SUNBEAM
GRAVITY FURNACES WINTER AIR CONDITIONERS
Price Book SE-3
DECEMBER 6, 1948
VOTICE The Trade Prices shoicri herein do not include
freight or cartage
Page
GENERAL TERMS................................................
2
FURNACE SELECTION INFORMATION.........
3
SUNBEAM GRAVITY FURNACES................... . .. 4-8
SUNBEAM FLOOR FURNACES........................
9
SUNBEAM WINTER AIR CONDITIONERS. .. ...10-15
ARCOFLAME OIL BURNERS............................. . .16-17
GAS CONVERSION BURNERS......................... . . 18
SUNBEAM BLOWER-FILTER UNITS...............
18
AIR FILTERS.........................................................
18
AUXILIARY WATER HEATER COILS............
18
HUMIDIFYING EQUIPMENT.............................
19
TEMPERATURE CONTROL EQUIPMENT......
20
i
American n <^tadai*d Radiator & ^aiuta*#
CORPORATION Pittsburgh 30, Pa.
04130
General Terms
AMERiCA\-c$*tat?dard HEATING EQUIPMENT
General Terms
1 (lustrations and descriptions of Plate Numbers listed m the price book will be found m the Warm Air Heating Equipment Section of the ''AMERICAN-STANDARD" GENERAL CATALOGUE. Items illustrated m the GENERAL CATALOGUE and not included m this price book are discontinued. Items added since the issuance of the last Catalogue Revision are described for identification.
PRICES
All prices herein quoted supersede all prior quotations and are subject to change with out notice.
No obligation is assumed by this Corporation to sell to any one holding this book any of the items listed herein at the prices stated.
A minimum invoice charge of forty-five cents (.45) will apply on any item including repair parts.
TAXES
To the prices and terms Quoted add any Manufacturers' or Sales Tax payable on the transaction under any effective statute.
TRANSPORTATION CLAIMS
The responsibility of this Corporation ceases upon delivery of goods m good order to transportation companies, and all goods are shipped at consignees' risk.
OROERS
The Corporation shall not be liable for any delay or failure in the delivery or shipment of products or for any damages suffered by reason of such delay or failure, when such delay or failure is, directly or indirectly, due to fire, flood, accidents, riots, war, embargo, labor stoppages, inadequate transportation facilities, shortage of material or supplies, regulation by Governmental authority, or any cause or causes beyond this Corporation's control.
GUARANTEE
We guarantee goods manufactured by this Corporation to the extent that we shall fur nish by freight new parts for any parts of such goods found defective in workmanship or material. No claim for labor in replacing defective parts or other consequential damage will be allowed. All replacement parts for material claimed defective will be invoiced in the usual manner, such invoice being subject to adjustment after alleged defective material has been returned to the Plant for inspection. No materials are to be returned without written permission. Goods of other manufacturers sold by us are not guaranteed by this Corporation.
CLAIMS
No claims under the above guarantee, or for variances from or shortages in orders will be allowed, unless presented within sixty (60) days after receipt of goods.
SPECIAL PRODUCTS
Items of special nature or products requiring special manufacture or supervision are not subject to change or cancellation after production is started.
RETURNED GOODS
Good material of standard manufacture must not be returned for credit without first securing written permission, and when so returned will be subject to a deduction of 109c for re-handling, and all transportation charges, including freight and cartage, will be paid by shipper.
Materials made on special order are not subject to return.
SHIPPING WEIGHTS
Weights are for customers' convenience only, are approximate and not guaranteed.
SE-3
2
Furnace I nformat
S:.a-
0r 23U 0 r, t - h 2 :
one fee scuare me: Too
Exa m
R c 21 s i e-r 5 B:*j C-
Biu Cse; Btj C.
Qic' q: r.
04131
eneral Terms
Furnace Selection Information
Amirican-c$tadai*d HEATING EQUIPMENT
Furnace Selection Information
aiII be found in
?D"GENERAL 'Ot included m
last Catalogue
Converting Requirements in Square Inches to Btu
o change withj this book any t including re
payable on the
good order to
y or shipment re, when such war, embargo, t! or supplies, Corporation's
i
i i
Capacities at Registers
Square Inch Ratings shown for all Sunbeam Gravity Furnaces are based on approximately one-half of capacity being supplied to first floor and one-half to second floor. For conditions where entire demand is all on one floor, or is substantially greater on one floor than the other, convert the square inch requirements of the installation into Btu by the following method:
Multiply square inch requirements of first floor by 111 ;
Multiply square inch requirements of second floor by 167;
Add the results and select Furnace having Btu capacity at register equal to or greater than the total.
Examples: 1. Assume one story building requires 675 square inches of leader pipe:
675 x 111 = 74,925 Btu at registers
we shall furworkmanship ential damage II be invoiced -ged defective o be returned ot guaranteed
in orders will
vision are not
without first ction of 10% tage, will be
tranteed.
2. Assume two story building with furnace heating only second floor requires 390 square inches of leader pipe: 390 x 167 = 65,130 Btu at registers
3. Assume two story building requires 565 square inches of leader pipe on first floor, and 185 square inches on second floor: 565 x 111 = 62,715 Btu at registers -- first floor 185 x 167 = 30,895 Btu at registers -- second floor
93,610 Total Btu at registers
Ratings
Square Inch Ratings are calculated by dividing the Btu Capacity at Registers by 136.
Btu Capacity at Registers for all Sunbeam Gravity Furnaces is 75% of Btu Capacity at Bonnet.
Btu Capacity at Registers for all Sunbeam Winter Air Conditioners is 85% of Btu Capacity at Bonnet.
3 SE-3
Hand Fired
American - Standard
heating equipment
Sunbeam Furnaces
SUNBEAM HAND FIRED FURNACES
CAST IRON Catalogue Page SI-6
KENWOOD Cast Iron Pipe Furnace
Furnace Number
D.am.
Fire Pot
t tRatmg
Square Inches
8tu Capacity
at Registers
Furnace Only
T rade Prices
Approx.
Shipping Weignt
Casmg and Hood
Trade Prices
Approx. Shipping
Weight
Furnace with Casmg and Hood
T rade Prices
Anorox. Shipping
Weight
A-1018-CO A-1040-CD A-1044-CO A-I048-CO A-I052-CD
18' 20'
22' 24'
26'
390
53.000 SIOT 00
699 $ 9 00
467
63,500
109 50
835
11 50
56 $M0 00 68 12' 00
75k5* 903
537
73.000
123 70
965
13 80
74 137 50 1039
597
81,200
1 38 40
1076
15 60
> 80
15* 00
1156
683
92,900
168 10
1376
18 90
92
187 00
1 468
STANDARO EQUIPMENT--Check draft, finishing collars, poker, draft regulator, chain and pulleys, asoestos cement, nuts and bolts.
NOTE: Cone type hoods are regularly furnished. Flat top or one pipe type hoods furnished when ordered without extra charge.
tSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO 8TU CAPACITIES AT REGISTERS."
KENWOOD Cast Iron Pipeless Furnace
Furnace Number
Diameter Fire Pot
6tu Capacity
Trade Prices Complete
Approximate Shipping Weight
A-1018-BO A-1040-8O A-1 044-60 A-1048-BO A-1052-8D
18' 20' 22' 24'
26'
70,700 84,700 97,300 108,100 123,800
$137 00 160 00 185 50 209 00
239.00
916 1121
1266
1410 1737
STANDARD EQUIPMENT--Register, check draft, poker, draft regulator, cham and pulleys, asbestos cement, nuts and bolts, warm-air and return-air extensions.
NOTE: Duplex Grates are regularly furnished with Kenwood Pipe and Pipeless Furnaces Triangular Grates are available at no additional charge, when ordered, specify with suffixes "CT" or ''ST", instead of "CD" Of "BD", respectively.
ARLINGTON Steel Pipeless Furnace
Furnace Number
Diameter Shell
Stu Capacity
Trade Prices Complete
Approximate Shipping Weight
BD-520
20'
90.500
$159 00
1102
80-522
22'
112.800
177 00
1157
80-524
24'
126,200
207 00
1255
80-527
27'
134,500
239 00
1369
STANDARD EQUIPMENT--Register, check draft, poker, draft regulator, cham and pulleys, asbestos cement, nuts and bolts, warm-nr and return-air extensions.
SEE PAGE 18 FOR AUXILIARY WATER HEATER COILS. PAGE 19 FOR HUMIDIFYING EQUIP MENT, PAGE 20 FOR TEMPERATURE CONTROL EQUIPMENT.
NOTE: Deduct 5% from price of Cast Iron or Steel Furnace Only, respectively, for omission of Grate Assembly, Ashpit Door, and Hand Firing Accessories.
