Document Z8RR7Jj1wyGY9dkdk6OL2ppL8

RECEIVED SEP 1 3 1991 NORTH AMERICA ASBESTOS INFORMATION ASSOCIATION 1745 Jefferson Davis Highway, Crystal Square 4, Suite 509 Arlington, Virginia 22202 (703) 979-1150 > Jf ; September 11, 1991 Ms. Janis W. Reynolds Director, Industrial Hygiene CertainTeed Corp. P.O. Box 860 Valley Forge, PA 19482-0101 Dear Janis: I have your letter of September 9 along with your completed AIA Dust Measurement Record for 1990. Please disregard my tracer mailing to you and others which went out just yesterday. You have made some excellent points regarding the current format of the DMR and the fact that it does not allow for short term exposure limit exposures which will skew the data reported. I will pass your comments along to the Asbestos International Association with the confidence that it will be revised accordingly. Also, I have advised LHCF of the addition of Mr. Case and Ms. Bixby as participants in the current asbestos fiber counting trial. As always, many thanks for your excellent coorperation and assistance. Sincerely, B. Pigg President cc: Messrs. Ambler McGinley PLAINTIFF'S EXHIBIT CTD026102 CertainTeed Corporation 750 E. Swedesford Road PO Box 860 Valley Forge, PA 19482-0101 215 341-7000 September 9, 1991 V CertainTeed H Mr. B. J. Pigg Asbestos Information Association 1745 Jefferson Davis Highway Crystal Square 4, Suite 509 Arlington, Virginia 22202 Dear Bob: Attached is our completed AIA Dust Measurement Record (DMR) for 1990. As in the past, this information covers our only remaining A/C pipe plant. I do have one concern in reporting this information. As you stated in your letter (dated 8/7/1991) this information is used to demonstrate that worker exposures to asbestos dust continue to decline. Overall, I agree that asbestos exposures are declining, however I am not sure that the information provided in this format is an accurate indicator. As I am sure you are aware, OSHA with the last revision of the asbestos standard, October 1988, amended the standard by adding an excursion limit (EL) of 1 f/cc over a 30 minute sampling period. This short term monitoring is required whenever the asbestos concentration will not be uniform throughout the workday and high concentrations of asbestos reasonably may be expected to be released or created in excess of the EL. To comply with this regulation, we at CertainTeed collect samples during our routine and preventive maintenance projects, which include entering the bag opener and dust collectors. During these jobs our employees are adequately protected using full face HEPA filter respirators and Tyvek coveralls. In most cases, during these excursion level projects the samples become extremely overloaded and uncountable. Those that can be effectively analyzed result in excessive levels. These results are included in the worker's time weighted average (TWA), thus increasing the 8-hour exposure considerably. These types of preventive maintenance projects will always be accomplished in our plant, and will always result in higher fiber concentrations, thus skewing the data for normal day to day manufacturing operations. CTD026103 Mr. B. J. Pigg September 9, 1991 Page 2 I'm sure other participating companies in the U.S. are aware of this situation, however, I'm not sure the international members collect samples in the same manner. Perhaps a more thorough questionnaire would take into consideration this excursion limit problem and help to better