GENERATOR'S WASTE MATERIAL PROFILE SHEET PLEASE PRINT IN INK OR TYPE (Bite, 12-pttcti). SUBMITTED TO WASTE TECH SERVICES DATE: June' 21 , 1989 WTS - 005.4 Waste Profits Shsst Cods A. GENERAL INFORMATION Generator Name: PPG lndustT1f[' Inc- 3. Facility AdOreas: P- ** 10u0 Lake Charles. LA (Columbia Southern Road) 6. Technical Contact: __ R-__L_C QJ1S 6 L 2. Generator USEPA ID: 4. Generator State ID: ^ame___________ _____________________________________5. Zip Code: ,T 7. Title: Assoc. Res. Chemig tphnna. ( 31$ 491T4Z5U B. MAIL WASTE TECH SERVICES INVOICES TO 1. SI Generating Facility (A, above), or 2 Company Name: 3, Phone: ( ) 4 Address: ________ _____________._________________________________________________________________ 5. Zip Code: C. i NAME OF WASTE <LnmP and Trench Cleanout from Derivatives____________________ 2. PROCESS GENERATING WASTE Chlorinated hydrocarbon production____________________ 3. Is this waste a Dioxin listed waste as defined in 40 CFR 261.31 (e.g.. F020. F021, F022. F023. F026. F027. or F028)? Yes E No If yes. DO NOT COMPLETE this form. 0. PHYSICAL CHARACTERISTICS OF WASTE ^ Color: 2. Does the waste have a 3. Physical State @ 70* F: strong incidental odor? Solid (3 Semi-Solid R1 arlf G No 0 Yes If known, G Liquid G Powder describe: Acrid Other 4. Layers: Multilayered H Bi-layered Single Phased 5. Specific Gravity: Range: ,,, 1.2 - 1.7 6. Free Liquids: 0 Yes No VOlU?5:-50 . 7 pH: G<2 > 2-4 4-7 0 7 7-10 10- <12.5 > 12.5 FI Range /, - fl NA 8. Liquid Flash Point: < 73F 73-99*F 3 100-139*F 140-199*F > 200*F None Closed Cup DOpenCup E. CHEMICAL COMPOSITION RANGE 1. Chinroflthone MIN. MAX. .01- .20 %, Ch1nronrhane 1r1-Dich1oroethene 1.1-Dichloroethane Trichloromethane 1.2-Dichloroethane Tetrachloromethane Trichloroethene 1.1.2-Trichloroethane 1.1.1,2-Tetrachloroethane 1.1.2.2,-Tetrachloroethane Tetrachloroethene ,5a 4.00,% .01- 0.10,% .01- 0.15,% ,2a 2.50,% . la 10 - 00,% 0.05- 0.15 ,% ------~-----7-----T.rG.0J0sJ2123.-rTTTTTT5T7777535UTTTTUTTT70,%%%%% Please note: The chemical composition total in the maximum' :>ee fcpiumn must be greater than or equal to 100%. TOTAi^ tac^e<( W Indicate if this waste contains any of the following: PCB's NONE or LESS THAN or ACTUAL d < 50 ppm ^ ^ ^ ppm Cyanides < 50 ppm ppm Phenolics D D < 50 ppm ppm Sulfides G D < 50 ppm ppm F. METALS Indicate if this waste contains any of the following: 1. DePTOX/TCLP or 2. GD Total METAL LESS THAN or ACTUAL. (Parts Per Mllll n> Arsenic < 5 < 500 l .u- / . Barium < 100 UNK Cadmium < 1 < 100 UNK Chromium < 5 Lead < 5 Mercury < 0.2 Selenium < 1 Silver < 5 Chromium-Hex < 5 Copper < 5 Nickel < 5 < 500 < 20 < 100 < 500 < 134 300-9C 60-80C UNK UNK UNK UNK 5-230C 800 -2 Thallium Zinc < 5 < 130 < 5 2.0-3. 60-70C n< n< .< S 021592 GENERATOR'S WASTE MATERIAL PROFILE SHEET (C ntinued) WTS-005.4 Waste Profits Shoot Cods G. OTHER HAZARDOUS CHARACTERISTICS 1. Is this waste a listed solvent waste as defined by 40 CFR 261.31 (F001. F0Q2. F003. FG04, or F005)? 2. Does this waste contain greater than 1000 ppm total halogenated organic compounds? 3. Indicate if this waste is any of the following: G RCRA Reactive G Radioactive Water Reactive G Etiological G Explosive G Shock Sensitive G Pesticide Manufacturing Waste Q Other Pyrophoric G3 None of the above G Yes 3 No @ Yes G No H. COMPLETE ONLY FOR WASTES INTENDED FOR FUELS or INCINERATION Beryllium Potassium Sodium Total Bromine Total Chlorine Total Fluorine Total Sulfur LESS THAN G3< 5000 ppm Q< 5000 ppm a< 5000 ppm G< 2% G< 35% a< 1 % or ACTUAL ppm ppm _ ppm % % % % I. OPTIONAL -- RECLAMATION. FUELS. OR INCINERATION PARAMETERS Provide if information is available. Range 1. Heat Value (BTU/lb): 100 . 