10 CHAPTER 1 1965 Guide And Data Book Q. - 3.8380 (83.977 - 17.342) - 255.75 Btu W - 255.75 - 200 = 55.75 Btu (CP) - 200/55.75 = 3.5875 AW 55.75 - 50 - 5.75 Btu AS* - - 200/400 - - 0.5 Btu/R deg AS. - 255.75/500 - 0.51150 Btu/R deg AS^t - 0.51150 - 0.5 - 0.01150 Btu/R deg nAS.ni, = 500 X 0.01150 - 5.75 Btu (Bn). - 500 X 3.8380 (0.17078 - 0.03759) - 255.59 Btu (Ba). - 255.75 - 255.59 - 0.16 Btu (Ba4)t - 500 X 0.01119 - 5.59 Btu ZE,, - 5.59 -f 0.16 - 5.75 Btu fig. 15 .... Temperature-Entropy Diagram for DualCompression, Dual-Expansion Cyde of Example 9 fruits and vegetables) than Evaporator I (5 F, for frozen fish or poultry). Each evaporator could also carry a different load. Moving valve A to location B would improve the perform ance of the system, while the elimination of Compressor II and the installation of line C with back-pressure valve D would decrease the complexity, but would decrease the coefficient of performance. The possible practical combinations of refrigeration equip ment are numerous, and the reader may consult References 16 to 23 for detailed information on complex cycles.- In the next example, a Second-Law analysis shows how the introduction of a flash chamber and the duplexity of other equipment will improve the thermodynamic performance. Example 9: In this more complex cycle, the data are those of .Example 8. The equipment diagram is presented in Fig. 14,'which shows compound compression in a low-stage compressor (I) nrf a high-stage compressor (II), a flash intercooler, and two expan sion valves. All processes of the refrigerant are reversible, except ' those in the flash intercooler and expansion valves. When compared with the ideal basic vapor cycle of Example 8, the cycle in this example reduces the irreversibilities caused by the refrigerant, decreases the available portion of the heat re jected to the atmosphere, and effects a reduction in the net work mput to the cycle. The T-S diagram is given in Fig. 15. Inasmuch as the flow of refrigerant through each compressor is different, the liquid and vapor saturation lines are omitted. State 1 2 3 4 5 6 .7 8 State-Point Properties P psia 5.4090 16.0 16.0 51.940 51.940 16.0 16.0 6.4090 F -59.69 2.46 -17.99 56.23 40.31 -17.99 -17.99 -59.69 z h Btu/lb Btu^bR 1.0 70.727 78.178 1.0 75.329 83.977 0 17.342 17.342 0 4.664 4.664 0.17708 0.17708 0.17078 0.17078 0.08759 0.03950 0.01080 0.01192 Mi = 200/(70.727 - 4.664) - 3.0274 lb Afu = 3fi(h* - At)/(A, -A,) = 3.0274 (78.178 - 4.664)/(75J29 - 17.342) - 3.8380 lb Energy Qi 0. W (Ea), (Bah (bX (Bp). \BAA)r Btu 200 255.75 55.75 -50 250 0.16 255.59 5.59 Area d (a --* d) b + c+d b A summary of the important results of the Second-Law analyses presented in Examples 1 to 9 is given in Table 1. Second-Law analysis is an effective method for: (1) the es tablishment of the ideal refrigeration cycle and the work input therein, and (2) determination of the thermodynamic penalties which result from departures from the ideal cycle. PART III: ABSORPTION REFRIGERATION CyCLES Absorption refrigeration cycles are two-pressure, heatoperated cycles that make use of a vaporizable liquid as the refrigerant and a second liquid as the absorbent. The cycle can most easily be understood by comparing it to a con-* ventional compression refrigeration cycle. Fig. 16, consisting of three basic components: compressor, condenser, and evaporator. In the compression cycle, a angle fluid is used as the refrigerant; the liquid vaporises in the evaporator, takes in heat at low temperature, and is compressed, by applying work through a meehanieftl device, to a pressure such that it condenses at a higher temperature in the condenser. The compression cycle is a two-pressure cycle, the condenser operating at a higher pressure than the evaporator, and the two pressure domains are separated by the compressor and a refrigerant flow control (expansion valve). The absorption cycle. Fig. 17, consists of four basic com ponents .