Document Z45NLbxgMXxG77BqgJQa50EKL
Heaters, Hot Water
Bell and Gossett Company
3000 Wallace Street
Chicago, 111.
HOT WATER SYSTEMS AND SPECIALTIES
B & G INDIRECT WATER HEATERS -FOR STEAM AND VAPOR SYSTEMS
Ratings below are based on 100 degree rise in three hours with boiler water temperature of 180 degrees or more
' Description
SINGLE COIL For residences of all sizes. Duplex apartments and small buildings.
DOUBLE COIL For larger apartments, garages. medium sized factories'and office buildings.
TRIPLE COIL t*or heavier requirements.
DOUBLE TRIPLE COILS
No.
Capacity Gallons
- Max.
Length Inches
Max. Shell Coil- Shipping Width Openings Openings Weights Inches Inches Inches Pounds
I I30
30' n%
554
40 40
554
52 52
66 66
82 82
100 120
100 120
22^4
144 144 25'/. 7%
12 13 - 15 29
39 40
42 46
160 160 12
2
192 192 14V, \\<A 2
300 300 1954 11% 2
400 400 23% 11% 2
i% 53 i% 59 i% 78 i% 86
600 800 1000
1200 1600 2000
600 800 1000
1200 1600 2000
21% 25% 29%
23%
SB
15% t vA
15%
29 29 29
3 3 3
4 4 '4
% 230 250 2% 290
568
i 642 716
B & G TANKLESS HEATER
This B & G Tankless Type Heater has been designed to fulfill a need for a heater of unusual capacity that could be installed in boiler rooms lacking space for storage tanks.
Size No.
12 20 30
For all Steam, Vapor and Hot Water Heating Boilers
Heating Surface in Square Feet
Capacities in Gallons in 1 Hour Heated from 50 F to 130 F
Boiler Water at 212 F
Boiler Water at 200 F
Boiler Water at 180 F
12 207 168 100
20 345 288 168 30 516 430 250
B & G THERMOCHEK
Controls automatically the temperature of hot water storage tanks heated by indirect heaters. A simple, completely automatic device that eliminates lime and sediment formation in the heater coils. Sizes 1-J4 in. and 2 in.
B & G MONOFLO FITTING
This fitting is used on mechanically - circulated one-pipe hot water sys tems. When installed in the main at each tadiator connection, it assures a balanced system with short cir cuits eliminated and all radiators receiving their full quota of hot water.
No.
V/4.... .........................
|l/2......................................................... 2 ........................................................
Size. Inches i/t
B&G ORIFLO FITTING
The Oriflo fit ting is for use on hot water radi ators. New or old gravity or forced circula tion jobs can use this device for accurately regulating the temperature drop through the radiators, thereby balancing the heating system quickly with minimum expense and with out shutting down the heating plant.
924
Bell and Gossett Company
Healers, Hot Water
B & G TRIPLE DUTY SYSTEMS FOR HOT WATER SYSTEMS
Size No.
Recommended Capacities "Capacities Shipping
Tank
Cals,
Sq.Ft. Weight
Sizes
per Hour EJD.R. Pounds
15 30 gals. 16 45 gals.
17 66 gals. 18 88 gals. 19 30 gab. 20 42-66 gals. 21 66-88 gals.
30
1.500
152
35
1,500
153
40
1,500
155
50
1,500
159
30
3,000
158
40
3,000
161
50
3,000
165
22 66-120 gals.
70
3,000
183
23 120-180 gals.
100
3,000
198
24 180-300 gals.
140
3,000
213
25 300 to 400 gals. 26 WU to M)U gals. 27 5UU to bUO gals.
200 266 333
6,000 6,000
6,000
445 465
fe 505
"Capacities in square foot of direct radiation are based on 200 Btu radiator emission with a 20 F. drop.
B&G BOOSTER
Size' No.
Face to Face
Dimensions
Flange Size
Motor 110 Volt 60 Cycle
Normal Delivery Gallons per
Minute
Shipping Weight
r
i%' V y
7W 8%' 8%'
\2T
1 w Screwed
\W Flanged 2 " Flanged 3 " Flanged
1/8 hp. 1/8 hp. 1/6 hp.
1/3 hp.
! 5 at 2 ft. head 30 at 2 ft. head 60 at 4/ ft. head 100 at 5% It. head
70 lbs. 80 lbs. 83 lbs. 135 lbs.
B&G MOTORIZED VALVES
These valves are guaranteed to stop the flow of water in the heating mains of hot water sys tems. They are used for zone control and in year around, in directly heated domestic hot water systems. Operation is by a 60 cycle, A.C. 25-volt induc tion type motor.
Series No.
i% i% 2 2% 3 4 5 6
D & T SELF-FILLING, AIR-CUSHIONED TANK EQUIPMENT
Self-Filling Air-Cushioned Tank Equipment consists of a D & T Air Tank and a D & T No. 500 "All In One Unit" which is a combination relief and pressure reducing valve, performing the double duty of relieving excess pressure and keeping the system filled with water.
System No.
518 524 530 535
Capacity Sq Ft Radiation
Up to 500 ft 500 to 800 ft 800 to 1200 ft 1200 to 1600 ft
System No.
540 ` 560
580 600
Capacity Sq Ft Radiation
1600 to 2000 ft 2000 to 3000 ft 3000 to 4000 ft 4000 to 5000 ft
Description
Single 1V* in. Main Single V/i in. Main Single L tn. Main Single 2Vz in. Main Single 3 in. Main Single 4 in. Main Single 5 in. Main Single 6 in. Mam
D & T SIMPLEX TANK-IN-BASEMENT SYSTEM This system consists of an air-tight Compression Tank, Relief Valve (illustrated), Thermometer, Gage and Vacuum Breaking Valve. Made in 14 different sizes with capacities up to 5000 sq ft of radiation.
925
Shipping Weight Pounds
19 20 23 35 40 78 140 190