Document Z4zZrVOnLXBybGerD7q7gEv8J

More TECHNICAL BRIEFS. ~ " ** "fw'Tjj The first plant to operate on Bunker C was designed /or locomotive use. Jt was operated on stationary lest at the factory in Schenectady and on the test track in Erie for approximately 800 hours, during which more than 250,000 gallons of Bunker C were burned. Dur ing factory test snd after 492 hours of fired time, the first stage turbine nostle was oxidised to such a point it required replacement. The no-ale was inspected a number of times during the course of the test, and no oxidation was apparent for the first 390 hours. At the end of the 492-hour period, however, the condi tion of the noale showed definite attack. Shortly after the failure by corrosion of the first locomotive noule during factory ..test, a program of laboratory investigation* was started to learn more about the nature of oil ash corrosion and things which might be done to pre vent it. This program has continued from that time forward and is still being actively pursued. Two basic tools which were developed ond which ore being used in the study are the so-called cruci ble testa and the small-burner tests. The results of some of the work on crucible tests and the amall-burner tests hove been reported in a paper presented to the ASME in December 19S2. The crucible test measures the rate of cor rosion of a small metallic specimen enpoaed to synthetic oil ashes in a porcelain crucible which is maintained at testing temperature for 20 hours In o well-ventilated air-atmosphere furnace. The small-burner lest measures the cor rosion effect of actual combustion gases on a small sample. Over 5,000 such testa have been made to explore the effect of various corrod ing agents found in lypicat oil ashes, the resistance of different alloys to these corroding agents, and the effect of a wide range of additive materials which might be considered for use in treating fuel oils. Of all (he alloys tested thus far, olloys of iron with a relatively high percentage of chromium are the most resistant to corrosion. The best range oC these chromium-iron alloys appears to lie between 27 and 50% chromium, the best of the series being in the neighbor hood of 40% chromium. The effect of chromium over the entire range from 27 to 50% is not strongly marked, but below 25% the corrosion resistance de crease* sharply as the chromium de creases. Because alloys containing more than 28% chromium at present are dif ficult to produce, and because alloys containing less than 25% are poor In corrosion resistance, we have done moat of our testing ond researoh work on a 28% chrome-alloy and are now using this material in many of the first-stage nozzles. The straight 28% chromes are too weak at high temperatures to be satisfactory for many applications, but there is evidence that modified alloys of this type can be made which will be stronger and still have good corrosion resistance. It is not expected that they will be strong enough for highly stressed parts such as buckets. They will hove sufficient corrosion resistance to give satisfactory operating life with many untreated fuels. TO OBTAIN COMPLETE TEXT Material far then abstracts comes from the following sources unless otherwise slated. Order complete paper from sources, not Poweb, American Power Conference, annua/ meeting, Sherman Hotel, Chicago, III., Mar 24-27, f953. Identified by initials APC and ob tainable in proceedings printed and distributed by R A Buden hohet, chairman, Illinois Insti tute of Technology, 3300 Federal St, Chicago 16, lit. $6DO. American Society of Mechani cal Engineers, spring meeting, Deschler WaUiek Hotel. Colum bus, Ohio, April 28-30, I9S3. Identified by initials ASME and obtainable through ASME, 29 IF 39th St, Hew York 18, H. Y. It has. therefore, been concluded llmt in. addition to using the best alloys at hand, some method is also needed to treat gas turbine fuels--either to re move the corrosive agents or (o intro duce additives which react with the cor rosive ash constituents and render them htrcnleu. Data obtained from the cru cible tests to date indicate that vanadium pentoxide and sodium sulfate are the two most corrosive agents found in ap preciable quantities in any of the oil ashes we have examined, so much of our work has been directed toward finding methods ol reducing corrosion by these two materials. For inhibiting corrosion by vanadium pentoxide, compounds of calcium, magnesium, strontium, barium or nickel all appear to be good. Some of these have been suggested by pre vious investigators in this field. The fact that nickel serves as an inhibitor for vanadium corrosion is probably con- isiet'l with the fact that we have r: practically all high-nickel lloy$ 2$ poor in resistance to vanadium sion. It may bo postulated ibai vonadium has a high affinity f0r so ihm when the latter is im * as an additive it tie* up with v and prevents further corrosion; whejiL, when it is present in any alloy exp^j to vanadium, in certain tempersifrunges at least, the nickel u stUcktS' It has also been found that tuifote and vanadium pentoxide to extent inhibit one another, and sotj]^ containing oil relatively free from iu, dium will have a more corrosive than one containing the same ente^ of sodium and approximately thief times as much by weight ol vanadhi^ as sodium. In evety case when s ^ able amount of a calcium compouiui is added to a mixture of vanadium pentoxide and sodium sulphate in shica the weight of tedium present is less than 0.3 that of the vanadium, a very loir weight loss is ohtalned. Curves, in paper, show the percentage weijh'i loss of the crucible specimen, plotted* on a parabolic scale, versus the ratio' of vonadium pentoxide to the sura ofthe weights of the sodium sulphate pin* the vanadium pentoxide, on a lines scale. The simplified synthetic ash rep resented by the abscissa covers rsa|^ in composition from pure sodium sot; photo on the aero end to pure vanadium pentoxide on the 100% end of the scale: As can be seen, the minimum corrosion, rate occurs in the high vanadium oxidshalf of the ash scale whan calclura-is, added to the mixture. Results such these are the basis of a fuel specification' proposed in Aucust 1951, the essential; feature* of which are given in Table !' APC griper, no dumber. Fuels and Firing 3,000,000 kw Operating Uparients, with Modavn tahtt. By Otto de Lot-ensi, Combustion Engineering, Inc. Between January 1, 1945 and January 1, 1953 a total of 221 units having total, rated electrical capability of 27,* 582,000 kw, in sixes ranging from 40,000 _ to 250,000 kw, were on order, under ; construction, or in operation. Of lh>* . number 105 units, totaling 14,475,000 kw, wore ordered between March 1. . 1951, and January 1, 1953. The sum mary given by the author, in addition to showing size distribution of these'*; units, also provides throttle pressing n and primary steam temperatures. (Continued on page 222) 150 HEADER SERVICE SECTION powm ? we combat corrosion and searing arcs tla most industrial plants, metal-cisd switchgear is uadcr constant attack--inside and out. To pro ject against the effects of arcing, Westinghouse Lines arc chutes with a true ceramic containing high percentage of zircon, which bos the * highest mefring point of soy known material. Additional Important factors in chute life tbat'maintcnance men appreciate: Westinghouse chutes will not absorb moisture, have dielectric properties comparable to porcelain. This switchgeat employs the most effective method of arc extinction io use today. The arc is extinguished in split seconds end it is on the main contacts for only a fraction of this time. Result: less contact burning, less chute wear, less shock to the whole unit. fionderiting^ best proetieol surface protection The best practical metal surface protection that we know of for switchgear is Bonderiiing. We Booderixe our metal enclosures after they're assembled so that every nook and cranny gets the full five-dip treatment. Then the enclosures are painted twice and the paint sticks as though it is pInarWi oefstthineghmoeutasel. outdoor switchgear there's no worry about corrosion on the undersurfaces, either. After assembly, we spray (hem with a heavy layer of tubbecued coating. When you're planning switchgear installa tions, call in WeJtinghouse. And write now for your copy of booklet B-5306. VPestingbouse Electric Corp,, P. O. Box B6B, Pittsburgh 30, Pa. I ISoastu: WTEMSER 1453 you CAN B6SURE...'P'* "VVbstinghouse 151