Know Your
-Hydraulic
Fire Tests
sprinkler systems can be installed.
: But the simplest and surest way
' to protect against heat transfer
oil fires is to stop them before
Defining fire resistance in precise terms and numbers is extremely difficult and is best done in terms of expected fire hazards. Assessment of hazards should include consideration of all three components re quired for combustion--fuel, oxidizer, and source of ignition--as well as ways in which the three can combine into a fire. Simulative tests are considered most meaningful in assessing fire resistance. Since
(they start--with fire-resistant
iTherminol(R) FR fluids. Therminol(R)
FR will not support combustion.
When emergencies occur, Therminol(R)
FR minimizes the danger of local fires t
that can injure operators, spread to
other locations, flash back to the
I
break, or destroy equipment. By
exposure conditions and sources of ignition vary their very chemical nature, Therminol(R)
widely, multiple tests are usually used in fire re FR fluids are fire-resistant--from
sistance evaluation. Test conditions should reflect two basic parameters of fire resistance--the ability to resist, ignition and to prevent propagation of flame away from the source of ignition.
An ounce of prevention can be worth the cost of a plant or even the life of a worker. Hazardous plant operations can be isolated--fire walls can be built;
start-up through every hour of operation. Know your system's fire hazards
. . .know the tests and performance levels which are essential for assessing the fire resistance of any heat transfer fluid. The most widely accepted tests for measuring
fire resistance are presented on the .
following pages.
0^ 31 *>bb
TOWOLDMON0032062 WATER_PCB-00016531
HIGH TEMPERATURE HIGH PRESSURE SPRAY TEST
Procedure: AMS 3150C. The fluid, at 1000 psi, is sprayed through a 0.0145 in. diameter orifice pass ing through the flame of an oxyacetylene torch with a No. 1 Purox tip held perpendicular to the fluid stream. Attempts are made to ignite the fluid stream at varying distances from the orifice.
Performance: This test simulates the hazard of a spray from a hyflmulie fluid leak coming in contact with a high temperature flame ignition source. Per formance is evaluated based on the ease of ignition, and the distance the flame is carried from the source of ignition, if ignition occurs.
''
I
TOWOLDMON0032063
WATER_PCB-00016532
HOT MANIFOLD TEST
Procedure: AMS 3T50C. Ten milliliters of fluid are dripped in 40 spdonds onto a stainless steel simu lated hot mamfold held at 1300F. (704C.). Flash ing or burning on contact with the tube, and carrying ofmame to fluid collected in the bottom of the shield/tube holder are observed.
Perfornfance: This test simulates a hydraulic fluid leak .coming into contact with a hot surface. The hydraulic fluid should show only intermittent flash ing or burning when dripped on the 1300F. (704 C.) manifold and should not carry flame to the bottom of the shield.
LOW PRESSURE SPRAY TEST
Procedure: AMS 3150C. The fluid is sprayed from a Binks Thor No. 7 paint spray gun (0.070 inch diameter orifice, 40 psi air) in bursts over the source of ignition, burning oil-soaked waste. Any increase or decrease in the flame caused by the fluid mist is observed.
Performance: This test is not commonly used, but is designed tg simulate a line break spraying onto an open source of ignition. Criteria of performance is to observe for flame increase, no change, or de crease in intensity.
i
i i
0*31668
TOWOLDMON0032064 WATER_PCB-00016533
(2)
AUTOIGNITION TEMPERATURE (AIT)
Procedure: ASTM D 2155-66. A fluid sample is in jected via hypodermic syringe into a heated glass flask. Autoignition is determined by appearance of visible flame.
Performance: This test measures autogenous igni tion temperature in glass in air at one atmosphere pressure. Test conditions are critical and applica tion of data to metal systems of irregular design is difficult.
FLASH AND FIRE POINTS
Procedure: ASTM D 92-66. The fluid is heated in an open test cup at a constant rate. A small test flame is passed over the surface at specified tem perature intervals. The lowest temperature at which the vapors above the surface ignite is the flash point. The fire point is the temperature at which the fluid ignites and burns for at least five seconds.
Performance: This test measures the ignitability of heated fluid. Flash and fire test results are some times misleading since they are so directly related to the chemical nature of the product being tested.
0* 31 669
TOWOLDMON0032065 WATER_PCB-00016534
page 4
\'
Heads The Teste Described Her. . .
Copy! show some of the rigorous methods used to determlnedflre resistance. Tests like these have established Thermlnol FR fluids as the only heat transfer fluids rated for fire resistance by Underwriters' Laboratory, Inc, and approved by Factory Mutual.
x
Thermlnol FR fluids are chemically synthesized from materials that resist burning. Other fluids, such as the glycols, petroleum oils and liquid/vapor phase fluids will burn and support
combustion.
If you'd like to find out more about Thermlnol FR fluids, see the 16 mm full-color moive, "The House That Jack Built".
You can see for yourself--and demonstrate to others--
"Tests for fire resistance in Thermlnol FR fluids
Typical Thermlnol installations
A whole new concept in heat system design
To reoeive a copy for showing, write or call the nearest Monsanto office on the following page.
O/.31S70
TOWOLDMON0032066 WATER_PCB-00016535
___ The Tests___ Described Here...
show some of the rigorous methods
of determining fire resistance. Tests
like these have established Therminol(r)
FR fluids as the only heat transfer fluids rated for fire resistance by
Underwriters' Laboratory, Inc. and
approved by Factory Mutual.
Therrninol(R) FR fluids are
chemically synthesized from materials
that resist burning. Other fluids,
such as the glycols, petroleum oils
and mipgxyjjh vapor/liquid-phase
fluids, will burni and support
combustion.
^
If you'd like to find out more about Therrninol(R) FR fluids, see the 16 mm full-color movie,
"THE HOUSE THAT JACK BUILT"
You can see for yourself-- and demonstrate to other
Tests showing fire-resistance of Therminol FR fluids.
Typical Therminol installations,
concept
A whole new
in heat
system design.
To receive a copy for showing, write: