Document Z8Bm4njqXkZO22LV13L1w2w98

PLAINTIFF'S EXHIBIT It,,w , SUNBEAM GRAVITY FURNACES WINTER AIR CONDITIONERS Price Book SE-3 DECEMBER 6, 1948 VOTICE The Trade Prices shoicri herein do not include freight or cartage Page GENERAL TERMS................................................ 2 FURNACE SELECTION INFORMATION......... 3 SUNBEAM GRAVITY FURNACES................... . .. 4-8 SUNBEAM FLOOR FURNACES........................ 9 SUNBEAM WINTER AIR CONDITIONERS. .. ...10-15 ARCOFLAME OIL BURNERS............................. . .16-17 GAS CONVERSION BURNERS......................... . . 18 SUNBEAM BLOWER-FILTER UNITS............... 18 AIR FILTERS......................................................... 18 AUXILIARY WATER HEATER COILS............ 18 HUMIDIFYING EQUIPMENT............................. 19 TEMPERATURE CONTROL EQUIPMENT...... 20 i American n <^tadai*d Radiator & ^aiuta*# CORPORATION Pittsburgh 30, Pa. 04130 General Terms AMERiCA\-c$*tat?dard HEATING EQUIPMENT General Terms 1 (lustrations and descriptions of Plate Numbers listed m the price book will be found m the Warm Air Heating Equipment Section of the ''AMERICAN-STANDARD" GENERAL CATALOGUE. Items illustrated m the GENERAL CATALOGUE and not included m this price book are discontinued. Items added since the issuance of the last Catalogue Revision are described for identification. PRICES All prices herein quoted supersede all prior quotations and are subject to change with out notice. No obligation is assumed by this Corporation to sell to any one holding this book any of the items listed herein at the prices stated. A minimum invoice charge of forty-five cents (.45) will apply on any item including repair parts. TAXES To the prices and terms Quoted add any Manufacturers' or Sales Tax payable on the transaction under any effective statute. TRANSPORTATION CLAIMS The responsibility of this Corporation ceases upon delivery of goods m good order to transportation companies, and all goods are shipped at consignees' risk. OROERS The Corporation shall not be liable for any delay or failure in the delivery or shipment of products or for any damages suffered by reason of such delay or failure, when such delay or failure is, directly or indirectly, due to fire, flood, accidents, riots, war, embargo, labor stoppages, inadequate transportation facilities, shortage of material or supplies, regulation by Governmental authority, or any cause or causes beyond this Corporation's control. GUARANTEE We guarantee goods manufactured by this Corporation to the extent that we shall fur nish by freight new parts for any parts of such goods found defective in workmanship or material. No claim for labor in replacing defective parts or other consequential damage will be allowed. All replacement parts for material claimed defective will be invoiced in the usual manner, such invoice being subject to adjustment after alleged defective material has been returned to the Plant for inspection. No materials are to be returned without written permission. Goods of other manufacturers sold by us are not guaranteed by this Corporation. CLAIMS No claims under the above guarantee, or for variances from or shortages in orders will be allowed, unless presented within sixty (60) days after receipt of goods. SPECIAL PRODUCTS Items of special nature or products requiring special manufacture or supervision are not subject to change or cancellation after production is started. RETURNED GOODS Good material of standard manufacture must not be returned for credit without first securing written permission, and when so returned will be subject to a deduction of 109c for re-handling, and all transportation charges, including freight and cartage, will be paid by shipper. Materials made on special order are not subject to return. SHIPPING WEIGHTS Weights are for customers' convenience only, are approximate and not guaranteed. SE-3 2 Furnace I nformat S:.a- 0r 23U 0 r, t - h 2 : one fee scuare me: Too Exa m R c 21 s i e-r 5 B:*j C- Biu Cse; Btj C. Qic' q: r. 04131 eneral Terms Furnace Selection Information Amirican-c$tadai*d HEATING EQUIPMENT Furnace Selection Information aiII be found in ?D"GENERAL 'Ot included m last Catalogue Converting Requirements in Square Inches to Btu o change withj this book any t including re payable on the good order to y or shipment re, when such war, embargo, t! or supplies, Corporation's i i i Capacities at Registers Square Inch Ratings shown for all Sunbeam Gravity Furnaces are based on approximately one-half of capacity being supplied to first floor and one-half to second floor. For conditions where entire demand is all on one floor, or is substantially greater on one floor than the other, convert the square inch requirements of the installation into Btu by the following method: Multiply square inch requirements of first floor by 111 ; Multiply square inch requirements of second floor by 167; Add the results and select Furnace having Btu capacity at register equal to or greater than the total. Examples: 1. Assume one story building requires 675 square inches of leader pipe: 675 x 111 = 74,925 Btu at registers we shall furworkmanship ential damage II be invoiced -ged defective o be returned ot guaranteed in orders will vision are not without first ction of 10% tage, will be tranteed. 2. Assume two story building with furnace heating only second floor requires 390 square inches of leader pipe: 390 x 167 = 65,130 Btu at registers 3. Assume two story building requires 565 square inches of leader pipe on first floor, and 185 square inches on second floor: 565 x 111 = 62,715 Btu at registers -- first floor 185 x 167 = 30,895 Btu at registers -- second floor 93,610 Total Btu at registers Ratings Square Inch Ratings are calculated by dividing the Btu Capacity at Registers by 136. Btu Capacity at Registers for all Sunbeam Gravity Furnaces is 75% of Btu Capacity at Bonnet. Btu Capacity at Registers for all Sunbeam Winter Air Conditioners is 85% of Btu Capacity at Bonnet. 