Document Z4dxzvGQEyQY7B4GpozzVvzMp

22762 Federal Register / Vol. 51, No. 119 / Friday. Jane 20, 1986 / Rules and Regulations (4) Training records. The employer shall maintain all employee training records for one 1 year beyond the last date of employment by that employer. (5) Availability, (i) The employer, upon written request, shall make all records required to be maintained by this section available to the Assistant Secretary and the Director for examination and copying. (ii) The employer, upon request, shall make any exposure records required by paragraphs (f) and (n) of this section available for examination and copying to affected employees, former employees, designated representatives, and the Assistant Secretary, in accordance with 29 CFR 1910.20(a)-(e) nnd (gMO(iii) The employer, upon requesl, shall tnuke employee medical records required by paragraphs (m) and (n| of this section available for examination and copying to the subject employee, anyone having the specific written consent of the subject employee, and the Assistant Secretary, in accordance with 20 CFR 1910.20. (ft) Transfer of records, (i) The employer shall comply with (he requirements concerning transfer of records set forth in 29 CFR 1910.20 (h). (ii) Whenever the employer ceases to do business and there is no successor employer to receive and retain the records for the prescribed period, the employer shall notify the Director at least 90 days prior to disposal and, upon request, transmit them to the Director. (o) Dates--(1) Effective date. This section shall become effective [insert date 30 days from publication in the Federal Register], The requirements of the asbestos standard issued in (une 1972 (37 FR 11318), as amended, and published in 29 CFR 1910.1001 (1985) remain in effect until compliance is achieved with the parallel provisions of this standard. (2) Start-up dates, (i) The requirements of paragraphs (c) through . (n) of this section, including the engineering controls specified in paragraph (g)(1) of this section, shall be complied with by [insert date 210 days from publication in the Federal Register). (p) Appendices, (i) Appendices A, C, D, and E to this section are incorporated as part of this section and the contents of these appendices are mandatory. (2) Appendices B, F, G, H, and I to this section are informational and are nipt intended to create any additional obligations not otherwise imposed or to detract from any existing obligations.. Appendix A to 192G.5A--OSHA Reference Method--Mandatory This mandatory appendix specifies the procedure for analyzing air samples for asbestos, tremolite. anthophyllite. and actinolite and specifies quality control procedures that must be implemented by laboratories performing the analysis. The sampling and analytical methods described below represent the elements of the available monitoring methods (such as the NiOSH 7400 method) which OSHA considers to be essential to achieve adequate employee exposure monitoring while allowing employers to use methods that are already established within their organizations. All employers who ore required to conduct air monitoring under paragraph (f) of the standard are required to utilize analytical laboratories that use this procedure. orn equivalent method, for collecting and analyzing samples. Sampling and Analytical Procedure 1. The sampling medium for air samples shall be mixed cellulose ester filter membranes. These shall be designated by the manufacturer as suitable for asbestos, tremolite, anthophyllite, and actinolite counting. See below for rejection of blanks. 2. The preferred collection device shall be the 25-mm diameter cassette with an openfaced 50-mm extension cowl. The 37-mm cassette may be used if necessary but only if written justification for the need to use the 37-mm Titter cassette accompanies the sample results in the employee's exposure monitoring record. 3. An air flow rate between 0.5 liter/min and 2.5 liters/min shall be selected for the 25/mm cassette. If the 37-mm cassette is used, an air flow rate between 1 liter/min and 2.5 iiters/min shat) be selected. 4. Where possible, a sufficient air volume for each air sample shall be collected to yield between 100 and 1.300 fibers per square millimeter on the membrane (liter. IT a filter darkens in appearance or if loose dust is seen on the filter, o second sample shall be started. 5. Ship the samples in a rigid container with sufficient packing material to prevent dislodging the collected fibers. Packing material that has a high electrostatic charge oh its surface (e.g.. expanded polystyrene) cannot be ued because such material can cause toss of fibers to the sides of the cassette. 8. Calibrate each personal sampling pump before and after use with a representative filler cassette installed between the pump . and the calibration devices. 7. Personal samples shall be taken in the "breathing 2one" of the employee (i.e.. attached to or near the collar or lapel neur the worker's face). B. Fiber counts shall be made by positive phase contrast using o microscope with an 8 to 10 X eyepiece and a 40 to 45 X objective, for a total magnification of approximately 400 X and a numerical aperture of 0.65 to 0,75. The microscope shall also be fitted with a green or blue filter. , 9. The microscope shall be fitted with a Walton-Beckelt -oyepiece;graticule calibrated for a field diameter of 100 micrometers (4 / - 2 micrometers). 10. The phase-shift detection limit of the microscope shall be about 3 degrees measured using the USE phase shift test slide as outlined below. a. Place the test slide on the microscope stage and center it under the phase objective. b. tiring the blocks of grooved lines into focus. Note.--The slide consists of seven sets of grooved lines (cu. 20 grooves to each block) in descending order of visibility from sets 1 to 7, seven being the least visible. The . requirements for asbestos, tremolite. Hothophyliire. and actinolite counting are that the microscope optics must resolve the groooved lines in set 3 completely, although they may appear somewhat faint, and that the grooved lines in sets 6 and 7 must be invisible. Sets 4 and 5 must be at least partially visible but may vary slightly in visibility between microscopes. A microscope that fails to meet these requirements ha9 either too low or too high a resolution to be. used for asbestos, tremolite, anthophyllite, and actinolite counting. c. If the image deteriorates, clean and adjust the microscope optics. If the problem persists, cosuit the microscope.manufacturer. 1.1. Each set of samples taken wilt include 10 percent blanks or a minimum of 2 blanks. The blank results shall be averaged and subtracted from the analytical results before reporting. Any samples represented by a blank having a fiber count in excess of 7 fibers/100 fields shall be rejected. 12. The samples shall be mounted by the acetone/triacetin method or a method with an equivalent index of refraction and similar clarity. 13? Observe the following counting rules, u. Count only fibers equal to or longer than 5 micrometers. Measure the length of curved fibers along the curve. b. Count all particles as asbestos, tremolite. anthophyllite, and actinolite that have a length-to-width ratio (aspect ratio) of 3:1 or greater. c. Fibers lying entirely within the boundary of the Walton-Beckett graticule field shall receive a count of 1. Fibers crossing the boundary once, having one end within the circle, shall receive the count of one half (*). Do not count any fiber that crosses the graticule boundary more than once. Reject and do not count any other fibers even though they may be visible outside the graticule area. d. Count bundles of fibers as one fiber unless individual fibers can be identified by . observing both ends of an individual fiber. e. Count enough graticule fields to yield 100 fibers. Count a minimum of 20 fields; stop counting at 100 fields regardless of fiber count. 14. Blind recounts shall be conducted at the . rate of 10 percent. Quality Control Procedures 1. Intralaboratory program. Each laboratory and/or each company with more than one microscopist counting slides shall establish a statistically designed quality assurance program involving blind recounts and H GLEASON-001010