Industrial Construction Co., Inc
P. O. BOX 5456
PHONES 439-3400 ' 436-9468
LAKE CHARLES, LOUISIANA 70606
February 6, 1986
REFINERIES GASOLINE PLANTS COMPRESSOR STATIONS
PIPELINES
Alternate #1 - Using Kynar pipe and fittings: Delivery time on Kynar is 14 days. Estimated number of calendar days to complete project after delivery of pipe and fittings is 21 days.
Total days to complete after notification of successful contractor is 35 days.
Alternate #2 - Using Conley Furan pipe and fittings: Delivery time on Furan is 28 days. Estimated number of calendar days to complete project after delivery of pipe and fittings is 21 days.
Total days to complete after notification of successful contractor is 49 days.
We hope this meets with your approval.
Yours very truly.
CB/bw
Charles Boudreaux
CUH 000000363
To: Visto Chemical Company
Attention:
Mr. Guy Bergeron P. 0. Box 727 Westlake, La. 70669
Dear Sir:
PROPOSAL
VISTA
February 6, 1986__________
Having carefully examined the Instructions to Bidders, all conditions of Contract form V3-9-S and the Basis of Bids for
Redirection of Laboratory Sink Drain to T-110
as well as the premises and the conditions affecting the work, the undersigned proposes to furnish ait necessary materials, labor, equipment, toots, transportation, services, etc., for completion of the work In accordance with above documents for the sum of:
------------- ----- --DOLLARS
rs See Below v
If notified of the acceptance of this proposal within thirty f 30
\ days 0f the time set for receiving the bids, the
undersigned agrees to execute a contract on the accompanying contract forma and the conditions thereof.
The estimated number of calendar days to complete this project Is
days. *See Attached Sheet
Is kibor man-hours up to and including the level of General Foreman or equivalent supervisor to eompletelhfs project
The undersigned Is registered as a federal and state employer, with employer's registration numbers as follows:
Federal
72-0387488_______________________
State
37262
State License
No. 6
Very truly yours,
MAILING ADDRESS:
P. 0. Box 5456 Lake Charles, La. 70606
Tula
Company
Estimator______________________ Industrial Constr... Co._ Inc.
ALTERNATES
Corporation_________________
(Designate as Corporation, Partnership or Individual)
Alternate I - Using Kynar Pipe and Fittings - Lump Sum Price of $38,200.00
AlternateII - Using Conley Furan Pipe and Fittings - Lump Sum Price of $30,650.00
Alternate III
CUH 000000364
*ff Ihis contract is to be consummated in the State of Louisiana, the state license number shall be inserted in the blank provided above and
shown on the bid envelope. The following certification must also be completed:
CSLclJL* Charles Boudr<^feiure)
.. . _ ,
.do hereby certify that
V
Industrial Constr. Co., Inc.
(Contractor)
is currently licensed under Louisiana Statutes Annotated-Revised Status Title 37, Chapter 24, as amended, as a Contractor in the State of
Lousiana.
V3.10S
CHEMICAL PLANTS RUBBER PLANTS POWER PLANTS CARBON BLACK PLANTS
Industrial Construction Co., Inc.
P. O. BOX 5456 PHONES 439-3400 ' 436-9468 LAKE CHARLES, LOUISIANA 70606
February 6, 1986
REFINERIES GASOLINE PLANTS COMPRESSOR STATIONS PIPELINES
Alternate #1 - Using Kynar pipe and fittings: Delivery time on Kynar is 14 days. Estimated number of calendar days to complete project after delivery of pipe and fittings is 21 days.
Total days to complete after notification of successful contractor is 35 days.
Alternate #2 - Using Conley Furan pipe and fittings: Delivery time on Furan is 28 days. Estimated number of calendar days to complete project after delivery of pipe and fittings is 21 days.
Total days to complete after notification of successful contractor is 49 days.
We hope this meets with your approval.
Yours very truly.
CB/bw
CUH 000000365
To: M. L. Ashby
Interoffice
Communication
Prom:
Da,e:
s# v# corkran October 31, 19 85
Subject: Laboratory Sink Drainage System Revision
FINAL ISSUE
The attached design specifies the redirection of the laboratory sink drainage flow into T-110. This stream currently flows into the sanitary sewer system. Because of the various chemicals in this stream, it is unsuitable for the sewer system. This project will involve the installation of a new line and a block valve to close off the existing line.
This project will be funded by miscellaneous under $15M funds. By copy of this to J. R. Holcomb, a definitive estimate is requested.
I can be reached at ext. 5026 for questions or comments
S. V. Corkran Process Engineer
br
cc: RAC-PEM-GEHfJRH^MLA-MCM-WPS-PE MGH (LCCP) O
CWH 000000366
Discussion
The laboratory sinks drain into an underground storage tank from which the water is currently pumped through a line leading into the sanitary sewer system. This sink drainage also includes disposed lab samples. Keeping organics from entering this sewer line is consistent with Vista's policy of eliminating potential sources of groundwater contamination. To prevent organics from entering this sanitary sewer line, the line carrying the water and chemicals from the storage tank will be rerouted into T-110. The line will be split at a point closest to T-110 and the existing line will be blocked with a block valve. A new 3" Kynar line will run from this point directly into T-110. This water will flow from T-110 into the steam stripper and wastewater treatment and will bypass the sewer system completely, thus eliminating any potential for groundwater contamination.
CWH 000000367
Work List 1) Install a 3" tee on the existing line at the
northeast corner of the main control room. 2) Install a 3"-150# diaphragm block valve
immediately downstream of the tee in Item 1 in the existing line. 3) Run a 3" Kynar line from the tee in Item 1 through the piperack to the block valve on the existing nozzle on the south side of T-110. Include a 3/4" bleed valve downstream of the tee in Item 1/ and a 3/4" bleed valve and a 3"-150# check valve upstream of the block valve on T-110.
CWH 000000368
xwro
4
PIPERACK
N*
UNDERGROUND
COLLECTION
TANK.
i
PRO l-A
PROl-S
LEGEND -- E-ViSTiwG
NEW ------UNDEA.GROUNO
X BLOCK V/U.VE
<> v/Oft-VL LIST TTEM h^j check valve * -f*3 LEED VAlVE
^ VALVE*4,
4t Set <iHcuJlc<C inform
CUN 00000036?
FIGURE.
LtlorSfary Sint Dro*naj&
System Revision
j Drown Bj ' S. Y- Corjtnxn | Dochs ; 1 o-M- VS