1500 2. water: 30-55 % 3. Viscosity (cps): _1ULL_@Q_______BF G 100F G 150'F 4. Ash: 5-ftO ________ % s. Settleable solids: % 6. Vapor Pressure @ STP (mm/Hg): _________________________ 7. Is this waste a pumpabie liquid? G Yes G No Type of pump? __________________________________________ 8. Can this waste be heated to improve flow? G Yes Ijp No 9. Is this waste soluble in water? GYes G N 10. Particle size: Will the solid portion of this waste pass through a 1/8 inch screen? GYes G N J. TRANSPORTATION INFORMATION 1. Is this a DOT Hazardous Material? G Yes G No 2. Anticipated Annual Volume/Units: ______ L 3. Proper Shipping Name:Hazardous Waste. Liquid, n.o.s.. ORM-E, F024 RQ 4. Hazard Class: QRMz 5.1.D. #:NA9189 6. Additional Descnption: (___N_A 9189 ________________________ _ ) 7. Method of Shipment: Q Bulk Liquid Q Bulk Solid 3 Drum (Type/Size): DOT-2I7C 55 aa bther 8. CERCLA Reportable Quantity (RQ); _____________________________ 9. RQ Units (Ib/kg): lb . 10. USEPA Hazardous Waste? Yes Q No 11. USEPA Hazardous Waste Number(s): 'rOlU 12. State Hazardous Waste? 3 Yes ONo 13. State Hazardous Waste Number(s): ^0 24------------------------------------------- K. SPECIAL HANDLING INFORMATION G Additional Page(s) Attached L GENERATOR CERTIFICATION I hereby certify that all information submitted in this and all attached documents contains true and accurate descriptions of this waste material, and all relevant information regarding known or suspected hazards in the possession of the generator has been disclosed. 1. 61? 14Signature (J t W, H. COOPER Name (Type or Print) j ^PP ' 2 Associatp Research ' Title JUNE 21 , 1989 Date (HU- SL 021593 GENE. .TOR'S WASTE MATERIAL PROFL . SHEET PLEASE PRINT IN INK OR TYPE (Elite. 12-ottefl). SUBMITTED TO WASTE TECH SERVICES DATE: tlprpmber 10. 199Q-- WTS .QQ5,4_____________ Wist* Profile Sheet Code A. GENERAL INFORMATION , - Generator Name: ??G Industries, .ac. 2 Facility Address: . ?. 0. Box 1000 Lake Charles. LA (Columbia Southern Road) 5. Technical Contact: 7. Title: . 2. Generator USEPA ID: LAD_008086506_ . 4 Generator State ID: Same____________ ____5. Zip Cod : 70602 8. Phone: ( ) 8. MAIL WASTE TECH SERVICES 2 Company Name: ________________ i Address: ________________________ INVOICES TO 1. 0 Generating Facility (A, above), or -----------_______________________________ 3. Phone: ( 5. Zip Code: C. ` NAME OF WASTE Sump and Trench Cleanout from Derivatives________________________________ 2 PROCESS GENERATING WASTE Chlorinated Hydrocarbon Production___________________________ 3. is tms waste a Dioxin listed waste as defined in 40 CFR 261.31 (e.g., F020, F021, F022, F023. F026. F027. or F028)? Yes 0 No If yes. DO NOT COMPLETE this form. O. PHYSICAL CHARACTERISTICS OF WASTE !. Color: 2. Does the waste have a strong Incidental odor? Tan to Black 0 No D Yes If known, desenoe: 3. Physical State @ 70* F: D Solid S3 Semi-Solid G Liquid D Powder Othwr 4. Layers: G Multilayered !