classify this information. As a minimum, I suggest that TWA's containing excursion limit samples, primarily maintenance operations, be classified separately. As an added note, I have received the slides for this years fiber counting trial. Three of us will be participating in this trial, myself and two new industrial hygienist. Their names were not originally included on the registration form sent to LHCF in May. They are Mr. Tom Case and Ms. Martha Bixby. Thank you for including CertainTeed in this survey and the fiber counting trial. ^ i nnorol \r Janis W. Reynolds Director, Industrial Hygiene Attachments cc: J. McGinley - 2125/2B L. Amber - 2125/2B CTD026104 The Asbcsios International Association for environmental and occupational health protection wherever asbestos or other fibres are used for the same purposes A.I.A. DUST MEASUREMENT RECORD (DM R) 1 990 (Guidance for completing the form is provided in annex) Please complete this enquiry anonymously, using a separate form for each factory under your control, and return them promptly to: Asbestos Information Association 1745 Jefferson Davis Highway Arlington, Virginia 22202 Crystal Square, Suite 509 U.S.A. 1. IDENTIFY INDIVIDUAL FACTROY PRODUCT GROUP Total Workers Workforce Under survey Mines/Hills............. Asbestos-Cement... Friction Materials Textiles................... Others (specify).. 48 45 2. STATE WHICH FIBROUS MATERIALS ABE BEING USED Chrystotile..................................... _ Amphibole (specify).. MMMF Aramids, etc..(specify belov) (1) 3. WHAT ARE YOUR NATIONAL COUNTBOL STANDARDS Chrystotile..................................... Amphibole (specify).................... MMMF Aramids, etc..(specify belov) (2) 0.2 f/cc* 0.2 f/cc* 4. WHICH SAMPLING AMD FIBRE COUNTING METHOD IS USED RTM1.............................. ERM................................ NIOSH......................... OTHER (specify)----- x (1) Mark vith a cross as appropriate (2) Complete with Units as appropriate NOTE: 8hr. permissible exposure limit (PEL) established by the united states occupational safety & health administration (OSHA). We also have an excursion level (EL) of 1 f/cc for 30 minutes CTD026105 5. STATE YOUR NORMAL SAMPLING DURATION 6. DOBS YOUR COUNTING LABORATORY TAKE PAST IK A QUALITY CONTROL SCHEME A.I.A. (Fibre Counting Trial)................ Your ovn laboratory scheme....................... Others (specify). John.Hopkins .Univ.e.r.s.ity Round Robin 7. DO YOU CARRY OUT GRAVIMETRIC SAMPLING IF YES STATE FOR WHICH SUBSTANCES (2) Approx. 400 min. <-- Several Individual short term samples totallin; 8. DISTRIBUTION OF MONITORING DATA FOR THB CURRENT CALENDAR YEAR 1990 Class F/cm3 PERSONAL SAMPLES NUMBER STATIC WORKERS SAMPLES IN THE CLASS C<=0.1 0.1<C<=0.2 0.2<C<=0.3 0.3<C<=0.4 51 3 2 40 2 2 0.4<C<=0.5 0.5<C<=0.6 1 1 0.6<C<=0.7 0.7<C<=0.8 0.8<C<=0.9 0.9<C<=1.0 1.0<C<=2.0 02.0 in *3- TOTAL NUMBER 57 0 (*) Should equal number of workers under survey as in para 1 9. INDICATE WHETHER PERSONS EXPOSED IN EXCESS OF EXISTING CONTROL STANDARDS ARE PROVIDED WITH RESPIRATORS 10 ARE THERE ANY BELATED WATTERS WHICH YOU REQUIRE ASSISTANCE WITH Yes/No 1 Yes Yes/No No I (1) Hark with a rrnss as annrnririst-o CTD026106 <1 < r 'Z V 7 fi% 2^ ^ <*3 "3 ^.f- o <S / / (_? v?