Document Z4ebEmpwGZO9rnvzN3oDNwgRV

7h#6& mU Ck#uas6- ToH._^L^j3argon7 CalWrt PUT IT IN WRITING Subject Date Marchs, 1973 AIR MONTTORIttft - From J. T. Barr. Calvert City ) Take Action } For Your Approval ) For Your Comments ) As Requested MY MEMO OF mRCH 5, 1973 { ) For Your Info ( ) Discuss With Me ) File { ) Note & Return A copy of the paper on air monitoring of chlorinated compounds from the Dow Labs is attached. Following your instructions in your memo of February 21, 1973 to R. B. Cross, I attach to your copy a draft of a CE in the sum of $1,150 for the purchase of equipment of the type described in the attached paper. The exact equipment recommended is given in the attached table. I have suggested getting one complete unit equipped for respirable dust and lead analyses, plus two basic units which can be adapted by the Lab according to the attached paper to determine vinyl chloride exposures. I would foresee these latter two units being used throughout the plant to determine personnel exposures at given work positions, or being carried by a worker as is described in the Dow paper. There is every reason to believe that this technique would be extended to other organic vapors, such as methanol and vinyl acetate, which also have had maximum allowable limits prescribed for them by OSHA. JTB:si cc: R. R. Harvey T. W. Herbig J. D. Kraroer/Va: R. tf. McGinnis . M. H. Stermon ey Forge/122 AP00043318 1 AIR MONITORING EQUIPMENT RECOMMENDED 1 - C-115 Personnel Monitor Catalogue No. 3650-80 2 - C-115 Monitor Catalogue No. 3650-05 8 $250 2 - Rechargable Batteries Catalogue No. 3600-31 8 $47.80 2 - Battery Chargers Catalogue No. 3600-20 8 $32.50 1 - Box of 100 VM-1 Filters 2 - Lead Sampling Heads Catalogue No. 3600-310 0 $1.50 1 - Box of 100 Filters p> Catalogue No. 60194 Jr* 2 - Plastic Filter Holders Catalogue No. 3600-300 8 $1.25 # TOTAL * $ 345.00 500.00 95.60 65.00 23.00 ` 3.00 23.00 ________ 2.50 $1,057.10 j i AP00043319 I. SPECIFICATIONS FOR CHARCOAL TUBS PUMP The following performance requirement* must be met by the pump, regardless of design: ~ 1. The pump shall be adjustable to produce flow rates between SO cc/ain and 200 cc/nin through a charcoal tube. (See attachment A for drawing and dimensions of a charcoal tube.- Samples can be obtained from NIOSH upon request.) The maximum resistance of any given charcoal tube will be 2.S inches of water at a flow rate of 200 cc/min. `2, The pump shall be battery operated and shall be capable of operating for at- least .four hours without recharging or replacing the batteries. Rechargeable batteries shall be used and included with the pumps. 3. In size the pump shall not exceed any of the following dimensions:. * 1.25 inches in depth 2.SO inches in width 5.00 inehes in length it shell be designed to fit inside a shirt pocket. It shall not exceed 12 ounces in weight, including batteries. A means of attaching the pump to the pocket shall be provided. 4. The pump shall contain an indicating device, such as a stroke or re volution counter, which gives a number which can be converted to total volume of air sampled within ^ 5% accuracy. 5. The pump shall contain a built-in flow rate indicator. If this flow rate indicator does not indicate actual flow rate within +_ 5% accuracy, the unit shall have an additional external provision, such as a volt meter jack, to provide accurate flow rate setting and adjustment. 6. There shall be an .external tube to protect the glass charcoal tube from breakage and to protect the inlet so that only airborne contaminants may enter. 7. The unit shall be designed in such a way that the tube and tube holder may be attached to the worker in such a location that the sample will be collected from the worker's breathing zone. r * i * i i 'j AP00043320 SCHEDULE 3. Loading and adjustment features, such as the flow rate adjustment and on-off switch, shall be so designed as to limit opportunities, for de liberate or accidental tampering with the sampler while it is in'oper ation. 9. The pump shall be regulated so that the flow rate does not change more than 10% over a continuous 4-hour' period of operation although the battery is discharging. 10, The pump shall met U. S.1 Bureau of Mines,requirements for intrinsic safety. '. 11, Each pump unit shall be delivered with a removable plastic or leather pouch in which the pump may optionally be placed and attached by a belt clip to a worker's belt. , V AP00043321 1 amd CkmxecUt- PUT IT IN WRITING Date 8 April 1974 Charles McDonald - Calvert Snhiftrt Organic Vapor Reading at Emulsion From. D. J. Lawson - Calvert I ) Take Action ( ) For Your Approval ( ) For Your Comments ( ) As Requested Plant during 720-728 Production: (x) For Your info ( } Discuss With Me { ) File ( ) Note & Return Attached are the readings taken at the Emulsion Plant with the Century Organic Vapor Analyzer During A-720 and A-728 production. LOCATION Date ppm T ime Oreanl Bottom fLoor in corner by south door i Bottom f loor 1 ft. over monomer delay pump Bottom floor 10 ft. from pump over drain it Bottom floor halfway between pump & East fan Bottom loor at East Fan it it it it it Bottom f loor t West fai Bottom floor center of West wall 1st level of steps over monomer delay pump 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 1900 1030 1500 1500 2000 27 60 22 31 16 90 140 14 25 46 150 35 <10 14 16 60 21 12 15 14 35 30 18 16 17 60 45 12 18 21 200 300 <10 30 34 70 450 <10 22 28 AP00043322 1 Charles McDonald Page -2- SUBJECT: Organic Vapor Reading at Emulsion Plant during 720-728 Production. LOCATION Second floor over samp Le point n it IT ii ii TV IT it tr IT If 11 M ir M II II II ii Third floor at reactor by drain TT II H IT TT ii If tl it IT 11 9Y II It II M ii tr II Tl IT IT IT n Third floor a t topi steps IT II it ii 11 IT II it u . tv II 11 it i it 1 II It tl H 8 April 1974 Date 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 4/2/74 4/3/74 4/4/74 4/5/74 4/6/74 Time ppra Organ 1900 1030 1500 1500 2000 1900 1030 15P0 1500 2000 1900 1030 1500 1500 2000 45 90 10 18 19 140 45 40 15 15 22 35 40 15 15 DJL:kg cc: H M. Konrad J D. Kramer C & J. H. Smith Stermon . /" H J. Zorman - D . Laws on AP00043323