3 SE-3 Hand Fired American - Standard heating equipment Sunbeam Furnaces SUNBEAM HAND FIRED FURNACES CAST IRON Catalogue Page SI-6 KENWOOD Cast Iron Pipe Furnace Furnace Number D.am. Fire Pot t tRatmg Square Inches 8tu Capacity at Registers Furnace Only T rade Prices Approx. Shipping Weignt Casmg and Hood Trade Prices Approx. Shipping Weight Furnace with Casmg and Hood T rade Prices Anorox. Shipping Weight A-1018-CO A-1040-CD A-1044-CO A-I048-CO A-I052-CD 18' 20' 22' 24' 26' 390 53.000 SIOT 00 699 $ 9 00 467 63,500 109 50 835 11 50 56 $M0 00 68 12' 00 75k5* 903 537 73.000 123 70 965 13 80 74 137 50 1039 597 81,200 1 38 40 1076 15 60 > 80 15* 00 1156 683 92,900 168 10 1376 18 90 92 187 00 1 468 STANDARO EQUIPMENT--Check draft, finishing collars, poker, draft regulator, chain and pulleys, asoestos cement, nuts and bolts. NOTE: Cone type hoods are regularly furnished. Flat top or one pipe type hoods furnished when ordered without extra charge. tSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO 8TU CAPACITIES AT REGISTERS." KENWOOD Cast Iron Pipeless Furnace Furnace Number Diameter Fire Pot 6tu Capacity Trade Prices Complete Approximate Shipping Weight A-1018-BO A-1040-8O A-1 044-60 A-1048-BO A-1052-8D 18' 20' 22' 24' 26' 70,700 84,700 97,300 108,100 123,800 $137 00 160 00 185 50 209 00 239.00 916 1121 1266 1410 1737 STANDARD EQUIPMENT--Register, check draft, poker, draft regulator, cham and pulleys, asbestos cement, nuts and bolts, warm-air and return-air extensions. NOTE: Duplex Grates are regularly furnished with Kenwood Pipe and Pipeless Furnaces Triangular Grates are available at no additional charge, when ordered, specify with suffixes "CT" or ''ST", instead of "CD" Of "BD", respectively. ARLINGTON Steel Pipeless Furnace Furnace Number Diameter Shell Stu Capacity Trade Prices Complete Approximate Shipping Weight BD-520 20' 90.500 $159 00 1102 80-522 22' 112.800 177 00 1157 80-524 24' 126,200 207 00 1255 80-527 27' 134,500 239 00 1369 STANDARD EQUIPMENT--Register, check draft, poker, draft regulator, cham and pulleys, asbestos cement, nuts and bolts, warm-nr and return-air extensions. SEE PAGE 18 FOR AUXILIARY WATER HEATER COILS. PAGE 19 FOR HUMIDIFYING EQUIP MENT, PAGE 20 FOR TEMPERATURE CONTROL EQUIPMENT. NOTE: Deduct 5% from price of Cast Iron or Steel Furnace Only, respectively, for omission of Grate Assembly, Ashpit Door, and Hand Firing Accessories. SE-3 Sunbeam I i ' ' ' ru'nace Numoer 0.520 0-`552?74 ------------------------ STANDARO nuts and do::s Furnace Numoer D-8030 C-8034 STANDARD nuis and Dolts I F i uce N 'ber 0-520-SC D-522-SC D-524-SC 0-527-SQ STANDAPC draft regulator NOTE De' Firing Accassc NOTE Cor type hoods f nr with straight j SEE PAGE REGISTERS * SEE PAGE MENT PAG: 04133 tm Furnaces Furnace with ii>ng and Hood Approx. ade Shipping ces Weight 0 00 1 00 7 50 4 00 7.00 755 903 1039 1156 1468 ain and pulleys, sd when ordered APAClTlES AT Approximate uppmg Weight 916 1121 1266 1410 1737 'uiieys, aabeatoa :e Triangular BT", instead of Approximate uppmg Weight 1102 115? 1255 1369 uMeys, asbestos 'YING EQUIP- mission of Grate \ Sunbeam Furnaces A^RiCAN-c^tacdard heating equipment Hand Fired F urnace Number SUNBEAM HAND FIRED FURNACES ARLINGTON Steel Pipe Furnace Catalogue Page ST-10 GALVANIZED ROUND CASING Diam. Shell f (Rating Square Inches Btu Capacity at Registers Furnace Only Casing and Hood Furnace with Casing and Hood Trade Prices Approx. Approx. Shipping Trade Shipping Weight Prices Weight Trade Prices Approx. Shipping Weight D-520 20* 499 67,000 (102 40 009 (12 60 70 (115 00 875 D-522 22* 622 04,600 115 20 056 13 80 75 129 00 931 D-S24 24* 696 94,600 136 40 921 15 60 77 152 00 990 0-527 27* 741 100,000 160 30 1021 17 70 81 106 00 1102 STANOARO EQUIPMENT--Check draft, finishing collars, poker, draft regulator, chain and pulleys, nuts and poits.______ __________________________________ ^________ Furnace Number Diam. Shell CLIFTON Steel Pipe Furnace Catalogue Page SJ3-I5, 17 GALVANIZED ROUND CASING ttRitmg Capacity Square at Inches Registers Furnace Only Casing and Hood Furnace with Casing and Hood Trade Prices Approx. Approx. Shipping Trade Shipping Weight Prices Weight Trade Prices Approx. Shipping Weight D-8030 30* 943 128,200 1225 50 1375 (21 50 101 $247 00 1476 C-S034 34* 1,024 139,300 300 50 1553 24 50 113 325 00 1666 STANOARO EQUIPMENT--Check draft, finishing coffers, poker, draft regulator, chain and pulleys, nuts and bolts. Smoke Tees for Clifton Steel Furnaces: 10* (for 6030, 80341 $4.00 Trade Price ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page ST 1-12 SQUARE METAL JACKET Furnace With Square Jacket and Flat Hood / Furnace Diameter t+Ratmg Btu Capacity Number Shell Square Inches at Registers Approx. Trade Shipping Prices Weight D-520-SQ D-522-SO 0-524-SQ D-527-SQ 20* 22' 24* 27* 499 67,000 (126 00 1059 622 64,600 142 00 1115 696 94,600 162 00 1205 741 100,800 197 00 1317 STANDARD EQUIPMENT--Squire Metal Jacket with inner liner, check draft, finishing collars, poker, draft regulator, chain and pulleys, nuts and bolts. NOTE: Deduct 5% from price of Furnaee Only for omission of Grate Assembly, Ashpit Door, and Hand i Finna Accessories. NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered without extra charge. The Arlington "Squire" Model is furnished only j with straight side Hat top hood which is a part of the ticket. 1 HSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS." SEE PAGE 18 FOR AUXILIARY WATER HEATER COILS. PAGE 19 FOR HUMIDIFYING EQUIP MENT; PAGE 20 FOR TEMPERATURE CONTROL EQUIPMENT. 5 SE-3 Oil Fired American-Standard heating equipment Sunbeam Furnaces Furnace Number SUNBEAM OIL FIRED FURNACES ARLINGTON Steel Pipe Furnace Catalogue Page S7-10 GALVANIZED ROUND CASING tt Btu Diam. Rating Capacity Shell Square at Inches Registers Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood T rade Prices Approx. Shipping Weight 0-520-G or R D-522-G or R 0-524-G or R D-527-G or R 20' 22' 24' 27' 596 81,000 $102.40 601 $12.60 622 64,600 115 20 627 13 80 696 94,600 136 40 656 15 60 741 100,800 168 30 730 17 70 70 $115.00 671 75 129 00 702 77 152 00 733 81 186 00 811 Furnace Number CLIFTON Steel Pipe Furnace Catalogue Page SI 3-17 GALVANIZED ROUND CASING Diam. Shell M Btu Rating Capacity Souare at Inches Registers Furnace Only Trade Prices Approx. Shioping We.Qht Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Shipping Weight D-603O-G or R G-8034-G or R 30' 34' 943 1024 128,200 $225 50 139,300 300.50 948 1057 $21 50 24 50 101 $247 00 1049 113 325 00 1170 Smoke Tmi for Clifton Stool Furnaces: 10' (for 8030, 8034) $4.00 Trade Price Furnace Number D-520-SQG or S<?R D-522-SgG or S< >R 0-524-SOG or S< >R 0-527-SQG or SC>R ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page Sll-12 _____________ SQUARE METAL JACKET______________ Diam. Shell tt Rating Square 1nches Btu Capacity at Registers Furnace with Square Jacket and Fla t Hood Trade Prices Approx. Shipping Weight 20' 596 81,000 $126 00 883 22' 622 64,600 142.00 916 24' 696 94,600 162 00 978 27' 741 100,800 197 00 1068 IMPORTANT: When ordering specify whether for use with Gun (G) or Rolary (R) Type Burner. Grates and Fire Brick are not furnished. Special fire doors and burner doors are supplied. For Gun Type Burners, furnaces will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, furnaces will be equipped with cast iron hearth rings and brackets, hearth plate, fire box liners and mineral wool insulation. NOTE: Sufficient space is not available on the standard hood for the total rating to be used by a number of small pipe take-offs. For such a condition 12' pipe take-offs with "Y" connections may be used. NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered, without extra charge. The Arlington "Square" is furnished only with straight aide flat too hood which is a part of the iacket. ttSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS." SEE PAGE 16 FOR ARCOFLAME OIL BURNERS AND CONTROLS, PAGE 17 FOR CORRECT SIZE ARCOFLAME OIL BURNERS TO BE USED WITH THESE UNITS, PAGE 19 FOR HUMIDIFYING EQUIPMENT. SE-3 6 Sunbeam Furnaces SUNE F urnace Number Oum, Shell t* Rat,-' Souar, Inche: tD-520-SA tD-522-SA D-524-SA D-527-SA 20' 22* 24' 27' 596 622 696 741 Furnace N u mber O'am Shell ---- Rat-r Saua1 nche D-8030-SA C-8034-SA 30' 34' 94 3 102* AP Furnace Number tO-520-SQS TO-522-SQS D-524-SQS 0-527-SQS Furnace is equipped with t* and supports. Metal plates ir When stoker is to be ir>sta hand fired models as shown o tNOTE: These sites eauipp' NOTE: Sufficient apace is of small pipe take-offs. For s>. NOTE: Cone type hoods a-f type hoods furnished when c straight aide flat top hood ri ttSEE PAGE 3--"CONVERi REGISTERS." SEE PAGE 18 FOR Au X: MENT. 04135 am Furnaces Furnace with asmg and Hood rade nces Approx Shippm Weight 15 00 29 00 52 00 36.00 671 702 733 81 1 Sunbeam Furnaces American-c$tat?dard heating equipment Stoker Fired F urnace Number SUNBEAM STOKER FIRED FURNACES ARLINGTON Steel Pipe Furnace Catalogue Page S7-10 galvanized round casing Diim. Shell tt Rating Square inches Btu Capacity at Registere Furnace Only Trade Prices Approx. Shipping Weight Casing and Hood Trade Prices Approx. Shipping Weight Furnace with Casing and Hood Trade Prices Approx. Snipping Weight D-520-SA tO-522-SA 0-524-SA 0-527-SA 20* 22' 24' 27' 596 81,000 $102.40 752 $12 60 622 84,600 115 20 790 13 80 696 94.600 136 40 855 15 60 741 100,800 168 30 939 17 70 70 $115 00 822 75 129 00 865 77 152 00 532 81 186 00 1020 Fu. nace with asmg and Hood rade 'ices Appro*. Shipping WeiQht *7 00 1049 Square Jacket at Hood Appro*. Shipping Weight 883 916 978 1068 Burner. ung and retiming hearth ring* and sed by a number e used. at top or one pipe nnhed only with RAPACITIES AT CORRECT SIZE HUMIDIFYING : I sw\_ ' cV_ 4 } Furnace Number CLIFTON Steel Pipe Furnace Catalogue Page SI3-15, 17 GALVANIZED ROUND CASING D'am. Shell ft Rating Square Inches Btu Capacity at Registers Furnace Onfy Trade Prices Approx. Shipping Weight Casmg and Hood T rade Prices Appro*. Shipping Weight Furnace w.;n Casing ana Hood T rade Prices Appro* Shipping Weight D-8030-S A C-8034-SA 30' 34' 943 1024 128.200 $225 50 139,300 300 50 1205 1355 $21.50 24 50 Smoke Tees for Clifton Steel Furnace*: 10' (for 8030, 8034) $4.00 Trade Pnce 101 113 $247 00 325 00 1 306 1460 Furnace Number ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page SI 1-12 SQUARE METAL JACKET Diam. Shell ft Ratmg Square 1nches Btu Capacty at Registers Furnace w ith Square Jacket and Flat Hood Trade Prices Approximate Shipping Weigrrt tD-520-SQS ?D-522-SQS D-524-SOS D-527-SQS 20' 596 81,000 $126 00 1015 22' 622 84,600 142 00 1 C52 24' 696 94,600 162 00 1145 27' 741 100,800 197 00 1255 Furnace is equipped with three steel chutes for firing from rear or left or right hand side, fire Dnc* lining and supports. Metal plates and gaskets are provided to seal cnutes not used. When stoker is to be installed m front or below base of furnace, the above mooeis cannot be used a^c hand fired models as shown on page 5 should be ordered less grate assembly and ash oit door. fNOT; These sues equipped with steel chutes on right and left side only. NOTE: Sufficient space is not available on the standard hood for the total rating to be used by a number of tmali pipe take-offs. For sue* a condition 12* pipe take-offs with "Y" connections may be used. NOTE Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models Flat top or one pip* type hoods furnished when ordered, without extra charge. The Arlington "Square" is furnished only win straight ude flat top hood which is a part of the jacket. ttSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS." SEE PAGE 18 FOR AUXILIARY WATER HEATER COILS; PAGE 19 FOR HUMIDIFYING EQUIP MENT. 7 SE-3 Gas Fired AMERiCAN-c^tandard heating equipment Sunbeam Furnaces Sunbeam Floor Furnac- SUNBEAM GAS FIRED FURNACES SHAWNEE -- Steel Heating Element Catalogue Page S18-19, 29 Furnace Number For use w 11h Manufactured, Natura , or Mixed Gas A.G A. Rating Btu 1 nput per Hour Btu Capacity at Registers M Rating Souare Inches For use with L P. G. A G A. Rating Btu Input per Hour Btu Capacity at Registers ft Rating Souare Inches Trade Pnc as w-th Standard E uipment For use with Manufactured, Natural, or Mixed Gas For use with L. P. G. Control Combination No G-1 Or No G-2 Cont r 01 Combi nation No G-3 Approx. Ship ping Weight SG-65 65.000 35.560 268 60,000 33,750 248 SG-80 80.000 *5,000 331 SG-105 105,000 59,060 435 105,000 59,060 435 SG-120 120,000 67,500 496 120.000 67,500 496 bU*l *u 1*0,000 78,750 579 $'09 50 120 00 137 50 14B 50 1 62 50 $138 00 166 00 177 00 270 303 361 407 477 Standard Equipment Includes: Souare Metal Jacket. Manual Shut-off Valve Steel Heat'ng Element. No. 850 BASO Automatic Pilot Switch. Gas Pressure Regu'alor (Except for L. P. G.) Ribbon Burner. Draft Hood _ Control Combination as specified. Control Combination No. G-1 Control Combination No. G-2 Control Combination No. G-3 For use with Manufactured, Natural, or Mixed Gas. For use with Manufactured, Natural, or Mixed Gas. For use with L. P. G. Detroit No. 411-CH Plain Thermostat. Detroit No. V-57&-M Electric Gas Valve and Transformer. MHNo T-81-A Plain Thermostat. MH Solenoid Gas Valve and Transformer: V-835-D. except with SG-140 for Mfd. Gas V-8*-C with SG-140 for Mfd. Gas. MH No. T-11-A Plain Thermostat. MH No. V-155-A Motoriied Gas Valve and Transformer. Special Control for 100% Safety "Shut-off." CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT. OPTIONAL EQUIPMENT Add to Above Trade Pncei No. LA-H9-A Limit Switch (Airstat) for MH Controls (Catalogue Page S261 No. CA-80S Air Limit Cont-ol for DL Controls................................................................ $ 7 43 7 35 "SEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS." SEE PAGE 19 FOR HUMIDIFYING EQUIPMENT. PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions for Ordering Orders must specify M ) Type of Gas df L. P. G , whether Butane or Propane). (2! 