SE-3
Sunbeam I
i '
' '
ru'nace Numoer
0.520
0-`552?74 ------------------------
STANDARO nuts and do::s
Furnace Numoer
D-8030 C-8034
STANDARD nuis and Dolts I
F i uce N 'ber
0-520-SC D-522-SC D-524-SC 0-527-SQ
STANDAPC draft regulator
NOTE De' Firing Accassc
NOTE Cor type hoods f nr with straight j SEE PAGE REGISTERS *
SEE PAGE MENT PAG:
04133
tm Furnaces
Furnace with ii>ng and Hood
Approx. ade Shipping ces Weight
0 00 1 00 7 50 4 00
7.00
755 903 1039
1156 1468
ain and pulleys, sd when ordered
APAClTlES AT
Approximate uppmg Weight
916 1121 1266 1410 1737
'uiieys, aabeatoa
:e Triangular BT", instead of
Approximate uppmg Weight
1102 115? 1255 1369
uMeys, asbestos
'YING EQUIP-
mission of Grate
\
Sunbeam Furnaces
A^RiCAN-c^tacdard
heating equipment
Hand Fired
F urnace Number
SUNBEAM HAND FIRED FURNACES
ARLINGTON Steel Pipe Furnace Catalogue Page ST-10
GALVANIZED ROUND CASING
Diam. Shell
f (Rating
Square Inches
Btu
Capacity at
Registers
Furnace Only
Casing and Hood
Furnace with Casing and Hood
Trade Prices
Approx.
Approx.
Shipping Trade Shipping
Weight Prices Weight
Trade Prices
Approx. Shipping
Weight
D-520 20* 499 67,000 (102 40 009 (12 60 70 (115 00 875
D-522
22*
622
04,600
115 20
056 13 80
75
129 00
931
D-S24
24*
696
94,600 136 40
921 15 60
77
152 00
990
0-527
27*
741
100,000 160 30 1021 17 70
81
106 00 1102
STANOARO EQUIPMENT--Check draft, finishing collars, poker, draft regulator, chain and pulleys, nuts and poits.______ __________________________________ ^________
Furnace Number
Diam. Shell
CLIFTON Steel Pipe Furnace Catalogue Page SJ3-I5, 17
GALVANIZED ROUND CASING
ttRitmg Capacity
Square
at
Inches Registers
Furnace Only
Casing and Hood
Furnace with Casing and Hood
Trade Prices
Approx.
Approx.
Shipping Trade Shipping
Weight Prices Weight
Trade Prices
Approx.
Shipping Weight
D-8030
30*
943 128,200 1225 50 1375 (21 50 101 $247 00 1476
C-S034
34*
1,024
139,300 300 50 1553 24 50
113
325 00 1666
STANOARO EQUIPMENT--Check draft, finishing coffers, poker, draft regulator, chain and pulleys,
nuts and bolts.
Smoke Tees for Clifton Steel Furnaces:
10* (for 6030, 80341 $4.00 Trade Price
ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page ST 1-12
SQUARE METAL JACKET
Furnace With Square Jacket and Flat Hood
/
Furnace
Diameter
t+Ratmg
Btu Capacity
Number
Shell
Square Inches
at Registers
Approx.
Trade
Shipping
Prices
Weight
D-520-SQ
D-522-SO 0-524-SQ D-527-SQ
20*
22' 24*
27*
499
67,000
(126 00
1059
622
64,600
142 00
1115
696
94,600
162 00
1205
741
100,800
197 00
1317
STANDARD EQUIPMENT--Squire Metal Jacket with inner liner, check draft, finishing collars, poker, draft regulator, chain and pulleys, nuts and bolts.
NOTE: Deduct 5% from price of Furnaee Only for omission of Grate Assembly, Ashpit Door, and Hand i Finna Accessories.
NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe type hoods furnished when ordered without extra charge. The Arlington "Squire" Model is furnished only j with straight side Hat top hood which is a part of the ticket. 1 HSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS."
SEE PAGE 18 FOR AUXILIARY WATER HEATER COILS. PAGE 19 FOR HUMIDIFYING EQUIP MENT; PAGE 20 FOR TEMPERATURE CONTROL EQUIPMENT.
5 SE-3
Oil Fired
American-Standard
heating equipment
Sunbeam Furnaces
Furnace Number
SUNBEAM OIL FIRED FURNACES
ARLINGTON Steel Pipe Furnace Catalogue Page S7-10
GALVANIZED ROUND CASING
tt Btu
Diam. Rating Capacity
Shell Square
at
Inches Registers
Furnace Only
Trade Prices
Approx. Shipping
Weight
Casing and Hood
Trade Prices
Approx. Shipping
Weight
Furnace with Casing and Hood
T rade Prices
Approx. Shipping
Weight
0-520-G or R D-522-G or R 0-524-G or R D-527-G or R
20' 22' 24' 27'
596
81,000 $102.40
601
$12.60
622
64,600 115 20
627
13 80
696 94,600 136 40 656
15 60
741 100,800 168 30
730
17 70
70
$115.00
671
75
129 00
702
77
152 00
733
81
186 00
811
Furnace Number
CLIFTON Steel Pipe Furnace Catalogue Page SI 3-17
GALVANIZED ROUND CASING
Diam. Shell
M Btu
Rating Capacity
Souare
at
Inches Registers
Furnace Only
Trade Prices
Approx. Shioping
We.Qht
Casing and Hood
Trade Prices
Approx. Shipping
Weight
Furnace with Casing and Hood
Trade Prices
Approx. Shipping
Weight
D-603O-G or R G-8034-G or R
30' 34'
943 1024
128,200 $225 50 139,300 300.50
948 1057
$21 50 24 50
101
$247 00
1049
113
325 00
1170
Smoke Tmi for Clifton Stool Furnaces: 10' (for 8030, 8034) $4.00 Trade Price
Furnace Number
D-520-SQG or S<?R D-522-SgG or S< >R 0-524-SOG or S< >R 0-527-SQG or SC>R
ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page Sll-12
_____________ SQUARE METAL JACKET______________
Diam. Shell
tt Rating
Square 1nches
Btu Capacity
at Registers
Furnace with Square Jacket and Fla t Hood
Trade Prices
Approx.
Shipping Weight
20'
596
81,000
$126 00
883
22'
622
64,600
142.00
916
24'
696
94,600
162 00
978
27'
741
100,800
197 00
1068
IMPORTANT: When ordering specify whether for use with Gun (G) or Rolary (R) Type Burner.
Grates and Fire Brick are not furnished. Special fire doors and burner doors are supplied. For Gun Type Burners, furnaces will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, furnaces will be equipped with cast iron hearth rings and
brackets, hearth plate, fire box liners and mineral wool insulation. NOTE: Sufficient space is not available on the standard hood for the total rating to be used by a number of small pipe take-offs. For such a condition 12' pipe take-offs with "Y" connections may be used.
NOTE: Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models. Flat top or one pipe
type hoods furnished when ordered, without extra charge. The Arlington "Square" is furnished only with
straight aide flat too hood which is a part of the iacket. ttSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT
REGISTERS." SEE PAGE 16 FOR ARCOFLAME OIL BURNERS AND CONTROLS, PAGE 17 FOR CORRECT SIZE
ARCOFLAME OIL BURNERS TO BE USED WITH THESE UNITS, PAGE 19 FOR HUMIDIFYING EQUIPMENT.
SE-3
6
Sunbeam Furnaces SUNE
F urnace Number
Oum, Shell
t*
Rat,-' Souar, Inche:
tD-520-SA tD-522-SA
D-524-SA
D-527-SA
20' 22*
24' 27'
596 622
696 741
Furnace N u mber
O'am Shell
----
Rat-r
Saua1 nche
D-8030-SA C-8034-SA
30' 34'
94 3 102*
AP
Furnace Number
tO-520-SQS TO-522-SQS
D-524-SQS 0-527-SQS
Furnace is equipped with t* and supports. Metal plates ir
When stoker is to be ir>sta hand fired models as shown o
tNOTE: These sites eauipp' NOTE: Sufficient apace is of small pipe take-offs. For s>.
NOTE: Cone type hoods a-f type hoods furnished when c straight aide flat top hood ri ttSEE PAGE 3--"CONVERi REGISTERS."
SEE PAGE 18 FOR Au X: MENT.
