Document Z8jkD4wMV5geLxrQr5QLqL56V
CertainTeed EH
To
See Distribution Below
Subject
Mail Code
From
0. H. Kittilstad
NIOSH RESPIRATOR USER NOTICE - SCBA DEFECT
Mail Code
1125/4
Oate
Ext.
7505
December 4. 1986
TO: N. DiBattista - 0125/2A R. Reeder - 5125/3A J. McGinley - 2125/28 J. Walker - 2125/4 J. Walker - Waco, #616
D. Goforth - Wichita Falls, #402
Please transmit the attached NIOSH memorandum defect notice to your locations that use MSA/NIOSH certified self-contained breathing apparatus (SCBA).
OHK/lh Attachment
><<2
^7
* > / i- CK'SZe-iz- t?
~ ' 3/> : . i
CTD001763
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
August 11, 1986 RESPIRATOR USERS NOTICE
Centers for Disease Control National Institute for Occupational
Safety and Health - ALOSH 944 Chestnut Ridge Road Morgantown, WV 26505--2888
Inspection of Self-contained Breathing Apparatus For Breathing-gas Pressure
The National Institute for Occupational Safety and Health (NIOSH) issued a Respirator Users Notice on January 17, 1986, advising users of Mine Safety and Health Administration (MSHA)/NIOSH-certified self-contained breathing apparatus (SCBA) to inspect fiberglass-wrapped aluminum cylinders at least weekly for breathing-gas cylinder pressure, and discussing the problem of fiber-glass-wrapped aluminum cylinder rupture.
NIOSH issued a Respirator Users Notice on March 15, 1983, advising users of Robertshaw Model 5000 5-minute compressed-air escape SCBA of reports of gradual leakage of air from those respirators. The Robertshaw Model 5000 is equipped with a high-pressure tubing-coil breathing-air reservoir.
NIOSH has identified the following sources of breathing-gas pressure
leakage from SCBA, excluding self-contained self rescuers:
Source of Leakage
No. of Reports to NIOSH
o Cylinder rupture
4
o Cylinder neck cracking
192
o Leakage at the cylinder to
cylinder valve connection
7
o Leakage at tubing--coil
reservoir fittings
50
On the basis of presently-available information concerning the potential for breathing-gas leakage, NIOSH believes that users of all MSHA/NIOSH-certified SCBA should follow these minimum safety
recommendations: 1. Determine that each D0T-E 7235 4500 cylinder is equipped with a steel neck ring to prevent cylinder rupture (DOT-E 7235 2216 and 3000 and other cylinders do not require neck rings). 2. SCBA, except SCSR, which are used infrequently should be visually checked once a week and all SCBA should be checked before donning, for loss of breathing-gas pressure. Failure to conduct such examination could result in a hazardous situation if undetected pressure loss has occurred. 3. SCSR should be inspected as prescribed by MSHA and the SCSR manufacturer. 4. If leakage of breathing gas from an MSHA/NIOSH-certified SCBA or SCSR is observed, have that SCBA or SCSR examined immediately by a qualified service person. If the breathing-gas container is found to be the source of leakage, advise the manufacturer, NIOSH and MSHA (SCSR only) of the problem.
More
CTD001764
Page 2/Inspection of SCBA For Breathing-gas Pressure Cracking of Aluminum Cylinders
The January 17, 1986, Notice also reported the incidence of neck cracking of certain fiber-glass-wrapped aluminum cylinders. The following is a clarification and summary of that report:
NIOSH has received reports of cracks developing in necks of the following fiber-glass-wrapped aluminum cylinders:
DOT-E 7235 2216 cylinders made before January, 1983 DOT-E 7235 4500 cylinders DOT-E 8059 4500 cylinders made before June, 1984 for
SCBA other than USD DOT-E 8059 4500 cylinders made before January 1985 for
USD SCBA NIOSH has also received preliminary reports of cracks developing in the following unwrapped aluminum cylinders:
DOT-SP 6498 2216 cylinders Names and Addresses of Manufacturer's Contacts
Change: Mr. Jay Parker, Pulmosan Safety Equipment Corp., 30-48 Linden Place, Flushing, NY 11354
To: Mr. Robert Bischler, Pulmosan Safety Equipment Corp., C/0 Willson Safety Products, PO Box 622, Reading, PA 19603
Change: Mr. Joel Kaufman, Glendale Optical Company, 130 Crossways Park Drive, Woodbury, NY 11797
To: Mr. Jay Parker, Glendale Optical Company, 130 Crossways Park Drive, Woodbury, NY 11797
/Scfan B. Moran Director Division of Safety Research
CTD001765