8tu Content. (31 Speci He Gravity (A) Control Combination Desired. f5i Elevation at which equ pment w<11 be operated if in excess of 2,000 feet. RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2030 FEET FOR ELEVATIONS ABOVE 2,000 FEET, RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL. =r\ r\ V rir-t 1 Nc 31. C-2: 2:.::: 0n-.25n 3tz: ::::z: 0 We z e z 5 e e - > Cute* a - : c :?r =; s-er Cc~\'o- Cc'-i Control Com b' r For Use * ;n V Mj " rc P : ,, Pilot Burner. Control CorrFor Use w " V le-` C' Nil Fc- Mam a-c P 'ot . PG-5 p ;t Gv 3C Ft Tc-* ; voca'a ' 04137 n Furnaces it -jSfl G. Apprpx Sh'PP'-g Weigni roi on G-3 00 j CO | 270 3C3 361 *C7 477 P.io: Switch. tlen No. G-3 G. am Motor,;ed Gas 'crrner 1007 Safety UNIT. 9 Trade Pr ces 7 43 7 35 3ACt Tl ES AT MPERATUPE N^-"' of 2,000 feet. ABOVE 2,000 'EET ABOVE Sunbeam Floor Furnaces African-Standard heating equipment Gas Fired SUNBEAM GAS FIRED FLOOR FURNACES SAGINAW -- Steel Heating Element Catalogue Page S20-21, 30 0-20 0-35 0-60 0-79 For Use with Mfd., Nat. Or Mixed Gas Btu 1 nput Hour Btu Output per Hour A.G.A. Ratmg For Use with L. P G. Btu Inout per Hour Output per Hour Trade Prices w th Standard Equipment For Use with Butane-Air 525 Btu. Btu Input per Hour Btu Output oer Hour With Con- trol Combmat'On A With Con- trol Comp- i nation B With Control Combinat'On C With W.th Con- Con- trol trol Comb- Combi nation mat'On D| E 20.000 35.COO 50 noO 70,COO 14,000 24.500 35,000 49,000 20,000 14,000 35,000 24,500 150,000 135,000 57,000 39,900 20,000 50,000 14,000 (33 00 41 45 35,000 59 50 72 36 138 CO 46 45 64 60 77 35 $50 60" .... i$56 50 59 05* 64 95 $79 90 83 10 92 65 95 85 A np Wgt. no 135 1 86 2*8 fFor Bjiane Gas Input 38,000, Output 26,600. Welded Steel Heating Elerrent. Outer and inner Casing. Floor Register. Contro' Comp'nat'on as spec.Ted Standard Equipment Includes: Burner, P'pmg lighting Pod. Gas Pressure Regulator Eicept w-th L. P. G Draft Hood. Control Combination A -- Manual Control with Locking Device For Use with Mfd., Nat., or Mixed Gas. Mam and Pilot Gas Cocks. PUo: Burner. Control Combination B -- Manual Control with BASO Automatic Pilot For Use with Mfd., Nat.. Mixed or L. P. G. No. 831-1 BASO Thermostatic Mam and Pilot Valve--i'10C7c ''Shut-off"). Pilot 8urner. Control Combination C -- General Controls Self-Energizing Set For Use with Mixed Gas i800 Btu Minimum Con tent) or Natural Gas only. Control Combination D--General Controls Self-Energizing Set For Use with Mfd., Nat., or Mixed Gas. (For Q-20 and Q-35 ONLY): Mam and Pilot Gas Cocks. T-fiO-1 Thermostat. B-60-6 Automatic Gas Valve. PQ-6 Pilot Generator. 30 Ft Two-wire CaDie. For Q-50 ana Q-70 ONLY.Mam and Pilot Gas Cocks. T-80-1 Thermostat. B-60-i Auiomatic Gas Valve. PG-i P lot Generator. 30 Ft. Two-wire Cable. Control Combination E---Mlnneapolls-Honeywell Y-77-C Low Voltage Set For Use with Mfd., Nat., Mned, or L. P. G No. 831-1 BASO Automatic Main ano Pilot Valve--(1007c "Shut-off"). Pilot Burner. No. T-81-A Plain Thermostat. No V-835-D Solenoid Gas Valve and Transformer. 30 Ft. Two-wire Cable. IMPORTANT NOTE Soecify ONLY Control Combination B or E for Use wiin Liquefied Petroleum Gas or Butane-Air. Deduct (3.35 from Trade Prices shown above for omission of Gas Pressure Regulator ^ when specified for L. P. G. MH No. V-825-0 Gas Valve is replaced by No. V-835-A Gas Valve m Control Combination E when specified for use with L. P. G. pr Butane-Air CONTROL COMBINATION BY LETTER DESIGNATION MUST BE SPECIFIED WITH EACH UNIT Instructions for Ordering Orders must specify it' Type of Gas (If L. P. G , wnethgr Bjtare or Propane1. 2 Btu Content. 31 Specific Gravity. i'4' Control Combination Desired. ,5. E'evat'on at which equipment w.ii be operated if m excess of 2.COO feet RATINGS SHOWN ARE FOR ELEVATIONS UP to 2 OOC FEET for ELEVATIONS ABOVE 2.000 FEET. RATINGS SHALL BE REDUCED AT THE PATE OF 5 PEP CENT FOR EACH 1.000 FEET ABOVE SEA LEVEL. 9 SE-3 Hand Fired AMERICAN-rt^tandard Sunbeam Winter Air HEATING EQUIPMENT Conditioners SUNBEAM WINTER AIR CONDITIONERS HAND FIRED Un.il Number 0-5520 0-5522 0-5524 0-5527 ALLERTON -- Steel Heating Element Catalogue Page S34-37 i1 , Btu Caoac'iy at Refl<sters [ ) 35,100 ! ! io7,3co ; < 120,000 i I 127,900 i 11 Trade Pnces with Standa'd Equipment ) S-.a8 00 2t I 00 250 00 295 00 ! I j Appro*,mate Sr. coi r g We ght 1205 ' 056 t 5 7C l 508 Uni} Number D-30B0 C-3430-B CLIFFDALE -- Steel Heating Element Catalogue Page S38-40 i| Btu Capacity at Registers ] !l Trade Prices Including Smoke Tee and Standard Equipment j j j 162.500 | J<35 00 j j 177,000 i 520 00 j A ccrOAimate Shtob-ns We-ght 22)9 2*32 Squire Metal Jacket. Inner Casing and Rings. Standard Equipment Includes: Blower Cabinet. 8(ower, Belt and Pulleys. Rubber Mounted Motor with overload protection. A.r Filters. NOTE: Biower capmets on Ailerton and ChHdale Units can be attached to e-ther right or Jef; s-de of healing jacNet. SEE PAGE IB FOR AUXILIARY- WATER HEATER COILS, PAGE 19 FOR HUMIDIFYING EQUIP MENT; PAGE 20 FOR TEMPERATURE CONTROL EQUIPMENT. SE-3 to I t t Sunbeam Winter Conditioners SC 0-55:2-:; : O-t::*-G : a D-552:-G a- = C-t<iC-:S : =? Cijtes *3' -s-.at":'' r h ea-th p;ate r : z rrj CPC'S i^d Z SEE PAGE cc = W^Cr\AV; Cl e U- : U v*. f'e: OoC'-S c*3<=:-s= S:w3-e Me'a . 3 ` I nr' Ca> i- : ~ NOTE 5 hea*'rg ;a:ee- : SEC ?:rr s VENT 04139 inter Air Jitioners ( I-a:e /*\ I ora. G EQUIP- Sunbeam Winter Air ^MiRiCAN-c^taitdard Conditioners HEATING EQUIPMENT Oil Fired Stoker Fired Unit Number 0-5522-G or R D-552A-G or R 0-5527-G or R SUNBEAM WINTER AIR CONDITIONERS OIL FIRED ALLERTON -- Steel Heating Element Catalogue Page $34-36 For use with Gun or Rotary Type Burners Btu Capacity at Registers 107,300 120,000 127.900 Trade Prices with Standard Eauipment S2H 00 250 00 298 00 Approximate Shipping Weight 1027 1139 1250 CLIFFDALE -- Steel Heating Element Catalogue Page S38. 40 For use with Gun or Rotary Type Burners Unit Number Btu Capacity at Registers Trade Prices and Standard Equipment Approximate Snipping Weight D-3030-G or R C-3480-GB or RB 162.500 177,000 405 t>0 520 00 1775 1919 . IMPORTANT: When ordering specify whether for use with Gun iG 1 or Rotary <R: Type Burner. For Gun Type Burner, Units will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, Units will be equipped with cast iron hearth rings and brackets, hearth plate, fire bo* liners and mineral wool insulation. Grates and Fire Brick are not furnished. Speca fire doors and burner doors are supplied. SEE PAGE 56 FOR ARCOFLAME OIL BURNERS ANO CONTROLS, PAGE 17 FOR CORRECT SIZE arcoflame oil burners to be used with these units. ______ _____ STOKER FIRED ALLERTON -- Steel Heating Element Catalogue Page S34-36 Unit Number D-5522-S A D-5524-SA D-5527-SA Btu Capacity at Registers 107,300 120,000 127.900 Trade Prices with Standard Equipment (211 00 250 00 298 00 Approximate Shipping Weight 1 164 1284 1407 CLIFFDALE -- Steel Heating