04135
am Furnaces
Furnace with asmg and Hood
rade nces
Approx Shippm
Weight
15 00
29 00 52 00 36.00
671 702 733
81 1
Sunbeam Furnaces
American-c$tat?dard
heating equipment
Stoker Fired
F urnace Number
SUNBEAM STOKER FIRED FURNACES
ARLINGTON Steel Pipe Furnace Catalogue Page S7-10
galvanized round casing
Diim. Shell
tt Rating
Square inches
Btu Capacity
at Registere
Furnace Only
Trade Prices
Approx. Shipping
Weight
Casing and Hood
Trade Prices
Approx. Shipping
Weight
Furnace with Casing and Hood
Trade Prices
Approx. Snipping
Weight
D-520-SA tO-522-SA
0-524-SA
0-527-SA
20* 22' 24' 27'
596 81,000 $102.40 752 $12 60
622
84,600 115 20
790
13 80
696
94.600 136 40
855
15 60
741
100,800 168 30
939
17 70
70 $115 00 822
75
129 00
865
77
152 00
532
81
186 00
1020
Fu. nace with asmg and Hood
rade 'ices
Appro*. Shipping WeiQht
*7 00
1049
Square Jacket at Hood
Appro*. Shipping Weight
883 916 978 1068
Burner.
ung and retiming hearth ring* and
sed by a number e used. at top or one pipe nnhed only with
RAPACITIES AT
CORRECT SIZE HUMIDIFYING
:
I
sw\_ '
cV_
4 }
Furnace Number
CLIFTON Steel Pipe Furnace Catalogue Page SI3-15, 17
GALVANIZED ROUND CASING
D'am. Shell
ft Rating
Square Inches
Btu Capacity
at Registers
Furnace Onfy
Trade Prices
Approx. Shipping
Weight
Casmg and Hood
T rade Prices
Appro*. Shipping
Weight
Furnace w.;n Casing ana Hood
T rade Prices
Appro* Shipping Weight
D-8030-S A C-8034-SA
30' 34'
943 1024
128.200 $225 50 139,300 300 50
1205 1355
$21.50 24 50
Smoke Tees for Clifton Steel Furnace*: 10' (for 8030, 8034) $4.00 Trade Pnce
101 113
$247 00 325 00
1 306 1460
Furnace Number
ARLINGTON "SQUARE" Steel Pipe Furnace Catalogue Page SI 1-12
SQUARE METAL JACKET
Diam. Shell
ft Ratmg
Square 1nches
Btu Capacty
at
Registers
Furnace w ith Square Jacket and Flat Hood
Trade Prices
Approximate Shipping
Weigrrt
tD-520-SQS ?D-522-SQS
D-524-SOS D-527-SQS
20'
596
81,000
$126 00
1015
22'
622
84,600
142 00
1 C52
24'
696
94,600
162 00
1145
27'
741
100,800
197 00
1255
Furnace is equipped with three steel chutes for firing from rear or left or right hand side, fire Dnc* lining and supports. Metal plates and gaskets are provided to seal cnutes not used.
When stoker is to be installed m front or below base of furnace, the above mooeis cannot be used a^c hand fired models as shown on page 5 should be ordered less grate assembly and ash oit door.
fNOT; These sues equipped with steel chutes on right and left side only.
NOTE: Sufficient space is not available on the standard hood for the total rating to be used by a number of tmali pipe take-offs. For sue* a condition 12* pipe take-offs with "Y" connections may be used.
NOTE Cone type hoods are regularly furnished with Arlington Pipe and Clifton Models Flat top or one pip* type hoods furnished when ordered, without extra charge. The Arlington "Square" is furnished only win straight ude flat top hood which is a part of the jacket.
ttSEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT REGISTERS."
SEE PAGE 18 FOR AUXILIARY WATER HEATER COILS; PAGE 19 FOR HUMIDIFYING EQUIP MENT.
7 SE-3
Gas Fired
AMERiCAN-c^tandard
heating equipment
Sunbeam Furnaces
Sunbeam Floor Furnac-
SUNBEAM GAS FIRED FURNACES
SHAWNEE -- Steel Heating Element Catalogue Page S18-19, 29
Furnace Number
For use w 11h Manufactured, Natura , or Mixed Gas
A.G A. Rating
Btu
1 nput per Hour
Btu Capacity
at Registers
M Rating
Souare
Inches
For use with L P. G.
A G A. Rating
Btu Input per Hour
Btu Capacity
at Registers
ft Rating
Souare Inches
Trade Pnc as w-th Standard E uipment
For use with
Manufactured, Natural, or Mixed Gas
For use with
L. P. G.
Control Combination
No G-1 Or
No G-2
Cont r 01
Combi nation
No G-3
Approx.
Ship ping Weight
SG-65
65.000 35.560
268
60,000 33,750
248
SG-80
80.000 *5,000
331
SG-105 105,000 59,060 435 105,000 59,060 435
SG-120 120,000 67,500 496 120.000 67,500 496
bU*l *u 1*0,000 78,750
579
$'09 50 120 00 137 50
14B 50 1 62 50
$138 00
166 00 177 00
270 303 361 407
477
Standard Equipment Includes:
Souare Metal Jacket.
Manual Shut-off Valve
Steel Heat'ng Element.
No. 850 BASO Automatic Pilot Switch.
Gas Pressure Regu'alor (Except for L. P. G.)
Ribbon Burner.
Draft Hood
_ Control Combination as specified.
Control Combination No. G-1 Control Combination No. G-2 Control Combination No. G-3
For use with Manufactured, Natural, or Mixed Gas.
For use with Manufactured, Natural, or Mixed Gas.
For use with L. P. G.
Detroit No. 411-CH Plain
Thermostat. Detroit No. V-57&-M Electric Gas
Valve and Transformer.
MHNo T-81-A Plain Thermostat. MH Solenoid Gas Valve and
Transformer:
V-835-D. except with SG-140 for Mfd. Gas
V-8*-C with SG-140 for Mfd.
Gas.
MH No. T-11-A Plain
Thermostat. MH No. V-155-A Motoriied Gas
Valve and Transformer. Special Control for 100% Safety
"Shut-off."
CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT.
OPTIONAL EQUIPMENT
Add to Above Trade Pncei
No. LA-H9-A Limit Switch (Airstat) for MH Controls (Catalogue Page S261 No. CA-80S Air Limit Cont-ol for DL Controls................................................................
$ 7 43 7 35
"SEE PAGE 3--"CONVERTING REQUIREMENTS IN SQUARE INCHES TO BTU CAPACITIES AT
REGISTERS." SEE PAGE 19 FOR HUMIDIFYING EQUIPMENT. PAGE 20 FOR OPTIONAL TEMPERATURE
CONTROL EQUIPMENT.
Instructions for Ordering
Orders must specify M ) Type of Gas df L. P. G , whether Butane or Propane). (2! 8tu Content. (31 Speci He Gravity (A) Control Combination Desired. f5i Elevation at which equ pment w<11 be operated if in excess of 2,000 feet.
RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2030 FEET FOR ELEVATIONS ABOVE 2,000 FEET, RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL.
=r\
r\
V
rir-t 1 Nc 31.
C-2: 2:.::: 0n-.25n 3tz: ::::z: 0
We z e z 5 e e - > Cute* a - : c :?r =; s-er Cc~\'o- Cc'-i Control Com b' r For Use * ;n V
Mj " rc P : ,,
Pilot Burner.
Control CorrFor Use w " V
le-` C' Nil Fc-
Mam a-c P 'ot .
PG-5 p ;t Gv 3C Ft Tc-*
; voca'a '
04137
n Furnaces
it
-jSfl
G. Apprpx Sh'PP'-g Weigni
roi
on G-3
00 j
CO |
270 3C3 361 *C7
477
P.io: Switch.
tlen No. G-3
G.
am Motor,;ed Gas 'crrner
1007 Safety
UNIT.
9 Trade Pr ces 7 43 7 35 3ACt Tl ES AT MPERATUPE
N^-"'
of 2,000 feet.
ABOVE 2,000 'EET ABOVE
Sunbeam Floor Furnaces
African-Standard
heating equipment
Gas Fired
SUNBEAM GAS FIRED FLOOR FURNACES
SAGINAW -- Steel Heating Element Catalogue Page S20-21, 30
0-20 0-35 0-60
0-79
For Use with
Mfd., Nat. Or Mixed Gas
Btu 1 nput
Hour
Btu
Output per Hour
A.G.A. Ratmg
For Use with L. P G.
Btu Inout
per
Hour
Output per
Hour
Trade Prices w th Standard Equipment
For Use with Butane-Air
525 Btu.
Btu
Input per
Hour
Btu Output
oer
Hour
With Con-
trol Combmat'On
A
With Con-
trol Comp-
i nation B
With Control Combinat'On
C
With W.th Con- Con-
trol trol
Comb- Combi nation mat'On
D| E
20.000 35.COO 50 noO 70,COO
14,000 24.500
35,000 49,000
20,000 14,000
35,000 24,500 150,000 135,000 57,000 39,900
20,000 50,000
14,000 (33 00 41 45
35,000 59 50 72 36
138 CO 46 45 64 60
77 35
$50 60" .... i$56 50
59 05*
64 95
$79 90 83 10
92 65 95 85
A np
Wgt.
no 135 1 86 2*8
fFor Bjiane Gas Input 38,000, Output 26,600.
