Document Z4nbbLkr9ML1arLGG92Xp2MnO
Hr. J. R. Savage - General Office
June 8, 1970 FCB Losses To Atmosphere
<_-Mrr~'w. B. Papageorge ' Mr. H.S. Bergen
Messrs. B.W. Corlew H.L. Williams F. Macdonald
WOK Plant Anniston Plant Wewport
The attached memo from Bill Papageorge points out an area for study which has not been previously emphasised. While the nature of the process and the product seem to preclude substantial losses to the atmosphere, we should not be complacent.
One of the first questions from semi-knowledgeable
them how sure we are, if we have no data.
Sampling seems indicated at the exhaust of the scrubbed air from blowing, and from ventilating hoods at drumming statins, still bottoms draw-off, etc. Calculated values for storage tank vents assuming saturation at the storage or transfer temperature will probably suffice. If the calculated values exceed a pound or two per day, sampling is in order.
When the first set of data is complete, please propose such reduction targets as seem needed, and a frequency for future control sampling. I suggest a target date for this first phase (initial samples, target and sample frequency setting ) of September 15, 1970.
md attachments: 2
J. R. Savage
-**n
DSW 175777
WATER PCB-SD0000051863
Monsanto
# .*.**c ioc*i
Jl CT
* % i Ml SCi TO
W. E. PAPAOEORGE - ST. LOUIS______________________________________
JUNE 1, 1970 PCs LOSSES TO ATMOSPHERE
J> R- SAVAGE~
" K. G. P. G. R. P. J.
S. BERG2.''
BRATS CH - KRUKXRICH 3. HCDJES L. JESSES - ANNISTON E. KELLER MACDONALD - NEWPORT E. SPRINGGATE
In evaluating our perform.ar.ee in the control of PCS'3 to the environment from our manufacturing facilities, v;e should not neglect to consider losses so the atmosphere through jet exhausts, vents, stacks, etc.
Bob Keller's group has developed procedures for t:.i Ting and s utanrqu'errft mari'tystbs "-dE -gprs 'Yara-, vapor) samples.
.1 recognise shat accurate determination of the
.
losses to the atmosphere is difficult, but I believe
a critical study of each facility considering flow
rates, frequencies and concentrations could result
in a pounds per day loss figure which could serve
as a useful guide.
,
Will you have each plant develop a program for auditing the present situation, mohitoring on a planned basis and taking corrective action to achieve targeted losses to the atmosphere?
t'C'-'/O CPcyC-- W. B. PAPAGEORGE
DSW 175778
WATER PCB-SD0000051864
r--------
rs DSW 175779
n <-*^yjdi1
r
ft, LJ3>, Sr<D O c,-n^'' X-3~'-'--
`rOL*3
rD_ /0` -OC.\" r Or t.Jy' ^Ji^ j.
CJs-l- X^V"/' '
s3O^-
-u
A-*. y;
i ^ i_
cD /
.
`-^ 'V"*~
v-'- i s-o c.
lo;fco = zk2o .c-r
->.4lT
0,3
.
z.^ -eo X-t" 3^
^3C<
fl,3V
' *--------- x* ZS* -r *
313\ nio+0l,
= ,rrr n
(k-u--p --Cj t/.p
Poy'p'
'hklZE- * 'u~l 3 /
s-*i
ic i. in
- 32, "Z6 /4
(JJr^
-^C_ *--" -'V'-O
a,--c ^
la CX^ytpLc-^ VJ^.c^~h^
r /y'
^ ( f^LU^. S.T, . a k^yT\ .
[_oL
, fc-* , _
"\
.n Uc^-
I Jf
cG^^-L
-!- - -
^ H 'Lt-fl'.-U} = / 33oco ^^33
t3 l'l-^'3 o^'--Ir 3y~a^y3-i
-/ /
.'" / J*___
;
`- /<.*- -r.'Xvi^
jy-y^-U
WATER PCB-SD0000051865
MCL H3 95?
1
vy -
PRO CjR-E'S"S REPORT
TECHNICAL SERVICES DEPARTMENT SQ. 10651
JOB NO> REPORT:DATE:-
27/7139/2392 No. 2 15.10.70
Distribution:*
D.B. Shearn/F. Macdonald
D.S. Cameron
N. Bodger * H. Disley *
H.A. Vodden * W. Papageorge
D. Hewitt
E. Wheeler
A.C. Nethercott
R. Keller
*
A.F. Regan / D.W.H. Casey *
D. Danna
R. Thomas *
R. Williams *
B.J. Williams
* To receive details section
Brussels Ruabon St. Louis G.O.
ft
tl
If * '
n
. =: vm.
TITLE:
Environmental Contamination by PCB (Atmospheric)
' contamination.
>J-aat^aianpspheres for PCB
PERSONNEL:
R. Thomas (A.C. Nethercott)
SUMMARY:
An absorption train apparatus was set up. The plant atmospheres were sampled and the PCB content was ascertained. The results obtained are quoted below. All but a few of the locations have been sampled to date and more samples will be taken so that more meaningful results are obtained.
in air.
Results varied from practically nil to 0.94 mg/m^ PCB .
FUTURE WORK
'
To complete the sampling programme and finalise any recommendations.
d TbjrrrL.(U> R. THOMAS
DSW 175780
WATER PCB-SD0000051866
Results Area
-
2 PCB mg/m^ air Comments
Drumming
:
Chlorination (Ground floor)
0.38
0.59 0.13
Indoors. Two roller doors open
Enclosed space, large roller door open
II II H
If II ff
Santolube 900
0.23
Indoors. Normal process conditions
4NDPA (Expansion Tank) Prac. Nil
Outdoors. Variable W - E wind (still) Outdoors. W - E wind (Wet and Windy)
Aroclor control 0.28 room
Indoors
Chlorination (First floor)
Airblowing room
0.12
0.19 0.12 0.39
Fourth side open. Chlorinators were shut down.