Element Catalogue Page S-38, 40 Unit Number Btu Capacity at Registers j Trade Prices j | and Standard Equipment ] Approximate Shipping Weight D-3080-S C-348O-S0 162.500 177.000 | (435 00 1 520 00 1 | 2033 2215 Unit IS eouipped With three steel Chutes for firing from rear or left or rignt hand Side, fire crick lining and supports Metal plates and gaskets are provided to seal chutes not used. When stoker is to be installed m front or below base of unit, the above models cannot be used and hand ffed units as shown on page 10 should be ordered less grate assembly, ashpit door, and hana firing accessor-es NOTE' These units equipped with steel chutes on right and left side only. Square Metal Jacket. Inner Casing and Rings. OIL FIRED OR STOKER FIRED Standard Equipment Includes: Blower Cabinet. Blower, Belt, and Pulleys Rubber mounted motor with overload protection. A*r Fitters. NOTE Blower cabinets on Ane'ton and Cliffda'e Models can be attached to eitner r.ght or left S'de of heat.ng jacket SEE PAGE 58 FOR AUXILIARY WATER HEATER COILS, PAGE 19 FOR HUMIDIFYING EQUIPWENT $-3 Oil Fired AwERICAN-e^tandard Sunbeam Winter Air heati.VG equipment Conditioners SUNBEAM WINTER AIR CONDITIONERS OIL FIRED SARATOGA and WESTMORELAND ARCOFLAME OIL HEATING UNITS Steel Heating Element Catalogue Page $41-46 Unit Njmoer 1 j E-H20-F ! B-11 2*-BA I B -1 " 2 7 - B A j B-11 34-BC-18- W 1 B-113--BC-l8->, ! B-H3<-BC-2l-* 1 Burner Model Number C-iS C-iS C-iS c-:s X L-1 S L-iS ! No22ie S>ae Gallons per Hour 1 25** 1 SO 2 00 2 50 j 3 00 i 3 SO Btu Capacity a: Registers 95 000 tso.ooo 200.000 20,GOG 285,000 330,000 Trade Prices witn Standard Eduioment $338 20 452 70 515 20 560 20 587 45 62 20 Aoorcuima'e S h; 5Qc ng Weight 1 1 30 1 552 1833 2'74 2255 2401 Supplied with Soeciai Turpufator Attachment. Set Dunn 80-90 ids pressure. The Saratoga, No. -1 ' 20-F, has Heat mg Element and Blower enclosed in single Jacket Tne W estmcu e- land Units have Heating Element enclosed in a seoarate Jacket and Blower enclosed m a caomet wnich can be attached to either ngnt or left side of Heating Jacket. Standard Equipment Includes: Squa'e Metal Jacket. Inner Lining. Blower. Belt, and Pulleys. Rubber Mounted Motor with Overload Protection. Air Filters. Draft Stabihier. Heat Lib-Q-Raior Molded Refractory Combustion Chamoer. ARCOFLAME 01 Bu'ner and Noule, CA-701 Stack Control. No 20 Control Set (<ii-CH Thermostat, CA-8f5 Rlower and Limit Control). NOTE. Delroif *tl-CDN Day-Night Heat Compensated Thermostat and 772 Tem-Clock Combination may be substituted fo' atl-CH Thermostat m Control Set No 20, the suffix "A" after Control Set Number wi|, designate this substitution. If desired, add $17.63 to the above Trade Prices. SARATOGA and WESTMORELAND -- Steel Heating Element Catalogue Page S4M5 Without Oil Burner or Controls Unit Number E-112ChF 8-j :?a-8A B-i 127-BA B-1 ', 3*-BC-18- '/i B-1 i 3A-BC-18- M B-11 34- BC-21 - *\ Recommended Noaale Sue Gallons per Hour 1 25 1 50 2 00 2 50 3 00 3 50 Biu Capacity at Registers 95,000 1 50,000 200,000 240,000 285,000 330,000 Trade Prices with Standard Equipment $195 50 307 00 368 00 4 \ 3 00 425 25 480 00 Approx, mat e S hi ppi rg VN e1 ght 675 1263 1521 1 B61 1579 2014 Standard Equipment Includes: Square Metal Jacket. Imer Lining. B.owa\ Bolt, and Pulleys Rubber Mounted Motor with Overload Protection, Air Filters. Mineral Wool Insulation Refractory Brick. SEE PAGE 15 POP aCOFlaM BURNERS AND CONTROLS RAGE I? FOP H A T liB-O-PATOR COMBUSTION CHAMBERS. PAGE IS FOR HUMIDIFYING EQUIPMENT. SE-3 s Sunbeam Winter Ai Conditioners SUN! SEN: Steel Heatin'. 1 ( Per ,,S9 w - ] Ml,:. Nqmjer | AC A j Rating 1 Stu ! n;_I ; per hcj- ?,! -70 $ 1-85 SL-105 si-i:s c -`SO ' ; 7c oc: 85 OCC 105.030 !" ' 5: o: : WYAM Steel Heo1 i * set ^ *e d n , Un-t N U m. o 6 r 1 AG A i Rat -g ' Biu Tb.: : 30r Ho.' SUA-55* ; S JA-7C* , S'JA-85* * SU- iv5 c.t 73 3'3'C 85,3-3 3 iCc.OGu A~or L P. G., spec fr Cc Meta! Jacket. Steel Heating E!eme-' Gas Pressure Regulator l. P. GJ Control Combination Por Use w!" Wa*ya:t.'or M . r s c Gas Detroit No. * 11 -C m ^ Thermostat Detroit No V-570 ': Valve and Trar5fcr--.e' Detroit No. GA-315 5 : Limit Sw;tch. #Ccn;rof Ccmoma*. s"1 -~ ~CCNT?0^ c"5~m SuA-55. S'JA.tc a- : : be 'ocated cn !>'' s in.at will ce SuCS'.tu.'eo j SU-1C5 Wnr;;i;t U n SEE PAGE ' 5 FO3 C PERATURE COn:3a O'oe's ~. v RATING? S~ ' - PATiNGS 3hi.. BE -LEVEL. 04141 ter Air lioners i 1 30 :Sb2 633 21 7* 22 65 :<c Westmorewhicn can cfTiomation el Nuuimi Q cumate ig Weight 876 353 521 861 'S'S ) Sunbeam Winter Air Conditioners AwRiCAN-i$tadard HEATING EQUIPMENT Gas Fired SUNBEAM WINTER AIR CONDITIONERS SENECA -- GAS FIRED -- Catalogue Pago S47-48, 60 Steel Heating Element -- With Blower at Right of Heating Compartment Unit Number SL-70 SL-85 St-105 Sl-125 SL-iSO Trade Prices with Sid. Equipment For use with Manu factured. Natural, or Mixed Gae A.G.A. Rating Btu Inout per Hour Btu Capacity at Registers For use w th L. P. G. A.G A. Rating Btu Input per Hour Btu Capacity at Registers For use with Manu factured, Natural, or Mixed Gas Control Combination No. A-1 Or No. A-2 For use with L. P. G. Control Combi nation No. A-3 Approx. ping Weight 70,000 85,000 105,000 125,000 1 50.000 47,600 57.800 71,400 05.000 102,000 61,000 105,000 125,000 41,460 71.400 85.000 5198 00 215 00 228 00 250 00 275 00 (226 50 256 50 278 50 WYANDOTTE -- GAS FIRED -- Catalogue Page S49-50. 60 Steel Heating Element --With Blower Under Heating Compartment 396 414 463 505 590 1 -a 1 zl For use with Manu factured, Natural, or Mixed Gas A.G.A. Rating Btu Input per Hour Btu Capacity at Bonnet For use with L. P. G. A.G.A. Rating Btu Input Per Hour Btu Capacity at Bonnet Trade Prices with Sf For use with Manu factured, Natural, or Mned Gas Control Combination No. A-1 Or No. A-2 touipmeni For use with L. P. G. Control Combi nation No A-3 Approx. Ship ping Weight SUA-55* SUA-70*SUA-05* SU-105 55,000 70,000 85,000 105,000 44,000 56.000 68.000 84,000 55,000 61,000 *05,000 44,000 48,800 84,000 *177 00 193 00 210 00 223 00 A *221 50 251 SO 295 393 423 500 A.For L. P. G-. specify Control Combination A-4 # and add *15.00 to Trade Price of SUA-55 with A-l Controls. Standard Equipment Includes: Metal Jacket. Manual Shut-off Valve. Steel Heatmg Element. Blower-Motor Unt. Gas Pressure Regulator (Except for Air Filters. L. P. G.) Control Combination as specified. No. 850 BASO Automatic Pilot Switch, Ribbon Burner. Draft Hood. Control Combination No. A-1 ( Control Combination No. A-2 | Control Combination No. A-3 For Use w-th Manufactured, Natural, For Use with Manufactured, Natural, or Mixed Gas or Mixed Gas* For Use with L. P. G. Detroit No. 411-CH Piam Thermostat. Detroit No. V-570 Electric Valve and Transformer. Detroit