% 5 2/ 5% r tlfo ^ -2_ O / *% 57 CTD026107 The Asbcslos International Association forcnvlronmcntal and occupational health protection wherever asbestos or other fibres arc used for the same purposes A.I.A. DUST MEASUREMENT RECORD (DM R) 1 9 90 (Guidance for completing the form is provided in annex) Please complete this enquiry anonymously, using a separate form for each factory under your control, and return them promptly to: Asbestos Information Association 1745 Jefferson Davis Highway Arlington, Virginia 22202 Crystal Square, Suite 509 U.S.A. 1. IDENTIFY INDIVIDUAL FACTROY PRODUCT GROUP Total Workers Workforce Under survey Mines/Mills............. Asbestos-Cement... Friction Materials Textiles................... Others (specify).. 4^ 2. STATE WHICH FIBROUS MATERIALS ARR BEING USED Chrystotile.......................... .......... Amphibole (specify) /Z&ff-i&l'tcMMMF Aramids, etc..(specify below) (1) 3. WHAT ABE YOUR NATIONAL COUNTROL STANDARDS Chrystotile...................................... Amphibole (specify)..................... MMMF Aramids, etc..(specify below) (2) O' & 4. WHICH SAMPLING AND FIBRE COUNTING METHOD IS USED RTM1.............................. ERM................................. NIOSH............................ OTHER (specify)----- (1) Mark with a cross as appropriate (2) Complete with units as appropriate HhtJonr: Sir sdte&r X . CTD026108 JftKf y/M). STATE YOUR NORMAL SAMPLING DURATION (2) i UvUMurt4---- ------------__ Sheer (A I ^*fOO POES YOUR COUNTING LABORATORY TAKE PAST IN A QUALITY CONTROL SCHEME `* A.I.A. (Fibre Counting Trial)................ Your own laboratory scheme..,...*-... ^ Others (specif 2-C^'C^Ol^^-f 7Z~ 7Z DO YOU CARRY OUT GRAVIMETRIC SAMPLING IF YES STATE FOR VHICH SUBSTANCES Yes/No 8. DISTRIBUTION OF HONITORING DATA FOR THE CURRENT CALENDAR YEAR /m .3 - O- n#j M* 1990 Class F/cm3 C<=0.1 0.1<C<=0.2 0.2<C<=0.3 0.3<C<=0.4 PERSONAL SAMPLES 5) 3 NUMBER STATIC WORKERS SAMPLES IN THE CLASS 2Z 0.4<C<=0.5 0.5<C<=0.6 I / 0.6<C<=0.7 0.7<C<=0.8 0.8<C<=0.9 0.9<C<=1.0 1.0<C<=2.0 02.0 TOTAL NUMBER 3l . O <*> (*) Should equal number of workers under survey as in para 1 9. INDICATE WHETHER PERSONS EXPOSED IN EXCESS OF EXISTING CONTROL STANDARDS ARE PROVIDED WITH RESPIRATORS Yes/No 10 ARE THERE ANY RELATED MATTERS WHICH YOU REQUIRE ASSISTANCE WITH (1) Hark with a ernss as annrnr>ri ato CTD026109 4^-8ktfcc^S b~! S J<j I TABLE V CURRENT RIVERSIDE EMPLOYEES (9/8/90) DATE OF LAST OFFICIAL EXPOSURE MONITORING EVANS, GEORGE BRADY, JEFF ASKEW, U HAMILTON, CHRIS JALL, BUD BRYANT, BIRK BARCIA, MONTE BANDERS, ANZY 3TAHFIELD, DICK JILSON, CHARLES HARRON, DOUG BONCRANT, GLEN IORRAL, RICHARD .EDFORD, JOE (ESCHLIMAN, KEN .OLIE, KEVIN BOLE, HARRY (ARTINEZ, PETE IIVENS, JANET I1L, L (ORGAN, JU 'ANDERTWELL CONTRERAS, JOE /1LLAPAND0, A 'LAZA, MANUAL IEIER, STEVEN :UAREZ, ANDRES iVERY, ALBERT ANTRELL, N OOSE, DENNIS IICHEL, ROBERTO IORALES, D ENFRO, E EYES, P LAUSON, J OGLEY, DENNIS OOPER, H OBBS, P .ALVIN, DENNIS OOOWIN, L RANILLO, B ASILLAS, DAVE ASTAAINS, HENRY ARRON, A HUTE, GAIL CFANN, JOE ERRY, DALE HI TAKER, UOOOROU LATHE OPERATOR PRESS OPERATOR MIXER OPERATOR FITTINGS MAKER STOREROOM CLERK LOADER INSPECTOR FITTINGS TRUCK OPERATOR FORKLIFT-EATHE FITTINGS INSPECTOR F.eL.teF' STRIPPER WET TESTER / TRAY LOADER/TAT WCU OfgfL MACHINE TENDER PRESS OPERATOR TRAY LOADER/^BfeMCAC a/teA. STRIPPER TRUCK OPERATOR SHIPPING LG FH LATHE OPERATOR FORKLIFT-SHIPPING MftCfWNtC Of*A. WET-TESTER- PRESS OPERATOR MANDREL HANDLER TRAY LOADER PIPE HANDLER LATHE OPERATOR MANDREL HANDLER TRAY LOADER MECHANIC MACHINE TENDER RELIEF OPERATOR MIXER OPERATOR REWORK SAW COUPLING CUT OFF PIPE HANDLER , Bomwe iitll iver T<e$i-eA. --CRUSHER-- O 