Welded Steel Heating Elerrent. Outer and inner Casing.
Floor Register. Contro' Comp'nat'on as spec.Ted
Standard Equipment Includes:
Burner, P'pmg lighting Pod. Gas Pressure Regulator Eicept w-th L. P. G Draft Hood.
Control Combination A -- Manual Control with Locking Device
For Use with Mfd., Nat., or Mixed Gas.
Mam and Pilot Gas Cocks. PUo: Burner.
Control Combination B -- Manual Control with BASO Automatic Pilot
For Use with Mfd., Nat.. Mixed or L. P. G.
No. 831-1 BASO Thermostatic Mam and Pilot Valve--i'10C7c ''Shut-off").
Pilot 8urner.
Control Combination C -- General Controls Self-Energizing Set
For Use with Mixed Gas i800 Btu Minimum Con tent) or Natural Gas only.
Control Combination D--General Controls Self-Energizing Set
For Use with Mfd., Nat., or Mixed Gas.
(For Q-20 and Q-35 ONLY):
Mam and Pilot Gas Cocks. T-fiO-1 Thermostat. B-60-6 Automatic Gas Valve. PQ-6 Pilot Generator. 30 Ft Two-wire CaDie.
For Q-50 ana Q-70 ONLY.Mam and Pilot Gas Cocks. T-80-1 Thermostat. B-60-i Auiomatic Gas Valve. PG-i P lot Generator.
30 Ft. Two-wire Cable.
Control Combination E---Mlnneapolls-Honeywell Y-77-C Low Voltage Set
For Use with Mfd., Nat., Mned, or L. P. G
No. 831-1 BASO Automatic Main ano Pilot Valve--(1007c "Shut-off").
Pilot Burner. No. T-81-A Plain Thermostat. No V-835-D Solenoid Gas Valve and Transformer. 30 Ft. Two-wire Cable.
IMPORTANT NOTE Soecify ONLY Control Combination B or E for Use wiin Liquefied Petroleum Gas or Butane-Air. Deduct (3.35 from Trade Prices shown above for omission of Gas Pressure Regulator
^ when specified for L. P. G.
MH No. V-825-0 Gas Valve is replaced by No. V-835-A Gas Valve m Control Combination E when specified for use with L. P. G. pr Butane-Air
CONTROL COMBINATION BY LETTER DESIGNATION MUST BE SPECIFIED WITH EACH UNIT
Instructions for Ordering
Orders must specify it' Type of Gas (If L. P. G , wnethgr Bjtare or Propane1. 2 Btu Content. 31 Specific Gravity. i'4' Control Combination Desired. ,5. E'evat'on at which equipment w.ii be operated if m excess of 2.COO feet
RATINGS SHOWN ARE FOR ELEVATIONS UP to 2 OOC FEET for ELEVATIONS ABOVE 2.000 FEET. RATINGS SHALL BE REDUCED AT THE PATE OF 5 PEP CENT FOR EACH 1.000 FEET ABOVE SEA LEVEL.
9 SE-3
Hand Fired
AMERICAN-rt^tandard Sunbeam Winter Air
HEATING EQUIPMENT
Conditioners
SUNBEAM WINTER AIR CONDITIONERS
HAND FIRED
Un.il Number
0-5520 0-5522 0-5524 0-5527
ALLERTON -- Steel Heating Element Catalogue Page S34-37
i1 , Btu Caoac'iy at Refl<sters [
)
35,100
!
!
io7,3co
;
<
120,000
i
I 127,900 i
11
Trade Pnces with Standa'd Equipment
)
S-.a8 00
2t I 00 250 00 295 00
!
I j
Appro*,mate Sr. coi r g We ght
1205 ' 056 t 5 7C l 508
Uni} Number
D-30B0 C-3430-B
CLIFFDALE -- Steel Heating Element Catalogue Page S38-40
i|
Btu Capacity at Registers ] !l
Trade Prices Including
Smoke Tee and Standard Equipment
j j
j
162.500
| J<35 00
j
j
177,000
i
520 00
j
A ccrOAimate Shtob-ns We-ght
22)9 2*32
Squire Metal Jacket. Inner Casing and Rings.
Standard Equipment Includes:
Blower Cabinet. 8(ower, Belt and Pulleys. Rubber Mounted Motor with overload protection.
A.r Filters.
NOTE: Biower capmets on Ailerton and ChHdale Units can be attached to e-ther right or Jef; s-de of healing jacNet.
SEE PAGE IB FOR AUXILIARY- WATER HEATER COILS, PAGE 19 FOR HUMIDIFYING EQUIP MENT; PAGE 20 FOR TEMPERATURE CONTROL EQUIPMENT.
SE-3
to
I
t t
Sunbeam Winter Conditioners
SC
0-55:2-:; : O-t::*-G : a D-552:-G a- =
C-t<iC-:S : =? Cijtes *3' -s-.at":'' r h ea-th p;ate r : z rrj CPC'S i^d Z
SEE PAGE cc = W^Cr\AV; Cl e
U- :
U
v*. f'e:
OoC'-S c*3<=:-s=
S:w3-e Me'a . 3 ` I nr' Ca> i- : ~
NOTE 5 hea*'rg ;a:ee-
:
SEC ?:rr s VENT
04139
inter Air Jitioners
( I-a:e
/*\
I
ora.
G EQUIP-
Sunbeam Winter Air ^MiRiCAN-c^taitdard
Conditioners
HEATING EQUIPMENT
Oil Fired Stoker Fired
Unit Number
0-5522-G or R D-552A-G or R 0-5527-G or R
SUNBEAM WINTER AIR CONDITIONERS
OIL FIRED ALLERTON -- Steel Heating Element
Catalogue Page $34-36 For use with Gun or Rotary Type Burners
Btu Capacity at Registers
107,300 120,000 127.900
Trade Prices with
Standard Eauipment
S2H 00 250 00 298 00
Approximate Shipping Weight
1027 1139 1250
CLIFFDALE -- Steel Heating Element Catalogue Page S38. 40
For use with Gun or Rotary Type Burners
Unit Number
Btu Capacity at Registers
Trade Prices and Standard Equipment
Approximate Snipping Weight
D-3030-G or R C-3480-GB or RB
162.500 177,000
405 t>0 520 00
1775 1919 .
IMPORTANT: When ordering specify whether for use with Gun iG 1 or Rotary <R: Type Burner.
For Gun Type Burner, Units will be equipped with mineral wool insulation and supporting and retaining plates for insulation. For Rotary Type Burners, Units will be equipped with cast iron hearth rings and brackets, hearth plate, fire bo* liners and mineral wool insulation. Grates and Fire Brick are not furnished. Speca fire doors and burner doors are supplied.
SEE PAGE 56 FOR ARCOFLAME OIL BURNERS ANO CONTROLS, PAGE 17 FOR CORRECT SIZE
arcoflame oil burners to be used with these units.
______ _____
STOKER FIRED ALLERTON -- Steel Heating Element
Catalogue Page S34-36
Unit Number
D-5522-S A D-5524-SA D-5527-SA
Btu Capacity at Registers
107,300 120,000 127.900
Trade Prices with
Standard Equipment
(211 00 250 00 298 00
Approximate Shipping Weight
1 164 1284 1407
CLIFFDALE -- Steel Heating Element Catalogue Page S-38, 40
Unit Number
Btu Capacity at Registers
j Trade Prices j
| and Standard Equipment ]
Approximate Shipping Weight
D-3080-S C-348O-S0
162.500 177.000
| (435 00 1 520 00
1
|
2033
2215
Unit IS eouipped With three steel Chutes for firing from rear or left or rignt hand Side, fire crick lining and
supports Metal plates and gaskets are provided to seal chutes not used. When stoker is to be installed m front or below base of unit, the above models cannot be used and hand
ffed units as shown on page 10 should be ordered less grate assembly, ashpit door, and hana firing accessor-es
NOTE' These units equipped with steel chutes on right and left side only.
Square Metal Jacket. Inner Casing and Rings.
OIL FIRED OR STOKER FIRED Standard Equipment Includes:
Blower Cabinet. Blower, Belt, and Pulleys Rubber mounted motor with overload protection.
A*r Fitters.
NOTE Blower cabinets on Ane'ton and Cliffda'e Models can be attached to eitner r.ght or left S'de of heat.ng jacket
SEE PAGE 58 FOR AUXILIARY WATER HEATER COILS, PAGE 19 FOR HUMIDIFYING EQUIPWENT
$-3
Oil Fired
AwERICAN-e^tandard Sunbeam Winter Air
heati.VG equipment
Conditioners
SUNBEAM WINTER AIR CONDITIONERS
OIL FIRED
SARATOGA and WESTMORELAND ARCOFLAME OIL HEATING UNITS Steel Heating Element Catalogue Page $41-46
Unit Njmoer
1 j
E-H20-F
!
