Document Z45dEeVao3MYwqxYyVndQEe4Y
Visto Chemical Company
15990 N. Barker's Landing Rd. Post Office Box 19029
Houston.Texas 77224 Phone (713) 531-3200
October 14, 1985
Mr. Scott Corson Vacu-Maid Inc. P.0. Box 1708 Ponca City, OK 74601
VIST/
Dear Scott:
Enclosed, please find a current Material Safety Data Sheet for Vista Dry Blend. I understand an 0SHA inspector told you that you must have MSDS's for all materials in your plant based on soon to be effective 0SHA standards.
I believe he was probably referring to the 0SHA Hazard Communication Standard. This standard requires that an MSDS be obtained for; all hazardous materials, as defined by 0SHA. Vista PVC Dry Blend is not an OSHA hazardous material. The small amounts of additives and VCM residual do not create a significant exposure potential. Dust from handling PVC Dry Blend is classed as a nuisance dust only.
Please give me a call if you have further questions on the safety and health aspects of Vista PVC.
Sincerely,
Thomas G. Grumbles, CIH Environmental Quality Manager
ajo/8
Enclosure
cc Rod Crain
VVV 000023291
TO: John Friend
TSG:
XF: /Ab^iCW
Interoffice Communication
FROM: DATE:
SUBJ:
Tom Grumbles October 8, 1985
ABERDEEN PLANT INDUSTRIAL HYGIENE PROGRAM ASSESSMENT
VIST/
The program assessment was conducted on September 24 - 25. The team consisted of myself, Keith Fogg, Safety Director LAB plant. Dr. Drumwright; Medical Manager, and Michele Goodreau, Environmental and Health Specialist. Action taken on the recommendations from the 1983 audit report were reviewed and discussed. Interviews were held with personnel in the safety department, various hourly operations and laboratory employees, and operations and mechanical supervision.
i.ncervicws wxt.i
xncrcated a good awareness o. and comnj.cnenz
to the industrial hygiene program. In particular, the supervisory
follow-up on measured overexposures to find exposure sources is
good. Employee interviews did not reveal any overt health or safety
concerns. The mechanical department does safety audits on a random
basis and uses a form to assure consistency in this effort. This
type of "self-auditing" is a very positive idea and certainly
> encouraged.
Below are the assessment team's recommendations. Items noted on the walk-through inspection and discussed with you are not included below.
1. A large amount of time was spent reviewing and discussing the respiratory protection program. Specific recommendations are below.
a. The respiratory protection program should contain specific selection criteria for respirator use. The program lacks specificity as to the selection criteria for specific jobs, or classes of jobs with known exposure potential. There appears to be some confusion as to what equipment should be considered in VCM service and subsequently what respiratory equipment is needed for jobs on that equipment.
b. Reference was made in conversations to various letters that had been issued addressing specific uses of respirators. These "guidance" letters should be consolidated into the program.
c. The manufacturer instructions included in the program as appendices should be reviewed and consideration given to removing them from the policy. They are redundant in many
t cases and of little practical use as written.
d. Based on action taken in (a) and (b) above. Section II, Selection and Approval of the program should be revised to reflect actual plant practices.
VVV 000023292
John Friend Page 2 October 8, 1985
2. In Blending and Compounding several recommendations regarding lead exposures are made below.
a. Maintenance personnel work in the lead areas and are included in the blood lead program. Consideration should be given to monitoring maintenance jobs in this area to determine airborne lead exposures. This could be area monitoring if done carefully.
b. A review of personnel clean-up procedures at the end of shift should be done to assure proper disposal of contaminated work clothing, and that personal hygiene guidelines are followed.
c. To obtain a total dust measurement approximately one-third of the lead air samples are handled at the plant before shipment to the analytical laboratory. This practice should be stopped as there is potential to disturb the integrity of the lead analysis. Total dust numbers could be obtained by the laboratory being used for lead analysis.
3. To determine the effectiveness of exhaust ventilation systems and quantify exposures, air sampling of welding operations in the maintenance shop should be considered.
4. Further sampling of short-term exposures should be done to determine respiratory protection needs and workplace procedures.
For recognized high potential exposure jobs where air-supplied equipment is used, a review of "job-site" preparation should be done to preclude casual exposures to those not directly involved in the job.
5. There was some concern expressed during interviews regarding the validity of the VCM monitoring. Several instances of measured overexposures on personnel who never entered the vinyl area on the day of sampling were mentioned.
The quality control program that I was to assist the plant in developing has not been developed. I still plan on proposing a mechanism to independently verify the sampling and analytical methods the plant is using.
Please let me know if you wish to discuss any of the above. We are available to assist in accomplishing the above recommendations. I want to thank-you and your staff for their time and cooperation during the plant visit.
------------
as G. Grumbles
ajo/7 cc RDG-, JRD, KLF, ALS
VVV 000023293