Chlorinators operating
""
Indoors. Normal process conditions.
DSW 175781
WATER PCB-SD0000051867
Recommendations
3
1. That these determinations be repeated on a regular basis to
be decided so that trends can be studied and controls*\ CCset.
.2 That the apparatus be assembled in a permanent portable
form for use when required.
3. That any future modifications or recommendations be incorporated in the apparatus.
4. That all storage vessels containing finished product Aroclor be held at as low a temperature as is possible for subsequent handling.
5. That all storage vessels containing finished product Aroclor be fitted with nitrogen fed conservation vents.
.6 That emission of Aroclor from venting systems on storage vessels
be cut to the very minimum by the use of some suitably designed vent gas cooling/condensing system.
7. That the ventilating systems in the plant office, changing room and control rooms be upgraded so that these atmospheres are continuously purged with fresh clean air.
DSW 175782
WATER PCB-SD0000051868
DETAILS
4
The apparatus consists of two absorbers in series, the first one being charged with 75 mis of toluene. The second one is empty and acts as a catch vessel for any entrained toluene. An indicating flowmeter (rotameter) is next in line with a water filled manometer feed into the line. An indicating dry gas meter is next in line and this is followed by a laboratory vacuum pump which is fitted with an air-bleed valve. Where the vacuum pump cannot be used, as the electric motor is not flameproof, a laboratory size water pump is used. This latter is not as convenient to use and needs more attention.
The dry air meter used can only be used to a vacuum of 10 ins water gauge so pressure drop through the system must be minimal. This is why only two absorbers are used.
The absorbers are thoroughly cleaned before each run using the procedure recommended by R. Keller. Air flow through the apparatus is at % - 1 litre per minute and about 60 litres of air is drawn through the apparatus for each run.
-4fetes -jfeafieiSBse -4sb '^sm/eSmasssS. jar after measurement of final volume. This sample is taken to the Analytical laboratory where it is reduced in volume to about 3 mis.
from 60 - 70 mis. The concentrated sample is fed into the chromatograph and the PCB content is determined.
The temperature of the air being sampled is measured, the manometer is read and a mean reading is established, the barometric pressure is obtained and the air meter is read to find the volume of air used.
The absorbers are removed and sealed for removal from the area, but the rest of the apparatus is purged with air to remove any entrained toluene.
The volume of air sampled is corrected to 25C and 760 mms of mercury pressure.
A PCB result is obtained from the laboratory and this result is converted to give milligrams of PCB per cubic metre of air. The
range for maximum allowable concentration (M.A.C.) is 0.5 mg/m3 - 1.0 mg/m3 for lower to higher aroclors.
Results obtained to date range from practically nil to 0.94 mg/m^ which is satisfactory.
DSW 175783
WATER PCB-SD0000051869
COMMENTS
5
These determinations are not absolute and there are limitations in interpretation of the results. At best the results can only compare measured concentration from sample point to sample point.
Every effort was made to standardise the sampling procedure but .for certain locations a different method was used to suck air through'the apparatus.
Sampling atmospheres is an inaccurate procedure as things like wind direction, weather conditions and local unexpected contamination can have bearing on the results obtained. Conditions at two different sampling times will nearly always be different.
Two absorbers in series were used, the first was charged with Toluene and the second was used as a catch vessel for any entrained toluene. Despite this catch vessel, loss of toluene was experienced through the apparatus. This loss was allowed for on each result calculation.
.As ,,ajLr Jiad to ,be .sucked through the apparatus the absorption took
place at less than 'atmospheric pressure and this of course necessi'tateS measured volume correction to atmospheric (standard) pressure. Each volume was corrected to 760 mms. Hg pressure and 25C.
The variables determining the degree and extent of constituent distribution are stability of the atmosphere, wind speed and direction,
precipitation, topography, emission and formation rates and physical and chemical characteristics of the constituents.
DSW 175784
WATER PCB-SD0000051870
6
Equipment used and operating data
Electron Capture Gas Chromatographic Procedure
Instrument: Detector:
Hewlett - Packard 402
Gas Chromatograph
High temperature N^_63 Electron capture cell
6 mm x 6' Glass column, 4% O.V. 225 on 80/100 mesh
Chromosorb W, H.P.
Column Temperature:
170C
Detector Temperature:
260C
Injection Port Temperature: 200C
Pulse:
150
Flow rates:
40 mls/min Argon/Methane 80 mls/min Helium
Range:
10
Alternation:
4
Chartspeed:
0.25"/min.
RT/EM 15.10.70
DSW 175785
WATER PCB-SD0000051871
W. B. PAPAGEORGE - ST. LOUIS JUNE 1, 1970 PCB LOSSES TO ATMOSPHERE
J. R. SAVAGE
H. S. BERGEN G. BRATSCH - KHOMMRICH P. B. HODGES G. L. JESSEE - ANNISTON R. E. KELLER P. MACDONALD - NEWPORT J. E. SPRINGGATE
In evaluating our performance in the control of PCB's to the environment from our manufacturing facilities, we should not neglect to consider losses to the atmosphere through Jet exhausts, vents, stacks, etc.
Bob Keller's group has developed procedures for the sampling and subsequent analysis of gas (air, vapor) samples.
I recognize that accurate determination of the losses to the atmosphere is difficult, but I believe a critical study of each facility considering flow rates, frequencies and concentrations could result in a pounds per day loss figure which could serve as a useful guide.
Will you have each plant develop a program for auditing the present situation, monitoring on a planned basis and taking corrective action to achieve targeted losses to the atmosphere?
W. B. PAPAGEORGE
SW 175786
WATER PCB-SD0000051872