%] Bi-layered G Single Phased 5. Specific Gravity: Range: 1.2 * 1-7 6. Free Liquids: Q Yes G No Volume: 10-30 * 7 pH: C<2 Q > 2-4 4-7 0 7 7-10 10- <12.5 > 12.5 fyj Rang* 4 - 8 NA 3. Liquid Flash Point: < 73F 73-99F 100-139*F Gt 140-199*F 3 > 200F None Closed Cup QOpenCup E. CHEMICAL COMPOSITION 1 Solids (dirt, sand, catalyst, shell, etc.) Water Chlorinated hydrocarbons (mixture of Ci-Ca mixture) RANGE w- : W - 10 - !3U - 0.1 - 70 - - Please note: The cnemical composition total in the maximum imn must be greater than or equal to 100%. TOTAL: naicate if this waste contains any of the following: NONE or LESS THAN or ACTUAL PCB'S G [?3 < 50 ppm ppm Cvamoes Jt G < 50 opm Opm henoncs J < 50 oom ppm Sulfides J < 50 oom ppm F. METALS Indicate if this waste contains any of the following: % i. Eep^owtclp or 2. Total % METAL LESS THAN or ACTUAL % (Parts Per Million) % Arsenic m< 5 Q< 500 % Barium m< mo % Cadmium s< i G< ioo % Chromium 5 % Lead E< 5 Q< 500 O CM V dCM % Mercury E< % Selenium E< i Q< ioo % Silver E< 5 % Chromium-Hex < 5 Q< 500 Copper G< 5 0=51____ % Nickel n< 5 Q< 134 475 Thallium Zinc G< 5 < 130 < 5 link-____ n< < 021594 GENERATOR'S *ASTE MATERIAL PROFILE HEET (Continued) WTS-005.4 Waste Profile Sheet Coc G. OTHER HAZARDOUS CHARACTERISTICS * Is this waste a listed solvent waste as defined by 40 CFR 261.31 (F001. F002. F003, F004, or F00517 2. Does tnts waste contain greater than 1000 ppm total halogenated organic compounds? 3. Indicate if this waste is any of the following: _ RCRA Reactive G Water Reactive Q Radioactive G Etiological G Explosive G Shock Sensitive G Pesticide Manufacturing Waste Q Other Q Pyrophoric G None of the aoove G Yes 0 No 0 Yes G No H. COMPLETE ONLY FOR WASTES INTENDED FOR FUELS or INCINERATION Beryllium Potassium Sodium Total Bromine Total Chlorine Total Fluorine Total Sulfur LESS THAN 5000 ppm G< 5000 ppm 3< 5000 ppm G< 2% G< 35% 3< 1 % or ACTUAL Dpm ppm ppm % % % < OPTIONAL -- RECLAMATION. FUELS, OR INCINERATION PARAMETERS Provide it information is available. Range 1. Heat Value (BTU/lbi: _.1QQ_.- liOO___ 2. Water 10-30 3. Viscosity (cps):unk__ @Q________ F G 1Q0#F 150 4. Ash: 5-zSQ. % 5. Settleabte solids: 6. Vapor Pressure @ STP (mm/Hg): 7. is this waste a pumpaoie liquid? G Yes G No Type of pump? _______________ 8. Can this waste be heated to improve flow? 9. is this waste soluble in water? GYes GYes G No G No 10. Particle size: Will the solid portion of this wastepass through a 1/8 inch screen? GYes G N J. TRANSPORTATION INFORMATION 1. Is this a DOT Hazardous Material? G Yes G No 2. Anticipated Annual Volume/Units: ___________ 3. Proper Shipping Name: Ha7arrinns Waste. 11qn1rLn.ri.fi. .QRM-E.NA9189 RQ*-------------------------------- 4. Hazard Class:______ QEM=E------------------------------------------------- 5. I.D. #: NA SL189-------------------------------- 6. Additional Description: ( *FQ24.-.r)019 DQ22. DQ29-> DQ39. DQ40i PQ43)-------------------------------------- 7. Method of Shipment: G Bulk Liquid G Bulk Solid 0 Drum (Type/Size|:L Other 8. CERCLA Reportable Quantity (RQ): 1_____________________________ 9. RQ Units (Ib/kg): JJj---------------- 10. USEPA Hazardous Waste? 