1/A LATHE OPERATOR OCUB TECHNICIAN LATHE OPERATOR MECHANIC MECHANIC MECHANIC - FORKLIFT MECHANIC MAINTENANCE J9B5R An MAINTENANCE 870811 HEDICAL LEAVE 870812 MEDICAL LEAVE 880824 900330 900330 900331 900331 900331 900331 900331 900522 900522 900530 900530 900601 900604 900605 900605 900614 900621 900626 900708 900719 900731 900801 900815 900815 900906 900906 900906 900906 900906 900906 900906 900907 900907 900907 900907 900907 900907 900907 900907 900908 900908 900908 900908 900908 900908 CTD026110 Asbestos OSHA. ' EL = 0.2 F/CC 1986 - 1991 f // 1/ .</> ^ PAGE 1 SOC SEC # TYPE DATE TWAj HIM LOCATION PROCESS JOB PPG RIVERSIDE 118225805 P 03/30/90 0.017 435 266827813 P 03/30/90 ,,0.029 435 SHIPPING LOADER./ 422569672 P 03/30/90 lo. OOO-- 0 FINISHNG INSPECTO / 457602925 P 03/30/90 0.044 420 CPLGCOFF OPERATOR / 555745800 P 557568670 P 03/30/90 03/30/90 /3.201 0.049 455 460 ser OPERATOR/ TT/oA-'/ 422569672 P 03/31/90 0.047 440 FINISHNG INSPECTO/ 431640728 P 03/31/90 0.019 431 527506060 P 03/31/90 0 FINISHNG INSPECTO/ 546766926 P 03/31/90 0.077 437 LATHE1/4 OPERATOR. 548583160 P 03/31/90 0.010 434 002220623 P 04/01/90 0.011 318 107323415 P 04/01/90 0.031 448 294404086 P 04/01/90 +- 0.290 417 GENERAL MECHANIC / 567465755 P 04/01/90 0.013 449 ./ 999992837 P 04/01/90 0.018 446 568086676 P 09/06/90 0.011 477 TRAYLOAD operator/ 558494568 P 09/06/90 0.022 474 GENERAL mechanic/ 553545445 P 09/06/90 0.049 454*-PIPEMACH RELIEF 550521674 P 09/06/90 0.048 410 GENERAL mechanic/ 572820787 P 09/06/90 0.018 398 liATHLINE OPERATOR 554729301 P 09/06/90 0.081 469 -SAWREWRK OPERATOR 560046091 P 09/06/90 0.045 437 MIXER OPERATOR 549526935 P 09/06/90 0.096 440 'PIPEMACH TENDER 560486590 P 09/06/90 ^0.167 464 CRUSHER operator/ 572643309 P 09/06/90 /0.107 439 MANDREL HANDLER 557568670 P 09/07/90 0.027 443 LAB TECHNICI / 568133118 P 09/07/90 0.056 426 TiATHLINE HANDLER 562745496 P 09/07/90 0.050 435 LATHLINE OPERATOR / 546766926 P 09/07/90 0.032 418 LATHE1/4 OPERATOR V/ 557681875 P 09/07/90 0.033 440 BORGMILL OPERATOR 554729301 P 09/07/90 0.086 416 SAWREWRK OPERATOR 560486590 P 09/07/90 0.039 443 CRUSHER operator/. 344303938 P 09/07/90 0.039 432 CPLGCOFF operator/ 092309537 P 09/08/90 0.005 486 GENERAL MECHANIC / 550521674 P -09/08/90 + 0.283 483 GENERAL MECHANIC-^ 567465755 P 09/08/90 0.014 490 GENERAL MECHANIC'/ 327268652 P 09/08/90 0.013 481 GENERAL MECHANIC/ 002220623 P 09/08/90 0iO14 490 GENERAL MECHANIC/ 557568797 P 09/08/90 0s-O47 489 GENERAL mechanic/ 294404086 P 09/08/90 ftf.420^P287 GENERAL MECHANIC / 573760128 P Oi/26/91 mLjBTY T5T PtPEMACH TENDER 561904679 P 02/26/91 0.174 460 MIXER OPERATOR 555620421 P 02/26/91 0.110 453 CRUSHER OPERATOR 568428810 P 02/26/91 0.035 241 PRESS OPERATOR 570582582 P 02/26/91 0.034 105 MANDREL HANDLER 385220170 P 02/26/91 0.012 455 PIPEMACH STRIPPER 440340878 P 02/26/91 0.017 457 TRAYLOAD OPERATOR 550788997 P 02/26/91 0.079 424 MANUFACT RELIEF 548583160 P 02/26/91 0.039 382 FINISHNG LINES1/3 FORKLIFT 344303938 P 02/26/91 0.162 494 CPLGCOFF OPERATOR 554729301 P 02/26/91 0.185 463 SAWREWRK LINE1 OPERATOR 2 MOlD CTD026111 Interoffice Memo CertainleedEi To Mail Code 7^------------- ------------------------- Mail Code Ext Jim Burke Subject 260 Janis Reynolds 1125/4 Oale 7713 Riverside Asbestos Air Sample Results August 17 , 1990 cc: Lee Todd - 260 Below, I have listed the results of the air samples taken at your plant by L. Todd during the period 5/22 to 7/18/90. NAME POSITION DATE TWA (f/cc)* Glen Soncrant Doug Marron Richard Corral Joe Ledford Ken Aeschliman Kevin Lolie Pete Martinez Harry Cole Janet Bivens Larry Gil J. W. Morgan Homer Cooper Joe Contreras Stripper Operator Machine Tender Wet Tester Operator Truck Oper./Tray Load. Machine Tender Press Operator Stripper Operator Truck Oper./Tray Load. Shipping Truck Oper. Large FM Lathe Oper. Shipping Truck Oper Pipe Handler Wet Tester Operator 5/22/90 5/22/90 5/30/90 5/30/90 6/1/90 6/4/90 6/5/90 6/5/90 6/14/90 6/21/90 6/26/90 7/17/90 7/18/90 >0.013 >0.053 > 0.010 0.005 >0.04 >0.047 t o.ooa >0.006 0.022 0.006 0.005 0.037 0.02 *Sample concentrations preceded by a greater than sign (>) indicate that the result may be an underestimation due to heavy particulate loading on the filter. I am sorry for the delay in getting the results to you. I had been waiting to input them in our new computer system, however it's start-up has been delayed. When it is completed, I'm sure we will have a better turn around time. Please inform these employees of their results. Thanks! 01-25-0005 3/89 CTD026112 Jim Burke 260 Janis Reynolds Riverside Asbestos Air Sample Results 1125/4 7713 August 28, 1990 cc: Lee Todd - 260 Below, I have listed the results of the air samples taken at your plant by L. Todd during the period 7/31 to 8/15/90. NAME A. Villapando Dale Perry Manual Plaza Andy Suarez Steve Meier POSITION Press Operator Oiler Mandrel Handler Pipe Handler Tray Loader DATE 7/31/90 8/1/90 8/1/90 8/15/90 8/15/90 TWA (f/cc)* 0.06 0.03 0.03 0.003 0.006 / As you can see, these results are all below the proposed 0.01 f/cc OSHA limit. Please inform these employees of their results. Thanks! LO' 4^ ,V -Is O l\ < C7D026113 ACTION Subject MEMO \S See attached fifiolDlSGUSSION ,-, - RECEIVED AUG 1 6 1991 TO /is. JAj>s AS'/vetas PROM J~.fi. H c Gr-f <JU1 c y/ DATE 2 Irfv RETURN BY FORWARD TO -^--s--r-/--h--u--t-T^7---J--~--/-A---x----A--s--f--c----j->----A--llE------T--&-----f--i-v---/-l--^---j-A----^----r--u--,-s-----7---0-------- ypp f~o //A-f-JbLt&C: //- /4 Ai<ist. f-ayiSyA C A-<S><jSrT~ /<S L^AAAJUjt^^ Al.AS- /Oo<-Q. A'^/O fitcAA-Q/ CTD026114 To_______________________________ DateTime WHILE YOU WERE OUT Message 01-19-0015 12/89 Operotor CTD026115 m ASBESTOS INFORMATION ASSOCIATION &. / *t\ ICiR 1 1745 Jefferson Davis Highway, Crystal Square 4, Suite 509 Arlington, Virginia 22202 (703) 979-1150 FAX (703) 979-1152 -Jo August 7, 1991 Memorandum For: AIA/NA Members (less Canadian Producers) Subject: Dust Measurement Record (DMR) 1990 (Asbestos International Association) Please find enclosed a copy of the Asbestos International Association's (AIA) letter dated July 29, 1991 and attachments thereto. It will be recalled from previous efforts of this nature that the AIA, with approval of its Governing Council, has collected data on dust levels in factories and mines and mills from companies belonging to national associations that are members of the Asbestos International Association. Surveys were conducted for the years 1983-1989. This survey applies to 1990. It is understood that the asbestos producers in Canada will be participating in this survey through The Asbestos Institute. AIA/NA members and other interested companies that have participated in prior surveys include the following for which sincere appreciation is extended: Allied-Signal (Bendix) CAPCO Pipe Company CertainTeed DISTEX Durabla Ferodo America Henry Company Grundy Industries KCAC Monsey Products Supradur Vermont