No. CA-815 Blower Limit Switch. Gae and MH No T-81-A Plain Thermostat. MH So'enoid Gas Valve and Transformer? V-835-A, except with SL-150 for Mid. Gas. V-84-A with SL-150 for Mfd. Gas. MH No. LA-101-A Blower and Limit Switch. MH No. T-ll-A Plain Thermostat. MH No. V-155-A Motorized Gas Valve and Transformer. MH No. LA-101-A Blower *n<j Limit Switch. Special Control for 100% Safety "Shut-off " Control Combination A-4 aame as A*t, except with 100% Safety "Shut-off" and valve equipped for L. P. G. CONTROL" COMBI NATION"by NUMBEfT MUST BE SPECl FI ED ~wTth ~ACH ^JnItT *SUA-55, SUA-70 and SUA-85 WYANDOTTE Units are regularly furnished with filter frame which may be located on either s*de. If desired, and so specified on order, special Air Filter 8ase for bottom return a<r m:et will be substituted at no additional charge. SU-J05 Wyandotte Unit is eouipped with 2 filter frames, one on each side. SEE PAGE f9 FOR COMBINATION "S" FLOAT HUMIDIFIER, PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions for Ordering Orders must specify H i Type of Gas (If L. P. G., whether Butane or Propane (2' Btu Content. (3i Specific Gravity. (4 i Control Combfnation desired. (5i Elevation at which equipment will be operated if m excess of 2.000 leet RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2.000 FT. FOR ELEVATIONS ABOVE 2,000 FT . RATINGS SHALL BE REDUCEO AT THE RATE OF 5 PER CENT FOR EACH 1.000 FT. ABOVE SEA LEVEL. 13 SE-3 Gas Fired AMSRICAJtf-^tatldard Sunbeam Winter Air heating equipment Conditioners Unit Number SUNBEAM WINTER AIR CONDITIONERS MOHAWK --GAS FIRED Catalogue Page S51-54. 60 Cast Iron Heating Element For Use wth Manufactured, Natural, Mixed or L. P. G. A.G.A. Rating Btu nout per Hour Btu Capacity at Registers T ade Prices with Standard Eduo ment For Use with Manufactured, Natural, For Use with or Mixed Gas L. P. G. DL Control Comb. No. A-1 DL Control Comb. No. A-6 MH Control Comb. No. A-7 MH Control Comb. No. A-8 MH Control Comb. No. A-9 Approx. Shipping Weight K-60 KSO K-100 60,000 80,000 100,000 40,800 54,400 68,000 1212 00 235 00 260 00 4229 00 252 00 276 50 $212 OO 235 00 260 00 *229 00 252 00 276 50 *246 00 270.50 292 00 K-120 K-1 SO K-180 120,000 1 SO,COO 180,000 81,600 )02,000 122,400 290 00 330 00 375 00 306 50 346 50 391 50 290 00 330 00 375 00* 306 50 346 50 391 50 322 00 363 00 408 00 K-200 K-2*0 K* 300 200,000 240,000 300,000 36,000 '63.200 204,000 405 00 457 00 542 00 422 00 4 74 00 559 00 405 00* 422 00 4 74 00 559 00 438 50 4 90 50 573 00 For Use wit* Muse Gas (800 Btu Minimum Content) or Natural Gas Only, Standard Equipment Includes: Meta' Jacket. Manual Shut-off Valve, Cast iron Heatmg Sections. Air filters. Gas Pressure Peculator (Except for L. P, G.) Ribbon Burners. 8iower-- Motor Unit. Draft Hood. No. 322 8A$0 Automatic Pilot Valve--for Second and Successive Sections with DL Control Combination No A-6, for Each Section with DL Control Combination No. A-1, and MH Control Combina tions No A-7 and No. A-8. Nc. 850 8ASO Automatic Pilot Switch for Each Section with MH Control Combination No. A-9. Control Combination as specified. 527 78S 84 7 905 1239 12*6 1557 1605 1883 Control Combination No. A-1 Control Combination No. A-6 For Use with Manufactured, Natural, or Mixed Gas For Use with Manufactured, Natural, or Mixed Gas Detroit No. 411-CH Plain Thermostat. Detroit No. V-570 Electric Valve and Transformer. Detroit No. CA-815 Blower Limit Switch. Gas and Oetroit No. 411-CH Plain Thermostat. Detroit No. 566-VPThermotor Gas Va've. Limit Control. Trans former and Vapor Tension Ther mostats Pilot for First Section. Detroit No. CA-810 Blower Switch. Control Combination No. A-7 For Use with Manufactured, Natural, or Mixed Gae MH No. T-81-A Plain Thermostat. MH No. V-835-A Solenoid Gas Valve and Transformer (Except No. K-240 ana No. K-300'. MH No LA-101-A Blower a"d Limit Switch. Control Combination No. A-8 Control Combination No. A-9 For Use with Mfd., Nat., or Mixed Gas. MH No. T-il-A Plain Thermostat. MH No. V-15S-A Motorized Gas Valve and T nnsformer. MH No. LA-101-A Blower and Limit Switch. For Use with L. P. G. MH No. T-il-A Plam Thermostat. MH No. V-155-A Motorized Gas Valve and Transformer. MH No. LA-101-A Blower and Limit Switch. Special Control for lOQE^ Safety "Shut-off." CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT. SEE PAGE 19 FOR HUMIDIFYING EQUIPMENT; PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions for Ordering Orders must specify (it Type of Gas (If L. P. G., whether Butane or Propane). i2> Btu Content. ' 31 Specific Gravity. (4. Control Combination desired. '51 E'evation at which equipment w.il be operated if m excess of 2,000 feet. RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2.000 FEET. FOR ELEVATIONS ABOVE 2.C00 FEET RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH t.000 FEET ABOVE SEA LEVEL. SE-3 M C_ Sunbea Conditii '). OeC M_- 3 Ci;- )C Fc' Use MH No MH MH N: F 3 r- Us De'-o : Os1/:- Tra-- 'ea*. ) a: r.o i SEE CON' ) 04143 ir s *9 - '1 -o t? 7 is JOt ntj o sc JCO v'E Sunbeam Winter Air A.M rican- <tcLttdavd Conditioners HEATING EQUIPMENT Gas Fired Unit Number SUNBEAM WINTER AIR CONDITIONERS CHIPPEWA --GAS FIRED -- FACTORY ASSEMBLED Catalogue Page S55, 60 Cast Iron Heating Element With Blower Under Heating Compartment For use w<th Mfd.. Nat., Mned, L. P. G. or Butane-Air (525 Btu). A G.A. Rating Btu Input per Hour Btu Capacity at Bonnet Trade Prices with Standard Equipment For Use with Mfd., Nat , or Mixed Gas Control Comp.nation No. A-7 or A-16 No A-16E For Use with L P. G or Butane-Air '525 Blui. Corn oi Combination No A-17 Approx, Shipping Weight KUA-60 60,000 48,000 $229 00 $253,50 $247 35 500 #Deduct $3.35 from Trade Pnc for omission of Gas Fressure Regulator when spec.fled for use with L. P. G. Standard Equipment Includes: Metal Jacket. Manual Shut-oH Valve. Cast iron Heating Element. Blower-Motor Una. Gas Pressure Regulator--(Except for L. P. G.j. Air Filters. Control Combination as specified. Ribbon Burner. Draft Hood. BASO Automate Pilot Valve with Control Combinations No. A-7, A-16 and A-16E. BASO Automatic Pilot Switch with Control Combination No. A-17. Control Combination No. A-7 Control Combination No. A-16 For Use with Manufactured, Natural, or Mixed Gas. For Use with Manufactured, Natural, or Miaed Gas. MH No. T-81-A Plain Thermostat. MH No. V-835-A Solenoid Gas Valve and Trans former. MH No. LA-1QI-A Blower and Limit Switch. Detroit No. 411-CH Plain Thermostat. Detroit No. V-574-F Electric Gas Valve and Trans former. Detroit No. CA-810 Blower Switch. Gas Valve has mechanical lima and manual opening feature. Control Combination No. A-16E Control Combination No. A-17 For Use with Manufactured, Natural, or Mixed