Product . Ta*t Monsanto Ghemical Gompany Anniacon, Alabama Plant Laboratory STANDARD ANALYTICAL METHOD AROCLORS AND PYRANOLS POUR POINT Mathad Na. , ^53 DATI IISUBD 5/29/61 WRITTEN BY W.W.K. I PAOI | i op 3 | APPROVED BY I W.W.K. Thl* Mathed 1~~1 Suparsada* f1 Ravlaos SCOPE Instruction* l..u.d On _____ 6/l/l/57 This proosdura deseribas the method for determining the pour point of Aroclors and Pyranols following a modified ASM D-97 procedure EQUIPMENT 1* Single or four pl&oe Cloud and Pour Test apparatus, ASTH D-97* 2. Test cylinders, pyrtoc, for above. . 3. Thermometer - ASM No* E-l(5o) Cloud and Pour Test, Range -38*c to +50*c and ASM No. E-l(6c) Cloud and Pour Test, Low, Range -SO*o to +20*e. Reagents 1* Methanol or Acetone. 2. Dry ice. SAFETY Aroclors and fyranols are irritating to the skin. The Vapors of hot materials are irritating to the eyes and upper respiratory system. If accidental contact 1b made with the eyes, flush inmediately with large quantities of water for at least 15 minutes and get immediate medical attention. The higher Aroclors must be hot to pour, so be careful of thermal burns. DSW 331753 STLCOPCB4078328 Standard Analytical Method 053 May 29, 1961 Pag 2 of 3 p.. DETERMINATION 1* Select the proper thermometer and oooling bath medium from below 1 Material Aroolor 1262 Aroolor 1260 Aroolor 1254 Aroolor 1242 Thermometer -38 to +50*o -38 to +50*o -38 to +50*o -38 to +50*o Bath Water Ice-Water Ice-Salt Dry Ioe-Alo* Approximate Pour Point +38*o 430*0 410* 0 -18*o Aroolor 1232 Inortsen PPG fyranol 1470 -80 to +20*o -SO to +20*o -80 to +20*o Dry Ioe-Alo. Dry Ioe-Alo* Dry Ice-Acetone lower than -30*o lower than -32*o lower than -44*0 2* Shake the sample well to mix* On the higher Aroolors it will be necessary to heat the aanple to make it fluid enough to mix* 3* Add 2 - 2 l/4 inches of sample to the test cylinder* These depths must be olosely adhered to. . 4* Insert the proper thermometer thru a oork or rubber stopper* The thermometer must be in the center of the stopper* . 5* Plaoe the thermometer in the test cylinder so that the beginning of the capillary is l/8 inch below the surface of the aaqple. Be sure the therm ometer is in a vertioal position* 6* If the sample had to be heated to pour allow it to oool to &n* 12*0 above expected pour point before placing in bath* For samples pouring well below room temperature place in bath directly# 7* Adjust the bath to 10* - 15*o below expected pour point* 6* KLaoe teat cylinder and sample in bath holder* 9* When the temperature of the sample is about 10*c above expected pour point remove the cylinder and tilt it just enough to ascertain whether there is a movement of sample in the Jar* 10* If no movement is noted replace cylinder in holder* The entire operation in Steps 9 and 10 should take only three seconds* 11. Repeat Steps 9 and 10 every 2*o until no movement of sample is noted. When this point is noted hold the sample in a horizontal position for five seconds, by stop watch* DSW 331754 STLCOPCB4078329 ii Standard Analytical Method 053 Hsy 29, 1961 Page 3 of page# 12* If there 1# any movement noted in the five second interval plao sample baok in bath and cool another 2*o before repeating Step# 9 thru 11* 13* The poor point has been reached when no movement is noted for five seoonds. 14 Report the pour point as temperature noted plus 3*e. Addition must be algebraic . Ebss&sb. 1. Observed reading 26*o Pour point 26 3 29*o 2. Observed reading -20*o Pour point -20 3 -17*o DISCUSSION 'Ihe pour point of an oil is the lowest tenperature at which it will pour or flow when it is chilled without disturbance under definite prescribed conditions* BEFKRffiflCS ASTM Method D 97 - 57 ASTM Standards 1958, Part 7, Page 50. oSVM 33^55 STLCOPCB4078330