Document Z4nbbLkr9ML1arLGG92Xp2MnO

Hr. J. R. Savage - General Office June 8, 1970 FCB Losses To Atmosphere <_-Mrr~'w. B. Papageorge ' Mr. H.S. Bergen Messrs. B.W. Corlew H.L. Williams F. Macdonald WOK Plant Anniston Plant Wewport The attached memo from Bill Papageorge points out an area for study which has not been previously emphasised. While the nature of the process and the product seem to preclude substantial losses to the atmosphere, we should not be complacent. One of the first questions from semi-knowledgeable them how sure we are, if we have no data. Sampling seems indicated at the exhaust of the scrubbed air from blowing, and from ventilating hoods at drumming statins, still bottoms draw-off, etc. Calculated values for storage tank vents assuming saturation at the storage or transfer temperature will probably suffice. If the calculated values exceed a pound or two per day, sampling is in order. When the first set of data is complete, please propose such reduction targets as seem needed, and a frequency for future control sampling. I suggest a target date for this first phase (initial samples, target and sample frequency setting ) of September 15, 1970. md attachments: 2 J. R. Savage -**n DSW 175777 WATER PCB-SD0000051863 Monsanto # .*.**c ioc*i Jl CT * % i Ml SCi TO W. E. PAPAOEORGE - ST. LOUIS______________________________________ JUNE 1, 1970 PCs LOSSES TO ATMOSPHERE J> R- SAVAGE~ " K. G. P. G. R. P. J. S. BERG2.'' BRATS CH - KRUKXRICH 3. HCDJES L. JESSES - ANNISTON E. KELLER MACDONALD - NEWPORT E. SPRINGGATE In evaluating our perform.ar.ee in the control of PCS'3 to the environment from our manufacturing facilities, v;e should not neglect to consider losses so the atmosphere through jet exhausts, vents, stacks, etc. Bob Keller's group has developed procedures for t:.i Ting and s utanrqu'errft mari'tystbs "-dE -gprs 'Yara-, vapor) samples. .1 recognise shat accurate determination of the . losses to the atmosphere is difficult, but I believe a critical study of each facility considering flow rates, frequencies and concentrations could result in a pounds per day loss figure which could serve as a useful guide. , Will you have each plant develop a program for auditing the present situation, mohitoring on a planned basis and taking corrective action to achieve targeted losses to the atmosphere? t'C'-'/O CPcyC-- W. B. PAPAGEORGE DSW 175778 WATER PCB-SD0000051864 r-------- rs DSW 175779 n <-*^yjdi1 r ft, LJ3>, Sr<D O c,-n^'' X-3~'-'-- `rOL*3 rD_ /0` -OC.\" r Or t.Jy' ^Ji^ j. CJs-l- X^V"/' ' s3O^- -u A-*. y; i ^ i_ cD / . `-^ 'V"*~ v-'- i s-o c. lo;fco = zk2o .c-r ->.4lT 0,3 . z.^ -eo X-t" 3^ ^3C< fl,3V ' *--------- x* ZS* -r * 313\ nio+0l, = ,rrr n (k-u--p --Cj t/.p Poy'p' 'hklZE- * 'u~l 3 / s-*i ic i. in - 32, "Z6 /4 (JJr^ -^C_ *--" -'V'-O a,--c ^ la CX^ytpLc-^ VJ^.c^~h^ r /y' ^ ( f^LU^. S.T, . a k^yT\ . [_oL , fc-* , _ "\ .n Uc^- I Jf cG^^-L -!- - - ^ H 'Lt-fl'.-U} = / 33oco ^^33 t3 l'l-^'3 o^'--Ir 3y~a^y3-i -/ / .'" / J*___ ; `- /<.*- -r.'Xvi^ jy-y^-U WATER PCB-SD0000051865 MCL H3 95? 1 vy - PRO CjR-E'S"S REPORT TECHNICAL SERVICES DEPARTMENT SQ. 10651 JOB NO> REPORT:DATE:- 27/7139/2392 No. 2 15.10.70 Distribution:* D.B. Shearn/F. Macdonald D.S. Cameron N. Bodger * H. Disley * H.A. Vodden * W. Papageorge D. Hewitt E. Wheeler A.C. Nethercott R. Keller * A.F. Regan / D.W.H. Casey * D. Danna R. Thomas * R. Williams * B.J. Williams * To receive details section Brussels Ruabon St. Louis G.O. ft tl If * ' n . =: vm. TITLE: Environmental Contamination by PCB (Atmospheric) ' contamination. >J-aat^aianpspheres for PCB PERSONNEL: R. Thomas (A.C. Nethercott) SUMMARY: An absorption train apparatus was set up. The plant atmospheres were sampled and the PCB content was ascertained. The results obtained are quoted below. All but a few of the locations have been sampled to date and more samples will be taken so that more meaningful results are obtained. in air. Results varied from practically nil to 0.94 mg/m^ PCB . FUTURE WORK ' To complete the sampling programme and finalise any recommendations. d TbjrrrL.(U> R. THOMAS DSW 175780 WATER PCB-SD0000051866 Results Area - 2 PCB mg/m^ air Comments Drumming : Chlorination (Ground floor) 0.38 0.59 0.13 Indoors. Two roller doors open Enclosed space, large roller door open II II H If II ff Santolube 900 0.23 Indoors. Normal process conditions 4NDPA (Expansion Tank) Prac. Nil Outdoors. Variable W - E wind (still) Outdoors. W - E wind (Wet and Windy) Aroclor control 0.28 room Indoors Chlorination (First floor) Airblowing room 0.12 0.19 0.12 0.39 Fourth side open. Chlorinators were shut down. Chlorinators operating "" Indoors. Normal process conditions. DSW 175781 WATER PCB-SD0000051867 Recommendations 3 1. That these determinations be repeated on a regular basis to be decided so that trends can be studied and controls*\ CCset. .2 That the apparatus be assembled in a permanent portable form for use when required. 3. That any future modifications or recommendations be incorporated in the apparatus. 4. That all storage vessels containing finished product Aroclor be held at as low a temperature as is possible for subsequent handling. 5. That all storage vessels containing finished product Aroclor be fitted with nitrogen fed conservation vents. .6 That emission of Aroclor from venting systems on storage vessels be cut to the very minimum by the use of some suitably designed vent gas cooling/condensing system. 