Gas. For Use with L. P. G. or Butane-Air (525 Btu). Detroit No. 411-CH Plam Thermostat. Detroit No. V-574-F Electric Gas Valve and Transformer. Detroit No. CA-810 Blower Switch. Electric Pilot Igniter. Gas Valve has mechanical limit and manual opening feature. Detroit No. 411-CH Plain Thermostat. Oetroit Electric Gas Valve and Transformer- No. V-571 for L. P. G. No. V-570 for Butane-Air (525 Btu). Detroit No. CA-815 Blower and Lima Switch. Special Control for 10O9 Safety "Shut-off." CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT. The Chippewa Unit is regularly furnished with filter frame which may be located on either side, ff desired, and so specified on order, special Air Filter Base for bottom return air inlet will be substituted at no addaional charge. SEE PAGE 19 FOR HUMIDIFYING EQUIPMENT; PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT. Instructions for Ordering Orders must specify (1) Type of Gas (If L. P. G., whether Butane or Propane). (2) Btu Content. (3) Specific Gravity. (4) Control Combination desired. (5) Elevation at which equipment will be operated if m excess of 2,000 feel. RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2,000 FEET, FOR ELEVATIONS A80VE 2 000 FEET, RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL. 15 SE-3 04144 Arcoflame Burners AFRICAN-Standard HEATING EQUIPMENT Arcoflame Burners ARCOFLAME OIL BURNERS COMPLETE with STANDARD ARCOFLAME BURNER CONTROL SET AND NOZZLE* Catalogue Page S46 (A Standard Arcoflame Burner Control Set Must Be Purchased With Each Arcoflame Burner) Modef Number C-1S C-2S With Control Set Number 19 For Gravity Furnaces 20 For Winter A.f Conditioner Contents of Arcoflame Standard Control Sets No. 411-CH Thermostat. No. CA-805 Air Limit Control No 411-CH Thermosiai. No. CA-815 Combination Blower amj Limit Control, T'ade Prices $124.50 130 70 C-3S For Use on 115 Volt, 60-Cycle Current MAXIMUM CAPACITY 3 00 GALLONS OIL PER HOUR Approximate Sh pping Weight 140 pounds L-IS L-3S 19 For Gravity Furnaces 20 For Winter Air Conditioners No 411-CH Thermostat. No CA-805 Air Limit Contro' No. 411-CH Thermostat. No CA-815 Combination Slower amt Lnmt Control For Use on 115 Volt, &0*Cycle Current MAXIMUM CAPACITY 7.00 GALLONS OIL PER HOUR Approximate Shipping Weight 165 pounds :37.50 M3.70 IMPORTANT: When subst'tution of 41 1 - CON ana 772 combination <s made for 411-CH such eontrc' sets wdi be designated by suffix "A" after control set number If desired, add 5 5 7 53 to above Trade P*ices. When ordering Arcoflame Oil Burner be sure to specify Nor*!e s<ze desired, Thermostat cable not furnished. IMPORTANT NOTfCE Trade Prices lor Arcoflame Burners and Standard Burner Control Sets as shown above include, m aodwon to the Norzie and Controls as listed, a No. CA-701 Arcoflame Stack Control. Arcoflame Burners will be solo only when ordered m combination with one of the Arcoflame Stardard Burner Control Sets, as shown above. Additional Arcoflame Controls may be purchased separately at Trace Prices shown below. 'When Arcofltme Burner isordirert with Noriie Sires of 1.25 and 1.35 Gallons per Hour, Soecia! Turcviator Attachment i$ furnished at no additional charge. Arcoflame CM Burners are approved by the National Board of Fire Underwriters and comply with Comms'c^ai Standards CS-75. IMPORTANT NOTE Motors and Controls regularly furnished are for 115 Volt, 60-Cycfs A. C, CONTROLS FOR ARCOFLAME OIL BURNERS Catalogue Page S61-62 Trade Prices---When Ordered Separately Stock Number Description Standard Controls -- 115 Volt, 60 Cycle ) Trade | Prices CA-701 CA-702 *1 l-CH 411-CDN 1411 -TO 772 CA-805 CA-815 CA-810 CA-295 Stack Control (Intermittent Ignition!. .... I Stack Confoi iConstani (gmlionj . . i Detroit Heat Compensated Thermostat Low Voltage Scale 40'-90'F.) | Detroit Day-Night Heat Compensated Thermostat 'Scale 40C-90CF.) , Detroit Night Turn-down Assembly .... Tem-Ciock with T'ansformer i Detrct Au Limit Control ( High VaCage> fSca'e I90--3005F.' iStoo 250'F.i 1 JDetroit Combination Blower and Limit Control (High Vonagei iScaie Blower 7SC*2255, Limit 1 OO'-SOO1*. Stop 20CcF.l } Detroit Furnace Blower Control (High Voltage! (Scale 75-275:iF.) i Detrct Relay Transformer - $27 oo 2b Cb 6 56 9 *5 1 35 16 73 7 35 1* a 8 4C 8 78 411 -CON The rmostat is used only in combination with 772 Tem-Clock JOrder 411 -TO and 772 Tem-Ciock to convert existing 41 1-Ch Plain Thermostat to Automatic Day-N.gnt operation SE-3 16 04145 t Combustion Chambers AwiRiCAN-c^taitdard HEATING EQUIPMENT Arcoflame Oil Burners oo I O' _ \. \Jr ARCOFLAME CONVERSION OIL BURNERS FOR USE WITH SUNBEAM GRAVITY FURNACES KENWOOD A-1018-CD or BO A-1040-CD or BO A-1044-CO or BO A-1048-CO or BO A-1052-CO or BO C-2S C-3S C-3S C-3S C-3S ARLINGTON ANO ARLINGTON ''SQUARE" D-520-G or O-520-SQG D-522-G or 0-522-SQG 0-524-G or D-524-SOG 0-527-G or D-527-SQG C-2S C-2S C-2S C-2S CLIFTON D-8030-G C-8034-G C-2S L-3S FOR USE WITH SUNBEAM WINTER AIR CONDITIONERS CLIFFOALE ALLERTON 0-3C80-G C-3483-GB C-2S L-3S 0-5520 0-5522-G D-5524-G D-5527-G C-2S C-2S C-2S C-2S Combustion Chambers not furnished. See Arcoflame Oil Burner Installation ana Service Guide for sug gested sue and shape. NOZZLES AND STRAINERS FOR CONVERSION OIL BURNERS For Modal C -- Gals, per Hr. Spray Angle For Model L Gals, per Hr. Spray Angle FOR SARATOGA ANO WESTMORELANO UNITS Untt Number Ga's per Hr. Spray Angle 1.25 1.35 1 50 1 65 1 75 2 00 2 25 2 50 2 75 3 00 80 80* 60* 80 60 60 60s 60 60 60 3 00 3 50 4 00 4 50 5 00 5 50 6 00 6 50 7 00 60s E-1I20-F 60 B-1124-BA 60 B-1127-8A 60 B-11 34-BC-18- H 60 8-1134-8C-18- ** 60 B-1134-BC-21 - * 60 | 60 60 1 25* 1 50 2 00 2 50 3 CO 3 50 80 60 80 45 60 60 Set Pump at 60-90 lbs. pressure if 1 25 Nozzle is used. When these Nozzles are used in Model "C" Arcoflame Burners, the Special Turbuiator Attachment should be used. Special Turbulator Attachment furnished at no additional charge when these nozxiee are supplied as part of one of the Standard Arcoflame Burner Control Sets shown on page 16. HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS FOR SARATOGA and WESTMORELAND UNITS Trade Prices -- When Ordered Separately Slock Number 0S 1s 2S 3S Sunbeam Unit Number Max. Gals, per Hour E-1120-F 8-1124-BA 8-1127-BA B-11 34-BC-18- H B-11 34-BC-18- * B-11 34- BC-21 - 7 1 50 1 75 2 25 3 75 Trade Prices SI 2 00 15 00 16 50 18 50 SE.