Asbestos Group Accordingly, AIA/NA members (less Canadian producers) are requested to give close attention to the enclosures at your earliest convenience. Return of the AIA DUST MEASUREMENT RECORD (DMR) 1990 to this office by September 24, 1991 would allow for collation and transmission to AIA within the timeframe requested. One of the principal RECEIVED AUG 12 1991 CTD026116 page 2 uses of this survey is to demonstrate before various international bodies and forums that worker exposures to asbestos dust continue to decline as a result of responsible efforts by the asbestos industry. By copy of this memorandum, we invite and encourage companies who are not members of this Association, but have made financial contributions to our work, to participate in this important survey. Thank you in advance for your assistance. Please let us know should you have questions or if we can be of help in any way. d. j. riyy President Enclosures cc: AIA/NA Contributors Daniel Bouige, AIA (less ends) Michel Gratton, Al (less ends) CTD026117 A\n/A Tbc Asbestos International Association for environmental and occupational health protection wherever asbestos or other fibres are used for the same purposes AIA/20/2/12/HAS AIA/1/4/8/1/POL TO : All Associate Members Date : July 29, 1991 FROM : D. Bouige SUBJECT : AIA DUST MEASUREMENT RECORDS Attached please find the complete report on the 1989 A.I.A. Dust Measurement Records (DMR's) together with an enquiry form on the 1990 A.I.A. Dust Measurement Records. Please distribute the enquiry to your Associate Members and return the duly completed form to the A.I.A. before 30 September, 1991. Thank you for your attention and best regards, rr. Please note your country code is : 3 CTD026118 ANNEX TO 1990 DMR FORMS NOTES EOR GUIDANCE WHEN COMPLETING THE DUST MEASUREMENT RECORD (DMR) The DMR is confidential and only an AIA composite report will be made public. Individual factories and companies will not be disclosed. The total workforce referred to in Question 1 should include all personnel on the pay roll including: office staff, etc. The "workers under survey" referred to in question 1 are the number of workers to whom an exposure index is assigned in the factory records. The enquiry about laboratory control schemes referred to in question 6 reflects the importance of this issue and all laboratories carrying: out analysis should take part in a well constructed scheme. The AIA counting trial is available to all AIA member associations. The table 8 requests information about the monitoring data obtained over the year : - Personal samples are intended to monitor exposure or individual persons and tire attached to the person being monitored. - Static samples are used to measure general dust levels and are used for engineering control purposes. - The column headed "Workers in the Class" refers to the number of persons allocated to each class of measurement. For instance if a sample is taken to represent a work group of 10 persons, because their work practices are identical the entry should be 10 and not 1. Considerable care is necessary when deciding upon group representation of this - nature. Most workers have individual work practices which greatly influence exposure. If there is good reason to report results in section (8) as separate groups, e.g. persons working only with glass wool and no asbestos etc. then it is permissible to submit that group on a separate and full recorded sheet. CTD026119