B-11 2*-BA
I
B -1 " 2 7 - B A
j
B-11 34-BC-18- W 1
B-113--BC-l8->, !
B-H3<-BC-2l-* 1
Burner Model Number
C-iS C-iS C-iS c-:s X L-1 S L-iS
! No22ie S>ae Gallons per Hour
1 25** 1 SO 2 00 2 50 j 3 00 i 3 SO
Btu Capacity a: Registers
95 000 tso.ooo 200.000 20,GOG 285,000 330,000
Trade Prices witn Standard
Eduioment
$338 20 452 70 515 20 560 20 587 45 62 20
Aoorcuima'e S h; 5Qc ng Weight
1 1 30 1 552 1833 2'74 2255 2401
Supplied with Soeciai Turpufator Attachment.
Set Dunn 80-90 ids pressure. The Saratoga, No. -1 ' 20-F, has Heat mg Element and Blower enclosed in single Jacket Tne W estmcu e-
land Units have Heating Element enclosed in a seoarate Jacket and Blower enclosed m a caomet wnich can be attached to either ngnt or left side of Heating Jacket.
Standard Equipment Includes:
Squa'e Metal Jacket. Inner Lining. Blower. Belt, and Pulleys.
Rubber Mounted Motor with Overload Protection.
Air Filters. Draft Stabihier. Heat Lib-Q-Raior Molded Refractory Combustion
Chamoer.
ARCOFLAME 01 Bu'ner and Noule, CA-701 Stack Control. No 20 Control Set (<ii-CH Thermostat, CA-8f5 Rlower and Limit Control).
NOTE. Delroif *tl-CDN Day-Night Heat Compensated Thermostat and 772 Tem-Clock Combination may be substituted fo' atl-CH Thermostat m Control Set No 20, the suffix "A" after Control Set Number wi|, designate this substitution. If desired, add $17.63 to the above Trade Prices.
SARATOGA and WESTMORELAND -- Steel Heating Element Catalogue Page S4M5
Without Oil Burner or Controls
Unit Number
E-112ChF 8-j :?a-8A B-i 127-BA B-1 ', 3*-BC-18- '/i B-1 i 3A-BC-18- M B-11 34- BC-21 - *\
Recommended Noaale Sue Gallons per Hour
1 25 1 50 2 00 2 50 3 00 3 50
Biu Capacity at Registers
95,000 1 50,000 200,000 240,000 285,000 330,000
Trade Prices with Standard
Equipment
$195 50 307 00 368 00 4 \ 3 00 425 25 480 00
Approx, mat e S hi ppi rg VN e1 ght
675 1263 1521 1 B61 1579 2014
Standard Equipment Includes:
Square Metal Jacket. Imer Lining. B.owa\ Bolt, and Pulleys
Rubber Mounted Motor with Overload Protection,
Air Filters. Mineral Wool Insulation
Refractory Brick.
SEE PAGE 15 POP aCOFlaM BURNERS AND CONTROLS RAGE I? FOP H A T liB-O-PATOR COMBUSTION CHAMBERS. PAGE IS FOR HUMIDIFYING EQUIPMENT.
SE-3
s
Sunbeam Winter Ai Conditioners
SUN!
SEN:
Steel Heatin'.
1
( Per ,,S9 w -
] Ml,:.
Nqmjer | AC A j Rating 1 Stu ! n;_I ; per hcj-
?,! -70
$ 1-85
SL-105 si-i:s c -`SO
' ;
7c oc: 85 OCC
105.030 !" '
5: o: :
WYAM
Steel Heo1
i
* set ^ *e d n ,
Un-t
N U m. o 6 r 1 AG A
i Rat -g
' Biu Tb.: : 30r Ho.'
SUA-55* ;
S JA-7C* , S'JA-85* * SU- iv5
c.t
73 3'3'C 85,3-3 3 iCc.OGu
A~or L P. G., spec fr Cc
Meta! Jacket. Steel Heating E!eme-' Gas Pressure Regulator
l. P. GJ
Control Combination
Por Use w!" Wa*ya:t.'or M . r s c Gas
Detroit No. * 11 -C m
^
Thermostat
Detroit No V-570 ':
Valve and Trar5fcr--.e'
Detroit No. GA-315 5 :
Limit Sw;tch.
#Ccn;rof Ccmoma*. s"1 -~ ~CCNT?0^ c"5~m
SuA-55. S'JA.tc a- : : be 'ocated cn !>'' s in.at will ce SuCS'.tu.'eo j
SU-1C5 Wnr;;i;t U n
SEE PAGE ' 5 FO3 C PERATURE COn:3a
O'oe's ~. v
RATING? S~ ' - PATiNGS 3hi.. BE -LEVEL.
04141
ter Air lioners
i 1 30 :Sb2 633
21 7*
22 65
:<c
Westmorewhicn can
cfTiomation el Nuuimi
Q
cumate ig Weight
876
353 521
861 'S'S
)
Sunbeam Winter Air Conditioners
AwRiCAN-i$tadard HEATING EQUIPMENT
Gas Fired
SUNBEAM WINTER AIR CONDITIONERS
SENECA -- GAS FIRED -- Catalogue Pago S47-48, 60 Steel Heating Element -- With Blower at Right of Heating Compartment
Unit Number
SL-70 SL-85 St-105 Sl-125 SL-iSO
Trade Prices with Sid. Equipment
For use with Manu
factured. Natural, or Mixed Gae
A.G.A. Rating
Btu Inout per Hour
Btu Capacity
at Registers
For use w th L. P. G.
A.G A. Rating Btu Input
per Hour
Btu Capacity
at Registers
For use with Manu factured, Natural, or Mixed Gas
Control Combination
No. A-1 Or
No. A-2
For use with
L. P. G.
Control Combi nation No. A-3
Approx.
ping Weight
70,000 85,000 105,000 125,000 1 50.000
47,600 57.800 71,400 05.000 102,000
61,000
105,000 125,000
41,460
71.400 85.000
5198 00 215 00 228 00 250 00 275 00
(226 50
256 50 278 50
WYANDOTTE -- GAS FIRED -- Catalogue Page S49-50. 60 Steel Heating Element --With Blower Under Heating Compartment
396 414 463
505 590
1
-a 1
zl
For use with Manu
factured, Natural, or Mixed Gas
A.G.A. Rating
Btu Input per Hour
Btu
Capacity at
Bonnet
For use with L. P. G.
A.G.A. Rating
Btu Input Per Hour
Btu Capacity
at Bonnet
Trade Prices with Sf
For use with Manu factured, Natural, or Mned Gas
Control Combination
No. A-1 Or
No. A-2
touipmeni
For use with
L. P. G.
Control Combi nation No A-3
Approx. Ship ping
Weight
SUA-55*
SUA-70*SUA-05* SU-105
55,000
70,000 85,000 105,000
44,000 56.000 68.000 84,000
55,000 61,000
*05,000
44,000 48,800
84,000
*177 00
193 00
210 00 223 00
A *221 50
251 SO
295 393 423 500
A.For L. P. G-. specify Control Combination A-4 # and add *15.00 to Trade Price of SUA-55 with A-l Controls.
Standard Equipment Includes:
Metal Jacket.
Manual Shut-off Valve.
Steel Heatmg Element.
Blower-Motor Unt.
Gas Pressure Regulator (Except for Air Filters.
L. P. G.)
Control Combination as specified.
No. 850 BASO Automatic Pilot Switch,
Ribbon Burner.
Draft Hood.
Control Combination No. A-1 ( Control Combination No. A-2 | Control Combination No. A-3
For Use w-th Manufactured, Natural, For Use with Manufactured, Natural,
or Mixed Gas
or Mixed Gas*
For Use with L. P. G.
Detroit No. 411-CH Piam
Thermostat. Detroit No. V-570 Electric
Valve and Transformer. Detroit No. CA-815 Blower
Limit Switch.
Gae and
MH No T-81-A Plain Thermostat. MH So'enoid Gas Valve and
Transformer?
V-835-A, except with SL-150 for
Mid. Gas. V-84-A with SL-150 for Mfd.
Gas.
MH No. LA-101-A Blower and Limit Switch.
MH No. T-ll-A Plain Thermostat. MH No. V-155-A Motorized Gas
Valve and Transformer. MH No. LA-101-A Blower *n<j
Limit Switch.
Special Control for 100% Safety "Shut-off "
Control Combination A-4 aame as A*t, except with 100% Safety "Shut-off" and valve equipped for L. P. G.
