Document Z45NLbxgMXxG77BqgJQa50EKL

Heaters, Hot Water Bell and Gossett Company 3000 Wallace Street Chicago, 111. HOT WATER SYSTEMS AND SPECIALTIES B & G INDIRECT WATER HEATERS -FOR STEAM AND VAPOR SYSTEMS Ratings below are based on 100 degree rise in three hours with boiler water temperature of 180 degrees or more ' Description SINGLE COIL For residences of all sizes. Duplex apartments and small buildings. DOUBLE COIL For larger apartments, garages. medium sized factories'and office buildings. TRIPLE COIL t*or heavier requirements. DOUBLE TRIPLE COILS No. Capacity Gallons - Max. Length Inches Max. Shell Coil- Shipping Width Openings Openings Weights Inches Inches Inches Pounds I I30 30' n% 554 40 40 554 52 52 66 66 82 82 100 120 100 120 22^4 144 144 25'/. 7% 12 13 - 15 29 39 40 42 46 160 160 12 2 192 192 14V, \\<A 2 300 300 1954 11% 2 400 400 23% 11% 2 i% 53 i% 59 i% 78 i% 86 600 800 1000 1200 1600 2000 600 800 1000 1200 1600 2000 21% 25% 29% 23% SB 15% t vA 15% 29 29 29 3 3 3 4 4 '4 % 230 250 2% 290 568 i 642 716 B & G TANKLESS HEATER This B & G Tankless Type Heater has been designed to fulfill a need for a heater of unusual capacity that could be installed in boiler rooms lacking space for storage tanks. Size No. 12 20 30 For all Steam, Vapor and Hot Water Heating Boilers Heating Surface in Square Feet Capacities in Gallons in 1 Hour Heated from 50 F to 130 F Boiler Water at 212 F Boiler Water at 200 F Boiler Water at 180 F 12 207 168 100 20 345 288 168 30 516 430 250 B & G THERMOCHEK Controls automatically the temperature of hot water storage tanks heated by indirect heaters. A simple, completely automatic device that eliminates lime and sediment formation in the heater coils. Sizes 1-J4 in. and 2 in. B & G MONOFLO FITTING This fitting is used on mechanically - circulated one-pipe hot water sys tems. When installed in the main at each tadiator connection, it assures a balanced system with short cir cuits eliminated and all radiators receiving their full quota of hot water. No. V/4.... ......................... |l/2......................................................... 2 ........................................................ Size. Inches i/t B&G ORIFLO FITTING The Oriflo fit ting is for use on hot water radi ators. New or old gravity or forced circula tion jobs can use this device for accurately regulating the temperature drop through the radiators, thereby balancing the heating system quickly with minimum expense and with out shutting down the heating plant. 924 Bell and Gossett Company Healers, Hot Water B & G TRIPLE DUTY SYSTEMS FOR HOT WATER SYSTEMS Size No. Recommended Capacities "Capacities Shipping Tank Cals, Sq.Ft. Weight Sizes per Hour EJD.R. Pounds 15 30 gals. 16 45 gals. 17 66 gals. 18 88 gals. 19 30 gab. 20 42-66 gals. 21 66-88 gals. 30 1.500 152 35 1,500 153 40 1,500 155 50 1,500 159 30 3,000 158 40 3,000 161 50 3,000 165 22 66-120 gals. 70 3,000 183 23 120-180 gals. 100 3,000 198 24 180-300 gals. 140 3,000 213 25 300 to 400 gals. 26 WU to M)U gals. 27 5UU to bUO gals. 200 266 333 6,000 6,000 6,000 445 465 fe 505 "Capacities in square foot of direct radiation are based on 200 Btu radiator emission with a 20 F. drop. B&G BOOSTER Size' No. Face to Face Dimensions Flange Size Motor 110 Volt 60 Cycle Normal Delivery Gallons per Minute Shipping Weight r i%' V y 7W 8%' 8%' \2T 1 w Screwed \W Flanged 2 " Flanged 3 " Flanged 1/8 hp. 1/8 hp. 1/6 hp. 1/3 hp. ! 5 at 2 ft. head 30 at 2 ft. head 60 at 4/ ft. head 100 at 5% It. head 70 lbs. 80 lbs. 83 lbs. 135 lbs. B&G MOTORIZED VALVES These valves are guaranteed to stop the flow of water in the heating mains of hot water sys tems. They are used for zone control and in year around, in directly heated domestic hot water systems. Operation is by a 60 cycle, A.C. 25-volt induc tion type motor. Series No. i% i% 2 2% 3 4 5 6 D & T SELF-FILLING, AIR-CUSHIONED TANK EQUIPMENT Self-Filling Air-Cushioned Tank Equipment consists of a D & T Air Tank and a D & T No. 500 "All In One Unit" which is a combination relief and pressure reducing valve, performing the double duty of relieving excess pressure and keeping the system filled with water. System No. 518 524 530 535 Capacity Sq Ft Radiation Up to 500 ft 500 to 800 ft 800 to 1200 ft 1200 to 1600 ft System No. 540 ` 560 580 600 Capacity Sq Ft Radiation 1600 to 2000 ft 2000 to 3000 ft 3000 to 4000 ft 4000 to 5000 ft Description Single 1V* in. Main Single V/i in. Main Single L tn. Main Single 2Vz in. Main Single 3 in. Main Single 4 in. Main Single 5 in. Main Single 6 in. Mam D & T SIMPLEX TANK-IN-BASEMENT SYSTEM This system consists of an air-tight Compression Tank, Relief Valve (illustrated), Thermometer, Gage and Vacuum Breaking Valve. Made in 14 different sizes with capacities up to 5000 sq ft of radiation. 925 Shipping Weight Pounds 19 20 23 35 40 78 140 190