51 Yes G No n. USEPA Hazardous Waste Number(s): FQ-2A________ :2. State Hazardous Waste? G Yes G No 13. State Hazardous Waste Number(s): ___FQ34------------- K. SPECIAL HANDLING INFORMATION G Additional Page(s) Attache L. GENERATOR CERTIFICATION I hereby certify that all information submitted in this and all attached documents contains true an accurate descriptions of this waste material, and all relevant information regarding known or suspected hazards in the possession c the generator has been disclosed. o hjnJL&J Signature 3. r.Prald L. Perrv Name (Type or Print) C--^ 2 Env. Control Spec, ' Title 4, 1.14/11)90 ate SL 021595 31-70' WASTE ANALYSIS REPORT lVironmentai Laboratory PPG Industries, Inc., Lake Charles, La. jj^iple: Location of Sample: Composite of trenches and sumps at Pit. B. (WTS-005.4) All over Plant B. Sample Collector: W. Cooper - G. Prejean Sample Method/Device: Random grab - dipper Date/Time of Sampling 9-18-90 9:15 am Date All Analyses Completed: 10-22-90 Report Submitted By: Date: Gary Prejean 10-30-90 ANALYSIS RESULTS Test Parameters Isnitabilitv___( )___ N/A Corrosivity pH ........( N/A_______ 3.nch/vr Reactivity ( w< n/A As TCLP Ba Toxicity Cd < mg/L) Cr Pb N/A Ha Se As Standard 140 F 2-12.5 0.250 max ___________ Lab Log _Sample No 1402 5.0 max 100.0 max 1.0 max 5.0 max 5.0 max 0.2 max 1.0 max 5.0 max ND 0.50 ND ND ND _ ND____ ND ND Other Parameters (if needed) N/A ND/none detected CHLORINATED HYDROCARBONS 12LL Chloroethene (VC) ChlarOPthftng DiPhlorffipthanc 1, l-Dichloroethene 1, 1-Dichloroethane 1.2-Dichloroethene Trichloromethane 1_EL (MeClZ ) 1M1 i_D.CE). (cis/trans) (CHC13 ) 1.2-Dichloroethane (EDO 1.1.1-Trichloroethane U4C. Tetraghloromethane Trichloroethene 1.1.2-Trichloroethane Tetr^dhldrethane (CC14 (Trichlor) (TCE) (Perchlor) 1.1.1.2-Tetrachloroethane (unsvm) 1.1.2.2-Tetrachloroethane svm) Pentachloroethane Penta) para-Dichlorobenzene Hexachloroethane Hexachlorobutadiene (p-DCB (hexa) (HCBD) Unknown C1HC Total C1HC 1*1 Disposal Method WnQt Torh Profile No PGBs Heat Value Chlorine Water Density Ash Sodium PPm BTU/lb X vtX s/ml wt% wt% WTS-005.4 SL 021596 TEST PROCEDURE_______________________________________________________LAB LOG NO. 1 40'/'. PARAMETER METHOD USED Ignitabi1ity '/NVA Pensky-Martens Closed Cup Tester ASTM Standard D-93-79 Setaflash Closed Cup Tester ASTM Standard D-3278-78 1 j Other 1 i (Specify)j j Corrosivity ( pH ) -''N/A SW-846 Method 9040 pH measurement Other (Specify) Corrosivity (inch/yr) ^/A ____National Association of Corrosion Engineers Standard TM-01-69 Other (Sp cify) Reactivity Ss/a ! One af firmative answer will classify waste reactive) 1. Normally unstable without detonating? 2. Reacts violently with water? 3. Forms potentially explosive mixture with water? 4. Cyanide or sulfide bearing waste which can generate toxic gases, vapor or fumes under pH conditions between 2 and | 12.5? 5. Capable of detonation or explosive reaction if subjected to strong initiating source or if heated under confin ment? 6. Readily capable of detonation or explosive decomposition or reaction at standard temperature and pressure? 7. Forbidden Class A, or Class B explosive as defined in 49CFR 173.51, 173.53, and/or 173.88? SW 846 1 SW 846 SV1 846 Parameter Method Parametez' Method 1 'arameter Meithod TCLP* As 60.10 As 6010 PCB LD-2571 N/A Ba 6010 C1HC 5030 C1HC LD-2562A Cd 6010 Sodium 3050.6010 Heat Value LD-2562B Cr 6010 pH 9045 Chlorine LD-2562D Pb 6010 Water LD-2566 H* 7470 Ash LD-2561 Se 6010 Toxicity Char acteristic Leach. .ng Proc<sdure LABORATORY.IDENTIFICATION Laboratory:___ P Chrl$gTest Parameters Analyzed and Date Analyst! s )_: American Labs _ TCLP metals. volatiles, semi-volatiles __ Total metals ________10-22-90____________________ cc : SL 021597