CONTROL" COMBI NATION"by NUMBEfT MUST BE SPECl FI ED ~wTth ~ACH ^JnItT
*SUA-55, SUA-70 and SUA-85 WYANDOTTE Units are regularly furnished with filter frame which may be located on either s*de. If desired, and so specified on order, special Air Filter 8ase for bottom return a<r m:et will be substituted at no additional charge.
SU-J05 Wyandotte Unit is eouipped with 2 filter frames, one on each side.
SEE PAGE f9 FOR COMBINATION "S" FLOAT HUMIDIFIER, PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.
Instructions for Ordering
Orders must specify H i Type of Gas (If L. P. G., whether Butane or Propane (2' Btu Content. (3i Specific Gravity. (4 i Control Combfnation desired. (5i Elevation at which equipment will be operated if m excess of 2.000 leet
RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2.000 FT. FOR ELEVATIONS ABOVE 2,000 FT . RATINGS SHALL BE REDUCEO AT THE RATE OF 5 PER CENT FOR EACH 1.000 FT. ABOVE SEA LEVEL.
13 SE-3
Gas Fired
AMSRICAJtf-^tatldard Sunbeam Winter Air
heating equipment
Conditioners
Unit Number
SUNBEAM WINTER AIR CONDITIONERS
MOHAWK --GAS FIRED Catalogue Page S51-54. 60 Cast Iron Heating Element
For Use wth Manufactured, Natural, Mixed or L. P. G.
A.G.A. Rating
Btu nout per Hour
Btu Capacity
at Registers
T ade Prices with Standard Eduo ment
For Use with Manufactured, Natural, For Use with
or Mixed Gas
L. P. G.
DL Control Comb. No. A-1
DL Control Comb. No. A-6
MH
Control Comb. No. A-7
MH Control Comb. No. A-8
MH Control
Comb. No. A-9
Approx. Shipping Weight
K-60 KSO K-100
60,000 80,000 100,000
40,800 54,400
68,000
1212 00 235 00
260 00
4229 00
252 00 276 50
$212 OO 235 00 260 00
*229 00 252 00 276 50
*246 00 270.50 292 00
K-120 K-1 SO
K-180
120,000 1 SO,COO
180,000
81,600 )02,000
122,400
290 00 330 00 375 00
306 50 346 50 391 50
290 00 330 00 375 00*
306 50 346 50
391 50
322 00
363 00 408 00
K-200 K-2*0 K* 300
200,000 240,000
300,000
36,000 '63.200 204,000
405 00 457 00
542 00
422 00 4 74 00
559 00
405 00*
422 00 4 74 00
559 00
438 50 4 90 50
573 00
For Use wit* Muse Gas (800 Btu Minimum Content) or Natural Gas Only,
Standard Equipment Includes:
Meta' Jacket.
Manual Shut-off Valve,
Cast iron Heatmg Sections.
Air filters.
Gas Pressure Peculator (Except for L. P, G.)
Ribbon Burners.
8iower-- Motor Unit.
Draft Hood.
No. 322 8A$0 Automatic Pilot Valve--for Second and Successive
Sections with DL Control Combination No A-6, for Each Section
with DL Control Combination No. A-1, and MH Control Combina
tions No A-7 and No. A-8.
Nc. 850 8ASO Automatic Pilot Switch for Each Section with MH
Control Combination No. A-9.
Control Combination as specified.
527 78S 84 7
905 1239 12*6
1557 1605 1883
Control Combination No. A-1 Control Combination No. A-6
For Use with Manufactured, Natural, or Mixed Gas
For Use with Manufactured, Natural, or Mixed Gas
Detroit No. 411-CH Plain Thermostat.
Detroit No. V-570 Electric Valve and Transformer.
Detroit No. CA-815 Blower Limit Switch.
Gas and
Oetroit No. 411-CH Plain Thermostat.
Detroit No. 566-VPThermotor Gas Va've. Limit Control. Trans former and Vapor Tension Ther mostats Pilot for First Section.
Detroit No. CA-810 Blower Switch.
Control Combination No. A-7
For Use with Manufactured, Natural, or Mixed Gae
MH No. T-81-A Plain Thermostat. MH No. V-835-A Solenoid Gas
Valve and Transformer (Except No. K-240 ana No. K-300'. MH No LA-101-A Blower a"d Limit Switch.
Control Combination No. A-8
Control Combination No. A-9
For Use with Mfd., Nat., or Mixed Gas.
MH No. T-il-A Plain Thermostat. MH No. V-15S-A Motorized Gas Valve and
T nnsformer. MH No. LA-101-A Blower and Limit Switch.
For Use with L. P. G.
MH No. T-il-A Plam Thermostat. MH No. V-155-A Motorized Gas Valve and
Transformer. MH No. LA-101-A Blower and Limit Switch. Special Control for lOQE^ Safety "Shut-off."
CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT.
SEE PAGE 19 FOR HUMIDIFYING EQUIPMENT; PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.
Instructions for Ordering
Orders must specify (it Type of Gas (If L. P. G., whether Butane or Propane). i2> Btu Content. ' 31 Specific Gravity. (4. Control Combination desired. '51 E'evation at which equipment w.il be operated if m excess of 2,000 feet.
RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2.000 FEET. FOR ELEVATIONS ABOVE 2.C00 FEET RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH t.000 FEET ABOVE
SEA LEVEL.
SE-3
M
C_ Sunbea
Conditii
').
OeC
M_- 3 Ci;-
)C
Fc' Use
MH No MH
MH N:
F 3 r- Us
De'-o : Os1/:-
Tra--
'ea*.
)
a: r.o i SEE
CON'
)
04143
ir s
*9
- '1
-o
t?
7 is JOt
ntj
o
sc
JCO
v'E
Sunbeam Winter Air A.M rican- <tcLttdavd
Conditioners
HEATING EQUIPMENT
Gas Fired
Unit Number
SUNBEAM WINTER AIR CONDITIONERS
CHIPPEWA --GAS FIRED -- FACTORY ASSEMBLED Catalogue Page S55, 60
Cast Iron Heating Element With Blower Under Heating Compartment
For use w<th Mfd.. Nat., Mned, L. P. G. or
Butane-Air (525 Btu).
A G.A. Rating
Btu Input per Hour
Btu
Capacity at Bonnet
Trade Prices with Standard Equipment
For Use with Mfd., Nat , or
Mixed Gas
Control Comp.nation
No. A-7 or A-16 No A-16E
For Use with L P. G or
Butane-Air '525 Blui.
Corn oi Combination
No A-17
Approx, Shipping Weight
KUA-60
60,000
48,000
$229 00
$253,50
$247 35
500
#Deduct $3.35 from Trade Pnc for omission of Gas Fressure Regulator when spec.fled for use with L. P. G.
Standard Equipment Includes:
Metal Jacket.
Manual Shut-oH Valve.
Cast iron Heating Element.
Blower-Motor Una.
Gas Pressure Regulator--(Except for L. P. G.j.
Air Filters.
Control Combination as specified.
Ribbon Burner.
Draft Hood.
BASO Automate Pilot Valve with Control Combinations No. A-7, A-16 and A-16E.
BASO Automatic Pilot Switch with Control Combination No. A-17.
Control Combination No. A-7
Control Combination No. A-16
For Use with Manufactured, Natural, or Mixed Gas. For Use with Manufactured, Natural, or Miaed Gas.
MH No. T-81-A Plain Thermostat. MH No. V-835-A Solenoid Gas Valve and Trans
former. MH No. LA-1QI-A Blower and Limit Switch.
Detroit No. 411-CH Plain Thermostat. Detroit No. V-574-F Electric Gas Valve and Trans
former.
Detroit No. CA-810 Blower Switch.
Gas Valve has mechanical lima and manual opening feature.
Control Combination No. A-16E
Control Combination No. A-17
For Use with Manufactured, Natural, or Mixed Gas.
For Use with L. P. G. or Butane-Air (525 Btu).
Detroit No. 411-CH Plam Thermostat. Detroit No. V-574-F Electric Gas Valve and
Transformer.
Detroit No. CA-810 Blower Switch. Electric Pilot Igniter. Gas Valve has mechanical limit and manual opening
feature.
Detroit No. 411-CH Plain Thermostat. Oetroit Electric Gas Valve and Transformer-
No. V-571 for L. P. G. No. V-570 for Butane-Air (525 Btu).
Detroit No. CA-815 Blower and Lima Switch. Special Control for 10O9 Safety "Shut-off."
CONTROL COMBINATION BY NUMBER MUST BE SPECIFIED WITH EACH UNIT.
The Chippewa Unit is regularly furnished with filter frame which may be located on either side,
ff desired, and so specified on order, special Air Filter Base for bottom return air inlet will be substituted at no addaional charge.