-absorber, generator, condenser, and evaporator (note that the condenser-evaporator portions of Figs. 16 and 17 are identical). The liquid refrigerant vaporizes in the evapo rator, taking in heat at low temperature, and is compressed by a heat-operated device to a pressure such that it condenses at a higher temperature in the condenser. The absorption cycle is also a- two-pressure cycle, and the two pressure domains are separated by the absorber-generator compression device and by a refrigerant flow control (expansion valve). Thus, the only fundamental difference between the absorp tion cycle and the compresion cycle is the substitution of the absorber-generator compressor operated by heat energy for the mechanical compressor operated by work energy. BASIC ABSORPTION REFRIGERATION CYCLE A more complete understanding of the bade absorption re-frigeration cycle, and, in particular, an understanding of the function of the absorber-generator system, can be attained by discussing the steps in the cycle as depicted in Fig. 17. Two working fluids are involved; the refrigerant circulates from Thermodynamics and Refrigeration Cydes 11 Table 1 .... Summary of Results from Examples I to 9 txanpl* . Crete In wsihOTte** W ASt# (ClJr 1 reversed Carnot none 50 0 0 2 reversed Carnot Atg. 3 modified reversed Carnot adiabatic compression friction 60 0.02 0 75 0.05 25 4 modified reversed Carnot friction (Qi) 75 0.05 25 5 modified reversed Carnot Atta, friction in all 4 processes 177.69 0.25538 100. 6 ideal basic vapor Afon exp. valve 62.07 0.02414 11.29 7 actual basic vapor Ala* Aig<, exp. valve, evaporator 71.98 0.04396 20.38 friction 8 actual basic vapor atom, Ata, exp. valve, friction in all 115.16 0.13032 47.17 4 processes 9 . vapor, 2 stage comp., flash Alg, exp. valves, intercooler intercooler 55.75 0.01150 5.59 If-idaig 0 10 0 0 27.69 0.78 1.60 17.99 0.16 AW, rASw* 2aa (CP| 04 10 3.33 25 2.67 25 2.67 127.69 1.1250- 12.07 3.2222 21.98 2.7785 65.16 1.7367 5.75 3.5875 * dig -- imveMflsfity due to beet truster through e Suite tempantan difference. Friction (Q -- Said friction daring proem of best Sow. tiie vnd(n<w- to the evaporator, to the absorber, to the gener ator, and back to the condenser, while the second fluid, the absorbent, circulates from the generator to the absorber and b^rk to the generator, etc. At the condenser, heat is removed from the refrigerant vapor coming from the generator, and the vapor - condenses. The liquid refrigerant then flows through an expansion valve, or its equivalent, into the evapo rator, where the pressure is maintained at a sufficiently low level so that the refrigerant will evaporate at the desired temperature, the heat of evaporation being taken from the material which is to be cooled. The refrigerant vapor-then flows through an unrestricted passage to the absorber. It is the function of the absorber to (1) maintain the de sired pressure in the k>w side, and (2)'dissolve the vapor in the absorbent so that the refrigerant can be returned to the high side without expending a large amount of mhan?wd work to compress the vapor. Both functions are accomplished because the absorbent has a high affinity for the refrigerant vapor, Le., the absorbent must have a strong tendency to absorb or dissolve the vapor. The pressure maintained will be that fixed by the nature of the absorbent, its concentra tion, and its temperature. These factors are selected by the designer in order to obtain the desired results. In the absorber, the absorbent and the refrigerant vapor are brought into inti mate contact to facilitate the dissolving of the'vapor. Hie absorption process is exothermic, and the heat released is known as the heat of absorption. This heat quantity is numerically equal to the sum of the heat of condensation of the vapor and the heat of dilution of the absorbent. Thus, in order for the absorber to continue its functions, the heat of - absorption must be continuously removed. Furthermore, this heat must be released at a temperature high enough so that the heat can flow to the available heat sink. Generally, the same heat sink will be available for both the condenser and the absorber. It is significant to note the degree of compression that is apparently brought about when the refrigerant vapor is dissolved in the absorbent. For example, if two pounds of a 10 percent aqueous-ammonia solution at 120 F (volume equals 0.034 cu ft) is allowed to absorb one pound of ammonia vapor saturated at 38 F (volume equals 4.13 cu ft), the resulting three pounds of 40 percent solution cooled to 120 F will have a volume of 0.057 cu ft. The increase of liquid volume is thus 0.023 cu ft, and the compression ratio is therefore 4T3/0.023 ~ 180. This very High compression ratio demonstrates the fig. 17 .... Basic Absorption Refrigeration Cyde