bagging
Furnace Area
3 SA 4 SA
Warehouse Blank
SAN ANTONIO
Fibers Per Ml (Greater than 5 microns in length)
5.3
10.7
0.2 0.0
(017020,
Remarks Needle type.
Stationary sample in mid furnace area. Needle. Needle.
-------- ----------
COMMENTS:
If the large lower wall fan Is in operation, fiber counts may be significantly lower. However, use of an approved respirator by the payloader driver during ore handling and anyone spending more than a very short and infrequent period of time in the furnace area is recommended.
OKLAHOMA CITY
017021
Sample #
1 OK
2 OK
Operation
Vermiculite Bagging (Ind. Insul.- Libby Itl)
Furnace Room
3 OK 4 OK
Blank Warehouse
Fibers Per Ml (Greater than 5 microns in
length) 2.8
16.3
0.0 0.0
Remarks
Needle type. Housekeepin excellent.
General room sample. Sto: throwing dust.
COMMENTS:
High concentrations in the furnace room were probably due to the need for a stoner adjustment. Since there is no general room ventilation in this area, fibers tend to accumulate and circulate. The use of a respirator in the furnace room should be mandatory until adequate engineering controls are installed.