SEE PAGE 19 FOR HUMIDIFYING EQUIPMENT; PAGE 20 FOR OPTIONAL TEMPERATURE CONTROL EQUIPMENT.
Instructions for Ordering
Orders must specify (1) Type of Gas (If L. P. G., whether Butane or Propane). (2) Btu Content. (3) Specific Gravity. (4) Control Combination desired. (5) Elevation at which equipment will be operated if m excess of 2,000 feel.
RATINGS SHOWN ARE FOR ELEVATIONS UP TO 2,000 FEET, FOR ELEVATIONS A80VE 2 000 FEET, RATINGS SHALL BE REDUCED AT THE RATE OF 5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL.
15 SE-3
04144
Arcoflame Burners
AFRICAN-Standard
HEATING EQUIPMENT
Arcoflame Burners
ARCOFLAME OIL BURNERS
COMPLETE with
STANDARD ARCOFLAME BURNER CONTROL SET AND NOZZLE* Catalogue Page S46
(A Standard Arcoflame Burner Control Set Must Be Purchased With Each Arcoflame Burner)
Modef Number
C-1S
C-2S
With Control Set Number
19 For Gravity Furnaces
20 For Winter A.f
Conditioner
Contents of Arcoflame Standard Control Sets
No. 411-CH Thermostat. No. CA-805 Air Limit Control No 411-CH Thermosiai. No. CA-815 Combination Blower amj Limit Control,
T'ade Prices
$124.50
130 70
C-3S
For Use on 115 Volt, 60-Cycle Current
MAXIMUM CAPACITY 3 00 GALLONS OIL PER HOUR Approximate Sh pping Weight 140 pounds
L-IS L-3S
19 For Gravity Furnaces
20 For Winter Air
Conditioners
No 411-CH Thermostat. No CA-805 Air Limit Contro'
No. 411-CH Thermostat.
No CA-815 Combination Slower amt Lnmt Control
For Use on 115 Volt, &0*Cycle Current
MAXIMUM CAPACITY 7.00 GALLONS OIL PER HOUR Approximate Shipping Weight 165 pounds
:37.50 M3.70
IMPORTANT: When subst'tution of 41 1 - CON ana 772 combination <s made for 411-CH such eontrc' sets wdi be designated by suffix "A" after control set number If desired, add 5 5 7 53 to above Trade P*ices.
When ordering Arcoflame Oil Burner be sure to specify Nor*!e s<ze desired, Thermostat cable not furnished.
IMPORTANT NOTfCE
Trade Prices lor Arcoflame Burners and Standard Burner Control Sets as shown above include, m aodwon
to the Norzie and Controls as listed, a No. CA-701 Arcoflame Stack Control. Arcoflame Burners will be solo only when ordered m combination with one of the Arcoflame Stardard
Burner Control Sets, as shown above. Additional Arcoflame Controls may be purchased separately at Trace Prices shown below.
'When Arcofltme Burner isordirert with Noriie Sires of 1.25 and 1.35 Gallons per Hour, Soecia! Turcviator
Attachment i$ furnished at no additional charge. Arcoflame CM Burners are approved by the National Board of Fire Underwriters and comply with Comms'c^ai
Standards CS-75. IMPORTANT NOTE Motors and Controls regularly furnished are for 115 Volt, 60-Cycfs A. C,
CONTROLS FOR ARCOFLAME OIL BURNERS Catalogue Page S61-62
Trade Prices---When Ordered Separately
Stock Number
Description Standard Controls -- 115 Volt, 60 Cycle
) Trade | Prices
CA-701 CA-702
*1 l-CH 411-CDN
1411 -TO 772 CA-805 CA-815
CA-810 CA-295
Stack Control (Intermittent Ignition!.
....
I
Stack Confoi iConstani (gmlionj . .
i
Detroit Heat Compensated Thermostat Low Voltage Scale 40'-90'F.)
|
Detroit Day-Night Heat Compensated Thermostat 'Scale 40C-90CF.) ,
Detroit Night Turn-down Assembly ....
Tem-Ciock with T'ansformer
i
Detrct Au Limit Control ( High VaCage> fSca'e I90--3005F.' iStoo 250'F.i
1
JDetroit Combination Blower and Limit Control (High Vonagei iScaie Blower
7SC*2255, Limit 1 OO'-SOO1*. Stop 20CcF.l
}
Detroit Furnace Blower Control (High Voltage! (Scale 75-275:iF.)
i
Detrct Relay Transformer
-
$27 oo 2b Cb 6 56 9 *5 1 35 16 73 7 35
1* a
8 4C 8 78
411 -CON The rmostat is used only in combination with 772 Tem-Clock JOrder 411 -TO and 772 Tem-Ciock to convert existing 41 1-Ch Plain Thermostat to Automatic Day-N.gnt
operation
SE-3
16
04145
t
Combustion Chambers
AwiRiCAN-c^taitdard HEATING EQUIPMENT
Arcoflame Oil Burners
oo
I
O'
_
\. \Jr
ARCOFLAME CONVERSION OIL BURNERS
FOR USE WITH SUNBEAM GRAVITY FURNACES
KENWOOD
A-1018-CD or BO A-1040-CD or BO A-1044-CO or BO A-1048-CO or BO A-1052-CO or BO
C-2S C-3S C-3S C-3S C-3S
ARLINGTON ANO ARLINGTON ''SQUARE"
D-520-G or O-520-SQG D-522-G or 0-522-SQG 0-524-G or D-524-SOG
0-527-G or D-527-SQG
C-2S C-2S C-2S C-2S
CLIFTON
D-8030-G C-8034-G
C-2S L-3S
FOR USE WITH SUNBEAM WINTER AIR CONDITIONERS
CLIFFOALE
ALLERTON
0-3C80-G C-3483-GB
C-2S L-3S
0-5520
0-5522-G D-5524-G D-5527-G
C-2S C-2S C-2S C-2S
Combustion Chambers not furnished. See Arcoflame Oil Burner Installation ana Service Guide for sug gested sue and shape.
NOZZLES AND STRAINERS
FOR CONVERSION OIL BURNERS
For Modal C
-- Gals, per Hr. Spray Angle
For Model L Gals, per Hr. Spray Angle
FOR SARATOGA ANO WESTMORELANO UNITS
Untt Number
Ga's per Hr. Spray Angle
1.25 1.35
1 50 1 65 1 75 2 00 2 25 2 50 2 75 3 00
80 80* 60* 80 60 60 60s 60 60 60
3 00 3 50 4 00 4 50
5 00 5 50
6 00 6 50 7 00
60s E-1I20-F 60 B-1124-BA 60 B-1127-8A
60 B-11 34-BC-18- H 60 8-1134-8C-18- ** 60 B-1134-BC-21 - * 60 |
60 60
1 25* 1 50 2 00 2 50
3 CO 3 50
80
60 80 45
60 60
Set Pump at 60-90 lbs. pressure if 1 25 Nozzle is used.
When these Nozzles are used in Model "C" Arcoflame Burners, the Special Turbuiator Attachment should be used. Special Turbulator Attachment furnished at no additional charge when these nozxiee are supplied as part of one of the Standard Arcoflame Burner Control Sets shown on page 16.
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS FOR SARATOGA and WESTMORELAND UNITS
Trade Prices -- When Ordered Separately
Slock Number
0S 1s 2S
3S
Sunbeam Unit Number
Max. Gals, per Hour
E-1120-F
8-1124-BA
8-1127-BA B-11 34-BC-18- H
B-11 34-BC-18- * B-11 34- BC-21 -
7
1 50 1 75 2 25
3 75
Trade Prices
SI 2 00 15 00 16 50
18 50 SE.-3
04146
Water Heater Coils
A MFmrAN-^taittfard Gas Conversion Burners
heating EQUIPMENT
Blower-Filter Units
AMERICAN GAS CONVERTOR
FOR WARM AIR GRAVITY FURNACES OR WINTER AIR CONDITIONERS Catalogue Page S56
Convenor Number
A.G.A. Maximum Input Rating 8tu per Hour
Warm Air Output at Bonnet
Btu per Hour
Trade Prices with Regular
Equipment
Approximate Shipping Weight
13-A-F 1 5-A-F 19-A-F 23-A-F
150,000 180,000 240,000
360,000
115,000 135,000 180,000 270,000
*100 00 104 75
110 55 126 30
158 180 212 277
Regular Equipment includes complete burner assembly with refractory daffies and front panel assembly, No. 566 Thermotor throttling valve with thermo-pilot and uoper limit control, gas pressure governor and DL No. 411-CH piam room thermostat.
NOTE tf Thermostat is not desired, deduct *8.55 from above Trade Prices. For Winter Ai' Conditioners. For Gravity Furnaces, reduce outputs 6%.