-3 04146 Water Heater Coils A MFmrAN-^taittfard Gas Conversion Burners heating EQUIPMENT Blower-Filter Units AMERICAN GAS CONVERTOR FOR WARM AIR GRAVITY FURNACES OR WINTER AIR CONDITIONERS Catalogue Page S56 Convenor Number A.G.A. Maximum Input Rating 8tu per Hour Warm Air Output at Bonnet Btu per Hour Trade Prices with Regular Equipment Approximate Shipping Weight 13-A-F 1 5-A-F 19-A-F 23-A-F 150,000 180,000 240,000 360,000 115,000 135,000 180,000 270,000 *100 00 104 75 110 55 126 30 158 180 212 277 Regular Equipment includes complete burner assembly with refractory daffies and front panel assembly, No. 566 Thermotor throttling valve with thermo-pilot and uoper limit control, gas pressure governor and DL No. 411-CH piam room thermostat. NOTE tf Thermostat is not desired, deduct *8.55 from above Trade Prices. For Winter Ai' Conditioners. For Gravity Furnaces, reduce outputs 6%. RATINGS SHOWN ARE FOR SEA LEVEL. RATINGS SHOULO BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL. SUNBEAM BLOWER-FILTER UNITS Catalogue Page S22-27 Unit Numoer Diameter of Wheel Motor Horsepower Trade Prices With Cabinet Less Cabinet and Filters and Filters Approx. Sh.ppmg Weight W<th Cabinet Less Cabinet ano Filters and Filters D-1- 9 D-1-104 0-1-12 D-1-15 1-18-F8 1-21-F B 9* iov 12' 1 5' 18' 21' * 64 00 * 48 50 ii 72 00 54 50 H 86 00 63 50 H 124 00 98.00 H 168.00 139 00 255 00 188 50 1*2 146 181 241 478 633 69 73 9* 121 287 392 Standard Equipment includes pulleys, belt and resilient mounted blower and motor. MH No LA-<I?-A or Detroit Lubricator CA-810 blower awitch-smgie pole tan be furnished at additional Trade Price of $8 40. AIR FILTERS FOR REPLACEMENT Catalogue Page S57 Standard Filter Sizes 20' 25' 20' 20' 16' 25' 16' 20' 15' 20' 10' 20' 1' Thick 80 80 80 80 .70 2* Thick *1 33 1 16 1 16 1 16 1 16 97 NOTE: Filters as shown at left are packaged >n cartons cf tweive (12) of AUXILIARY WATER HEATER COILS Catalogue Page S28, 57 No. of Coif For Gravity Furnaces and Winter Air Conditioners For Use m Coa! Burning Units Only Approximate Shipping Wt. Trade Prices No. 1 x 22' Straight No. 1 x 24' Straight No. 1 x 26' Straight Nc. 1 Forme<3 No. 2 Formed No. 3 Formed tNo. A-1018-CD.-8D ........................................ tNo. A-1040-CO.-BO, A-1044-CO.-BO tNo. A-1048-CD.-BD. No. A-1052-CD.-BD; No. C-8034. No. C-3480-B.. . No. D or BD-522; No. D or BD-524. No. D-S522, No. 0-5524 tNo. D or BD-527. No. D-8030; No. D-3000. No. D-5527 tNo. D or BD-520: No. D-5520 . 6 4 IbS. 7 Ifcj. 7\i fbs. 7 i- IbS. 7 lbs. 6 4 ids. *1 30 1 40 t 40 3 50 3 80 3 45 In ordering, be sure to specify the coif number and the furnace or conditioner witn which it is to be used. For example, No. 1 * 25' Straight Coil, for No. A-1048-CD Furnace, or No. C-3460-B Winter Air Conditioner. The same coils are used with both pipe and pipeless furnaces. SE-3 lers nits ply, OL ") OF O Sunbeam AMRICAN-e>3>tadard HEATING EQUIPMENT Humidifying Equipment Hurmflifier I NumberI HUMIDIFYING EQUIPMENT j Description| Trade Prices FOR GRAVITY FURNACES: WA Catalogue Page S28 ! Automatic Drip Humidifier: j Se'f-contained Heat Actuated Feed Valve Assembly, Metal Pan, Shut*oH Valve. Water ime and Couplings. ' Water Pan for ARLINGTON "SQUARE" ' Water Pan win Cast Iron Frame that attaches to Jacket S 9.25 $ 3 50 FOR WINTER AIR CONDITIONERS: H.4' Catalogue Page S58 S-4QQ Catalogue Page S58 Automatic Spray Humidifier: (For use with ail Winter Air Conditioners anceot Seneca and Wyandotte Units) No. H-t* Fnez Hunttdisiai. No. V-B37-A Solenoid Water Valve including Transformer. 2 No. 390 Water Strainer*. ( No. 26 Water Pressure Reducing Valve. j No 50 Assembly including' Tubing and Fittings, Shut-Off Valve, * I Spray Nozzles with individual Shut-Off Valves. Spray Pan with capacity Adjusting Plate. Nozzle Cleaning Rod, 3 Rubber Caps for 1 Spray Nozz'es not m use. Float Humidifier: Evaporating Plates. Evaporating Pan. Water Reservoir with Float and Valve. Fienbie Tube and Pipe Clamp Valve. S-401 : For SUA-55, K-SO, KUA-60 S-402: For D-552C, 0-5522, D-5524; E-1120-F, SL-70 SL-B5. SL-105. SL-I25. SL-150, SUA-70. SUA-85 SU-I05.-K-80.I K-100, K-120. K-1 50. I S-403 : Far D-5527, B-1I24-BA, K-180, K-200, K-240. I S-404: For D-3080. B-H27-BA; K-300. S-405: For C-3480-8; B-1134-80-18- H.-18-(<.-21-51. I____________Eitra Evaporating Plates, Trade Price Each S 17 *<5 00 tu 65 11 65 12 75 t3 75 15 00 Water Pan tor ALLERTON, CLIFFDALE. SARATOGA I and WESTMORELAND | Water Pan with Cast Iron Frame (hat attaches to Jacket- ! J 3 50 fee *S E-3 04148 Temperature Control Equipment AwERICAN-c^tandapd heating equipment Sunbeam Combination | Description [ Trade Prices MX Catalogue Page $29 A-1 K Catalogue Page S2 FOR ALL HAND FIRED GRAVITY FURNACES: Mechanically Controlled MH Metaphram Oraft Control. A self-contained mechanic*' draft and check regulating instrument Thermostatically Controlled MH No. T-81-A Plain Thermostat. MH No. LA-U9-A Limit Switch (AirstaO. MH No M-87-A Damper Motor with Transformer. No 933 Accessories (Chain. S-Hooks and Pulleys'. 4 a *o 433 '5 FOR ALL HAND FIRED WINTER AIR CONDITIONERS: Mechanically Controlled Mk MH Metaphram Draft Control. Catalogue PageS59 A seif-contamed mechanical drift and check regufatinQ instrument Catalogue Page S59 No CA-8'0 DL Blower Switch. No LA-i2-A MH Slower Switch (Furnacestat). When Room Thermostat Draft Controls are net used, a blower switch s necessary for staMmg and s to DO mg blower when bonnet temperature rises or fails. When controls as listed in Combination B-lX below are used, blower sw.ich is included m control equipment. e-i* Catalogue Page S59 Thermostatically Controlled MH No. T-81 -A P'am Thermostat. MH No LA-tOt-A Blower and Limit Switch (Furnacestatl. MH No M-87-A Damper Motor with Transformer. No 933 Accessories iChain, S-Hooks and Pulleys'. e-5i Same as above exceot with substitution of MH No. T-847-A Chronotherm lor No T-81-A Plain Thermostat. OPTIONAL THERMOSTATS OPTIONAL THERMOSTAT --Description Extra* T rade Prices For Use only with Unit Control Combi nation No 4 8 *0 J 8 10 8 10 4-0 20 4S7 83 Replaces 411-CDN Day-Nighi Heat Compensated Thermostat AND 772 Tem-Ciock 4'7 63 SHAWNEE SENECA WYANDOTTE MOHAWK CHIPPEWA G-l A-1 A-t or A-4 A-1 or A-6 A-16, A-16E. A-1 7 T-109-A Oa-Nite Thermostat (Manually Set) 1 | | 4 9 08 SHAWNEE IsENECA and \ (WYANDOTTE) G-3 A-3 T-M7-A Night and Day Electric Clock Thermostat (Chronotherm) Si 7 63 jMOHAWK A-8 or A-9 T-801-A Time-O-Stat T-847-A Night and Day Electric Clock Thermostat (Chronotherm) $ 5 93 417 63 1SAGINAW ; SHAWNEE :SENECA and \ (WYANDOTTE) . MOHAWK and, , CHIPPEWA j E G-2 A-2 A-7 These Extras to be added to Trade Prices of Units Do not apply if ordered separately. 411-CH Plain Thermostat T-1 1-A Plam Thermostat T-8I-A Plam Thermostat AUTOMATIC NIGHT TURN DOWN ASSEMBLY For Use only wth Trade No. Description Price Unit Control Comb1* nation No 411-TD Night Tgrn Oown assembly AND 772 Tem-Clock Used to convert existing 411-CH P'a,n Thermostat to automatic Day-Night operation 4<8 08 SHAWNEE SENECA W YANOOTTE MOHAWK CHIPPEWA SE-3 20 G-l A-t A-1 or A-4 A-1 or A-6 A1 6. A-I6E. A-1 7