April 27,1992 Dow U.S.A. The Dow Chemical Company P 0 Bo* ' 50 Pladuemme Louisiana ZOTSS-CSO Daniel Cortez Eddie Guillory Petrin Petrin Building 4106 cc: Sam Boudreaux Caustic Building 2901 Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you. Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc DO A 11 4&:>2 OONFTDCNTTAI. ASBESTOS MONITORING DATA RESULTS: CAUSTIC 1092 **LOD ***LOQ EXPOSURE-GUIDELINES 8-HR. TWA LIMIT - 0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 of DATE SAMPLE# PERSONNEL DESCRIPTION DUR(MIN) 4/20/92 13523 *433-04-9195 Insulator: Cleaning up asbestos insulation that has contaminated a ditch. - WET METHOD USED 30 4/23/92 13525 *433-04-9195 Insulator: Regulated area; transferring Insulation from barrels to labeled bags. - WET METHOD USED 30 YQUL) 74 70 ** LOD FIB/CC <0.01 0.01 **`LOQ FIB/CC <0.52 <0.51 * The proper protective clothing was worn during the Job. North 7700 Ftesplrator with HEPA filters were worn during the Job. Note: The Limit of Quantitation has been defined as 100 Flbers/MM2 using the minimum fiber loarfing criteria specified. In the NIOSH analytical method 7400, the stated range of the method Is 100 to 1300 Flbers/MM2 filter area. Although samples below this range cm be analyzed, the method has not been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Flbers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this Information, we will establish 100 Flbers/MM2 filter area as our Limit of Quantitation and 7 Ffbers/MM2 fitter area as our Limit of Detection (which Is more representative of the actual fibers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. Du A 1 1 4of).s CONFIDENTIAL LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE N2 13523 PLANT/DEPT. ____ MONITORING FOR: /?<; h* ^ A- Ari DATE_ OTHER CHEMICALS PRESENT: SAMPLE COLLECTION MEDIA: 0 BADGE NO. TYPE TEMP/HUMIDITY: (REQUIRED FOR BADGES), 0 CHARCOAL TUBE SIZE_________________ 0"FILTER CASSETTE SIZE_ 0 SILICA TUBE SIZE _ O DRAGERTUBE TYPE. OTHER __________ SHIFT: HR. 0 12 HR. 0"PERSONNEL SAMPLE 0 AREA SAMPLE FULL SHIFT TWA STEL/TASK EMPLOYEE NAME. EMPLOYEE I D # JOB CLASSIFICATION. IH JOB CODE # CONTRACTOR COMPANY 5Astute butr RESPIRATOR USED? CTyES 0 NO yoo tv/L/tWC 7RESPIRATOR MODEL / CANISTER TYPE O MOUTH-BIT 0 DUST 0--HALF-FACE FULL-FACE 0 AIR-LINE 0 SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING jLoa --ty a rLkl. - W PUMP SERIAL NO... $1Q j. CALIBRATION DEVICE: STUBBLE METER 0 OTHER________ 0 ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: 1. 3J-W _ 3.__ BEGINNING FLOW RATE AVVGG. 3-V3ZI 1^''CC/MIN 0 L/MIN ENDING: 1. 2_3LS<3 3. ENDING FLOW RATE AVG. I CTCC/MIN 0 L/MIN SAMPLE AVERAGE FLOW RATE _____ TIME STARTED LQO I------------------ TIME STOPPED ___ ____ _-- TOT. RUNNING TIME(MIN) ft"*'- 3SAMPLE VOLUME (AVG FLOW X RUN TIME). ____________________________ ANALYTICAL REPORT REFERENCE # fcLprvCT- D 3.0- 5i\oO ANALYTICAL RESULTSi <^0 __________ _______<L Q< 1 VA>^V " * RESTRICTED FOR USE WITHIN DOW ONLY * VP-124 -4o. 5a FORM FILLED IN BY: f LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD sample 13525 PLANT/DEPT. I Q t<S /.'- MONITORING FOR: &K b^s. 4oS SAMPLE COLLECTION MEDIA: BADGE NO.____ TYPE. TEMP/HUMIDITY: (REQUIRED FOR BADGES). CHARCOAL TUBE SIZE--------------------------- ""FILTER CASSETTE SIZE M tn___ SILICA TUBE SIZE_________________ DRAGERTUBE TYPE_________________ OTHER ____________________ _ SHIFT: *"fTHR. 12 HR, O^ERSONNEL SAMPLE FULL SHIFT TWA STEL/TASK AREA SAMPLE EMPLOYEE NAME. IkeOff. EMPLOYEE I.D.#_ 7&51 JOB CLASSIFICATION. isySuhJcr IH JOB CODE#______ CONTRACTOR COMPANY 'P-Y-l, bA+'jtoJufdhCor/]- RESPIRATOR USED? 'YES NO UoyM^ l'} PC toUuaG RESPIRATOR MODEL / CANISTER TYPE MOUTH-BIT DUST 9----"UHAftLl FC-F[AACrcE ' FULL-FACE AIR-LINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING DATE H ?- f OTHER CHEMICALS PRESENT:. PUMP SERIAL NO. QlQk CALIBRATION DEVICE: 0'EfljBBLEMETER OTHER________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: 1. B-V'H ?. 3 ray 3 Qjrzu BEGINNING FLOW RATE AVG.4a ENDING: 1..___^ 2.. '0r^CC/MIN L/M1N ; 3JTV3 3. ENDING FLOW RATE AVG. SK^~ \ <f ' 'fcc/MlN L/MIN SAMPLE AVERAGE FLOW RATE TIME STARTED. L'usrlh- TIME STOPPED. TOT. RUNNING TIME(MIN). 3# SAMPLE VOLUME {AVG FLOW X RUN TIME). lie QrcQ.f S*rr-*jCj as -f-r^nyt tporrt/T. be h bo^S ANALYTICAL REPORT REFERENCE # - ANALYTICAL RESULTS: 43 0 _________ 4?^ RESTRICTED FOR USE WITHIN DOW ONLY * 35 W O Q< 4.0 VP-124 -jo^A IfTby^ fc$tP *Xc*d$Lp, FORM FILLED IN UO A 1 1 A c i [ j C OMT T DfTNTT A