RATINGS SHOWN ARE FOR SEA LEVEL. RATINGS SHOULO BE REDUCED AT THE RATE OF
5 PER CENT FOR EACH 1,000 FEET ABOVE SEA LEVEL.
SUNBEAM BLOWER-FILTER UNITS
Catalogue Page S22-27
Unit Numoer
Diameter of Wheel
Motor Horsepower
Trade Prices
With Cabinet Less Cabinet
and Filters
and Filters
Approx. Sh.ppmg Weight
W<th Cabinet Less Cabinet
ano Filters
and Filters
D-1- 9
D-1-104 0-1-12 D-1-15
1-18-F8 1-21-F B
9* iov 12' 1 5'
18' 21'
* 64 00
* 48 50
ii
72 00
54 50
H
86 00
63 50
H
124 00
98.00
H
168.00
139 00
255 00
188 50
1*2 146 181 241
478 633
69 73 9* 121 287
392
Standard Equipment includes pulleys, belt and resilient mounted blower and motor. MH No LA-<I?-A or Detroit Lubricator CA-810 blower awitch-smgie pole tan be furnished at additional
Trade Price of $8 40.
AIR FILTERS FOR REPLACEMENT
Catalogue Page S57
Standard Filter Sizes
20' 25' 20' 20' 16' 25' 16' 20' 15' 20' 10' 20'
1' Thick
80 80 80 80 .70
2* Thick
*1 33 1 16 1 16 1 16 1 16 97
NOTE: Filters as shown at left are packaged >n cartons cf tweive (12) of
AUXILIARY WATER HEATER COILS
Catalogue Page S28, 57
No. of Coif
For Gravity Furnaces and Winter Air Conditioners For Use m Coa! Burning Units Only
Approximate Shipping Wt.
Trade Prices
No. 1 x 22' Straight No. 1 x 24' Straight No. 1 x 26' Straight
Nc. 1 Forme<3
No. 2 Formed No. 3 Formed
tNo. A-1018-CD.-8D
........................................
tNo. A-1040-CO.-BO, A-1044-CO.-BO
tNo. A-1048-CD.-BD. No. A-1052-CD.-BD; No. C-8034.
No. C-3480-B.. .
No. D or BD-522; No. D or BD-524. No. D-S522,
No. 0-5524
tNo. D or BD-527. No. D-8030; No. D-3000. No. D-5527
tNo. D or BD-520: No. D-5520 .
6 4 IbS. 7 Ifcj.
7\i fbs.
7 i- IbS. 7 lbs. 6 4 ids.
*1 30 1 40
t 40
3 50 3 80 3 45
In ordering, be sure to specify the coif number and the furnace or conditioner witn which it is to be used.
For example, No. 1 * 25' Straight Coil, for No. A-1048-CD Furnace, or No. C-3460-B Winter Air Conditioner. The same coils are used with both pipe and pipeless furnaces.
SE-3
lers nits
ply,
OL ")
OF
O
Sunbeam
AMRICAN-e>3>tadard
HEATING EQUIPMENT
Humidifying Equipment
Hurmflifier I NumberI
HUMIDIFYING EQUIPMENT
j Description| Trade Prices
FOR GRAVITY FURNACES:
WA Catalogue Page S28
! Automatic Drip Humidifier:
j Se'f-contained Heat Actuated Feed Valve Assembly, Metal Pan, Shut*oH Valve. Water ime and Couplings.
' Water Pan for ARLINGTON "SQUARE"
' Water Pan win Cast Iron Frame that attaches to Jacket
S 9.25
$ 3 50
FOR WINTER AIR CONDITIONERS:
H.4' Catalogue Page S58
S-4QQ Catalogue Page S58
Automatic Spray Humidifier:
(For use with ail Winter Air Conditioners anceot Seneca and Wyandotte Units)
No. H-t* Fnez Hunttdisiai. No. V-B37-A Solenoid Water Valve including Transformer. 2 No. 390 Water Strainer*. ( No. 26 Water Pressure Reducing Valve. j No 50 Assembly including' Tubing and Fittings, Shut-Off Valve, * I Spray Nozzles with individual Shut-Off Valves. Spray Pan with
capacity Adjusting Plate. Nozzle Cleaning Rod, 3 Rubber Caps for 1 Spray Nozz'es not m use.
Float Humidifier:
Evaporating Plates. Evaporating Pan. Water Reservoir with Float and Valve. Fienbie Tube and Pipe Clamp Valve.
S-401 : For SUA-55, K-SO, KUA-60 S-402: For D-552C, 0-5522, D-5524; E-1120-F, SL-70 SL-B5.
SL-105. SL-I25. SL-150, SUA-70. SUA-85 SU-I05.-K-80.I K-100, K-120. K-1 50.
I S-403 : Far D-5527, B-1I24-BA, K-180, K-200, K-240. I S-404: For D-3080. B-H27-BA; K-300.
S-405: For C-3480-8; B-1134-80-18- H.-18-(<.-21-51.
I____________Eitra Evaporating Plates, Trade Price Each S 17
*<5 00
tu 65 11 65 12 75 t3 75 15 00
Water Pan tor ALLERTON, CLIFFDALE. SARATOGA I
and WESTMORELAND
|
Water Pan with Cast Iron Frame (hat attaches to Jacket-
!
J 3 50
fee
*S E-3
04148
Temperature Control Equipment
AwERICAN-c^tandapd
heating equipment
Sunbeam
Combination |
Description
[ Trade Prices
MX Catalogue Page $29
A-1 K Catalogue Page S2
FOR ALL HAND FIRED GRAVITY FURNACES:
Mechanically Controlled
MH Metaphram Oraft Control. A self-contained mechanic*' draft and check regulating instrument
Thermostatically Controlled
MH No. T-81-A Plain Thermostat. MH No. LA-U9-A Limit Switch (AirstaO. MH No M-87-A Damper Motor with Transformer.
No 933 Accessories (Chain. S-Hooks and Pulleys'.
4 a *o
433 '5
FOR ALL HAND FIRED WINTER AIR CONDITIONERS:
Mechanically Controlled
Mk
MH Metaphram Draft Control.
Catalogue PageS59
A seif-contamed mechanical drift and check regufatinQ instrument
Catalogue Page S59
No CA-8'0 DL Blower Switch. No LA-i2-A MH Slower Switch (Furnacestat).
When Room Thermostat Draft Controls are net used, a blower switch s necessary for staMmg and s to DO mg blower when bonnet temperature rises or fails. When controls as listed in Combination B-lX below are used, blower sw.ich is included m control equipment.
e-i*
Catalogue Page S59
Thermostatically Controlled
MH No. T-81 -A P'am Thermostat. MH No LA-tOt-A Blower and Limit Switch (Furnacestatl. MH No M-87-A Damper Motor with Transformer.
No 933 Accessories iChain, S-Hooks and Pulleys'.
e-5i
Same as above exceot with substitution of MH No. T-847-A Chronotherm lor No T-81-A Plain Thermostat.
OPTIONAL THERMOSTATS
OPTIONAL THERMOSTAT --Description
Extra* T rade Prices
For Use only with
Unit
Control Combi nation No
4 8 *0 J 8 10
8 10
4-0 20 4S7 83
Replaces
411-CDN Day-Nighi Heat Compensated Thermostat AND 772 Tem-Ciock
4'7 63
SHAWNEE SENECA WYANDOTTE MOHAWK
CHIPPEWA
G-l A-1 A-t or A-4 A-1 or A-6
A-16, A-16E. A-1 7
T-109-A Oa-Nite Thermostat (Manually Set)
1 | | 4 9 08
SHAWNEE IsENECA and \
(WYANDOTTE)
G-3 A-3
T-M7-A Night and Day Electric Clock Thermostat (Chronotherm)
Si 7 63 jMOHAWK
A-8 or A-9
T-801-A Time-O-Stat
T-847-A Night and Day Electric Clock Thermostat (Chronotherm)
$ 5 93 417 63
1SAGINAW
; SHAWNEE :SENECA and \
(WYANDOTTE) . MOHAWK and, , CHIPPEWA j
E G-2
A-2
A-7
These Extras to be added to Trade Prices of Units Do not apply if ordered separately.
411-CH Plain Thermostat
T-1 1-A Plam Thermostat
T-8I-A Plam Thermostat
AUTOMATIC NIGHT TURN DOWN ASSEMBLY
For Use only wth
Trade
No.
Description
Price
Unit
Control Comb1*
nation No
411-TD Night Tgrn Oown
assembly AND 772 Tem-Clock
Used to convert existing
411-CH P'a,n Thermostat to automatic Day-Night operation
4<8 08
SHAWNEE SENECA
W YANOOTTE MOHAWK
CHIPPEWA
SE-3
20
G-l A-t
A-1 or A-4
A-1 or A-6
A1 6. A-I6E. A-1 7