7. That the ventilating systems in the plant office, changing room and control rooms be upgraded so that these atmospheres are continuously purged with fresh clean air. DSW 175782 WATER PCB-SD0000051868 DETAILS 4 The apparatus consists of two absorbers in series, the first one being charged with 75 mis of toluene. The second one is empty and acts as a catch vessel for any entrained toluene. An indicating flowmeter (rotameter) is next in line with a water filled manometer feed into the line. An indicating dry gas meter is next in line and this is followed by a laboratory vacuum pump which is fitted with an air-bleed valve. Where the vacuum pump cannot be used, as the electric motor is not flameproof, a laboratory size water pump is used. This latter is not as convenient to use and needs more attention. The dry air meter used can only be used to a vacuum of 10 ins water gauge so pressure drop through the system must be minimal. This is why only two absorbers are used. The absorbers are thoroughly cleaned before each run using the procedure recommended by R. Keller. Air flow through the apparatus is at % - 1 litre per minute and about 60 litres of air is drawn through the apparatus for each run. -4fetes -jfeafieiSBse -4sb '^sm/eSmasssS. jar after measurement of final volume. This sample is taken to the Analytical laboratory where it is reduced in volume to about 3 mis. from 60 - 70 mis. The concentrated sample is fed into the chromatograph and the PCB content is determined. The temperature of the air being sampled is measured, the manometer is read and a mean reading is established, the barometric pressure is obtained and the air meter is read to find the volume of air used. The absorbers are removed and sealed for removal from the area, but the rest of the apparatus is purged with air to remove any entrained toluene. The volume of air sampled is corrected to 25C and 760 mms of mercury pressure. A PCB result is obtained from the laboratory and this result is converted to give milligrams of PCB per cubic metre of air. The range for maximum allowable concentration (M.A.C.) is 0.5 mg/m3 - 1.0 mg/m3 for lower to higher aroclors. Results obtained to date range from practically nil to 0.94 mg/m^ which is satisfactory. DSW 175783 WATER PCB-SD0000051869 COMMENTS 5 These determinations are not absolute and there are limitations in interpretation of the results. At best the results can only compare measured concentration from sample point to sample point. Every effort was made to standardise the sampling procedure but .for certain locations a different method was used to suck air through'the apparatus. Sampling atmospheres is an inaccurate procedure as things like wind direction, weather conditions and local unexpected contamination can have bearing on the results obtained. Conditions at two different sampling times will nearly always be different. Two absorbers in series were used, the first was charged with Toluene and the second was used as a catch vessel for any entrained toluene. Despite this catch vessel, loss of toluene was experienced through the apparatus. This loss was allowed for on each result calculation. .As ,,ajLr Jiad to ,be .sucked through the apparatus the absorption took place at less than 'atmospheric pressure and this of course necessi'tateS measured volume correction to atmospheric (standard) pressure. Each volume was corrected to 760 mms. Hg pressure and 25C. The variables determining the degree and extent of constituent distribution are stability of the atmosphere, wind speed and direction, precipitation, topography, emission and formation rates and physical and chemical characteristics of the constituents. DSW 175784 WATER PCB-SD0000051870 6 Equipment used and operating data Electron Capture Gas Chromatographic Procedure Instrument: Detector: Hewlett - Packard 402 Gas Chromatograph High temperature N^_63 Electron capture cell 6 mm x 6' Glass column, 4% O.V. 225 on 80/100 mesh Chromosorb W, H.P. Column Temperature: 170C Detector Temperature: 260C Injection Port Temperature: 200C Pulse: 150 Flow rates: 40 mls/min Argon/Methane 80 mls/min Helium Range: 10 Alternation: 4 Chartspeed: 0.25"/min. RT/EM 15.10.70 DSW 175785 WATER PCB-SD0000051871 W. B. PAPAGEORGE - ST. LOUIS JUNE 1, 1970 PCB LOSSES TO ATMOSPHERE J. R. SAVAGE H. S. BERGEN G. BRATSCH - KHOMMRICH P. B. HODGES G. L. JESSEE - ANNISTON R. E. KELLER P. MACDONALD - NEWPORT J. E. SPRINGGATE In evaluating our performance in the control of PCB's to the environment from our manufacturing facilities, we should not neglect to consider losses to the atmosphere through Jet exhausts, vents, stacks, etc. Bob Keller's group has developed procedures for the sampling and subsequent analysis of gas (air, vapor) samples. I recognize that accurate determination of the losses to the atmosphere is difficult, but I believe a critical study of each facility considering flow rates, frequencies and concentrations could result in a pounds per day loss figure which could serve as a useful guide. Will you have each plant develop a program for auditing the present situation, monitoring on a planned basis and taking corrective action to achieve targeted losses to the atmosphere? W. B. PAPAGEORGE SW 175786 WATER PCB-SD0000051872