Document ZB53nKwj01nr1zoJRD2n71B7Z
Heating Systems Boilers, Cast-Iron
UnitedStates Radiator (corporation
General Oliices; Detroit, Michigan
Branches and Sales Oilices in Principal Cities
Detroit, Michigan
CAPITOL SUNRAY No. 9 SERIES BOILERS
For Automatic Firing
(Oil, Stoker or Gas)
CAPITOL THINTUBE RADIATORS
3-Tube
Heights
Per Section Heating Surface
25' 1.6SqFt
4-Tube
19* 1.6SqFt 22' 1.8 Sq Ft 25' 2.0SqFt
5-Tube 22' 2.1 SqFt 25' 2.4 Sq Ft
Boiler No.
9-4 9-5 9-6 . 9-7 9-8 9-9
Capacity Square Feet
Steam
1360 1785 2210 2630 3055 3480
Water
2175 2855 3535 4205 4885 5565
1-B-R Sq Ft Direct Cast
Iron Radiation
Steam
925 1245 1565 1885 2205 2525
Water
2500 3530 4040
6-Tube
19' 2.3 Sq Ft 25' 3.0 Sq Ft 32' 3.7 Sq Ft
*1% in. Centers.
40 per cent less space needed for these graceful, efficient Capitol ThinTube Kadjators.
U. S. THINTUBE WALL RADIATOR
"DEEPFIRE" HOT WATER SUPPLY BOILERS
Coal Fired
Tested to 50 lb Hydrostatic'
Pressure for 100 lb Working
Pressure.
Boiler No.
30-D 40-D
50-D 60-D
30 40 50 60
Capacity--flallnn^
100 Rise 6 Hours
792 15)2 2160 2700
85 Rise 1 Hour
155 297 423 529
100 Rise 1 Hour
132 252 360 450
This Thintube Radiator has been designed
for wall hung application. The narrow
width of 3% in. and over-all height of
24 in. readily permits substitution for the heavier type conventional wail radiator,
the production of which has been re stricted by the War Production Board.
LITERATURE UPON REQUEST
1092
Heating Systems Boilers, Cast-Iron
United States Radiator (orporation
General Oliices: Detroit, Michigan
Branches and Sales Oilices in Principal Cities
Detroit, Michigan
"A" Series--All Fuels
"50" Series--All Fuels
Boiler No.
A-7 A-8 A-9 A-10 A-II
Capacity Square Feet
Steam
770 980 1190 1395 1605
Water
1235 1565 1900 2235 2565
I-B-R Sq Ft; Direct Cast Iron Radiation *
Steam
340 440 540 640 , 740
Water
545 705 865 1025 1185
B-8 B-9 B-10 B-ll B-12 B-13 B-14
"B" Series--All Fuels
1875 2210 2520 2790 3035 3280
3525
3000 3535 4035 4460 4855 5245 5640
920
mo
1275 1440 1580 1730 1880
- 1470 1770
.2040 2300 2530 2770 3000
"C" Series--All Fuels
Boiler No.
950 1050 1150 1250 1350 1450 1550 1650 1750 1650
Capacity Square Feet
Steam
8800 10.235 11.600 12.950 14.260 15,600 16.910 18,190 19.435 20.655
Water
14.080 16,380 18.555 20.715 22.815 24.960 27.060 29.100 31.100 33.050
Direct Cast
Iron Radiator Loads Sq Ft
Steam
5640 6560 7435 8300 9140 10.000 10.840 11.660 12.460 13,240
Water
9025 10.500 11.895 13.280 14.625 16.000 17345 18,655 19,935 21,185
"WN" Series--All Fuels
WN-277 WN-278 WN-279 WN-280 WN-281 WN-282 WN-283 WN-284
6060 7435 8800 10,235 11.600 12.950 14.260 15.600
9695 11.895 14.080 16.380 . 18,555 20.715
22,815 24.960
3885 4765 5640 6560 7435 8300 9140 10.000
6215 7625 9025 10.500
11,895 13.280 14.625 16,000
Boiler No.
C-12 C-14 C-16 C-18 C-20 C-22 C-24 C-26 C-28 C-30
Capacity Square Feet -
Steam
4700
5600 6500 7300
8000 8700 9300 9900 10300
11.000
'
Water
7760 9240 10,730 12.050 13.200 14360 15350 16335 17325 18325
Direct Cast Iron Radiator
Loads Sq Ft
Steam
2250 2715 3160 3645 4110 4575 5040 5450 5800 6110
Water
3600 4345 5090 5830 6575 7320 8065 8720 9280 9775
"WNO" Series--For Oil Firing
WN-0277 WN-0278 WN-0279 WN-0280 WN-0281 WN-0282 WN-0283 WN-0284 WN-0285 WN-0286 WN-0287 WN-0288 WN-0289
6640 7640 8640 9645 10,640 11,800 12.920 14,060 15.200 16320 17,435 18360 19,675
10,620 12.225
13.825 15,425
17,020 18.885
20,670 22,500 24315 26.115
27,900 29.695 31,485
4935 5680 6425 7170 7910
8775 9605 10,455 11,300
12.135 12,965 13.800 14.630
7895 9090 10.280 11.470 12.655 14.040 15370 16.730 18,080 19.415 20.745 * 22.080 23.410-