Document Z8ov4LmdogydrNQrn04dn87BL
Product . Ta*t
Monsanto Ghemical Gompany
Anniacon, Alabama Plant Laboratory
STANDARD ANALYTICAL METHOD
AROCLORS AND PYRANOLS POUR POINT
Mathad Na. , ^53
DATI IISUBD
5/29/61
WRITTEN BY
W.W.K.
I PAOI
| i op
3
| APPROVED BY
I W.W.K.
Thl* Mathed
1~~1 Suparsada* f1 Ravlaos
SCOPE
Instruction* l..u.d On _____ 6/l/l/57
This proosdura deseribas the method for determining the pour point of Aroclors and Pyranols following a modified ASM D-97 procedure
EQUIPMENT
1* Single or four pl&oe Cloud and Pour Test apparatus, ASTH D-97*
2. Test cylinders, pyrtoc, for above.
.
3. Thermometer - ASM No* E-l(5o) Cloud and Pour Test, Range -38*c to +50*c
and ASM No. E-l(6c) Cloud and Pour Test, Low, Range -SO*o to +20*e.
Reagents
1* Methanol or Acetone. 2. Dry ice.
SAFETY
Aroclors and fyranols are irritating to the skin. The Vapors of hot materials are irritating to the eyes and upper respiratory system. If accidental contact 1b made with the eyes, flush inmediately with large quantities of water for at least 15 minutes and get immediate medical attention. The higher Aroclors must be hot to pour, so be careful of thermal burns.
DSW 331753
STLCOPCB4078328
Standard Analytical Method 053 May 29, 1961
Pag 2 of 3 p..
DETERMINATION
1* Select the proper thermometer and oooling bath medium from below 1
Material Aroolor 1262 Aroolor 1260 Aroolor 1254 Aroolor 1242
Thermometer
-38 to +50*o -38 to +50*o
-38 to +50*o
-38 to +50*o
Bath Water Ice-Water Ice-Salt Dry Ioe-Alo*
Approximate Pour Point +38*o
430*0 410* 0
-18*o
Aroolor 1232 Inortsen PPG fyranol 1470
-80 to +20*o -SO to +20*o -80 to +20*o
Dry Ioe-Alo. Dry Ioe-Alo* Dry Ice-Acetone
lower than -30*o
lower than -32*o lower than -44*0
2* Shake the sample well to mix* On the higher Aroolors it will be necessary to heat the aanple to make it fluid enough to mix*
3* Add 2 - 2 l/4 inches of sample to the test cylinder* These depths must be
olosely adhered to.
.
4* Insert the proper thermometer thru a oork or rubber stopper* The thermometer
must be in the center of the stopper*
.
5* Plaoe the thermometer in the test cylinder so that the beginning of the capillary is l/8 inch below the surface of the aaqple. Be sure the therm ometer is in a vertioal position*
6* If the sample had to be heated to pour allow it to oool to &n* 12*0 above
expected pour point before placing in bath* For samples pouring well below room temperature place in bath directly#
7* Adjust the bath to 10* - 15*o below expected pour point*
6* KLaoe teat cylinder and sample in bath holder*
9* When the temperature of the sample is about 10*c above expected pour point remove the cylinder and tilt it just enough to ascertain whether there is a movement of sample in the Jar*
10* If no movement is noted replace cylinder in holder* The entire operation in Steps 9 and 10 should take only three seconds*
11. Repeat Steps 9 and 10 every 2*o until no movement of sample is noted. When this point is noted hold the sample in a horizontal position for five seconds, by stop watch*
DSW 331754
STLCOPCB4078329
ii
Standard Analytical Method 053 Hsy 29, 1961
Page 3 of
page#
12* If there 1# any movement noted in the five second interval plao sample baok in bath and cool another 2*o before repeating Step# 9 thru 11*
13* The poor point has been reached when no movement is noted for five seoonds.
14 Report the pour point as temperature noted plus 3*e. Addition must be
algebraic
.
Ebss&sb.
1. Observed reading 26*o Pour point 26 3 29*o
2. Observed reading -20*o Pour point -20 3 -17*o
DISCUSSION
'Ihe pour point of an oil is the lowest tenperature at which it will pour or flow when it is chilled without disturbance under definite prescribed conditions*
BEFKRffiflCS ASTM Method D 97 - 57
ASTM Standards 1958, Part 7, Page 50.
oSVM 33^55 STLCOPCB4078330